Separation/Extraction Equipment
Filter
Showing 391–420 of 1377 results
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5425 |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 10 × 5.0 mL |
| Maximum Speed | 15,060 rpm |
| Maximum RCF | 21,330 × g |
| Dimensions | 24 × 39 × 24 cm |
| Acoustic Noise Level | < 51 dB(A) |
| Rotor Recognition | Yes (5.0 mL fixed-angle rotor, PCR swing-bucket rotor) |
| Acceleration/Deceleration Programs | 10-step selectable |
| Quick-Start Function | Short-spin mode with single-button activation |
| Lid Mechanism | Eppendorf QuickLock® fast-locking system |
| Lid Opening | Automatic post-run opening |
| Safety Certification | Third-party validated hermetic rotor sealing |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Refrigerated Centrifuge |
| Model | 5425 R |
| Speed Range | 100–15,060 rpm |
| Max RCF | 21,300 × g |
| Max Capacity | 10 × 5 mL |
| Temperature Range | −10 °C to 40 °C |
| Noise Level | <54 dB(A) |
| Timer Range | 10 s – 9 h 59 min |
| Dimensions (W × D × H) | 29 × 48 × 26 cm |
| Rotor Compatibility | Universal with Eppendorf 5425 series |
| Sterilization | Autoclavable rotors (CAMR-certified airtight lids) |
| Cooling System | High-efficiency compressor with ECO standby mode |
| Key Features | FastTemp pre-cooling (21 °C → 4 °C in 8 min), SOFT brake, At set rpm timing, Short spin button, rpm/rcf toggle, condensate tray |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 5427 R |
| Instrument Type | Benchtop Centrifuge |
| Feature Parameter | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Typical Configuration | Fixed-Angle Rotor Centrifuge |
| Maximum Capacity | 48 × 1.5/2.0 mL, 12 × 5 mL |
| Maximum Speed | 16,220 rpm |
| Maximum RCF | 25,001 × g |
| Dimensions | 31.9 × 54.0 × 25.4 cm |
| Noise Level | < 56 dB(A) |
| Acceleration/Deceleration Time | 18 s each |
| Timer Range | 5 s to 9 h 59 min, continuous operation enabled |
| Temperature Range | −11 °C to 40 °C |
| Refrigerant | R290 (propane) |
| Power Consumption | 495 W |
| Net Weight (without rotors) | 30 kg |
| Rotor Count | 9 |
| ECO Standby Options | 1, 2, 4, or 8 hours |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Centrifuge |
| Model | 5430 / 5430 R |
| Speed Range | 10,000–17,500 rpm |
| Max RCF | 30,130 × g |
| Max Capacity | 48 × 1.5/2.0 mL |
| Dimensions | 33 × 42 × 25 cm |
| Temperature Range (5430 R only) | –11 °C to 40 °C |
| Refrigeration | Patented compressor-based cooling system with FastTemp pro pre-cooling and continuous post-run cooling |
| Compliance | IEC 61010-1, ISO 13485 (for medical device manufacturing environments), GLP-compliant data logging capability |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5702 / 5702 R / 5702 RH |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (max. 4,400 rpm) |
| Functionality | Refrigerated Centrifuge (5702 R & 5702 RH) / Ambient-Temperature Centrifuge (5702) |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Target Applications | Cell and Bacterial Pellet Separation |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 4,400 rpm |
| Maximum RCF | 3,000 × g |
| Dimensions (W × D × H) | 32 × 40 × 24 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 5804/R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Class | Cellular & Bacterial Pelletization |
| Maximum Capacity | 4 × 250 mL or 2 × 5 Microtiter Plates (MTP) |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 20,913 × g |
| Dimensions (W × D × H) | 64 × 55 × 34 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5810/R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 14,000 rpm |
| Max RCF | 20,913 × g |
| Max Capacity | 4 × 750 mL or 4 × 4 MTP (Microtiter Plates) |
| Temperature Range (5810 R only) | –9 °C to 40 °C |
| Dimensions (W × D × H) | 70 × 61 × 35 cm |
| Rotor Recognition | Automatic |
| Imbalance Detection | Integrated |
| Noise Level | ≤ 59 dB(A) |
| QuickLock System | Yes |
| FastTemp Pre-cooling | Yes |
| ECO Standby Mode | Yes |
| Dynamic Compressor Control (DCC) | Yes |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | 5910 Ri |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Swinging-Bucket Centrifuge |
| Separation Level | Cellular & Bacterial |
| Maximum Capacity | 6 × 250 mL |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 22,132 × g |
| Dimensions | 72 × 66 × 37 cm |
| Noise Level | 53 dB(A) |
| Temperature Range | –11 °C to 40 °C |
| Acceleration/Deceleration | 10 adjustable profiles |
| Power Requirement | 1650 W |
| Voltage/Frequency | 230 V, 50–60 Hz |
| Rotor Compatibility | Fully compatible with all 5910 R rotors |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Benchtop Refrigerated Centrifuge |
| Model | 5920 R |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 22,132 × g |
| Maximum Capacity | 4 × 1000 mL |
| Temperature Range | −11 °C to 40 °C |
| Dimensions (W × D × H) | 740 × 710 × 400 mm |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Application Class | Biomolecular Separation |
| Compliance | IEC 61010-1, ISO 13485 (for medical device manufacturing), GLP/GMP-ready audit trail support via software |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Eppendorf |
| Product Type | Floor-standing centrifuge |
| Speed Class | Ultracentrifuge (>30,000 rpm) |
| Cooling | Refrigerated |
| Configuration | Horizontal rotor system |
| Separation Target | Large organelles / Viruses |
| Max Capacity | 8.0 L |
| Max Speed | 40,000 rpm |
| Max RCF | 118,000 × g |
| Dimensions (W×D×H) | 175 × 115 × 295 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | CP100NX / CP90NX / CP80NX |
| Instrument Type | Floor-standing Ultracentrifuge |
| Speed Class | >30,000 rpm |
| Function | Refrigerated Ultracentrifuge |
| Configuration | Fixed-angle Rotor System |
| Separation Target | Organelles, Viruses, Exosomes, Macromolecular Complexes |
| Max Capacity | 1,690 mL (P32ZT rotor) / 1,380 mL (P21A2 rotor) |
| Max Speed | 100,000 rpm (CP100NX), 90,000 rpm (CP90NX), 80,000 rpm (CP80NX) |
| Max RCF | 803,000 × g (CP100NX), 700,000 × g (CP90NX), 615,000 × g (CP80NX) |
| Dimensions | 790 × 690 × 880 mm |
| Noise Level | 51 dB(A) |
| Cooling System | CFC/HCFC/HFC-free Thermo-module |
| Temperature Control Accuracy | ±0.5 °C |
| Vacuum System | Rotary Oil Pump + Oil Diffusion Pump |
| Acceleration Modes | 10 |
| Deceleration Modes | 11 (including coast-down) |
| Brake System | Regenerative Braking with Energy Recovery |
| Display | 6.5" Color LCD Touchscreen |
| User Management | 3-Tier Access Control |
| Program Storage | Up to 1,000 Protocols |
| Interface | 2× USB (host/device), 1× LAN |
| Power Supply | AC 200–240 V, 50/60 Hz, ≤1,000 W |
| Weight | 390 kg |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Technologies (Himac) |
| Type | Floor-standing refrigerated centrifuge |
| Max Speed | 22,000 rpm |
| Max RCF | 58,700 × g |
| Max Capacity | 4 × 1,500 mL |
| Dimensions | 700 × 760 × 915 mm |
| Weight | 260 kg |
| Refrigerant | R410A |
| Noise Level | 64 dB(A) |
| Power Supply | 220–240 V, 50/60 Hz, 3200 W max |
| Interface | USB port for operation log export |
| Safety Features | Auto rotor recognition, non-contact imbalance detection, lid interlock, overspeed protection, rotor cover detection, overtemperature monitoring |
| Acceleration/Deceleration | 9 programmable modes each |
| Programmable Methods | 30 user-defined protocols with RCF and g·sec calculation |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Technologies Corporation (Himac) |
| Type | Floor-standing refrigerated ultracentrifuge |
| Speed Range | 300–30,000 rpm |
| Max RCF | 110,000 × g |
| Max Capacity | 6 × 1,000 mL or 4 × 1,500 mL |
| Noise Level | < 56 dBA |
| Dimensions (W×D×H) | 708 × 892 × 866 mm |
| Weight | 310 kg |
| Temperature Control Accuracy | ±2 °C |
| Refrigerant | R410A |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W max |
| Interface | 1× USB, 1× LAN |
| Program Storage | 1,000 protocols |
| Timer Range | 1 s–9 min 59 s (1-s increment) or 1 min–99 h 59 min (1-min increment), with hold function |
| Acceleration Profiles | 11 modes |
| Deceleration Profiles | 10 modes (incl. 2 variable slope) |
| Safety Features | Interlocked door, overspeed detection, imbalance sensing, rotor lid detection, overtemperature protection |
| Sterilization Compatibility | Autoclavable rotors (121 °C, 20 min) for R30AT, R10A3, R5S4 |
| Drive System | Inverter-controlled induction motor |
| Cooling System | Variable-speed rotary compressor |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CS150NX / CS150FNX |
| Instrument Type | Floor-standing Ultracentrifuge |
| Feature Parameter | Ultrahigh-speed Centrifuge (>30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Typical Configuration | Fixed-angle Rotor Centrifuge |
| Separation Level | Organelles / Viruses |
| Maximum Capacity | 6 × 30 mL |
| Maximum Speed | 150,000 rpm |
| Maximum RCF | 1,050,000 × g |
| Dimensions (CS150FNX) | 440 × 520 × 910 mm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Benchtop Microcentrifuge |
| Model | MiniSpin / MiniSpin Plus |
| Centrifugation Range | High-Speed (up to 14,500 rpm) |
| Max Rotor Capacity | 12 × 1.5/2.0 mL tubes + 2 × PCR strips |
| Max Speed | 14,500 rpm |
| Max RCF | 14,100 × g |
| Acceleration/Deceleration Time | <13 s (0 ↔ max speed) |
| Dimensions (W × D × H) | 22.6 × 23.9 × 12.0 cm |
| Rotor Material | Anodized Aluminum |
| Cooling Mechanism | Passive Airflow Optimization (No Active Refrigeration) |
| Timer Range | 10 s – 99 min (MiniSpin Plus only) |
| Instant Spin Function | Dedicated “Short Spin” Button |
| Lid Operation | Soft-close mechanism with automatic lid opening post-run |
| Compliance | IEC 61010-1, EN 61326-1 (EMC), CE Marked for Laboratory Use |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | MCV-88, MCR-88 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–15,000 rpm |
| Refrigeration | Yes (MCR only) |
| Rotor Type | Fixed-Angle |
| Maximum Capacity | 44 × 1.5/2.0 mL |
| Max Speed | 15,000 rpm |
| Max RCF | 21,380 × g |
| Dimensions (MCV/MCR) | 280 × 389 × 304 mm / 280 × 563 × 294 mm |
| Weight (MCV/MCR) | 17 kg / 35 kg |
| Temperature Range (MCR) | −20 °C to +40 °C |
| Drive System | Brushless DC Motor |
| Safety Features | Motor-Driven Lid Lock, V-Balance Imbalance Detection, SmartDrive Rotor Recognition, Genuine-Protec Lid Mechanism |
| Certifications | IEC 61010-1, ISO 13485 (Medical Device QMS), CE, UL/CSA Listed |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TCV-1500 / TCR-1500 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–16,000 rpm |
| Max RCF | 24,321 × g (fixed-angle rotor), 4,500 × g (swing-out rotor) |
| Max Capacity | 6 × 250 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (TCV/TCR) | 438 × 532 × 374 mm / 715 × 528 × 373 mm |
| Weight (TCV/TCR) | 52 kg / 77 kg |
| Motor | Brushless Inverter Drive |
| Safety | Electromagnetic Lid Lock, V-Balance Imbalance Detection, Genuine-Protec Lid System, Emergency Manual Lid Release |
| Compliance | ISO 13485, IEC 61010-1, EN 61326-1 (EMC), RoHS, CE |
| Brand | Esco |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Esco Versati-TS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Temperature Control Accuracy | ±2 °C |
| Speed Control Precision | ±10 rpm |
| Vibration Amplitude | ≤0.01 mm |
| Noise Level | ≤60 dB(A) |
| Rotor Autoidentification Time | ~1 s |
| Data Logging Capacity | ≥100,000 entries |
| Sterilization Compatibility | 121 °C, 15–20 min autoclave cycle |
| Display | 7-inch LCD touchscreen with bilingual UI (English/Chinese) |
| Safety Certifications | IEC 61010-1, IEC 61010-2-020, ISO 13485 (manufacturer), compliant with GLP/GMP documentation requirements |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Extraction Principle | Microwave-Assisted Solvent-Free Microwave Extraction (SFME) |
| Capacity Options | 2 L, 5 L, 12 L (lab & pilot) |
| Typical Extraction Time | 5–8 min (first drop), ~40 min (complete yield) |
| Output Compatibility | Direct GC-MS injection without solvent removal |
| Compliance | Designed for GLP-compliant workflows |
| Software Interface | Touchscreen GUI with method storage, real-time power/temperature monitoring, and exportable extraction logs (CSV, PDF) |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | ETHOS X |
| Application | Rapid total fat determination in food and feed samples |
| Sample throughput | 15 positions |
| Sample mass range | 3–15 g |
| Total process time | ≤ 3 hours |
| Temperature control | Full-vessel infrared temperature monitoring |
| Automation | Integrated balance interface for automatic mass data import and calculation |
| Extraction methodology | Microwave-assisted acid hydrolysis coupled with solvent extraction |
| Stirring | Built-in magnetic stirring system |
| Compliance context | Designed to support AOAC 991.36, ISO 1443, and USP <467> workflows |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200B |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 500 mL × 3 |
| Extraction Cycle Time | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Positions | 3 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 30 W |
| Net Weight | 15.7 kg |
| Operating Principle | Mechanical Stirring-Assisted Phase Separation |
| Brand | Euro Tech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET3200C |
| Instrument Type | Liquid-Liquid Extraction |
| Extraction Vessel Volume | 1000 mL × 3 |
| Extraction Time Range | 1–5 min per station |
| Dimensions (W×D×H) | 460 × 250 × 650 mm |
| Sample Throughput | 3 independent stations |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 20 W |
| Net Weight | 15.7 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE |
| Pricing | Available Upon Request |
| Vessel Capacities | 3 L, 5 L, 10 L, 30 L, 50 L, 100 L |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Design Pressure (Inner Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Temperature Control | Dual-point (Extraction & Jacket) |
| Safety Features | Low-level liquid protection, real-time temperature monitoring |
| Optional Ultrasound Module | Frequency range 15–60 kHz (focused transducer array, frame-type agitator integration) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Capacity | 3–100 L |
| Design Pressure (Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Stirring Power | 0.09–0.5 kW |
| Temperature Control | Integrated PID with Digital Display |
| Optional Ultrasonic Frequency Range | 15–60 kHz |
| Safety Features | Low-Level Liquid Protection, Dual-Temperature Monitoring, Expandable Multi-Unit Synchronization |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Capacity | 3–100 L |
| Design Pressure (Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Temperature Control Range | Ambient to 120 °C |
| Optional Ultrasonic Frequency | 15–60 kHz |
| Compliance | Designed for GLP-compliant R&D environments |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | EX-TE |
| Pricing | Available Upon Request |
| Vessel Capacities | 3–100 L (6 Models: EX-TE-03 to EX-TE-100) |
| Design Pressure (Inner Vessel) | 0.09 MPa |
| Jacket Design Pressure | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Temperature Control Range | Ambient to 120 °C |
| Optional Ultrasonic Frequency Range | 15–60 kHz (Pulsed or Continuous Mode) |
| Integrated Sensors | Real-time monitoring of extraction temperature, heating temperature, pH, vacuum level, agitation speed/type, and liquid level |
| Max. Speed | 4000 rpm |
|---|---|
| Max. RCF | 2220 ×g |
| Rotor Capacity | 8 × 15 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 380 × 480 × 330 mm |
| Weight | 25 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TGL-18C / TGL-18B |
| Price | USD 950 (FOB Shanghai) |
| Max Speed | 18,000 rpm |
| Max RCF | 22,000 ×g |
| Angle Rotor Capacity | 5 mL × 10 |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 250 VA |
| Dimensions (L×W×H) | 490 × 356 × 315 mm |
| Weight | 30 kg |
| Drive System | Frequency-Controlled Brushless Motor |
| Control Interface | Digital LED Display with Keypad |
| Rotor Types Supported | Fixed-angle rotors (e.g., 1.5 mL × 12, 5 mL × 10) |
| Safety Compliance | IEC 61010-2-020, EN 61326-1 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec 8000 |
| Extraction Chamber Volume | 65 mL |
| Receiver Flask Capacity | 40–110 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 or 12 samples per batch |
| Solvent Recovery Efficiency | up to 80% |
| Safety Features | Automatic solvent leak detection, auto-empty alert for recovery tank, self-diagnostic startup sequence |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Soxtec™ 255 |
| Extraction Chamber Volume | 30 mL |
| Receiver Flask Volume | 70–90 mL |
| Temperature Range | 0–285 °C |
| Temperature Control Accuracy | ±1% |
| Throughput | 6 samples per batch |
| Solvent Consumption per Sample | ~16 mL |
| Solvent Recovery Rate | up to 80% |
| Heating Time (20 °C → 280 °C) | 7–9 min |
| Typical Extraction Duration | 40–60 min |
| Repeatability | ±1% RSD |
| Sample Mass Range | 0.5–15 g |
| Sample Cup Dimensions | 33 × 80 mm (approx. 65 mL capacity) |
| Measurement Range | 0.1–100% fat content |