Physical Property Testing Instruments
Filter
Showing 8041–8070 of 12427 results
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | PIP9.1 |
| Pricing | Available Upon Request |
| Measurement Principle | Digital Microscopy-Based Image Analysis |
| Test Range | 0.5–3000 µm |
| Repeatability Error | <3% |
| Output Data | Particle Size Distribution Table & Curve (by Equivalent Area Circle, Equivalent Short Diameter, etc.), Roundness Distribution Table & Curve, D10/D50/D90, Specific Surface Area (calculated), Mean Roundness, Roundness Range, Segment-Averaged Roundness, Representative Single-Particle Images |
| Core Hardware | Olympus Biological Microscope (Japan), 1.3 MP CMOS Sensor, USB 2.0 Interface |
| Key Automation | Auto-Focus, Auto-Field Scanning, Auto-Illumination Adjustment |
| Compliance Context | Aligns with GB/T 6408–2008 (Diamond Micropowder Standard), Supports GLP Documentation Workflow |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PT-01S |
| Pricing | Available Upon Request |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Measurement Principle | Coulter Principle (Electrical Sensing Zone) |
| Particle Size Range | 1–256 µm |
| Repeatability Error | <2% |
| Analysis Time | 15 seconds per sample |
| Channel Resolution | 8192 channels |
| Output Parameters | Particle size distribution table & curve, D10/D50/D90, mean diameter, median diameter, standard deviation, coefficient of variation, specific surface area, total particle count |
| Key Hardware Features | Discrete measurement cell + PC-based acquisition architecture, high-precision pulse peak detection circuitry, solid-state pressure sensor for vacuum control, optoelectronic liquid level sensing, automated aperture clearing function |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RC-2200 |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Standard Compliance | GB/T 29025–2012, ISO 13319-1:2021 |
| Measurement Principle | Aperture Impedance (Coulter Principle) |
| Dynamic Range | 0.6–256 µm (down to 0.4 µm under optimal conditions) |
| Channel Resolution | 8192 detection channels |
| Repeatability | ≤1% (D₅₀ deviation on certified reference material) |
| Pulse Latency | 5 µs |
| Signal-to-Noise Ratio | 140 dB |
| Sample Introduction | Electrolyte-diluted suspension, stir-or-static mode |
| Sampling Control Modes | Fixed time / Fixed volume / Fixed particle count |
| Test Duration | ~15 s (typical) |
| Data Output | Size distribution table & curve, D₁₀/D₅₀/D₉₀, mean diameter, standard deviation, coefficient of variation, specific surface area, total particle count, frequency histogram |
| Power Supply | 200–240 V AC, 50 Hz |
| Dimensions (W×D×H) | 300 × 370 × 450 mm |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electrical Resistance (Coulter) Particle Counter |
| Model | RC-3000 |
| Measurement Principle | Coulter principle (electrical sensing zone) |
| Particle Size Range | 1–256 µm |
| Repeatability Error | <2% |
| Analysis Time | 15 s per sample |
| Channel Resolution | 8192 channels |
| Output Parameters | Particle size distribution table & curve, D10/D50/D90, mean diameter, standard deviation, coefficient of variation, specific surface area, total particle count |
| Key Hardware | ARM-based integrated architecture, precision pulse peak detection circuitry, digital pressure sensor for vacuum control, optoelectronic liquid level sensing, automated aperture clearing system, auto-balancing conductivity compensation circuit |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TD-01 / TD-02 / TD-03 |
| Instrument Type | Tap Density Tester |
| Measurable Powder Parameter | Bulk and Tapped Density |
| Maximum Sample Vessel Capacity | 250 mL |
| Minimum Sample Volume | 25 mL |
| Vibration Amplitude Range | 1–15 mm (integer steps) |
| Vibration Frequency Range | 0–300 taps/min (continuously adjustable) |
| Tap Count Range | 0–99,999 (0 = bulk density mode) |
| Power Supply | AC 220 V ±10%, 50 Hz, 40 W |
| Operating Humidity | <85% RH, non-condensing |
| Ambient Requirements | Vibration- and EMI-free environment, dust-free clean space |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Topsizer |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.02–2000 µm (wet), 0.1–2000 µm (dry) |
| Repeatability | ≤0.5% (D50 of standard reference material) |
| Measurement Time | ≤10 s (typical) |
| Optical Principle | Full-range Mie scattering theory |
| Detector Channels | 98-channel 3D detection system (forward, side, large-angle, and backward scattering) |
| Scattering Angle Range | 0.016°–140° |
| Dual Light Sources | He-Ne laser (632.8 nm) + blue semiconductor laser (466 nm) |
| Laser Stability | Power fluctuation <0.5%, polarization ratio >500:1, TEM₀₀ mode >95% |
| Optical Platform | Monolithic high-precision aluminum alloy base |
| Optical Design | Sealed linear optical path with post-Fourier single-lens transformation |
| Fourier Lens Focal Length | Extended for enhanced large-particle sensitivity |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 and GMP Annex 11 requirements for computerized systems (user roles, audit trail, electronic signatures, data integrity) |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Topsizer Plus |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3600 µm (wet), 0.1–3600 µm (dry) |
| Repeatability | ≤0.5% RSD (D50 of standard reference material) |
| Measurement Time | ≤10 seconds per analysis |
| Brand | OMECC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LS-609 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | <1% (D50 deviation of certified reference material) |
| Measurement Time | 1–2 minutes |
| Light Source | Imported He-Ne laser, λ = 632.8 nm, output power >2.0 mW |
| Detection Channels | 49 independent photodetectors |
| Scanning Frequency | 1 kHz |
| Alignment Accuracy | ±0.5 µm (intelligent auto-alignment) |
| Environmental Operating Conditions | 5–35 °C, RH <85% |
| Data Output | Particle size distribution table & curve, D10/D50/D90, specific surface area, span, etc. |
| Dimensions (L×W×H) | 838×265×295 mm (main unit) |
| Brand | OMECK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DS-1000 |
| Pricing | Upon Request |
| Application Field | General Particle Characterization |
| Instrument Type | Dynamic |
| Lens Count | Lensless Imaging System |
| Measurement Range | 1.4–1400 µm |
| Dispersion Method | Wet Dispersion |
| Image Resolution | 2 Megapixels |
| Primary Measured Parameter | Equivalent Projected Area Diameter (D<sub>EA</sub>) |
| Brand | OMECK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | NS-90 Plus |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ≤ 1% (NIST-traceable latex standards) |
| Temperature Control Range | 0 – 120 °C |
| Temperature Stability | ±0.1 °C |
| Detection Angle | 90° |
| Measurement Principle | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS) |
| Minimum Sample Volume | 20 µL |
| Sample Concentration Range | ≤ 1 mg/mL (sample-dependent) |
| Measurement Time (per sub-run) | 1.68 s |
| Molecular Weight Range (DLS-derived) | 980 – 2×10⁷ Da |
| Molecular Weight Range (SLS Debye plot) | 342 – 2×10⁷ Da |
| Laser Source | He-Ne gas laser, 632.8 nm, 4 mW |
| Detector | Avalanche Photodiode (APD), QE ≥ 80% @ 632.8 nm |
| Correlator | >4000 channels, 10¹¹ linear dynamic range, minimum sampling interval: 25 ns |
| Compliance | CFDA GMP Annex on Computerized Systems (audit trail, role-based access control, electronic signature) |
| Brand | OMECK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | NS-90Z Plus |
| Quotation | Upon Request |
| Zeta Potential Range | No Practical Limit |
| Operating Temperature Range | 0–120 °C |
| Repeatability | ≤1% (NIST-traceable latex standard) |
| Brand | OMECK/OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PT-01 |
| Pricing | Available Upon Request |
| Brand | Omnion |
|---|---|
| Origin | USA |
| Model | OSI-6 |
| Temperature Range | 40–200 °C |
| Sample Capacity | 6 positions (expandable to 12 or 18) |
| Data Channels | 24 simultaneous real-time monitoring channels |
| Measurement Principle | Oxygen uptake via conductometric detection of peroxide formation during accelerated oxidation |
| Compliance | ASTM D5768, AOCS Cd 12b-92, ISO 6886 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | OmniScan SX Phased Array Instrument |
| Portability | Portable |
| Pulse Type | Negative Square Wave Pulse (Adjustable) |
| Application Fields | Aerospace, Oil & Gas, Power Generation, Pipeline & Pressure Vessel Inspection |
| Compliance | ASTM E2700, ISO 13588, ASME BPVC Section V, API RP 2X, EN 1330-4, EN 12668-1/2/3 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | OmniScan X3 |
| Portability | Portable |
| Pulse Type | Negative Square Wave Pulse |
| IP Rating | IP65 |
| Compliance | ISO 18563‑1:2015, EN12668‑1:2010 |
| PA Configuration | 16:128PR or 32:128PR |
| TFM Support | Up to 64-element aperture |
| FMC Capacity | Full Matrix Capture enabled |
| Onboard File Capacity | 4 GB |
| Internal Storage | 64 GB SSD |
| Display | 10.6-inch WXGA TFT-LCD (1280 × 768), 16M colors |
| Weight | 5.7 kg (with one battery) |
| Operating Temperature | −10 °C to 45 °C |
| Battery Runtime | 5 hours (dual hot-swappable Li-ion, 93 Wh each) |
| GPS | Integrated |
| Encoders | Dual-axis quadrature or clock/direction |
| UT Channels | 2 independent P/R channels |
| PA Channels | 16 or 32 active elements, 128 receiver channels |
| Max Focusing Laws | 1024 per setup |
| TCG Points | 32 per focusing law |
| System Bandwidth | PA: 0.5–18 MHz |
| UT | 0.25–28 MHz |
| Pulse Width Range | PA: 30–500 ns (2.5 ns step) |
| UT | 30–1000 ns (2.5 ns step) |
| Max PRF | 12 kHz |
| A-scan Height Range | up to 800% |
| Data Acquisition | 16-bit digitization |
| Real-time Averaging | PA: 2/4/8/16 |
| UT | 2/4/8/16/32/64 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | OmniScan X4 |
| Portability | Portable |
| Application Domain | Aerospace |
| Category | Phased Array TOFD Flaw Detector |
| Compliance Context | Meets ASTM E2700, ISO 16810, and EN 13588 requirements for phased array ultrasonic testing (PAUT) and time-of-flight diffraction (TOFD) inspection |
| Brand | Omnitek |
|---|---|
| Origin | Netherlands |
| Model | U-Visc Series |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Viscosity Range | 0.15–25,000 mm²/s |
| Temperature Range | 15–150 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating Rate | 4 °C/min |
| Standards Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, GB/T 265, GB/T 30515, GB/T 11137 |
| Sample Volume | 8–16 mL |
| Autosampler Capacity | 32 positions (dual 16-position rotating carousel, one per capillary) |
| Timing Resolution | 0.001 s |
| Cleaning System | Dual-solvent (high-dissolving + high-volatility), corrosion-resistant fluidic path, vacuum-assisted waste evacuation |
| Environmental Control | Sealed autosampler chamber with negative-pressure waste collection |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | Vega, Nova II, LaserStar, Nova, Orion, BeamTrack |
| Interface Options | USB, RS232, GPIB, Analog Output (1V/2V/5V/10V), Trigger I/O |
| Sampling Rates | Up to 250 kHz (Vega), 2 kHz (Nova II/LaserStar), 1.5 kHz (LaserStar), 10–30 Hz (Nova/Orion) |
| Data Storage | On-device real-time logging, PC-based active storage via USB |
| Software Support | Ophir StarLab v3.x, LabVIEW VIs, ActiveX Controls, FDA 21 CFR Part 11-compliant audit trail (optional), GLP/GMP-ready reporting |
| Detector Compatibility | Thermopile, Photodiode, Pyroelectric, RP (Radiation Pressure), BeamTrack (position & beam diameter) |
| Brand | Stanford |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | +10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Temperature Resolution | 0.1 °C |
| Power Supply | AC 90–264 V |
| Weight | 4.1 kg |
| Operating Ambient | 0–40 °C |
| Interface | USB, RS-232 |
| Software | MeltView (Windows-compatible) |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | SRV®5 |
| Instrument Type | Reciprocating Tribometer |
| Maximum Friction Force | 2500 N |
| Friction Force Resolution | 1 N |
| Operating Temperature Range | −35 °C to 1000 °C |
| Motion Modes | Reciprocating, Rotational, Tilted (0°–90°), Oscillatory, Non-Continuous Transition |
| Optional Modules | FSA (Friction Signal Analysis), Vacuum Chamber (High Vacuum), Nanopositioning Stage, Electrical Resistance Monitoring, Custom Fixture Integration |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Industrial |
| Pricing | Upon Request |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Model | Infrared Type |
| Measurement Principle | Photothermal (Light-Heat) Method |
| Compliance | DIN EN 15042-2 |
| Thickness Range | 1–300 µm |
| Spot Size | Ø 1 mm |
| Measurement Distance | ≈35 mm |
| Repeatability | ≤1 Hz |
| Measurement Time | 32–2048 ms |
| Accuracy | ±3% of reading |
| Resolution | ~1% of reading |
| Angular Tolerance | ±15° |
| Probe Dimensions | L 160 × W 50 mm |
| Probe Weight | 200 g |
| Terminal Dimensions | 80 × 180 × 42.5 mm |
| Total Device Weight | 750 g |
| Power Supply | 4 rechargeable Li-ion batteries |
| Battery Life | Up to 10 hours continuous operation |
| Interface | USB |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Model | Automatic |
| Measurement Principle | Photothermal (Laser-Based Non-Contact) |
| Standards Compliance | DIN EN 15042-2 |
| Max. Measuring Range | 0–300 µm (on metallic substrates), 0–60 µm (on non-metallic substrates) |
| Spot Size | Ø 0.5 mm |
| Measurement Distance | 16 mm ±1 mm |
| Angular Tolerance | ±15° |
| Laser Class | 1M (≤0.5 W peak pulse power) |
| Repetition Rate | up to 1 Hz |
| Measurement Duration | 8–512 ms |
| Resolution | ~3% of actual thickness |
| Accuracy | ~5% of actual thickness |
| Probe Weight | ~100 g |
| Terminal Dimensions | 227 × 267 × 100 mm |
| Terminal Weight | 2.2 kg |
| Power Supply | 230 V AC, 50 Hz, max. 40 W |
| Interface | 10 Mbps Ethernet (RJ45) |
| Brand | OptiSense |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpecEL |
| Pricing | Upon Request |
| Brand | Optrel |
|---|---|
| Origin | Germany |
| Model | Multiskop-CA |
| Type | Video-based Optical Contact Angle Measurement System |
| Integration | Modular add-on for Multiskop ellipsometry platform |
| Imaging | High-resolution CCD camera with programmable LED backlighting array |
| Sample stage | Motorized XYZ translation stage with thermal coupling capability |
| Analysis engine | Automated contour tracing algorithm based on Young–Laplace equation fitting |
| Compliance | Designed for ISO 19403-2, ASTM D7334, and ISO 21365-compliant surface energy evaluation workflows |
| Software | CAM (Contact Angle Module) with audit-trail-enabled data logging |
| Brand | ORONTEC |
|---|---|
| Origin | Germany |
| Model | MagnoMeter XRS |
| Instrument Type | Optical Particle Counter (NMR-based surface-sensitive particle analyzer) |
| Category | Particle/Powder Analysis Instruments |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ASTM E2457 (for NMR particle analysis methodology), ISO 13320 (laser diffraction) supplementary use case |
| Brand | ORONTEC |
|---|---|
| Origin | Germany |
| Model | Surface Scanner Automatic |
| Type | Modular Automated Coating Characterization System |
| Compliance | ISO 28199 Parts 1–3 |
| Max. Sample Size (Basic) | 600 × 300 mm |
| Max. Integrated Instruments | 4 |
| Power Supply | 230 VAC (Basic), 400 VAC (Large/Flexi) |
| Air Supply | 6 bar, oil-free and filtered |
| Weight | 400–700 kg |
| Software | PLC-controlled measurement orchestration with Excel-based reporting |
| Data Architecture | Local or intranet-deployable database |
| Brand | Ortelli |
|---|---|
| Origin | Italy |
| Model | MVS2pro |
| Instrument Type | Buoyancy-Based Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Solids (films, rods, granules) |
| Density Range | 0–2 g/cm³ |
| Temperature Control Range | 10–40 °C (standard test temp: 23 °C) |
| Cycle Time | ~3–5 min per sample |
| Auto-sampler Capacity | 16-position robotic arm |
| Compliance | ISO 1183-1, ISO 9001 |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | ANS800 Series |
| Max Operating Temperature | 800 °C or 1000 °C |
| Compliance | ASTM C336 |
| Temperature Control | PID-controlled, automated |
| Measurement Principle | LVDT-based fiber elongation monitoring under controlled cooling |
| Data Processing | Automated calculation of annealing point (AP) and strain point (SP) per ASTM C336 |
| Accuracy | ±1 °C (for glass fiber samples) |
| Software | Orton proprietary control & analysis suite with real-time plotting, statistical reporting, and audit-ready data logging |