BrandAnton Paar Brabender
OriginGermany
ModelAquatrac-V
Measurement PrincipleCalcium Hydride Reaction (DIN EN ISO 15512:2019)
Resolution0.0001% H₂O
ApplicationResidual Moisture Analysis in Thermoplastics & MFR Sample Preparation
ComplianceFully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics
SoftwareAquatrac Control Software with LIMS/ERP integration capability
Data IntegrityAudit trail, user access levels, electronic signatures (21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSPECTRUMA
OriginGermany
ModelGDA 750 / GDA 550
Detection PrincipleGlow Discharge Optical Emission Spectroscopy (GD-OES)
Spectral Range190–800 nm (standard PMT system)
Spectral Resolution<20 pm FWHM (PMT)
Optical SystemPaschen-Runge mount, 750 mm focal length, holographically ruled grating (2400 lines/mm)
Max. Analytical Depth>200 µm
Depth Resolution≤1 nm
Elemental CoverageH, O, N, Cl, C, and all elements from Li to U
Detection LimitsSub-ppm (matrix-dependent)
Sputter Diameter1–8 mm (adjustable, same source)
DC SourceUp to 1500 V, 250 mA, fully programmable
RF SourceUp to 150 W, pulsed mode optional (GDA 750 only)
Sample Thickness Range50 µm – 45 mm
Vacuum SystemDual-stage rotary vane pump (<50 dB), oil-free pump for source chamber
Optional AccessoriesHigh-resolution CCD optical system, RF pulse generator, load-lock transfer chamber, 100-position autosampler, monochromator with triple-grating turret
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKunyuan Instruments
OriginTianjin, China
ModelSparkle
CoolingLiquid Nitrogen (Ambient Pressure)
Resolution Modes400 / 4000 / 10,000 (switchable in <1 s)
Detection LimitSub-ppb (typical), down to low-ppt (element-dependent)
Dynamic Range12 decades (Faraday cup + electron multiplier)
Sample ThroughputFull-element scan (78 elements) <5 min
Depth ResolutionSub-micrometer
Gas ConsumptionAr, ≥99.9995% purity
Dimensions2160 × 2040 × 1480 mm (L×W×H)
PowerAC 220 V / 50 Hz, grounding resistance <2 Ω
CoolingExternal chiller (500 W) for turbo pumps & magnet
Ambient18–24 °C, 40–60% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnton Paar
OriginAustria
ModelSAXSpace
Instrument TypeSmall-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS) System
q-Range0.03–49 nm⁻¹
Real-Space Resolution Range0.13–200 nm
Maximum 2θ74°
X-ray SourceSealed-tube (line or point focus)
Beam Size20 × 0.3 mm² (line), 0.3 × 0.3 mm² (point)
Operating Voltage40 kV
Operating Current50 mA
Minimum Sample Volume7 µL (liquid), few mg (solid)
Temperature Control Range−150 to 300 °C (±0.1 °C stability)
Measurement Time1–60 min
AutomationMotorized optical alignment, in situ heating/cooling, liquid handling compatibility