Rubber & Plastic Industry Specialized Instruments
Filter
Showing 271–300 of 465 results
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | HDT/VICAT |
| Maximum Temperature | 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.2 °C |
| Temperature Stability (Oil Bath Fluctuation) | ±0.2 °C |
| Heating Rates | 50 °C/hr, 120 °C/hr, or Custom |
| Displacement Resolution | 0.001 mm |
| Displacement Accuracy | <0.01 mm |
| Sample Immersion Depth | ≥35 mm |
| Span Between Supports (HDT) | 100 mm (optional 64 mm) |
| Sample Length (HDT) | Up to 102 mm |
| Test Stations | 6 independent positions |
| Weight Load Range | 1–2048 g (binary HDT weights), plus 10 N and 50 N VICAT needles |
| Cooling System | Integrated stainless-steel water-jacketed oil bath with external 18 °C coolant |
| Safety Features | Nitrogen purge interface, physical barrier (mesh screen) between heating/stirring components and sample zone, dual stirrers and heater isolated from test chamber |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, GB/T 1634, GB/T 1633, DIN 53461 |
| Brand | NYX |
|---|---|
| Model | CCT |
| Origin | Tianjin, China |
| Manufacturer | NYX (OEM/ODM Capable) |
| Compliance | GB/T 38304–2019, EN 511:2006, ISO 5085-1:1977 |
| Test Principle | Two-Plate Heat Flow Method (Steady-State Thermal Resistance Measurement) |
| Sample Diameter | ≈85 mm |
| Test Duration | ≤2 hours per specimen |
| Repeatability | <5% RSD (typical <1% between replicate runs) |
| Data Output | XML-formatted log files compliant with ISO/IEC 17025 traceability requirements |
| System Components | Precision aluminum test plates (hot/cold), climate-controlled chamber (±0.2°C stability), calibrated heat flux sensor array, real-time DAQ module, proprietary thermal resistance analysis software |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB/T 18426 |
| Price Range | USD 420 – 535 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HY-760BX |
| Pricing | Upon Request |
| Control System | PLC-based Touchscreen Interface |
| Test Stations | 12 independent channels |
| Max. Sample Capacity | 12 specimens (standard configuration) |
| Specimen Type | Dumbbell-shaped or square cross-section rubber/plastic strips |
| Clamping Method | Four-sided mechanical clamping |
| Stroke Adjustment Range | 0–100 mm (continuously adjustable) |
| Test Speed | 60–300 rpm ±10 rpm |
| Drive Mechanism | Motor-driven eccentric cam + precision linkage system with linear guide columns |
| Failure Detection | Real-time individual channel break detection with autonomous counter halt |
| Safety Features | Interlocked transparent safety guard enclosure |
| Compliance Standards | GB/T 1688–2021, ISO 6943:1985, ASTM D430–18, DIN 53509-1:2006 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HY-8760 |
| Pricing | Available Upon Request |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | FSA-100 |
| Detection Resolution | down to 5 µm |
| Defect Classification Levels | 10 user-defined grades |
| Line Speed Independence | Yes (via roller-mounted encoder) |
| Imaging Sensor | High-speed line-scan camera |
| Light Source | Integrated uniform illumination module |
| Software Interface | Menu-driven, SAA-compliant GUI |
| Data Output | Real-time display, HDD storage, customizable PDF/printed reports (tabular & color bar chart formats) |
| User Access Control | Password-protected parameter profiles |
| Material Compatibility | Transparent (films, glass) and opaque (paper, aluminum foil, stainless steel, nonwovens) |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | ME-MFA |
| Drive System | Frequency-controlled servo motors for all drive rollers |
| Control Interface | Dual independent LCD touch-screen HMI (extruder + winder) |
| Tension Control | Two-zone closed-loop tension control system |
| Data Integration | LIMS-compatible digital output (OPC UA & Modbus TCP), remote operation enabled |
| Certification Context | Designed to support ASTM D2673, ISO 1133, ISO 14389, and internal QC protocols aligned with ICH Q5, USP <1043>, and GMP Annex 15 traceability requirements |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | OCS Online Analysis |
| Type | Integrated In-Process Polyolefin Resin Monitoring Platform |
| Compliance | Designed for ISO/IEC 17025-aligned QC environments, compatible with FDA 21 CFR Part 11–enabled DCS integration |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | OP5 |
| Compliance | ASTM D1238, ISO 1133 |
| Accuracy | ±0.5% |
| Calibration | Fully automated, zero manual calibration required |
| Sampling | Continuous micro-sampling (≈20 g per cycle) |
| Maintenance | Single-gear-pump architecture |
| Installation | Process-integrated, non-intrusive inline configuration |
| Application Domain | Polyolefins, polyethylene (PE), polypropylene (PP), thermoplastic elastomers (TPE), engineering plastics |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | PS-800C |
| Application Scope | Polyolefin resin pellets (transparent & semi-transparent) |
| Throughput | Up to 1,000 kg/h |
| Detection Principle | Dual 3-CCD color line-scan imaging under free-fall conditions |
| Output Functions | Contamination identification, particle rejection triggering, color-ratio quantification |
| Compliance Context | Designed for GLP-aligned QC environments |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | PS25C |
| Camera | 3-CMOS Color Imaging Sensor |
| Minimum Detectable Particle Size | ≥20 µm |
| System Dimensions (Main Unit) | 900 × 500 × 450 mm |
| Weight (Main Unit) | ~30 kg |
| Image Processing Unit Dimensions | 190 × 450 × 600 mm |
| Weight (IPU) | ~12 kg |
| Video Output | Composite (1 V p-p, 75 Ω) & RGB (0.7 V p-p, 75 Ω) |
| SNR | 58 dB |
| Line Frequency | 15.625 kHz |
| Power Consumption | 5.6 W |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | ST-4 |
| Configuration | Desktop-integrated line-scan imaging system with dual-mode (transmission/reflection) illumination |
| Detection Principle | High-speed linear CCD-based surface defect metrology |
| Sample Handling | Motorized precision translation stage with programmable scan speed and repeatable positioning |
| Software Platform | Windows-based GUI with real-time image acquisition, defect classification, and audit-trail-enabled data logging |
| Compliance Context | Designed for R&D lab environments supporting ISO 9001-aligned quality documentation workflows and GLP-compliant experimental traceability |
| Brand | OMICRON |
|---|---|
| Origin | Austria |
| Model | CMC 256plus |
| Input Voltage Range | 85–264 VAC, 45–65 Hz |
| Operating Temperature | 0–50 °C |
| Weight | 16.0 kg |
| Dimensions | 450 × 145 × 390 mm |
| Compliance | IEC 61000-4 (EMC), IEC 61010-1 (Safety), ISO 9001 |
| Output Accuracy Class | Up to 0.2 |
| Synchronization | GPS / IRIG-B (<1 µs typical timing error) |
| Communication Protocols | IEC 61850 (GOOSE, SV, MMS), IEEE C37.118-1/2 |
| Software Platform | OMICRON Control, Test Universe |
| Brand | EUROTECH |
|---|---|
| Origin | Germany |
| Model | Pelletizing-20D |
| Screw Diameter | 20 mm |
| L/D Ratio | 25:1 |
| Max. Screw Speed | 150 rpm |
| Heating Zones | 4 (independent microprocessor-controlled) |
| Temperature Range | Ambient to 350 °C per zone |
| Strand Cooling | Water bath + forced-air cooling |
| Die Options | 3 mm and 4 mm round orifices |
| Feed Hopper | Equipped with material-level sensor and empty-feed alarm |
| Torque Monitoring | Real-time display with overload shutdown |
| Control Interface | TFT touchscreen panel with dedicated soft-keys for each heating zone |
| Screw Configuration | Three-zone design with dedicated mixing section (mixing length ratio: 4:1) |
| Safety Features | High/low temperature alarm, torque limit lockout, emergency stop |
| Brand | Kage |
|---|---|
| Origin | Germany |
| Model | PETFlow |
| Standards Compliance | EN ISO 1133 (Methods A/B), ASTM D1238 (Methods A/B) |
| Measurement Modes | MFR (g/10 min), MVR (cm³/10 min), Intrinsic Viscosity (IV, dL/g) |
| Temperature Range | Up to 400 °C |
| Software | K-BASE (Windows-based, GLP-compliant control and calculation platform) |
| Sample Types | PET flakes and pellets |
| Regulatory Context | Supports audit-ready data management per FDA 21 CFR Part 11 requirements (electronic signatures, user access control, change tracking) |
| Brand | PILOTECH |
|---|---|
| Model | YC-910 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic (China-Made) |
| Throughput | 1–3 kg/hr |
| Extruder Screw Speed | 50 rpm |
| Spheronizer Disc Speed | 1400 rpm |
| Pellet Diameter Range | 0.3–3 mm |
| Disc Diameter | 250 mm |
| Power Rating | 3 kW |
| Compressed Air Requirement | 0.3 m³/h |
| Integrated Cooling System | Built-in Chilled Water Circulation Unit |
| Functionality | Combined Extrusion, Spheronization & Optional Film Coating |
| Brand | Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | XR-14 |
| Price | USD 2,600 (FOB Beijing) |
| Stirring Speed | 14,000 rpm ± 200 rpm |
| Speed Range | 2,000–24,000 rpm (adjustable) |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤ 0.1% FS |
| Sample Container | Cylindrical borosilicate glass vessel (ID 58 mm, OD 63 mm, H > 100 mm) |
| Stirrer Discs | Two interchangeable discs — natural rubber latex disc (Ø 20.83 ± 0.03 mm, t 1.57 ± 0.05 mm) |
| Stirrer Shaft Tip Diameter | 6.3 mm |
| Operating Ambient | 10–40 °C, < 85% RH |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 × 350 × 720 mm |
| Cooling System | Integrated recirculating coolant pump |
| Display | LED digital readout via frequency converter interface |
| Compliance | GB/T 8301–2008, SH/T 1151–1998 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CEF |
| Type | Polyolefin Characterization Analyzer |
| Automation Level | Fully Automated |
| Analysis Time per Sample | ≤25 min |
| Sample Capacity | 42-position autosampler |
| Detection Options | IR4 or IR5 FTIR concentration detectors |
| Optional Detectors | Viscometer, Multi-Angle Light Scattering (MALS) |
| Temperature Range | –20 °C to 160 °C (with low-temp and high-temp accessories) |
| Compliance | Designed for GLP/GMP environments |
| Software | CEF Control & Analysis Suite (21 CFR Part 11 compliant audit trail optional) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF |
| Sample Capacity | 5 samples per run |
| Cycle Time | ~6 hours |
| Minimum Operating Temperature | −20 °C |
| Detection | IR4 Infrared Detector |
| Configuration | Benchtop, Fully Automated |
| Solvent Handling | Closed-loop, Minimal Consumption |
| Software Interface | Intuitive GUI with Remote Monitoring & Diagnostics |
| Upgrade Path | Compatible with CRYSTAF-TREF dual-technique configuration |
| Compliance | Designed to support GLP/GMP workflows and ASTM D7283 (Standard Test Method for Determination of Comonomer Content in Polyolefins by Crystallization Analysis) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CRYSTAF QC |
| Pricing | Available Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTAF-TREF |
| Technique | Dual-Mode (Crystallization Analysis Fractionation & Temperature Rising Elution Fractionation) |
| Sample Capacity | 5 samples per run |
| Analysis Time | ≤6 h/sample (TREF mode), ≤8 h for 5 samples (CRYSTAF mode) |
| Minimum Operating Temperature | −20 °C |
| Detector Options | IR4 Fourier-transform infrared detector, Differential Viscometer, Multi-Angle Light Scattering (MALS) |
| Automation Level | Fully automated solvent handling, fraction collection, and system cleaning |
| Software Compliance | Audit-trail enabled, user access control, 21 CFR Part 11–ready configuration available |
| Regulatory Alignment | Designed to support ASTM D7943, ISO 16152, and ISO 16014–4 workflows |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CRYSTEX |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | CRYSTEX QC |
| Sample Vessel Capacity | 240 mL |
| Maximum Sample Mass | 4 g |
| Analysis Time per Sample | 150 min |
| Detector Configuration | Dual-channel concentration detector + composition detector |
| Operational Mode | Unattended 7×24 h |
| Solvent Handling | Fully enclosed, operator-free solvent exposure |
| Compliance | Designed for ISO 16152, ASTM D5492, and internal QC/GLP workflows |
| Software | CRYSTEX Control & Evaluation Suite with audit trail and user access levels |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-QC |
| Operating Temperature Range | 140–160 °C |
| Analysis Time per Sample (incl. dissolution) | ≤30 min |
| Detection | IR5 Selective Infrared Detector (C–H stretch, 3.42 µm) |
| Concentration Sensitivity | 0.125 mg/mL (S/N ≥60) |
| Optional Detectors | Dual Capillary Viscometer (IV), IR4 |
| Column Configuration | Pre-packed High-Throughput GPC Columns (macroporous crosslinked polystyrene/divinylbenzene, calibrated for polyolefins) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data handling |
| Sample Throughput | Up to 24 samples unattended |
| Dimensions | Benchtop (W × D × H: 750 × 600 × 550 mm) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IVA |
| Dissolution Temperature Range | Up to 200 °C |
| Sample Capacity | 42 positions |
| Capillary System | Dual stainless-steel capillary viscometer |
| Optional Detector | IR4 infrared detector for C–H bond quantification |
| Solvent Handling | Fully automated solvent addition, dissolution, and system cleaning |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | C20 |
| Fractionation Capacity | 10–20 g per run |
| Operating Modes | TREF (Temperature Rising Elution Fractionation) and Molar Mass Fractionation |
| Cycle Time | ≤48 h including dissolution |
| Fraction Collection | Up to 9 fractions per run |
| Detection | Integrated IR detector for real-time fraction monitoring |
| Control | Remote operation and interactive diagnostics enabled |
| Compliance | Designed for GLP-compliant laboratories |
| Software | Fully automated method sequencing with audit trail capability |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PREP mc2 |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model Compatibility | GPC-IR5, IR4, TREF, CRYSTAF, and Related Polyolefin Analyzers |
| Lead Time | Up to 4 weeks (standard stock available for high-turnover items) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TGIC |
| Application Field | Polyolefin Characterization (Elastomers, Block Copolymers, Amorphous Fractions) |
| Operating Principle | Temperature-Programmed Adsorption/Desorption Chromatography in High-Temperature Solvent (e.g., 1,2,4-Trichlorobenzene) |
| Detection Options | IR4/IR5 FTIR Detectors, Viscometer, Multi-Angle Light Scattering (MALS), MCT-enhanced IR Sensitivity |
| Automation | Robotic Autosampler (42-position), Fully Integrated Solvent Delivery, Online Filtration, Remote Diagnostics |
| Software Platform | Cirrus GPC/SEC + TGIC Module (Compliant with 21 CFR Part 11 Audit Trail & User Access Control) |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Sample Throughput | Up to 42 samples unattended with method-independent sequencing |