| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | RiOs 30/50/100/150/200 |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | >10 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <30 ppb |
| Feed Water Conductivity | <2000 µS/cm @ 25°C |
| Feed Pressure | 2–6 bar |
| Minimum Flow Rate | >5 L/min @ 2 bar |
| Recovery Rate | Adjustable RO system with reject water recirculation |
| Brand | Millipore |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rios Essential |
| Price Range | USD 6,800–13,600 (est.) |
| Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | >0.05 MΩ·cm (at 25 °C) |
| Total Organic Carbon (TOC) | <200 ppb |
| Particulates (>0.1 µm) | Not Specified |
| Microbial Content | Not Specified |
| Heavy Metals & Soluble Silica | Not Specified |
| Ion Rejection Rate | >95% |
| Organic & Particle Rejection Rate | >99% |
| Flow Rates | 5 / 8 / 16 / 24 L/h (±15%, at 7–35 °C) |
| Daily Output Capacity | 30–480 L (model-dependent) |
| Recovery Rate | 25.0–44.4% (model-dependent) |
| Brand | Millipore |
|---|---|
| Origin | France |
| Model | Synergy UV |
| Production Flow Rate | 1.5 L/min |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | < 5 ppb |
| Particles > 0.22 µm | < 1/mL |
| Microbial Count | < 1 CFU/mL |
| Endotoxins | < 0.001 EU/mL |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| Electrode Material | 316L Stainless Steel |
| Noise Level | < 40 dB (at 1 m) |
| Integrated UV Lamp | Dual-Wavelength (185/254 nm) |
| Final Filtration | 0.22 µm Terminal Filter |
| System Monitoring | Real-time Resistivity & TOC Trending, Cartridge Life Algorithm, Auto-Recirculation, Dry-Run & Low-Water Protection |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Direct 8 / Milli-Q Direct 16 |
| Purification Technology | RO + Ion Exchange + Dual-Wavelength UV (185/254 nm) + Final Polishing Cartridge |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | ≤5 ppb |
| Bacteria | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| RNase | <0.01 ng/mL |
| DNase | <4 pg/mL |
| Recovery Rate (RO) | Up to 66% |
| Feed Water Temperature Compensation | Yes |
| Pre-treatment | Progard® Cartridge with Recirculating Reject Loop |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Integral |
| Production Capacity | 3, 5, 10, or 15 L/h (Pure Water) / Up to 2 L/min (Ultrapure Water) |
| Resistivity (Ultrapure) | 18.2 MΩ·cm @ 25 °C (temperature-compensated) |
| TOC (Ultrapure) | 1–5 ppb |
| Bacterial Count (Ultrapure) | <0.1 CFU/mL |
| Particles >0.22 µm (Ultrapure) | <1/mL |
| Endotoxin (with UF module) | <0.001 EU/mL |
| Resistivity (Pure Water) | 5–15 MΩ·cm @ 25 °C |
| TOC (Pure Water) | <30 ppb |
| Silica Rejection | >99.9% |
| Microbial Load (Pure Water) | <10 CFU/mL |
| Integrated Online TOC Analyzer | Range 1–999 ppb, Accuracy ±1 ppb |
| Conductivity/Resistivity Sensors | Four independent cells, Cell Constant 0.01 cm⁻¹, Temp. Sensitivity ±0.1 °C |
| Water Tank | 30 L, Conical Bottom, Air Filter with 0.22 µm Hydrophobic Membrane, Overflow Protection, Level Accuracy ±5% |
| System Interface | Full-color graphical display, Chinese-language OS, Real-time水质 & Maintenance Status |
| Connectivity | RS232, Ethernet |
| Data Logging | 12-month integrated audit trail |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q IQ 7000 |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | ≤2 ppb (µg/L), typical ≤5 ppb (µg/L) |
| Microbial Count | <0.01 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| RNase | <1 pg/mL |
| DNase | <5 pg/mL |
| Proteases | <0.15 µg/mL |
| Particles (>0.2 µm) | Zero particles >0.22 µm |
| Flow Rate | 0.05–2 L/min |
| Feed Water Conductivity | <100 µS/cm @ 25°C |
| Feed TOC | <50 ppb |
| Operating Pressure | 0.1–6 bar |
| Operating Temperature | 5–35°C |
| Brand | MilliporeSigma |
|---|---|
| Origin | France |
| Model | Milli-Q Reference |
| Flow Rate | 50–2000 mL/min |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | <5 ppb |
| Particles (>0.22 µm) | <1 particle/mL |
| Microbial Count | <0.1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| UV Lamps | Dual-wavelength (185 nm & 254 nm) |
| Conductivity Sensors | 2 built-in |
| Noise Level | <40 dB at 1 m |
| Display | LCD with Chinese interface |
| Data Logging | 12-month traceable water quality history |
| Compliance | ASTM D1193 Type I, NCCLS, CAP, GLP, ISO 9001/ISO 14001 certified |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-I |
| Distillation Temperature Range | 0–400 °C |
| Receiver Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Cold Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Heating Power | 0–1200 W (continuously adjustable) |
| Total Power Consumption | 2000 W |
| Input Voltage | 220 V ±10%, 50 Hz ±1 Hz |
| Display | 10.4″ integrated LCD touch screen |
| Interface Ports | USB, RS-232, Ethernet |
| Volume Measurement Points | 99 programmable recovery points |
| Refrigeration Method | Semiconductor cooling |
| Compliance | GB/T 6536–2010, ISO 3405, ASTM D86, IP 123, SY/T 5648 |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Model | SYP-7534B |
| Origin | Shanghai, China |
| Construction | Quartz-glass distillation apparatus |
| Cold Bath Temperature Control Range | −10 °C to +70 °C |
| Condensate Cylinder Temperature Control Range | −10 °C to +60 °C |
| Volume Detection Range | 0–100 mL (0.01 mL resolution) |
| Volume Measurement Accuracy | < 0.1 mL |
| Distillation Rate | 4–5 mL/min |
| Heating Power | Up to 1200 W (programmable ramp control) |
| Refrigeration | Imported German compressor |
| Temperature Sensor | Pt100 glass probe (IEC 60751 Class A) |
| Liquid Level Detection | Infrared photoelectric system |
| Display | 12.1″ embedded color touch screen |
| Data Storage | 100 test records |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 1500 W |
| Operating Ambient | 10–40 °C |
| Storage Ambient | 0–50 °C |
| Atmospheric Pressure Compensation | Integrated barometric sensor with real-time correction |
| Safety Features | Flame detector with automatic fire suppression |
| Compliance Standards | GB/T 7534, GB/T 615, GB 338–2011, GB/T 6536 |
| Brand | Miura |
|---|---|
| Origin | Japan |
| Model | GO-2EHT |
| Certification | EN 61010-1, UL 61010-1:2012, CAN/CSA C22.2 No. 61010-1-12:2012, EN 55011:2009+A1:2010, EN 61000-6-2:2005, RoHS Directive 2011/65/EU, IEC 62321, BS EN IEC 63000:2018 |
| Solvent Consumption per Sample | <100 mL (90 mL n-hexane + 5 mL toluene) |
| Final Fraction Volume | 1–2 mL |
| Brand | Miura |
|---|---|
| Origin | Japan |
| Model | GO-4EHT |
| Certification | EN 61010-1, UL 61010-1:2012, CAN/CSA C22.2 No. 61010-1-12:2012, EN 55011:2009+A1:2010, EN 61000-6-2:2005, RoHS Directive (EU) 2015/863, IEC 62321, BS EN IEC 63000:2018 |
| Purification Principle | Thermally Enhanced Solid-Phase Extraction (SPE) with Chemically Modified Silica |
| Solvent Consumption per Sample | ≤90 mL n-Hexane + 5 mL Toluene |
| Final Fraction Volume | 1–2 mL |
| Flow Path Architecture | Valve-Free, Disposable Cartridge-Based |
| Channel Configuration | Independent or Simultaneous Operation of 4 Channels |
| Method Flexibility | User-Defined Method Editing Supported |
| Compliance Context | Designed for GLP-compliant dioxin analysis workflows aligned with EPA Method 1613B, EN 1948, and ISO 18073 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MJ-150-II / MJ-250-II / MJ-300-II |
| Price | USD 1,780 (approx., FOB Shanghai) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 1810C |
| Price | Upon Request |
| Input Water | Municipal tap water (high hardness), 1.0–5.0 kg/cm² pressure, 5–40 °C |
| Power Supply | 220 V / 50 Hz, 80 W |
| Ambient Operating Conditions | 5–40 °C, 10–80% RH |
| Production Rate | 10 L/h |
| Continuous Dispense Flow | 1.5 L/min |
| Type III Water Conductivity | <10 µS/cm (meets GB/T 6682–1992 Grade III & ASTM CAP/NCCLS standards) |
| Type I Water Resistivity | 18.25 MΩ·cm @ 25 °C (meets GB/T 6682–1992 Grade I & ASTM CAP/NCCLS standards) |
| TOC | <10 ppb |
| Silica Rejection | >99.9% |
| UV Absorbance (254 nm, 1 cm path) | ≤0.001 |
| Soluble Silica (as SiO₂) | <0.01 ppm |
| Particles (>0.22 µm) | <1 /mL |
| Heavy Metals (total) | <0.01 ppm |
| Cationic Impurities (Fe, Cu, Al, Ni, Zn, Cr, Na, K) | <0.001–0.02 ppb |
| Anionic Impurities (Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻) | <0.01–0.02 ppb |
| Display | 4-line color LCD |
| Housing | Matte black ABS |
| Control | Touch keypad with self-diagnostic boot sequence |
| Integrated Functions | Auto-flush timer, RO antiscalant algorithm, manual RO flush, low-water alarm, power-fail safeguard, full-tank standby mode, real-time resistivity monitoring, manual recirculation, scheduled ultrapure water recirculation |
| Purification Pathway | Tap water → Pre-filter → Water softener → Coarse filter → Fine filter → Activated carbon filter → Booster pump → RO membrane → Pure water tank → Membrane pump → Ultra-purification cartridge → Final 0.22 µm terminal filter → Type I outlet / Type III outlet |
| Accessories | 30 L polyethylene pure water storage tank |
| Documentation | User manual, installation guide, maintenance manual, warranty card |
| Service | On-site commissioning, system validation, and operator training included |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Molelement 1810v |
| Pricing | Available Upon Request |
| Feed Water | Distilled or RO Water (5–40 °C) |
| Continuous Flow Rate | 1.5 L/min |
| Production Rate | 10 L/h |
| Resistivity | 18.25 MΩ·cm @ 25 °C |
| TOC | <10 ppb |
| Silica Rejection | >99.9% |
| UV Absorbance (254 nm, 1 cm) | ≤0.001 |
| Particles (>0.22 µm) | <1 /mL |
| Heavy Metals | <0.01 ppm (max) |
| Cation Limits (ppb) | Fe <2, Cu <2, Al <3, Ni <1, Zn <5, Cr <1, Na <20, K <20 |
| Anion Limits (ppb) | Cl⁻ <10, NO₂⁻ <20, NO₃⁻ <20, SO₄²⁻ <10 |
| Compliant With | GB/T 6682–1992 Grade I, ASTM D1193–2020 Type I, NCCLS/CLSI EP21-A |
| Brand | Muira/MIURA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GO-6EHT |
| Pricing | Upon Request |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MVR Evaporator Technology |
| Pricing | Upon Request |
| Sample Processing | Industrial Wastewater Treatment |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N4R-1.0-50 |
| Price Range | USD 4,200–7,000 (FOB) |
| Water Flow Rate | 100–1000 L/h |
| Controllable Resistivity Range | 0.15–1.7 MΩ·cm |
| Control Accuracy | ±0.03 MΩ·cm |
| Max. Inlet Water Pressure | 0.5 MPa |
| Pressure Drop | 0.06 MPa at 3000 L/h |
| Connection Ports | 3/4″ female screw |
| Power Supply | AC 100–130 V / 220–240 V, 50/60 Hz, single-phase, 1 A |
| Enclosure Type | Rack or Cabinet |
| H₂O₂-Compatible Sterilization | Yes (3% hydrogen peroxide) |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Membrane Pilot Testing System |
| Pricing | Upon Request |
| Sample Processing | Wastewater Treatment |
| Membrane Types Supported | Ceramic & Organic (Polymeric) Membranes |
| Configurable MWCO Range | 1 kDa – 500 kDa |
| Operating Pressure Range | Up to 10 bar |
| Feed Capacity | 5–100 L per batch |
| System Architecture | Skid-mounted, Modular, Benchtop-to-Pilot Scale |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NF-Series |
| Pricing | Available Upon Request |
| Sample Processing | Industrial Wastewater & Process Streams |
| Molecular Weight Cut-Off (MWCO) | 100–1000 Da |
| Membrane Charge | Surface-Charged (Donnan Exclusion Dominant) |
| Divalent Ion Rejection | >90% (e.g., SO₄²⁻, Ca²⁺, Mg²⁺) |
| Monovalent Ion Rejection | 10–40% (e.g., Na⁺, Cl⁻) |
| Operating Temperature Range | 5–45 °C |
| Max Inlet Pressure | 25 bar |
| Feed pH Range | 3–11 |
| Membrane Material | Polyamide Thin-Film Composite (TFC) |
| System Configuration | Benchtop Skid-Mounted with Recirculation Loop, Pressure Control, and Permeate Monitoring |
| Brand | New Biolink |
|---|---|
| Model | UHP-RO Series |
| Max Operating Pressure | 20 MPa |
| Membrane Type | High-Pressure Tolerant RO Element with Open-Channel Feed Spacer |
| Feed Compatibility | High-Salinity Wastewater (TDS up to 120,000 mg/L) |
| Recovery Rate | ≥75% (system-dependent) |
| Origin | Beijing, China |
| Application | Laboratory-Scale Wastewater Concentration and Brine Minimization |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | DSV80 |
| Operating Pressure Range | 760 mbar to 1×10⁻³ mbar |
| Max. Heating Temperature | 250 °C |
| Feed Rate | 0.3–1 kg/h |
| Construction Material | High-purity quartz glass (Duran®-grade) |
| Vacuum Jacket | Ultra-high vacuum silvered insulation (10⁻⁶ mbar) |
| Visual Observation | Full-length vertical sight strip |
| Thermal Compensation | Expansion-compensating corrugated section |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OCM-6T |
| Pricing | Upon Request |
| Sampling Area | 100 cm² |
| Purge Gas Flow Rate | Up to 200 mL/min |
| Integrated Vacuum Pump | 1 unit |
| Dimensions (W×H×D) | 230 × 260 × 250 mm |
| Weight | 10 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ODS620 |
| Pricing | Available Upon Request |
| Brand | Ontech |
|---|---|
| Model | ONTECH 870 |
| Cooling Stages | Triple-stage liquid nitrogen cryogenic trapping |
| Compliance | HJ 759–2023, EPA TO-15, EPA TO-14A, HJ 1012–2018, GB/T 14678–1993, HJ 1078–2019, HJ/T 194–2005 |
| Sample Volume Range | 1–2000 mL (with mass flow controller integration) |
| Cold Trap Configuration | Three-tier cryofocusing system (dehydration trap, adsorption trap, focusing trap) |
| Software | Ontech EcoSuite v3.x with method library (TO-15, PAMS, HJ 759–2023), real-time graphical workflow monitoring, dual hardware/software temperature safety interlocks, GC-MS vendor-agnostic control interface |
| Connectivity | Ethernet-based LAN interoperability across Ontech analytical platform |
| Brand | Ontech |
|---|---|
| Model | Ontech810 |
| Application | Automated introduction of VOC samples from pressurized canisters and gas bags into pre-concentrators |
| Sample Capacity | 16-position (customizable) |
| Flow Path Treatment | Silonite®-coated, heated to ≥110 °C |
| Leak Detection | Integrated pre-valve automated leak check |
| Post-run Protocol | Software-controlled line purging and reverse flush |
| Compliance | Designed to support EPA Method TO-14A, TO-15A, and HJ 759–2023 |
| Physical Architecture | Vertical stack configuration |
| Compatibility | Universal interface for SUMMA®-type electropolished stainless-steel canisters (6L/1L/0.5L), Tedlar® gas sampling bags (including 1L–10L), and direct coupling to Ontech870 Pre-concentrator |
| Operating Temperature Range | Ambient to 110 °C (isothermal zone control) |
| Materials of Construction | Electropolished 316SS with Silonite® inert coating on all wetted surfaces |
| Brand | Ontech |
|---|---|
| Model | Ontech825 |
| Application | Ambient Air & Emission Source Sampling |
| Compliance | HJ 759–2023, EPA TO-14A, EPA TO-15 |
| Power Supply | Rechargeable Lithium Battery (≥12 h continuous operation) |
| Flow Control Range | 0.01–1.0 L/min (electronic mass flow controller, NIST-traceable calibration) |
| Pressure Monitoring | Digital vacuum/pressure gauge (0–30 psia, ±0.5% FS) |
| Leak Detection | Automated pre-sample vacuum decay test (detection limit ≤0.1 psi/min) |
| Surface Treatment | Silonite®-coated flow path (inertized fused silica) |
| Connectivity | Bluetooth 5.0 (mobile app), optional 4G LTE module |
| Enclosure Rating | IP65 (dust-tight, water-resistant) |
| Dimensions & Weight | 320 × 240 × 180 mm |
| Data Logging | Internal memory (≥10,000 sample records), timestamped flow/pressure/time metadata |
| Accessories | Carrying case, SUMMA canister adapter kit, particle filter (PTFE, 0.2 µm), calibration syringe, USB-C charging cable |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ontech820 |
| Pricing | Upon Request |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Model | Ontech821 |
| Sampling Medium | Ambient Air |
| Sample Container | Electropolished Stainless Steel SUMMA Canisters (2- or 4-position) |
| Flow Control | Integrated Mass Flow Controller (MFC), Digital Pressure Display |
| Sampling Modes | Timed, Triggered, Remote-Initiated, Sequence, Leak-Checked Pre-Sampling |
| Environmental Monitoring Options | Optional integrated meteorological sensor suite (temperature, humidity, pressure, wind speed/direction, noise), PM₁₀/PM₂.₅ (light scattering), PID VOC sensor, video module |
| Enclosure Rating | IP54 (dust- and splash-resistant) |
| Flow Range | 1–500 mL/min (adjustable via software, no hardware change required) |
| Flow Accuracy | ±2% of full scale |
| Pressure Measurement Range | 0–30 psia, resolution 0.01 psi |
| Data Logging | Internal SD card + cloud sync via embedded SIM (LTE Cat-1) |
| Software | Android mobile app + Windows-based desktop platform with audit trail, user access levels, and export to CSV/Excel |
| Compliance Support | Designed for EPA TO-14A, TO-15, ASTM D6196, and ISO 16017-1 workflows |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Ontech824 |
| Pricing | Available Upon Request |
| Brand | Ontech |
|---|---|
| Model | Ontech860-2 |
| Origin | Beijing, China |
| Cooling Method | Solid-state thermoelectric cooling (no liquid nitrogen required) |
| Compliance | HJ 759–2023, HJ 1078–2019, GB/T 14678–1993 |
| Sample Inlets | Summa canister, Tedlar bag, standard calibration gas cylinder |
| Target Analytes | C1–C12 VOCs and SVOCs including polar (aldehydes, alcohols, esters, ketones, ethers), non-polar, sulfur- and nitrogen-containing compounds |
| Water Removal | Selective cryogenic removal with aqueous-phase polar compound retention |
| Cold Trap Stages | Two-stage — primary dehumidification/decontamination trap + secondary composite focusing trap |
| Thermal Management | Fully heated, inertized sample path (up to 200 °C), zero cold spots |
| Software | Windows 7/10/11 compatible, method-driven automation, built-in leak detection (positive/negative pressure), audit-trail-capable QA/QC reporting |