Packaging Industry Specialized Instruments
Filter
Showing 931–960 of 1185 results
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Category | Packaging Industry–Specific WVTR Tester |
| Test Principle | Gravimetric Cup Method (ASTM E96 Desiccant Method) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g |
| Temperature Control | 15–55 °C, ±0.1 °C |
| Humidity Control | 10–98% RH, ±1% RH |
| Test Area | 33 cm² |
| Sample Thickness Limit | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | AC 85–264 V, 47–63 Hz |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Net Weight | 83 kg |
| Compliance | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 72,000 (based on configuration and regional duties) |
| Test Principle | Gravimetric cup method (weight gain/loss measurement) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Quantity | 1–3 independent cups |
| Test Accuracy | ±0.01 g/m²·24h |
| System Resolution | 0.0001 g |
| Temperature Control Range | 15–55 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 10–98 %RH (standard 90 %RH) |
| RH Stability | ±1 %RH |
| Sweep Air Velocity | 0.5–2.5 m/s (optional) |
| Test Area | 33 cm² |
| Max. Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions (L×W×H) | 580×680×470 mm |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Type | Gravimetric Cup Method WVTR Tester |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Airflow Velocity | 0.5–2.5 m/s |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | W3/031 |
| Price Range | USD 28,000 – 56,000 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Specimen Size | Φ74 mm |
| Number of Test Stations | 3 independent cups |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Power Supply | AC 85–264 V, 47–63 Hz |
| Power Consumption | 600 W |
| Net Weight | 83 kg |
| Dimensions (L×W×H) | 580×680×470 mm |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55°C (±0.1°C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Cup Capacity | 3 independent cups |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.0001 g |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Model | W3/031-PERME |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Type | Gravimetric Cup Method WVTR Tester |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W3/062 |
| Test Principle | Gravimetric Cup Method (Weight Loss/Gain) |
| Measurement Range | 0.1–10,000 g/m²·24h (weight loss mode) |
| Sample Capacity | 1–6 independent specimens per test cycle |
| Temperature Control | 15–55 °C (±0.1 °C accuracy) |
| Humidity Control | 10–98% RH (±1% RH accuracy) |
| Test Area | 33 cm² |
| Specimen Thickness Limit | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance Standards | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Measurement Principle | Gravimetric Cup Method (Weight Change) |
| Test Range | 0.1–10,000 g/m²·24h (Loss Mode), 0.1–2,500 g/m²·24h (Gain Mode) |
| Sample Capacity | 1–6 independent specimens per run |
| Temperature Control | 15–55°C ±0.1°C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance | GB/T 17146, GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, DIN 53122-1, JIS Z0208, TAPPI T464, YBB00092003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | W3/062 |
| Test Principle | Gravimetric Cup Method (ASTM E96, ISO 2528, GB 1037) |
| Measurement Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens per test cycle |
| Temperature Control | 15–55 °C ±0.1 °C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Thickness Limit | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Principle | Gravimetric Cup Method (Weight Gain/Loss) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens simultaneously |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Measurement Principle | Gravimetric Cup Method (ASTM E96 / ISO 2528) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/062-PERME |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application Category | Packaging & Medical Film Barrier Testing |
| Test Principle | Gravimetric Cup Method (ASTM E96, GB 1037, ISO 2528) |
| Measurement Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens per test cycle (independent channels) |
| Temperature Control | 15–55 °C ±0.1 °C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| WVTR Resolution | 0.01 g/m²·24h |
| Air Supply | 0.6 MPa, Φ6 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | XLW |
| Type | Heat Seal Strength Tester / Universal Tensile & Peel Tester |
| Capacity Options | 100 N, 200 N, 500 N |
| Accuracy Class | Class 1 (per ISO 7500-1) |
| Test Speeds | 50–500 mm/min (7 discrete settings) |
| Standard Jaw Width | 30 mm |
| Optional Jaw Width | 50 mm |
| Maximum Travel | 600 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | 65 kg |
| Dimensions (L×W×H) | 450 × 450 × 980 mm |
| Compliance | ASTM F88, ASTM F904, ISO 37, GB/T 2792, GB/T 8808, QB/T 2358, and 15+ additional international and national standards |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | XLW Tensile Tester |
| Price Range | USD 4,200 – 8,400 |
| Load Capacity Options | 100 N / 200 N / 500 N |
| Accuracy Class | Class 1 |
| Test Speeds | 50–500 mm/min (7 discrete settings) |
| Standard Jaw Width | 30 mm |
| Optional Jaw Width | 50 mm |
| Maximum Travel | 600 mm |
| Dimensions (L×W×H) | 450 × 450 × 980 mm |
| Compliance Standards | YBB00152002, GB 13022, GB 8808, GB 1040, ASTM F88, ASTM F904, ISO 37, JIS P8113, QB/T 2358 |
| Brand | Labthink |
|---|---|
| Model | XLW(PC) |
| Type | Universal Electronic Tensile & Tear Tester |
| Standards Compliance | ISO 37, ASTM D1938 (Pant Tear), ASTM D882 (Tensile), ASTM F88 (Seal Strength), GB/T 1040, GB/T 16578.1, GB/T 12914, QB/T 2358 |
| Load Capacity | 50–1000 N (standard 500 N) |
| Accuracy Class | 0.5 |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Stroke | 1000 mm |
| Specimen Width | 30 mm (standard), 50 mm (optional) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 450 × 450 × 1410 mm |
| Net Weight | 68 kg |
| Control System | Microprocessor-based with PVC membrane keypad and large LCD display |
| Data Interface | Lystem™ Laboratory Data Sharing System compatible |
| Safety Features | Limit switch protection, overload cutoff, automatic return, power-loss memory |
| Brand | Lloyd Instruments |
|---|---|
| Origin | USA |
| Model | FT1 |
| Load Capacity | 1 kN |
| Crosshead Travel | 500 mm |
| Speed Range | 0.05–2032 mm/min |
| Speed Accuracy | <0.2% (steady-state) |
| Force Sensor Accuracy | <0.5% |
| Extension Resolution | <2 µm |
| Data Sampling Rate | 8 kHz |
| Sensor Options | YLC Series (10 N, 50 N, 100 N |
| Standards Compliance | ASTM D1894, ISO 8295, TAPPI T549 |
| Onboard Test Methods | 3 preconfigured (static/kinetic COF, peak/average force) + 7 user-defined |
| Data Storage | Up to 600 test records |
| Brand | Mecmesin |
|---|---|
| Origin | United Kingdom |
| Model | FPT-H1-i |
| Compliance | BS EN ISO 8295, ASTM D1894, ISO 15359, TAPPI T 549, FINAT 1–3, AFERA 5001, ASTM D3330, ASTM D6252, ASTM F88, BS EN 868-5, BS EN 1895, BS EN 1939, ISO 8510-2, PSTC 101, ASTM D1004, ASTM D1938-08, BS EN ISO 6383-1, BS EN ISO 12625-12 |
| Software | Emperor™ v5.x (Windows-compatible, 1 kHz data acquisition, SPC-ready export) |
| Certification | CE-marked, ISO 9001-manufactured |
| Test Modes | Static & kinetic COF, 90°/180°/T-peel, trouser & Elmendorf-style tear |
| Max Load Capacity | 500 N (standard), optional 1 kN |
| Resolution | 0.01 N (force), 1 µm (displacement) |
| Reporting | Automated PDF generation, Excel export, audit-trail enabled |
| Brand | Messmer Buchel |
|---|---|
| Origin | Netherlands |
| Model | 58-06 |
| Test Pressure Range | 490–5000 kPa (adjustable) |
| Standard Test Pressure | 1980 kPa |
| Measurement Range | 0.2–6.5 µm (normal mode) |
| Measuring Ring Width | 51 µm |
| Measuring Ring Circumference | 10.0 cm |
| Clamping Pressure Options | 500 / 1000 / 2000 kPa (100–5000 kPa fully adjustable) |
| Air Permeability Range (optional) | 0–10000 mL/min |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz |
| Compressed Air Requirement | 600 kPa, clean and dry |
| Dimensions (L×W×H) | 558 × 430 × 380 mm |
| Weight | 39 kg |
| Data Output | RS-232 or thermal printer |
| Compliance | GB/T 2679, ISO 8791-4, TAPPI T555 |
| Brand | Micro Support |
|---|---|
| Origin | Japan |
| Model | AXIS Pro |
| Type | Automated Precision Micro-Sampling Instrument for Cross-Sectional and Surface Sampling in Materials Analysis |
| Application Domain | Packaging, Display Materials, Semiconductor Packaging, Failure Analysis, and Electron Microscopy Sample Preparation |
| Brand | Micro Support |
|---|---|
| Origin | Japan |
| Model | Axis Pro Series |
| Category | Packaging Industry Specialized Instrument |
| Type | Automated Micro-Sampling & Sample Preparation System |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Software Interface | Windows-based control with motorized stage positioning and tool actuation logging |
| Tool Compatibility | Modular tool bay supporting interchangeable micro-probes, ruby knives, ultrasonic milling heads, vacuum micro-suction nozzles, electro-mechanical micro-tweezers, and precision micro-cutting blades |
| Positioning Resolution | Sub-micron XYZ stage repeatability (typical ±0.5 µm) |
| Operating Environment | Cleanroom-compatible (Class 1000 or better), vibration-isolated bench recommended |
| Data Traceability | Audit-trail enabled operation logs (aligned with GLP/GMP documentation requirements) |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | PW-6609A |
| Price | Upon Request |
| Max. Load Capacity | 10 kN |
| Force Resolution | 1 N |
| Force Accuracy | ±2% FS (indicated value error), ≤2% repeatability, ±0.2% FS return-to-zero error |
| Deformation Measurement Accuracy | ±1 mm |
| Preload Stability in Stack Test | ±4% |
| Compression Speed Range | 5–90 mm/min (±3% accuracy within range) |
| Standard Compression Speed | 12 mm/min |
| Stack Tracking Speed | 5 mm/min |
| Upper Platen Travel | 800 mm |
| Test Chamber Dimensions (W×D×H) | 600 × 800 × 800 mm |
| Parallelism Between Platens | ≤1 mm |
| Communication Interface | RS-232 (software optional) |
| Overall Dimensions (L×W×H) | 800 × 1000 × 1350 mm |
| Net Weight | ~250 kg |
| Compliant Standards | GB/T 4857.3, GB/T 4857.4, QB/T 1048, ISO 2872, ISO 2874 |
| Brand | MOCON |
|---|---|
| Origin | Germany |
| Model | AQUATRAN 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Temperature Control Range | 20–40 °C ± 0.2 °C |
| RH Control | 50–90% RH ± 3% RH & 100% RH |
| Test Area (Standard) | 50 cm² |
| Unshielded WVTR Range | 0.05–100 g/(m²·day) |
| Shielded WVTR Range | 0.5–1000 g/(m²·day) |
| Resolution | 0.02 g/(m²·day) |
| Repeatability | ±0.05 g/(m²·day) or ±2%, whichever is greater |
| Dimensions | 39.4 × 30.4 × 58.0 cm |
| Weight | 43.1 kg |
| Power | 100–240 VAC, 50/60 Hz, ≤700 VA |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Measurement Range | 0.05–200 g/(m²·day) |
| Test Chambers | 4 independent horizontal dual-membrane chambers |
| Compliance | ASTM F1249 |
| Sensor Type | Modulated Infrared (Patented MOCON) |
| Environmental Control | Automated temperature, RH, and N₂ flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Software Interface | Local PC GUI or optional touchscreen HMI |
| Test Mode Options | QC pass/fail mode, reference film validation, triplicate testing |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/40 |
| Detection Limit | 0.000025 g/(pkg·day) |
| Test Chambers | 4 independent |
| Temperature Range | 10–50 °C |
| RH Range | 30–90 % RH |
| Sensor Type | Modulated Infrared (ASTM F1249 compliant) |
| Automation | Fully automated T/RH/flow control, motorized test cartridge exchange, integrated conditioning & purge |
| Interface | Touchscreen HMI with real-time parameter monitoring |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN® Model 3 |
| Test Range (Film) | 0.00005–5 g/m²·day |
| Test Range (Container) | 0.00000025–0.025 g/pkg·day |
| Resolution | 0.00001 g/m²·day |
| Repeatability | ±0.00005 g/m²·day |
| Temperature Range | 5–50 °C (±0.2 °C at 100% RH) |
| Humidity Range (Detector Gas) | 5–90% RH & 100% RH |
| (Carrier Gas) | Dry |
| Test Chamber Options | Dual 50 cm² chambers |
| Compliance | ASTM F3299, ISO 15106-3, GB/T 21529-2008, YBB00092003-2015 |
| Brand | MOCON / Dansensor |
|---|---|
| Origin | Denmark |
| Model | CheckMate 4 |
| Measurement Gases | O₂ only or O₂ + CO₂ dual-sensor configuration |
| Detection Principle | Electrochemical (O₂) and Infrared (CO₂) |
| Sample Volume Required | < 2 mL |
| Data Storage Capacity | Up to 1,000,000 test records |
| User Profiles | Configurable individual logins with role-based access |
| Interface | 7-inch capacitive multi-touch LCD (English, Spanish, French, German, Chinese, Portuguese, Russian) |
| Connectivity | Ethernet (LAN), USB 2.0 (for barcode scanner, keyboard, printer, or data export via USB drive) |
| Sensor Module Design | Field-replaceable, pre-calibrated modular sensors |
| Compliance | Designed to support GLP/GMP environments |
| Calibration | Factory-calibrated |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |