| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JMP2000A |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Langmuir Trough Dimensions (Upper Chamber) | 70 mm × 150 mm × 8 mm (W × L × H) |
| Max Measurable Area | 96.6 cm² |
| Min Measurable Area | 19.32 cm² |
| Oscillation Frequency Range (Sinusoidal Mode) | 0.001–1 Hz |
| Area Strain Amplitude | 1–6% (relative to equilibrium area) |
| Relaxation Step Change | 5–30% area change in 1–2 s |
| Sampling Interval | 150–300 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | <150 W |
| Operating Temperature | Ambient |
| Operating Humidity | 30–85% RH |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JN01A |
| Zeta Potential Measurement Principle | Mass-Exchange Electrophoresis |
| Sample Concentration Range | High-concentration dispersions (undiluted, slurry-state) |
| pH Range | Not specified |
| Compliance | Designed for ASTM D4187, ISO 13099-2, and GLP-compliant workflows requiring raw-state dispersion analysis |
| Interface | RS232 (COM port) + USB |
| Software | JN01.exe (Windows XP / 32-bit Windows 7 compatible) |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94 |
| Measurement Principle | Microelectrophoresis (Video-Based Particle Tracking) |
| Compliance | GB/T 32668–2016 (National Standard for Colloidal Particle Zeta Potential Analysis – Electrophoretic Method) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Operating Temperature Range | Ambient to 35 °C |
| Zeta Potential Accuracy | Systematic error ≤5% |
| pH Range | 1.6–13.0 (typical operational range: 2.0–12.0) |
| Sample Volume per Test | 0.5 mL |
| Optical Magnification | Up to 1200× |
| Imaging System | USB Digital CCD with Customized Micrometer Grid Calibration |
| Electrode Configuration | Integrated Ag, Pt, and Ti/POM electrodes in open-cell electrophoresis chamber |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Temperature Compensation | Real-time thermistor-based ambient temperature sampling |
| Software Platform | Unified cross-model analysis suite with GLP-compliant data logging and audit trail capability |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixels/µm |
| System Accuracy | ±5% relative error (per GB/T 32668-2016 validation protocol) |
| Particle Size Applicability | 0.5–20 µm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H2-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixel/µm |
| Particle Size Range | 0.5–20 µm |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Compliance | GB/T 32668–2016 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94J-1K20X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| System Accuracy | ≤5% systematic error |
| Particle Size Applicability | 0.1–10 μm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94J2-1K20X |
| Zeta Potential Range | ±200 mV (typical, per GB/T 32668-2016 calibration protocol) |
| pH Range | 1.6–13.0 (standard operation: 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| Microscope System | WDK Japan high-magnification optical module, working distance 7 mm |
| System Accuracy | ≤5% relative error (per ISO 13099-2:2012 validation methodology) |
| Particle Size Applicability | 0.1–10 μm (aqueous & organic dispersions) |
| Power Consumption | <150 W, 220 V / 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K-3H20X |
| Zeta Potential Range | ±200 mV (typical, inferred per ISO 13099-2) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (measurement resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm (aqueous dispersions) |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K2-3H20X |
| Zeta Potential Range | ±200 mV (typical, system-limited) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (readout resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016 (General Rules for Zeta Potential Analysis of Colloidal Particles by Electrophoresis) |
| System Accuracy | ±5% relative error (per certified reference dispersions under controlled conditions) |
| Sample Volume per Measurement | 0.5 mL |
| Voltage Polarity Switching Interval | 0.30–1.20 s (adjustable) |
| Measurement Time per Cycle | 3–10 s |
| Light Source | Low-power semiconductor blue/green LED (non-thermal, near-field illumination) |
| Brand | POWEREACH |
|---|---|
| Model | NDJ-1 |
| Type | Analog Rotational Viscometer |
| Portability | Benchtop (with integrated stand) |
| Operating Environment | Ambient temperature (10–35 °C) |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard set includes #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±5% for Newtonian fluids |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions (W×D×H) | 400 × 370 × 150 mm |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-4 |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±5% (for Newtonian fluids) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions | 320 × 260 × 170 mm |
| Included Rotors | #1, #2, #3, #4 |
| Compliance | Designed for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-5S |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian liquids |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Compliance | Designed for GLP-compliant routine QC environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–1,000,000 mPa·s |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Accuracy | ±4% (for Newtonian fluids) |
| Dimensions (L×W×H) | 170 × 140 × 440 mm |
| Weight | 14 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Compliance | Designed for routine QC and R&D in industrial and academic labs per ISO 2555 and ASTM D2196 principles |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Spindle Set | Standard #1–#4 spindles (optional #0 spindle for down to 0.1 mPa·s) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian fluids |
| Display | Backlit LCD with real-time spindle/speed/viscosity/% full-scale readout |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | TX-500C |
| Measurement Range | 10⁻⁶–100 mN/m |
| Temperature Control Range | RT+5 °C to 95 °C |
| Temperature Display Range | 0–99.9 °C |
| Temperature Accuracy | ±0.1 °C |
| Image Capture | USB Digital CCD (60 fps, 752×480 px) |
| Rotation Speed | 1,000–10,000 rpm (±5 rpm control accuracy) |
| Spatial Resolution | 0.001 mm |
| Optical Readout Field | 0–6 mm |
| Interface | USB & RS-232 |
| Heating System | PID-Controlled Stainless Steel Electric Heater |
| Sample Tube Options | High-Purity Quartz Tubes (ID: 2 mm, 4 mm, 6 mm) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JC2000X |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JC2000F |
| Price Range | USD 7,000–14,000 |
| Instrument Category | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° or ±0.5° |
| Roll-off Angle Resolution | 0.2° |
| Sample Stage Dimensions | 70 mm × 70 mm |
| Optical Magnification | 0.7×–4.5× (continuous zoom) |
| Image Resolution | 50–318 pixels/mm |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Stage Translation | Manual X/Y/Z (50 mm × 50 mm × 45 mm, 0.1 mm resolution) |
| Droplet Dispensing Precision | ±0.1 µL |
| CCD | USB 2.0 industrial camera, 700 TV lines, 25 fps (optional high-speed upgrade available) |
| Illumination | Adjustable monochromatic LED cold light source |
| Software Capabilities | Advancing/receding angle tracking, left/right asymmetry analysis, Owens–Wendt surface energy calculation, curvature correction for convex/concave substrates |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JC2000P2 |
| Price Range | USD 7,000–14,000 |
| Instrument Category | Video Optical Contact Angle Meter |
| Form Factor | Portable |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.1° or 0.5° (selectable) |
| Sample Stage Dimensions | 100 × 100 mm (fixed) |
| Image Resolution | 800 × 600 pixels |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JC2000D2M |
| Price Range | USD 7,000–14,000 |
| Instrument Class | Video Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (θ/2 Method) |
| Sample Stage Dimensions | 70 × 70 mm |
| Optical Magnification | 0.7–5× (55–320 pixels/mm) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | JC2000D4M |
| Price Range | USD 7,000–14,000 |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Roll-Off Angle Resolution | 0.2° |
| Sample Stage Dimensions | 100 × 100 mm |
| Optical Magnification | 0.7–5× (55–320 pixels/mm) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JC2000DM |
| Price Range | USD 2,800–7,000 |
| Instrument Class | Video Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (θ/2 Method) |
| Sample Stage Dimensions | 100 × 70 mm |
| Optical Magnification | 0.7–5× (55–320 pixel/mm) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | JC2000X4EA |
| Price Range | USD 2,800–7,000 |
| Instrument Class | Video Optical Contact Angle Meter |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (θ/2 Method) |
| Fixed Sample Stage Dimensions | 100 mm × 100 mm |
| Optical Magnification | 0.7–5× (55–320 pixels/mm) |
| Surface/Interfacial Tension Range | 0–1000 mN/m |
| Brand | Pozhi Electronic |
|---|---|
| Origin | Shanghai, China |
| Model | RHEO1600 |
| Instrument Type | Fixed-Mount High-Temperature Viscometer |
| Operating Environment | High-Temperature Melt |
| Viscosity Range | 100–5,000,000 mPa·s |
| Temperature Range | 0–1700 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 0–50 °C/min |
| Compliance Standards | ASTM C965, GB/T 31424-2015 |
| Viscometer Core Module | DVNext-based torque transduction system |
| Sample Crucible Capacity | 40 mL |
| Atmosphere Options | Air, Inert Gas (N₂/Ar), Vacuum (10⁻² mbar and 10⁻⁴ mbar) |
| Crucible Material Options | Platinum (Pt), ODS-Pt (Oxide-Dispersion-Strengthened Platinum), Graphite, Molybdenum, Sintered Alumina |
| Brand | Pozhi Electronic |
|---|---|
| Origin | Shanghai, China |
| Model | RHEO1700 |
| Instrument Type | Fixed-Installation High-Temperature Viscometer |
| Temperature Range | 0–1700 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 0–50 °C/min |
| Viscosity Range | 0.01–40,000 Pa·s |
| Compliance | GB/T 31424–2015 |
| Atmosphere Options | Air, Inert (N₂/Ar), Reducing (CO/CO₂/H₂ mixtures), Vacuum |
| Rotational Speed Range | 0.01–250 rpm |
| Speed Steps | 2600 discrete settings |
| Measurement Principle | Rotational viscometry under controlled high-temperature atmosphere |
| Brand | Pozhi Electronic |
|---|---|
| Origin | Shanghai, China |
| Model | RHEO1700 |
| Instrument Type | Fixed-Base Rotational Viscometer |
| Operating Environment | High-Temperature |
| Viscosity Range | 100–5,000,000 mPa·s |
| Temperature Range | 0–1700 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 0–50 °C/min |
| Rotational Speed Range | 0.01–250 rpm |
| Compliance | ASTM C965, GB/T 31424–2015 |
| Calibration Standard | NIST SRM 717a Borosilicate Glass |
| Brand | Pozhi Electronic |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100–5,000,000 mPa·s |
| Temperature Range | 0–1700 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1 °C |
| Heating Rate | 0–50 °C/min |
| Compliance | ASTM C965, GB/T 31424–2015 |
| Viscosity Measurement Core | Brookfield DVNext Rheometer Platform |
| Atmosphere | Air |
| Calibration Standard | NIST-Traceable Standard Glass 717a |
| Key | Max Test Load: 80 kN |
|---|---|
| Test Frequency Range | 0–5 Hz |
| Frequency Accuracy | ±1% |
| Stroke Amplitude | 0–160 mm |
| Static Load Accuracy | ±0.5% |
| Position Resolution | ±0.1 mm |
| Cylinder Thrust Range | 0–8,000 kgf |
| Speed Range | 0.2–200 mm/min |
| Max Specimen OD | 600 mm |
| Max Specimen Height | 500 mm |
| Power Supply | AC 380 V, 100 kW |
| Waveform Options | Sine, Ramp, Square |
| Compliance Standard | GB/T 13061 |
| Key | Temperature Range: +100°C to +147°C (saturated steam temperature) |
|---|---|
| Humidity Range | 75–100% RH (saturated steam, up to 75% RH at 47°C) |
| Humidity Stability | ±3% RH |
| Operating Pressure | 1.2–2.89 kgf/cm² (inclusive of 1 atm ambient) |
| Time Setting Range | 0–999 hours |
| Pressurization Time | ~45 min to reach 1.04 kgf/cm² from ambient |
| Temperature Uniformity | ±0.5°C |
| Temperature Display Resolution | 0.1°C |
| Pressure Uniformity | ±0.1 kgf/cm² |
| Humidity Uniformity | ±3% RH |
| Internal Chamber Design Pressure Rating | 4.0 kgf/cm² |
| Vacuum Pre-Purge Function | Integrated |
| Safety Interlock | Dual-redundant pressure/temperature-sensing door lock |
| Water Autonomy | Up to 48 h continuous operation per fill (optional fully automated water replenishment system) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Load Capacity | 50–800 kg |
| Peak Acceleration | 30–1000 m/s² |
| Pulse Duration | 20–130 ms |
| Repetition Rate | 10–60 impacts/min |
| Table Surface Dimensions | 500×700 mm to 1000×1000 mm |
| Maximum Drop Height | 0–80 mm |
| Continuous Operation Time | 8 h |
| Power Supply | 220 VAC ±10% / 380 VAC ±10%, 50 Hz |
| Environmental Operating Range | –40 to +50 °C, Humidity <85% RH (at 25 °C) |
| Compliance Standards | GB/T 2423.5–1995, GB/T 2423.6–1995, IEC 60068-2-27, IEC 60068-2-29, JJG 497–2000 |
| Brand | Precision Eforming |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Precision Eforming |
| Pricing | Available Upon Request |
| Aperture Range | 3–2000 µm (1 µm increments) |
| Ultra-Precision Aperture Range | 2–500 µm (1 µm increments) |
| Base Material | Nickel |
| Compliance | ASTM E161, ISO 3310-3 |
| Tolerance | ±2 µm (Ultra-Precision: ±1.5 µm) |
| Aperture Shapes | Square, Round, Slotted, Custom Geometries |
| Sieve Diameters | 3", 8", 12" (stainless steel) |
| Support Grid | Stainless steel (optional or removable) |