Packaging Industry Specialized Instruments
Filter
Showing 1111–1140 of 1185 results
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | ProTear |
| Measurement Principle | Elmendorf Pendulum Tear Method |
| Compliance Standards | ASTM D1922, D1424, D295, D751 |
| Display | 4-line × 16-character LCD, multi-angle viewing |
| Accuracy | ±0.2% of pendulum capacity |
| Sample ID Input | 13-character alphanumeric |
| Data Storage | Up to 99 test results |
| Statistical Functions | Mean, Std. Deviation, Min/Max, Variance |
| Units | gf, lbf, mN, % of pendulum capacity |
| Fixture | Pneumatically actuated clamping |
| Pendulum Release | Pneumatic |
| Power Supply | 220–230 V ±10%, 50 Hz |
| Power Consumption | ≤10 W |
| Dimensions (L×W×D) | 578 × 483 × 398 mm |
| Operating Temp. | 10–50 °C |
| Storage Temp. | −25–70 °C |
| Sample Compatibility | Paper, board, film, foil, nonwovens, coated fabrics, packaging laminates |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-10 |
| Sealing Temperature Range | 20–400 °C (±0.15 °C accuracy) |
| Temperature Resolution | ±0.1 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 100 ms–99 s |
| Time Resolution | 10 ms |
| Time Accuracy | ±1 ms |
| Time Repeatability | ±2 ms |
| Dual Load Cells (Left/Right) | 362 kg (1000 lbf) total capacity, ±0.09 kg (±0.2 lbf) accuracy & repeatability |
| Peel Load Cell | 11.34 kg (25 lbf), 0.1% FS accuracy, ASTM E-4 calibrated |
| Seal Jaw Length Options | 50.8 mm (2 in) for hot tack or 127 mm (5 in) with auto-feed turntable |
| Jaw Width Range | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Configurations | Flat, Grooved, Custom, or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended 90 psi), integrated pressure switch |
| Dimensions (W×D×H) | 584.2 × 508 × 794.2 mm |
| Weight | 79.3 kg |
| Brand | Thwing-Albert |
|---|---|
| Origin | USA |
| Model | SL-2 |
| Sealing Temperature Range | Ambient to 400 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Control Stability | ±0.2 °C |
| Sealing Pressure Range | 5–700 psi (34.5–4830 kPa) |
| Pressure Resolution | 1 psi (7 kPa) |
| Sealing Time Range | 200 ms–99 s (with 10 ms resolution at low load |
| Time Accuracy | ±25 ms |
| Time Repeatability | ±50 ms |
| Jaw Length | Up to 304.8 mm (12 in) |
| Jaw Width | 6.35–25.4 mm (0.25–1.00 in) |
| Jaw Surface Options | Flat, Grooved, Custom or Standard Geometric Profiles |
| Power Supply | 230 V / 50 Hz |
| Compressed Air Requirement | 80–120 psi (recommended: 90 psi) |
| Dimensions (W×D×H) | 584.2 × 400 × 620 mm |
| Weight | 72.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thwing-Albert Vantage |
| Price Range | USD 14,000 – 70,000 |
| Load Capacity | 1 kN (225 lbf) |
| Peel Angle | Fixed 90° |
| Standard Compliance | ASTM D6862, ASTM D6252, PSTC-1A |
| Fixture Part No. | 1750–3005 |
| Sample Type | Flexible Adhered Substrates (e.g., pressure-sensitive tapes, laminates, labels, medical adhesives) |
| Test Mode | Tensile Peel |
| Grip Configuration | Upper Movable Jaw + Lower Motorized Crosshead with Angularly Constrained Specimen Stage |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Model | TY-CHY |
| Measurement Range | 0–5 mm (customizable fixtures available) |
| Measuring Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper) |
| Accuracy | ±0.5 µm |
| Resolution | 0.1 µm |
| Class of Accuracy | Grade 0.5 |
| Contact Area | 50 mm² (film mode), 200 mm² (paper mode |
| Traverse Speed | 10 mm/min (adjustable) |
| Dimensions | 450 × 340 × 390 mm |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 6672-2001, GB/T 451.3-2002, GB/T 6547-1998, ISO 4593:1993, ISO 534:2011, ISO 3034:2011, ASTM D374-1999, ASTM D1777-1996 (2007), JIS K6250-1997, JIS K6783-1994, JIS Z1702-1994, BS 3983-1989, BS 4817, TAPPI T411 |
| Interface | RS232 serial port |
| Optional Accessories | Auto-sampler unit, PC-based analysis software, calibration weights, communication cable |
| Brand | TM Electronics |
|---|---|
| Origin | USA |
| Model | BT-1000 |
| Dimensions | 13" W × 15" D × 6.5" H |
| Power | 115 V, 50/60 Hz, 150 W |
| Pressure Range | 0.2–50 psig and 1–100 psi (oil-free, dry air) |
| Time Range | 0.1–1000 s |
| Resolution | 0.5 in H₂O |
| Test Modes | Burst, Creep, Creep-to-Failure, Leak Detection, and combined dual-mode tests (e.g., Creep/Leak, Leak/Burst) |
| Display | 20×16-character LCD with graphical capability |
| Data Storage | 1000 test results |
| Program Memory | 40 user-defined test protocols |
| Statistical Output | X̄-R control charts, histograms, mean, standard deviation, min/max, range, count |
| Interface | DB25 female (print & PLC auxiliary), DB25 male (RS-232 ASCII serial, PC/WINDOWS compatible) |
| Compliance | ISO 11607, ASTM F1140, ASTM F2054 |
| Calibration | NIST-traceable |
| Brand | TME |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solution |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Detection Principle | Differential Pressure Decay & Mass Flow Measurement |
| Channels | 1–4 Simultaneous or Sequential |
| Pressure Range | –13.5 to 300 psig (customizable) |
| Vacuum Range | –13.5 to 0.5 psig |
| Flow Range | 10–10,000 ccm (customizable) |
| Resolution | 0.0001 psig |
| Data Storage | 100 test configurations + 5,000 result records |
| Interface | RS-232 |
| Calibration | NIST-traceable |
| Compliance | Designed for ISO 9001, ASTM F2096, ASTM D3078, USP <1207>, and GMP-aligned validation protocols |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 32-07 |
| Speed Range | 5–43 cm/min |
| Travel Distance | 2.5–30.5 cm |
| Display | 5.7-inch color LCD |
| Weight | 25 kg |
| Dimensions | 515 × 495 × 508 mm |
| Compliance | ASTM D1894, TAPPI T816 & T549 |
| Data Storage | 100 readings with statistical analysis (mean, SD, min/max) |
| Interface | RS232 |
| Optional Heating Chamber | Ambient to 177 °C |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 32-07 |
| Adjustable Speed Range | 5–43 cm/min |
| Adjustable Travel Distance | 2.5–30.5 cm |
| Weight | 25 kg |
| Dimensions | 515 × 495 × 508 mm |
| Compliance | ASTM D1894, TAPPI T816 & T549 |
| Display | 5.7-inch color LCD |
| Data Storage | 100 readings with statistical analysis (mean, SD, min/max) |
| Interface | RS232 |
| Optional Heating Chamber | Ambient to 177 °C |
| Brand | TMI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 43-76 Pendulum Impact Tester |
| Pricing | Available Upon Request |
| Unit Options | J/m, ft·lb/in, kg·cm/cm, ft·lb/in², kg·cm/cm², kJ/m² |
| Output Interfaces | USB, RS232 |
| Net Weight | 25 kg (55 lb) |
| Dimensions (W×H×D) | 914 mm × 508 mm × 965 mm (36 in × 20 in × 38 in) |
| Pneumatic Supply | 100 PSI (min. 60 PSI) |
| Power Input | 120/240 VAC, 50/60 Hz |
| Safety Enclosure | Polycarbonate barrier |
| Control Interface | 7-inch digital touchscreen |
| Pendulum Release | Pneumatically actuated |
| Brake System | Automatic electromagnetic braking |
| Specimen Classification | Full break, partial break, hinge, non-break |
| Calibration | Fully automated self-calibration routine |
| Clamping | Precision pneumatic clamping system |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 79-11-00 |
| Measurement Range | 0–399 gf |
| Display | 3-digit LCD |
| Creasing Angle | 90° |
| Stiffness Bend Angle | 15° |
| Readout Time | 15 s |
| Resolution & Accuracy | ±1.0 gf |
| Power Supply | 240 V, 50 Hz |
| Fuse | 500 mA |
| Dimensions (Instrument) | 235 mm (H) × 180 mm (L) × 320 mm (W) |
| Dimensions (Packed) | 670 mm (H) × 550 mm (L) × 520 mm (W) |
| Weight (Instrument) | 11 kg |
| Weight (Packed) | 14 kg |
| Includes | Precision cutting knife and calibration weights |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 83-20 |
| Measurement Principle | Pendulum-type Elmendorf method |
| Max Range | 64,000 mN |
| Range Steps | 4,000 / 8,000 / 16,000 / 32,000 / 64,000 mN |
| Accuracy | ±1% of reading or ±0.25% of selected range |
| Sample Cut | Automatic pre-notch |
| Clamping | Pneumatic-mechanical dual-action clamp |
| Display | Digital force readout |
| Data Interface | RS-232 serial output |
| Safety | Interlocked transparent guard |
| Reset Mechanism | Motorized pendulum repositioning |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 83-76 |
| Power Supply | 120/240 VAC, 50/60 Hz |
| Pneumatic Pressure Requirement | 600 kPa |
| Dimensions (W×D×H) | 305 × 305 × 508 mm |
| Weight | 10.4 kg |
| Display | 7-inch full-color touchscreen |
| Data Storage Capacity | up to 200 test records |
| Tear Force Units | gf, mN, lbf, % full scale |
| Clamping Pressure | adjustable in psi |
| Optional Pendulums | 200 g, 400 g, 800 g, 1600 g (83-11-08), 3200 g (83-11-06), 6400 g (83-11-07) |
| Interface Options | USB flash drive, USB ESC/POS printer, RS232, GraphMaster™ software port |
| Compliance | ASTM D1922, ASTM D1424, ISO 1974, TAPPI T414, GB/T 455 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMI 58-05-00-0002 |
| Measurement Range | 0–12,000 s |
| Dimensions | 80 cm × 56 cm × 61 cm |
| Power Supply | 220 V / 50 Hz / Single-phase / 2 A |
| Weight | 51 kg |
| Compliance | ISO 5627, GB/T 456–1989, TAPPI T 479 om-17 |
| Brand | TMI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 75-50 |
| Price | Upon Request |
| Heat Seal Temperature Range | Ambient to 350°C (662°F) |
| Temperature Resolution | ±0.1°C (0.18°F) |
| Temperature Accuracy | ±0.70°C (1.26°F) |
| Hot Tack Load Cell Capacity | 111.2 N (11.3 kgf) |
| Load Accuracy | 0.1% Full Scale |
| Peel Speed Range | 1–200 mm/sec (0.04–7.87 in/sec) |
| Seal Load Cell Capacity | 4448.2 N (453.6 kgf) |
| Load Accuracy | ±0.89 N (±0.09 kgf) |
| Seal Pressure Range | 137.9–2758 kPa (20–400 psi) |
| Pressure Resolution | 0.68 kPa (0.1 psi) |
| Seal Delay Time Range | 0.20–99.99 s |
| Time Resolution | 10 ms |
| Control Timing Accuracy | ±0.025 ms |
| Seal Jaw Length | Up to 203.2 mm (8.0 in) |
| Jaw Width | 12.7–25.4 mm (0.5–1.0 in) |
| Jaw Surface Configurations | Flat, Vertical, Horizontal, Custom, or Standard Geometries |
| Compliance | ASTM F1921, ASTM F2029, ASTM F88, ISO 11607-2, USP <1207> |
| Calibration Standard | ASTM E4 |
| Brand | TMI |
|---|---|
| Origin | USA |
| Model | 79-11-00 |
| Force Range | 0–399 gf |
| Display | 3-digit LCD |
| Crease Angle | 90° |
| Bend Angle (Stiffness) | 15° |
| Readout Time | 15 s |
| Resolution & Accuracy | ±1.0 gf |
| Power Supply | 240 V, 50 Hz |
| Fuse | 500 mA |
| Dimensions (Instrument) | 235 mm (H) × 180 mm (L) × 320 mm (W) |
| Dimensions (Packed) | 670 mm (H) × 550 mm (L) × 520 mm (W) |
| Weight (Instrument) | 11 kg |
| Weight (Packed) | 14 kg |
| Includes | Precision cutting blade and certified calibration weights |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | AB6000 / AB6010 |
| Speed Range | 1–60 cycles/min (±1% accuracy) |
| Stroke Length | 20–300 mm (±0.01 mm precision) |
| Pump Flow Rate (AB6000 only) | 0.0–3.0 mL/min |
| Max Sample Dimensions | 350 × 70 × 35 mm |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Display | 480 × 272 px TFT color touchscreen |
| Supported Languages | English, Spanish, German, French, Italian, Polish, Russian, Japanese, Chinese |
| Weight | 30–35 kg |
| Compliance | ASTM D2486, D4213, D4828, D3450, F1319 |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GV Cat Can Friction Tester |
| Pricing | Upon Request |
| Brand | TQC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TQC SP1100 Destructive Dry Film Thickness Gauge |
| Pricing | Upon Request |
| Construction Material | Aluminum-Titanium Alloy |
| Cutting System | Triple Stainless Steel Blade + Cross-Cut Blade |
| Microscope Integration | LED-Illuminated Eyepiece with Grid Reticle |
| Camera Adapter Compatibility | Digital Cameras with Lens Diameter < 42 mm |
| Adapter Dimensions | Ø 48 mm × H 14 mm |
| Adapter Weight | 60 g |
| Included Accessories | Camera Adapter, Calibration Set, Belt Clip |
| Brand | TQC |
|---|---|
| Model | VF2200/2201 |
| Compliance | ISO 7783, ASTM D1653, ASTM E96 |
| Construction | Stainless Steel Body with Precision-Machined Sealing Surfaces |
| Cup Volume | 10 mL |
| Sealing Ring Material | FDA-Compliant Silicone Elastomer |
| Cleaning | Autoclavable & Solvent-Compatible |
| Sample Compatibility | Self-Supporting and Non-Self-Supporting Films |
| Brand | TQC |
|---|---|
| Construction | Stainless Steel & Anodized Aluminum Body |
| Bearing Type | Precision Ball Bearing |
| Measurement Principle | Eccentric Rolling Wheel (ISO 2808 Compliant) |
| Scale Range | VF2255 (1–100 µm), VF2256 (5–250 µm), VF2257 (10–500 µm) |
| Graduation Accuracy | ±2 µm (per ISO 2808 Annex B) |
| Wheel Diameter | 42 mm |
| Compliance | ISO 2808, ASTM D1212, JIS K 5600-1-4 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | ZWLLX |
| Pricing | Upon Request |
| Brand | Heraeus Noblelight (ex-Hönel) |
|---|---|
| Origin | Germany |
| Model | UVACUBE 100 |
| Power Range | 100–2000 W |
| Lamp & Filter Configurability | Yes |
| Safety Interlock | Integrated Light-Tight Door & Shutter |
| Optional | Motorized Height-Adjustable Workbench |
| Compliance | CE, IEC 60598, IEC 62471 (Photobiological Safety) |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | SUPER 30 D |
| Counting Principle | Rotary Disc-Based |
| Maximum Counting Speed | 5,000 sheets per minute (spm) |
| Counting Range | 50–9,999 sheets per batch |
| Maximum Stack Height | 150 mm |
| Paper Grammage Range | 60–210 gsm |
| Sheet Size Range (Min–Max) | 90 mm × 45 mm to 200 mm × 100 mm |
| Noise Level | ≤78 dB(A) |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Net Weight | 105 kg |
| Data Interface | RS232 |
| Optional Features | Label Insertion Unit, Label Printer, Embossing Module, Acoustic/Visual Alarm, Extended 1000 mm Depth Worktop |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | SUPER 30 PB |
| Counting Principle | Blade-Actuated (Blade-Pick) |
| Maximum Counting Speed | 3,000 sheets per minute (spm) |
| Counting Speed with Flag Insertion | 2,500 spm |
| Batch Count Range | 50–9,999 sheets |
| Max Stack Height | 230 mm |
| Paper Basis Weight Range | 25–240 gsm |
| Sheet Size Range (Max/Min) | 1,050 mm × 800 mm / 297 mm × 210 mm |
| Noise Level | ≤78 dB(A) |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Net Weight | ~400 kg |
| Compliance | CE-marked, meets EN 61000-6-2 (EMC Immunity) and EN 61000-6-4 (EMC Emission) standards |
| Optional Features | Flag insertion unit, RS232 data export interface, audible/visual alarm, label printer integration, deep worktop (1000 mm), embossing module |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | Vicount 3 D |
| Counting Principle | Rotary Disc |
| Counting Speed | 5,000 sheets per minute (spm) |
| Counting Speed with Flag Insertion | 3,000 spm |
| Cycle Counting Time | 4–5 × 500 sheets / 60 seconds |
| Paper Grammage Range | 60–210 gsm (with 3 interchangeable discs) |
| Minimum Sheet Size | 60 mm × 110 mm (smaller formats available with optional accessories) |
| Maximum Stack Height | 150 mm |
| Batch Count Range | 5–9,999 sheets |
| Cumulative Total Capacity | 999,999 sheets |
| Noise Level | ≤78 dB(A) |
| Base Dimensions (Standard) | 600 mm × 400 mm |
| Base Options | Medium (760 × 760 mm, Airfloat), Large (1060 × 760 mm, Airfloat), Industrial (2040 × 800 mm, Airfoat) |
| Net Weight | Approx. 200–230 kg (varies by base configuration) |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | Vicount 3 PB BT |
| Counting Principle | Flap-type (flapper-based sheet separation) |
| Maximum Counting Speed | 2,500 sheets per minute (spm) |
| Counting Mode | Batch & Continuous |
| Sheet Weight Range | 25–200 gsm |
| Minimum Sheet Size | 60 mm × 110 mm |
| Maximum Stack Height | 220 mm |
| Batch Count Range | 5–9,999 sheets |
| Total Accumulated Count Capacity | 999,999 |
| Noise Level | ≤78 dB(A) |
| Tabletop Dimensions | 600 mm × 400 mm |
| Net Weight | Approx. 200 kg |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | Vicount 3 PB |
| Counting Principle | Blade-Feed |
| Counting Speed | 2,500 sheets per minute (spm) |
| Counting Speed with Flag Insertion | 2,500 spm |
| Cycle Time | 3 × 500 sheets / 60 seconds |
| Paper Weight Range | 25–200 gsm |
| Minimum Sheet Size | 60 mm × 110 mm |
| Maximum Stack Height | 220 mm |
| Batch Count Range | 5–9,999 |
| Total Accumulated Count | Up to 999,999 |
| Noise Level | ≤78 dB(A) |
| Tabletop Dimensions | 600 mm × 400 mm |
| Net Weight | Approx. 200 kg |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Model | Vicount 3 PB FS |
| Counting Principle | Flap-type (flap-assisted vacuum separation) |
| Maximum Counting Speed | 2,500 sheets per minute (spm) |
| Counting Speed with Insert Marking | 2,500 spm |
| Cycle Time | 3 × 500 sheets / 60 seconds |
| Paper Weight Range | 25–240 gsm |
| Minimum Sheet Size | 60 mm × 110 mm (smaller sizes require optional accessories) |
| Maximum Stack Height | 220 mm |
| Batch Count Range | 5–9,999 sheets |
| Cumulative Total Capacity | 999,999 sheets |
| Noise Level | ≤78 dB(A) |
| Tabletop Dimensions (Standard) | 600 mm × 400 mm |
| Power Supply | 230 V / 50 Hz or 115 V / 60 Hz |
| Net Weight | Approx. 200 kg (varies with table configuration |
| Brand | Vacuumatic |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vicount 4D |
| Pricing | Upon Request |