| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TREF |
| Sample Capacity | 5 positions |
| Analysis Time per Sample | ~6 hours (standard conditions) |
| Detection | IR4 Infrared Detector (standard), optional Multi-Angle Light Scattering (MALS) and Capillary Viscometer |
| Minimum Operating Temperature | –20 °C |
| Software-Controlled Automation | Full remote operation and diagnostic capability |
| Solvent Handling | Closed-loop, minimal solvent consumption, no manual solvent contact required |
| Upgrade Path | Compatible with CRYSTAF-TREF hyphenated configuration |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mooney-Line |
| Pricing | Upon Request |
| Standard Compliance | ISO 289 |
| Power Supply | Single-phase AC 220 V, 50 Hz |
| Compressed Air Requirement | 4.2 kg/cm² (60 psi) |
| Rotor Speed | 2 rpm |
| Temperature Control | Digital PID |
| Temperature Range | Ambient to 200 °C |
| Measuring Units | Mooney units (MU) for viscosity |
| Test Modes | Mooney viscosity [ML(1+X)], scorch time (ts1, ts2), compound scorch & viscosity profiling, stress relaxation, die release test |
| Preheat Option | Enabled / Disabled per test protocol |
| Data Storage | Microsoft Access or SQL Server database (exportable) |
| Host PC Requirements | Pentium-class CPU, Ethernet interface, Windows 2000 or XP |
| Optional Accessories | Small rotor, large rotor, volumetric sample cutter |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Model | Rheo-Line MFR |
| Compliance | ASTM D5289, ASTM D6204, ASTM D6601 |
| Cavity Type | Dual-cone, fully sealed |
| Cavity Gap | 0.45 mm (nominal) |
| Torque Measurement | Top platen-mounted torque transducer |
| Closure System | Flexible closure mechanism to prevent film rupture and sample distortion |
| Temperature Control | 3-zone PID, ±0.03 °C accuracy |
| Drive System | High-performance servo motor with aerospace-grade digital servo controller |
| Frequency Range | 0.01–40 Hz |
| Strain Amplitude Range | 1%–200% |
| Torque Calibration | Precision torque spring |
| Power Supply | 220 V AC, 50 Hz, single-phase |
| Pneumatic Requirement | 4.2 kg/cm² (60 psi) |
| Torque Units | in·lb or N·m (user-selectable) |
| Temperature Units | °C / °F |
| Pressure Units | psi / kg/cm² (configurable) |
| Time Format | min/sec, min/decimal, sec |
| Data Export | Universal ASCII/CSV format compatible with SQL, LabVIEW, MATLAB, and LIMS platforms |
| Host PC Requirements | Pentium-class processor, Ethernet interface |
| Optional Accessories | Automated sample loader, volumetric sample cutter |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rheoline MDR |
| Price | Upon Request |
| Standard Compliance | ISO 6502, ASTM D5289 |
| Oscillation Frequency | 1.67 Hz |
| Oscillation Amplitude Options | 0.5° (standard), 1.0° or 3.0° (optional) |
| Temperature Range | 35–250 °C |
| Temperature Control | Digital PID |
| Torque Units | in·lb, dN·m |
| Temperature Units | °C, °F |
| Pressure Units (optional) | psi, kg/cm² |
| Time Format | min/sec, min/decimal, sec |
| Output Parameters | Elastic Modulus (G′), Viscous Modulus (G″), Tan δ, Curing Rate, Cavity Pressure (optional) |
| Data Storage | Microsoft Access or SQL database |
| Optional Accessories | Programmable multi-zone heating, Eccentric oscillating die, Cavity pressure transducer, Automated sample loader, Volumetric sample cutter |
| Software | Windows-based proprietary test platform with SPC module (optional), GLP/GMP-compliant audit trail support |
| Key Parameters | Brand: Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Model | XR-14-2 |
| Speed Range | 2000–20,000 rpm |
| Nominal Test Speed | 14,000 ± 200 rpm |
| Speed Accuracy | ≤0.1% |
| Resolution | 1 rpm |
| Display | LED |
| Power Supply | 220 VAC, 50 Hz, 2000 VA |
| Dimensions (W×D×H) | 400 × 350 × 740 mm |
| Net Weight | ~30 kg |
| Operating Environment | 10–40 °C, <85% RH |
| Continuous Operation | ≥60 min |
| Stirring Disk (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | Height 130 ± 2 mm, ID 58 ± 2 mm |
| Compliance | ISO 35 |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSY-8146H |
| Temperature Range | Ambient to 162 °C |
| Temperature Resolution | 0.1 °C |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJRZ-45 |
| Quotation | Available upon Request |
| Temperature Range | 0–300 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ±0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ±0.005 mm and Φ1.180 mm ±0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Brand | Qinji |
|---|---|
| Model | QJRZ-45 |
| Origin | Shanghai, China |
| Temperature Range | 50–450 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ± 0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ± 0.005 mm and Φ1.180 mm ± 0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Compliance | GB/T 3682, ISO 1133 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | QJRZ45 |
| Price Range | USD 1,050 – 2,100 |
| Test Method | Gravimetric (Mass Flow Rate) |
| Type | Standard-Configuration Melt Flow Indexer |
| Temperature Range | 100–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Barrel Diameter | Φ9.55 mm ±0.025 mm |
| Die Orifice Diameters | Φ2.095 mm ±0.005 mm and Φ1.180 mm ±0.010 mm |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 250 mm × 400 mm × 500 mm |
| Net Weight | 35 kg |
| Compliance | GB/T 3682–2000 & ISO 1133:2005 |
| (Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QJCXS-43 |
| Price | USD 9,100 |
| Test Temperature Range | −70 °C to 0 °C |
| Impact Velocity | 2.0 m/s ±0.2 m/s |
| Temperature Stability During Test (3 min) | ±0.5 °C |
| Impact Pin to Clamp Lower Edge Distance | 11.0 mm ±0.5 mm |
| Dimensions (W×D×H) | 700 mm × 700 mm × 1300 mm |
| Power Consumption | 1100 W) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | OXISTAR I / OXISTAR II |
| Maximum Working Pressure | 21 bar |
| Oxygen Pre-Pressure Range | 25 ±1 bar |
| Compressed Air Pre-Pressure | ≥7 ±0.5 bar |
| Burst Pressure Rating | 35 bar |
| Max Operating Temperature | 150 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temperature Uniformity | ±1 °C at 70 °C, ±2 °C at 150 °C |
| Pressure Sensor Range | 0–25 bar (±0.5% FS) |
| Rupture Disc Activation Pressure | 32 ±7.5% bar |
| Chamber Volume | 4 L per chamber |
| Heating Power per Chamber | 330 VA |
| Dimensions (W×D×H) | 87 × 66 (45) × 42 cm |
| Weight | 58 kg (OXISTAR II), 42 kg (OXISTAR I) |
| Power Supply | 230 V ±10%, 720 VA (OXISTAR II), 360 VA (OXISTAR I) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | PVC |
| Pricing | Upon Request |
| Heating Block | Electric |
| Sample Capacity | 32 wells (Ø5.2 mm × 60 mm depth) |
| Temperature Sensor | PT100 probe |
| Safety Feature | Overtemperature protection |
| Controller | Independent PID temperature programmer |
| Display | Dual digital readout (setpoint & actual temperature) |
| Temperature Accuracy | ±0.2 °C |
| Adjustable Range | 60–210 °C |
| Sample Tubes | 100 pcs/set (Ø5 mm × 110 mm) |
| Power Supply | 230 V / 50 Hz, 500 W |
| Optional Accessory | Automated colorimetric detection system compliant with EN 60811-3-2 for objective thermal stability endpoint determination |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | MFR200 |
| Load Cell Resolution | 0.1 g |
| Temperature Range | Ambient to 450 °C (±0.2 °C stability) |
| Standard Orifice | 2.095 mm diameter × 8.00 mm length |
| Piston Travel | 30 mm |
| Cut-Off Timing Accuracy | ±0.1 s |
| Weight Loading Options | Manual or Pneumatic (up to 11 bar, equivalent to ~21.6 kg force) |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682 |
| Brand | Ray-Ran |
|---|---|
| Origin | Netherlands |
| Model | MFR300 |
| Temperature Range | 0–450 °C (500 °C optional) |
| Temperature Accuracy | ±0.10 °C |
| Temperature Resolution | 0.10 °C |
| Piston Displacement Resolution | ±0.02 mm |
| Heating Zones | Dual-zone |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz, 10 A fuse |
| Connectivity | Wi-Fi, USB, Ethernet |
| Compliance | ISO 1133, ASTM D1238, GB/T 3682 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWK-300 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 50 °C/h and 120 °C/h |
| Deformation Measurement Range | −1.000 mm to +10.000 mm |
| Vicat Needle Tip Area | 1.00 ± 0.015 mm² |
| Sample Holder Thermal Expansion Coefficient | < 0.005 mm/100 °C |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 306, ISO 75, ISO 2507, ASTM D 1525, ASTM D 648 |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA elite |
| Drive Type | Direct-drive motor with high-resolution strain control |
| Torque Sensor | Patented high-stiffness, wide-range sensor with low noise floor |
| Frame Stiffness | Ultra-rigid monolithic frame eliminating instrument compliance |
| Temperature Control | Integrated gas-cooling unit for rapid and stable thermal regulation |
| Pressure Control | Pneumatically actuated, user-adjustable die closure pressure |
| Automation | Optional robotic autosampler for unattended operation |
| Calibration | User-performed torque and geometry calibration |
| Compliance | Designed to support ASTM D6204, ISO 6673, and ISO 10985 test methods |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | RPA Flex |
| Drive Type | High-Resolution Direct-Drive Motor |
| Torque Sensor | Patented High-Stiffness, Wide-Range Transducer |
| Frame | Ultra-Rigid Monolithic Structure |
| Control | Fully Programmable Strain, Frequency, Temperature, Time, and Mold Closure Pressure |
| Automation | Integrated Robotic Sample Handler |
| Mold Closure | Pneumatically Actuated, Adjustable Pressure Disc |
| Calibration | User-Executable with Replaceable Die Plates |
| Upgrade Path | Field-Upgradeable to Extended Frequency and Strain Range |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RSY-R2 |
| Pricing | Upon Request |
| Brand | Shanda |
|---|---|
| Model | SD-FSX |
| Origin | Shandong, China |
| Category | Rubber & Plastic Industry–Specific Instrument |
| Compliance | GB/T 6030–2006 |
| Imaging Sensor | 5 MP CMOS |
| Resolution Options | 640×480, 1024×768, 1280×1024, 2592×1944 |
| Interface | USB 2.0 |
| Calibration | Integrated micrometer scale with pixel-to-µm mapping |
| Output Formats | PDF, PNG/JPEG, Excel (.xlsx) |
| Software Compatibility | Windows XP/7/10 (32/64-bit) |
| Image Segmentation Modes | Automated thresholding + manual ROI selection |
| Standard Reference Libraries | ISO-aligned carbon black dispersion image library + user-customizable library |
| Data Export | Particle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030) |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | LB-100 |
| Application Scope | Polymer Processing Simulation (Compounding, Extrusion, Molding) |
| Core Function | Real-time Torque, Temperature & Pressure Monitoring During Dynamic Shear Processing |
| Measurement Principle | Couette-type Rotational Rheometry with Intensified Shear History Simulation |
| Compliance Context | Designed for ASTM D3835, ISO 11443, ISO 25577, and GLP-aligned R&D workflows |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | RL-11B1 |
| Temperature Control Range | 100–400 °C |
| Temperature Display Accuracy | < 0.2 °C |
| 8-Hour Temperature Stability | < 0.1 °C |
| Temperature Recovery Time | ≤ 4 min |
| Timing Range | 0–999.9 s & 0–9999 s |
| Standard Die Dimensions | Φ2.095 ± 0.005 mm & Φ1.180 ± 0.010 mm |
| Load Options | 325 g, 2160 g, 5000 g (standard configuration) |
| MFR/MVR Measurement Range | 0.01–9999 g/10 min (automated mode) |
| Compliance | GB/T 3682–2000, ISO 1133:1997(E), JIS K7210 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SMV-300/300RT |
| Mooney Viscosity Range | 0–200 M (extendable to 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotor Speed (SMV-300RT only) | 0.5–5 rpm |
| Rotor Type | L-shaped |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Heating Method | Thin-film heater with optimized PID control |
| Compression Method | Pneumatic cylinder actuation |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points programmable) |
| Scorch Point Setting Range | 0–99.9 M (up to 10 points programmable) |
| Data Logging & Statistical Analysis | Built-in |
| Brand | Eurotech |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D25–D35 |
| Price Range | USD 14,000 – 42,000 (FOB Italy) |
| Brand | EUROTECH |
|---|---|
| Origin | Italy |
| Model | XTR Series (with Vacuum Pump & Air-Cooled Strand Pelletizer) |
| Screw Diameter Options | 20 / 25 / 30 / 35 mm |
| Gearbox Design | Rear-Removable for Rapid Screw Extraction |
| Barrel | Bimetallic Construction |
| Screw | Special Surface-Coated Hardened Steel |
| Venting Configuration | Atmospheric or Vacuum-Connected (XTR-D Variant) |
| Application Focus | Polymer Processing, Recycled Material Compounding, Mineral-Filled Compound Extrusion |
| Brand | SRD |
|---|---|
| Model | RL-Z1B1 |
| Origin | Shanghai, China |
| Power Supply | 198–242 V AC, 50 Hz, 3 A |
| Temperature Control Range | 100–400 °C |
| Temperature Display Accuracy | < ±0.1 °C |
| 8-h Thermal Stability | < ±0.10 °C |
| Temperature Recovery Time | ≤ 4 min |
| Standard Die Orifice Diameters | Φ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm |
| Standard Load Masses | 325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g |
| MFR/MVR Measurement Range | 0.01–9999 g/10 min (automated) |
| Sample Compatibility | Thermoplastics including PE, PP, PC, PA, PS, POM, ABS, PMMA, cellulose esters, fluoropolymers (e.g., F46) |
| Cutting Mode | Microprocessor-controlled automatic timer-based extrudate cutting |
| Data Output | Integrated thermal printer with MFR, MVR, melt density (ρ), test duration, and calibration metadata |
| Dimensions (W×D×H) | 520 × 380 × 730 mm |
| Net Weight | Main Unit 40 kg, Weight Set 22 kg |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682.1–2018, GB/T 3682.2–2018 |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRD RL-Z1B1 |
| Price | USD 5,750 (FOB Shanghai) |
| Temperature Control Range | 100–400 °C |
| Temperature Display Accuracy | < 0.1 °C |
| 8-h Thermal Stability | < 0.10 °C |
| Temperature Recovery Time | ≤ 4 min |
| Standard Load Masses | 325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g |
| Die Orifice Diameters | Φ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm |
| Power Supply | 198–242 V AC, 50 Hz, 3 A |
| Dimensions (W×D×H) | 520 × 380 × 730 mm |
| Net Weight | Main Unit 40 kg, Weight Set 22 kg |
| Measuring Range | 0.01–9999 g/10 min (auto mode) |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682.1–2018, GB/T 3682.2–2018 |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | RL-Z1B1- |
| Temperature Control Range | 100–400 °C |
| Temperature Display Accuracy | < 0.1 °C |
| 8-Hour Temperature Stability | < 0.10 °C |
| Temperature Recovery Time | ≤ 4 min |
| Standard Die Orifice Diameters | Φ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm |
| Available Test Loads | 325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g |
| MFR Measurement Range | 0.01–9999 g/10 min (automatic mode) |
| Power Supply | 198–242 V AC, 50 Hz, 3 A |
| Dimensions (W×D×H) | 520 × 380 × 730 mm |
| Net Weight | Main Unit 40 kg, Weight Set 22 kg |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682 |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | RL-Z1B1+ |
| Temperature Range | 100–400 °C |
| Temp. Accuracy | ±0.2 °C (125–300 °C) |
| Temp. Stability | ≤±0.1 °C (8-h drift ≤0.1 °C) |
| Barrel ID | 9.550 ±0.020 mm |
| Die ID | 2.095 ±0.005 mm |
| Load Accuracy | ±0.5% |
| Standard Loads | 325 g to 21,600 g |
| MFR Range | 0.02–2000 g/10 min |
| MVR Range | 0.03–50000 cm³/10 min |
| Timing Resolution | 0.001 s |
| Auto-Cut Interval | 0–999 s |
| Compliance | ISO 1133:1997(E), ASTM D1238-95, GB/T 3682-2000, JJG 878, JIS K 7210 |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | SWB-300A/B |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C across bath |
| Bath Volume | 25 L |
| Test Stations | 3 |
| Deformation Measurement | Dial Gauge (0.01 mm resolution) |
| HDT Indenter Radius | R = 3.0 ± 0.2 mm |
| HDT Span Length | 100 ± 0.5 mm |
| Load Rod Mass | 88.35 g |
| Vicat Needle Cross-Sectional Area | 1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm) |
| Thermal Expansion of Test Frame | ≤ 0.01 mm (with correction value provided if exceeded) |
| Heating Power | 4 kW |
| Power Supply | 220 VAC, 20 A |
| Dimensions (L×W×H) | 830 × 500 × 540 mm |
| Net Weight | SWB-300A — 58 kg |
| Optional Feature | Motorized Lift Mechanism (SWB-300B only) |
| Brand | SRD |
|---|---|
| Origin | Shanghai, China |
| Model | SWB-300C |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C across 3 sensing points |
| Bath Volume | 25 L |
| Test Stations | 3 |
| Displacement Resolution | 0.01 mm |
| Vicat Needle Cross-Section | 1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm) |
| HDT Probe Radius | R = 3.0 ± 0.2 mm |
| HDT Support Span | 100 ± 0.5 mm |
| Load Rod Mass | 88.35 g |
| Max. Thermal Expansion of Fixture | ≤0.01 mm (automatically compensated) |
| Heating Power | 4 kW |
| Power Supply | 220 VAC, 20 A |
| Dimensions (L×W×H) | 830 × 500 × 540 mm |
| Net Weight (C-type) | 58 kg (excl. heat transfer oil) |