| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MTS120i |
| Temperature Range | −20 °C to +120 °C |
| Temperature Resolution & Accuracy | 0.1 °C |
| Control Method | Manual or USB 2.0–enabled software (MTDC600 controller) |
| Sample Area | 25 mm × 40 mm |
| Observation Port Diameter | 32 mm |
| Standard Chamber Height | 4 mm |
| Objective Working Distance Compatibility | 0.17 mm coverslip thickness |
| Sensor Type | RTD (Pt100) |
| Cooling Method | Solid-state thermoelectric (Peltier), no liquid nitrogen or chiller required |
| Optional Accessory | MC-5L auxiliary cooler for sub-zero stability |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MHCS622-V/G |
| Temperature Range | −190 °C to +600 °C |
| Temperature Resolution | 0.1 °C |
| Control Method | PID/PID-Switching |
| Sensor Type | RTD |
| Sample Area | 40 mm × 40 mm |
| Observation Aperture | 32 mm |
| Objective Working Distance | 6 mm (optional reduced WD) |
| Chamber Height | 4 mm standard, up to 20 mm |
| Electrical Feedthroughs | 4 channels (configurable) |
| Controller | MTDC600 Programmable Temperature Controller with USB 2.0 interface and embedded power supply |
| Cooling Option | LN2-SYS liquid nitrogen cryogenic system |
| Mounting | Horizontal or vertical integration compatible |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MHCS400–XR |
| Temperature Range | –190 °C to +400 °C (optional up to +600 °C) |
| Temperature Resolution | 0.1 °C |
| Control Method | PID/PID-Switching |
| Sensor Type | RTD (Pt100) |
| Sample Area | 40 mm × 40 mm |
| Chamber Height | 5 mm (customizable) |
| Observation Aperture | 32 mm (transmission light path: 1.5–7 mm, configurable) |
| Working Distance | 6 mm (reduced WD options available) |
| Controller | MTDC600 Programmable Temperature Controller |
| Optional Accessories | LN2-SYS Liquid Nitrogen Cooling System, Water-Cooled Mount, Gas Purge Enclosure, Probing XY Micropositioner (±12.5 mm travel, 0.1 µm resolution), Removable Lid, Thermal Shield Housing |
| Brand | MicrOptik |
|---|---|
| Origin | Poland |
| Model | MHS300 |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Control Method | Dual-Mode PID/PID-Switching |
| Sensor Type | RTD (Pt100) |
| Sample Area | 40 mm × 40 mm (customizable) |
| Mounting | Horizontal & Vertical Configurations Supported |
| Environmental Operation | Ambient Atmosphere |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MTS120CD |
| Temperature Range | −20 °C to +120 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability (with MTDC600 controller) | ±0.1 °C at 100 °C |
| Heating/Cooling Rate | Adjustable up to 30 °C/min |
| Control Algorithm | Dual-mode PID-PID switching |
| Sensor Type | RTD (Pt100) |
| Sample Cavity Dimensions | 80 × 55 × 9.5 mm |
| Reflected Light Aperture | 50 mm (customizable) |
| Transmitted Light Aperture | 5 mm (customizable) |
| Inert Gas Port | Optional |
| Mechanical Footprint | As per MTS120CD dimensional drawing |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MHCS400-VS |
| Temperature Range | −190 °C to 400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability at 100 °C | ±0.1 °C |
| Max Heating Rate | 100 °C/min |
| Max Cooling Rate | 60 °C/min |
| Minimum Heating Rate | 0.1 °C/min |
| Control Method | PID/PID-Switching |
| Sensor Type | RTD (Pt100) |
| Aperture | 5 mm (transmission), 30 mm (reflection) |
| Sample Area | 40 mm × 40 mm |
| Chamber Height | 8.5 mm |
| Vacuum/Gas Port Options | KF10, KF16, or 1/8″ Swagelok (customizable) |
| Overall Dimensions | 185 mm × 102 mm × 37 mm |
| Integrated XY Precision Stage | Protable, coaxial micrometer-driven |
| Controller | MTDC600 Programmable Temperature Controller (software- and manual-operable) |
| Optional Cryogenic Support | LN2-SYS Liquid Nitrogen Cooling System |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MHS1200-V/G |
| Max Temperature | 1200 °C |
| Temp Resolution | 1 °C |
| Control Method | PID/PID-Switching |
| Sensor | Type S Pt-10%Rh/Pt Thermocouple |
| Sample Area Options | Ø25 mm / 48 mm / 75 mm |
| Chamber Height | Standard 4 mm (customizable) |
| Observation Port Diameter | 32 mm (customizable) |
| Objective Working Distance | 6 mm (customizable) |
| Electrical Feedthroughs | 4 channels |
| Cooling | Integrated Water-Cooled Mounting Bracket |
| Controller | MTDC600 Programmable Temperature Controller (USB 2.0, ±0.4% of reading accuracy) |
| Brand | MicrOptik |
|---|---|
| Origin | Netherlands |
| Model | MTS120 |
| Temperature Range | −40 °C to +120 °C |
| Temperature Resolution | 0.1 °C |
| Control Method | PID/PID-Switching |
| Sensor Type | RTD (Pt100) |
| Sample Area | 25 mm × 40 mm |
| Chamber Height | 4 mm (standard, optional variants available) |
| Observation Aperture | 32 mm |
| Working Distance to Objective | 6 mm (optional reduced WD configurations) |
| Compatible Controller | MTDC600 Programmable Temperature Controller |
| Optional Auxiliary Cooling | MC-5L Recirculating Chiller |