Second-hand Analytical Instruments
Filter
Showing 331–360 of 605 results
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | PF6-2 |
| Price | USD 4,200 (FOB Beijing) |
| Instrument Category | Spectroscopy |
| Operational Age | Refurbished & Certified |
| Warranty | 6 Months Limited Hardware Warranty |
| Compliance | Meets GB/T 21189–2007 (Chinese National Standard for AFS), ASTM D5673–17 (for As/Se in Water) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UVIS 205 |
| Price Range | USD $1,400–7,200 (FOB) |
| Product Category | HPLC UV-Vis Detector |
| Operational Age | 4–5 years |
| Warranty | 6 months limited |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | AB5500 |
| Instrument Age | 10 years |
| Category | Used Liquid Chromatography–Tandem Mass Spectrometer (LC-MS/MS) |
| Compliance Context | Designed for GLP/GMP-regulated environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 2000 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | LC-MS/MS System |
| Ionization Sources | TurboIonSpray® (ESI) and Heated Nebulizer (APCI) |
| Flow Rate Range (ESI) | 2–1000 µL/min |
| Flow Rate Range (APCI) | 0.2–2.0 mL/min |
| Collision Cell Technology | LINAC™ Linear Accelerator |
| Detection Mode | Pulse-counting Electron Multiplier |
| Dynamic Range | 1–4 × 10⁶ cps |
| Vacuum System | Air-cooled Differential Turbomolecular Pumps |
| Operating Temperature | 15–30 °C |
| Power Supply | 208–240 V AC, Single-phase |
| Required Gases | High-purity Nitrogen, Zero-air (oil-free, clean compressed air) |
| Dimensions (H×D×L) | 60.5 × 50 × 105 cm |
| Service History | Refurbished & Fully Tested |
| Operational Age | ~4 years |
| Warranty | 6 months limited hardware warranty |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API 3000 |
| Instrument Type | Triple Quadrupole LC-MS/MS System |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Vacuum System | Dual-stage Turbo-V 551 Navigator molecular pump (Agilent) |
| Ionization Sources | TurboIonSpray® and APCI |
| Flow Rate Range (ESI) | 2–1000 µL/min |
| Flow Rate Range (APCI) | 0.2–2.0 mL/min |
| Detection | Pulse-counting detector with polarity switching |
| Dynamic Range | 1–4 × 10⁶ cps |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX (formerly Applied Biosystems) |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | API 4000 |
| Condition | Refurbished & Fully Tested |
| Compliance | Meets ASTM D7592, USP <1225>, ISO/IEC 17025 guidelines for method validation |
| Software | Analyst 1.6.2 or later (licensed) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | API 4000 |
| Application Domain | Pharmaceutical Development, Clinical Research, Environmental & Food Safety Analysis |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Compliance | FDA 21 CFR Part 11 (via Analyst® software), GLP/GMP-ready |
| Detection Modes | ESI and APCI |
| Maximum LC Flow Rate | 3 mL/min |
| Collision Cell Technology | LINAC® High-Pressure Collision Cell |
| Ion Source | Turbo V™ Dual-Gas Heated Electrospray and Atmospheric Pressure Chemical Ionization Source |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | API4000 |
| Instrument Type | Triple Quadrupole Liquid Chromatography-Tandem Mass Spectrometer |
| Application Domain | Quantitative Bioanalysis, DMPK, Clinical Research, Impurity & Metabolite Identification |
| Condition | Factory-Refurbished |
| Operational Age | 6–8 years |
| Warranty | 12 months comprehensive coverage |
| Regulatory Compliance Support | FDA 21 CFR Part 11–ready software configuration, GLP/GMP-aligned audit trail capability |
| Ionization Modes | TurboIonSpray®, APCI, optional DuoSpray™ and PhotoSpray™ sources |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | ExionLC AC |
| Product Category | Chromatography |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Included Components | AC Column Oven, AC Autosampler, AC Binary Pump, AC Controller, AC Degasser, Dedicated Workstation PC with Analyst Software, Tubing & Cables |
| Compliance | Fully Tested and Verified by SpectraLab Scientific |
| Condition | Refurbished, Operational, Ready for GLP/GMP-Compliant Deployment |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 2000 |
| Instrument Type | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Configuration | Standalone MS or LC-MS Compatible (with Shimadzu, Agilent HPLC systems) |
| Operational Age | 3–4 years (Total Service Life: ~7 years) |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Model | QTRAP 4000 |
| Application Domain | LC-MS/MS Quantitation & Structural Characterization |
| Operational Age | 3–4 years in active service |
| Total Service Life | ~7 years |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11–ready software environment (with optional audit trail configuration) |
| Sample Introduction | Compatible with multiple HPLC/UHPLC platforms (Agilent, Shimadzu, Waters, Thermo) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Configuration | QTRAP 4500 MS/MS + Shimadzu Nexera LC-30AD UHPLC |
| Mass Analyzer Type | Hybrid Triple Quadrupole / Linear Ion Trap |
| Ion Sources | ESI & APCI |
| Mass Range | 10–10,000 Da |
| Resolution (FWHM) | Up to 10,000 |
| Detection Limit | Low-fg/mL (on-column, typical for peptide standards) |
| Scan Speed | Up to 10,000 Da/s |
| Acquisition Modes | Full Scan, SIM, MRM, Enhanced MS (EMS), Enhanced Product Ion (EPI), Information-Dependent Acquisition (IDA) |
| Software | AB SCIEX Analyst v1.7.2 or later |
| Compliance | Supports 21 CFR Part 11 audit trails (when configured with validated IT infrastructure and user access controls) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 5500 |
| Mass Range | up to 1250 Da |
| Ion Source Options | Turbo V™, TurboIonSpray®, APCI, DuoSpray®, NanoSpray III®, LDTD, LESA Clarity®, Digital PicoView®, NanoSource®, SelexION® |
| Detector | AcQuRate™ Pulse Counting Detector |
| Scan Modes | Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss, MRM, EMS, EPI, ER, MS³, MRM³, TripleTrap™ |
| Warranty | 90-day comprehensive hardware and software functionality warranty |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad 3500 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Mass Range | 5–2000 Da |
| Ionization Sources | Turbo V™ ESI and APCI |
| Flow Rate Compatibility | 5 µL/min to 3 mL/min |
| Detector | AcQuRate™ Pulse-Counting Digital CEM |
| Collision Cell | Curved LINAC™ |
| Software | Analyst® 1.6.2 (with sMRM™), MultiQuant® |
| Operational Age | 3–4 years |
| Total Service Life | ~7 years |
| Warranty | 6 months post-delivery |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF 5600+ |
| Instrument Type | Quadrupole Time-of-Flight (QTOF) Mass Spectrometer |
| Configuration | Integrated with Shimadzu Prominence UFLC System |
| Age | 4–5 years |
| Warranty | 12 months |
| Compliance | FDA 21 CFR Part 11 ready |
| Software | SCIEX OS v2.4 or later (included) |
| Brand | SEDEX (by S.E. Industries) |
|---|---|
| Origin | France |
| Model | ELSD-LT / ELSD-LT II / ELSD-LT III (Sedex 75/85/100) |
| Light Source | LED (470 nm) |
| Detector | High-sensitivity photomultiplier tube with digital signal processing |
| Detection Limit | 100 pg (C12EO8, micro-HPLC) |
| Typical Quantitation Range | 0.5–5 µg |
| Evaporation Temperature Range | Ambient to 100 °C (1 °C resolution) |
| Flow Rate Compatibility | 100 µL/min – 5 mL/min |
| Nebulizer Options | 4 types (HPLC, CC, Micro, UPLC) |
| Carrier Gas Consumption | <3.0 L/min |
| Required Gas Supply | N₂ or clean dry air, ≥5 L/min at 2–4.5 bar |
| Baseline Noise | <1 mV/h (aqueous), <3 mV/h (non-aqueous, GAIN-dependent) |
| Signal Output | 0–1 V analog |
| Gain Setting | 1–12 (2048-point digital resolution) |
| Data Acquisition Rate | 100 Hz |
| Interface | RS-232 |
| Software Control | Optional full-parameter programming (Agilent-compatible drivers available) |
| GLP Compliance Features | Audit trail, user authentication, parameter locking |
| Dimensions | 250 × 480 × 550 mm |
| Weight | 18.5 kg |
| Power | 230 V / 50 Hz / 1.7 A |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV765 |
| Price | USD 350 (FOB Shanghai) |
| Product Category | Spectroscopy |
| Usage Duration | Refurbished Unit (1–3 years operational history) |
| Warranty | 6 months limited parts & labor |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AA-6300 |
| Wavelength Range | 185–900 nm |
| Monochromator | Aberration-Corrected Czerny-Turner |
| Slit Widths | 0.2, 0.7, 0.7L, 2.0L nm (4-position auto-switching) |
| Detector | Photomultiplier Tube (PMT, short-wavelength optimized) |
| Optical System | Flame mode — dual-beam optics |
| Background Correction | High-speed Self-Reversal (BGC-SR) |
| Lamp Holders | 6-position turret with simultaneous 2-lamp operation (1 preheat) |
| Lamp Modes | Emission, NON-BGC, BGC-SR, BGC-D₂ |
| Software Platform | Microsoft Windows 2000™ compatible acquisition and quantitation software |
| Warranty | 6 months limited parts and labor |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AA6800 |
| Instrument Type | Atomic Absorption Spectrophotometer |
| Spectral Technique | Flame and Graphite Furnace AAS |
| Usage Duration | 1–2 years |
| Warranty | 1 year |
| Category | Imported Analytical Instrument |
| Compliance | Meets ISO/IEC 17025-relevant operational requirements for trace metal analysis |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AOC-20i |
| Instrument Type | Gas Chromatography Autosampler |
| Compatible GC Models | GC-14A/B, GC-15A, GC-16A, GC-17A (Ver. 1/2/3), GC-1700, GC-18A, GC-2010, GC-2010Plus, GC-2014, GC-2025 |
| Power Configuration | Integrated (for GC-2010 series) or External (with optional mounting kit) |
| Sample Capacity | Up to 12 vials (single unit) |
| Operational Age | 6–8 years |
| Warranty | 12 months |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | CBM-20 Alite System Controller |
| Category | Networked HPLC System Controller |
| Condition | Refurbished |
| Warranty | Not Included |
| Compliance | Designed for Shimadzu LC-10/20/VP Series and Prominence Systems |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | CTO-10AVP |
| Type | HPLC Column Oven |
| Condition | Refurbished |
| Warranty | Not Applicable |
| Compliance | Designed for Shimadzu LC Systems (e.g., LC-10AT, SPD-10A, SCL-10A) |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTO-20A |
| Price Range | USD 1,400–7,000 (FOB) |
| Product Category | Chromatography Equipment |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CTO-20AC |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty Period | 6 months |
| Price Range | USD $1,200–$6,500 (FOB) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | EDX-720 |
| Analysis Elements | Na (11) to U (92) |
| Sample Capacity | Ø300 mm × 150 mm H |
| Detector | Si(Li), Energy Resolution: 145 eV |
| Detection Limits | Cd: 1.7 ppm, Pb: 2 ppm, Cr: 2 ppm, Br: 2 ppm, Hg: 2 ppm |
| X-ray Filters | 5-position automatic filter changer |
| Software | Qualitative & Quantitative analysis suite (FP method, standard curve, matrix correction, thin-film FP, background-FP) |
| Operational Age | 3–4 years |
| Total Service Life | 6–8 years |
| Warranty | 6 months |
| Compliance | RoHS, WEEE, ELV, ASTM F963, EN 71, Sony SS-00259 (STM-0083) |
| Brand | Shimadzu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FTIR-8300E |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Spectroscopy |
| Operational Age | 3–4 years |
| Warranty | 6 months limited parts and labor |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-14A/B |
| Instrument Type | Gas Chromatograph |
| Age | 5–7 years |
| Warranty | 6 months |
| Regulatory Status | Imported Instrument |
| Distribution Channel | Authorized Distributor |
| Category | Refurbished Analytical Instrument |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-17A |
| Instrument Type | Gas Chromatograph |
| Operating Age | ≥7 years |
| Warranty | 6 months |
| Temperature Range (Oven) | Up to 450 °C |
| Detector | FID (Flame Ionization Detector) |
| Injector | Split/Splitless |
| Automation | AOC-20i (6-position) + AOC-20s (100-position) Autosamplers |
| Control Software | GC-17A Chinese Reverse-Control Software |
| Flow Control | Advanced Flow Controller (AFC) & Advanced Pressure Controller (APC) |
| Data System | CLASS-GC10 or C-R7A(Plus) compatible |
| Compliance | ASTM D3606, ISO 10301, USP <621>, GLP-ready configuration |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010 Plus |
| Category | Gas Chromatograph |
| Instrument Age | 5–7 years |
| Warranty | 6 months |
| Temperature Range | Ambient +4°C to 450°C (down to –50°C with optional liquid CO₂ cooling) |
| Oven Cooling Rate | ~3.4 min (450°C → 50°C) |
| Max Programmed Ramp Rate | 250°C/min |
| Column Oven Volume | 13.7 L |
| Temperature Accuracy | ±1% of setpoint (calibratable to 0.01°C) |
| Temperature Uniformity | <2°C deviation across 200 mm diameter circle at 30 mm from chamber wall |
| Ambient Drift Compensation | <0.01°C/°C |
| Max Independent Inlet Units | 3 |
| Max Independent Detector Units | 4 |
| FID Detection Limit | 1.5 pgC/s (n-dodecane) |
| Dynamic Range (FID) | 10⁷ |
| Advanced Flow Control (AFC) | Pressure range 0–970 kPa |
| Dimensions (Oven) | 280 × 175 × 280 mm |
| Dimensions (Main Unit) | 515 × 530 × 440 mm |
| Weight (FID configuration) | 30 kg |
| Power | AC 230 V ±10%, 2600 VA, 50/60 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010 |
| Year of Manufacture | 2018 |
| Operational Age | 2–3 years |
| Warranty | 6 months |
| Category | Gas Chromatography System |
| Import Status | Imported Instrument |
| Distributor Type | Authorized Reseller |