Empowering Scientific Discovery

Shanghai Shouli Industry Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelPA-1000
Detection PrincipleScintillation Crystal (NaI(Tl))
Radiation TypeGamma (γ) Rays
Sensitivity≥1000 cpm at 1 µSv/h (Cs-137 reference)
Relative Error±10%
Energy Range>150 keV
Energy Response0.5–3.0 × (150 keV–1250 keV, relative to Cs-137 @ 662 keV)
Measurement Range0.001–9.999 µSv/h
Display4-digit LCD, µSv/h unit
Averaging Interval60-second moving average
Update Interval10 seconds
Dimensions68(W) × 28(D) × 121(H) mm
Mass≤175 g
PowerTwo AA alkaline batteries
Housing MaterialBio-based polymer (plant-derived plastic)
Audio AlertConfigurable on/off for dose rate change notification
ComplianceDesigned for educational and environmental screening use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-500
Measurement Unitsmg/kg, mg/g, mg/PC
Solvent Consumption per Extraction2 mL less than OCMA-300
Sample Volume per Test4 mL less than OCMA-300
Extraction VesselBacklit glass chamber
Data Storage Capacity>50 records
InterfaceRS-232, USB
Display3.5-inch backlit color LCD (320 × 240 resolution)
Power Input100 VAC / 60 VA or 240 VAC / 90 VA
Standard AccessoriesWater-separating filter (Ø40 mm, 5 pcs), PE transfer pipettes (2.5 mL, 5 pcs), 220 V power cord (1 pc), 10 mL heavy oil vial, 25 µL micro-syringe, OCMA-500 user manual
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModeliTrans
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOCMA-300/305
Measurement PrincipleNon-Dispersive Infrared (NDIR) Spectrophotometry
Detection Range0–200 mg/L (as oil)
Extractant SolventsOCMA-300 → S-316 (trichloroethylene substitute)
DisplayBacklit LCD with digital readout
InterfaceRS-232C port, printer interface
Data LoggingTimestamped measurement storage (date + time)
Repeatability±0.2 mg/L (0–9.9 mg/L), ±2.0 mg/L (10–99.9 mg/L), ±4.0 mg/L (100–200 mg/L)
Built-in Extraction ModuleYes
Self-Diagnostic FunctionYes
Compliance ContextDesigned for ASTM D7066, ISO 9377-2, and EPA Method 1664-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelHR-400
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0