Empowering Scientific Discovery

Shanghai Shouli Industry Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
Model719 SET Basic
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelHO-200
TypeIndustrial Online ORP Meter
ORP Range−2000 to +2000 mV
Temperature Range0 to 100 °C
ORP Resolution1 mV
Temperature Resolution0.1 °C
ORP Repeatability±5 mV
Temperature Repeatability±0.3 °C (equivalent input)
Linearity±5 mV (ORP), ±0.3 °C (temperature)
OutputTwo isolated 4–20 mA DC outputs (load ≤ 900 Ω)
Relay OutputsThree SPDT dry-contact relays (R1, R2, FAIL)
InputOne opto-isolated contact input for external cleaning command
CommunicationIsolated RS-485 (2-wire)
Power SupplyAC 100–240 V ±10%, 50/60 Hz
Power Consumption≤15 W
EnclosureAluminum, IP65-rated
Operating Ambient Temperature−20 to +55 °C
MountingWall or 50A pole mount
Weight~4.5 kg
ComplianceCE marking, FCC Rules, RoHS, WEEE
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model794 Standard
PriceUpon Request
pH Range0 to ±20.00
Potential Range0 to ±2000 mV
Current Range0 to ±200.0 µA
Temperature Range−150.0 to +450.0 °C
Burette Volumes1, 5, 10, 20, or 50 mL
Burette Resolution1/10000 of selected volume
Absolute Accuracy (10 mL burette)±0.02 mL
Relative Accuracy (10 mL burette)±0.2%
Input Impedance>10¹³ Ω
Polarization Current0 to ±127 µA
Polarization Potential0 to ±1270 mV (10 mV steps)
Electrode Inputs2 high-impedance measuring electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor
Method Storage Capacity100 methods
Dimensions (W×H×D)150 × 450 × 275 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model702 Economy
PriceUpon Request
pH Range0 to ±20.00
Potential Range0 to ±2000 mV
Current Range0 to ±200.0 µA
Temperature Range−150.0 to +450.0 °C
Burette Volumes1, 5, 10, 20, or 50 mL
Burette Resolution1/10,000 of selected volume
Absolute Burette Error±0.02 mL (with 10 mL burette)
Relative Accuracy±0.2% (with 10 mL burette)
Input Impedance>10¹³ Ω
Current Compensation<3.1 × 10⁻¹³ A
Thermal EMF Compensation Drift15 µV/K
Electrode Inputs2 high-impedance measuring electrodes, 1 reference electrode, 1 polarizable electrode, 1 temperature sensor
Polarization RangeCurrent 0 to ±127 µA
Differential AmplifierOptimized for low-conductivity non-aqueous titrations
Method Storage Capacity100 pre-programmed or user-defined methods
Dimensions (W × H × D)150 × 450 × 275 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
TypeImported Instrument
Model785 Universal
PricingUpon Request
Measurement RangepH 0 to ±20.00
Potential±2000 mV
Current±200.0 µA
Temperature−150.0 to +450.0 °C
Burette Volumes1, 5, 10, 20, or 50 mL
Resolution1/10,000 of burette volume
Absolute Accuracy±0.02 mL (with 10 mL burette)
Relative Accuracy±0.2% (with 10 mL burette)
Input Impedance>10¹³ Ω
Polarization Current±127 µA
Polarization Potential±1270 mV (10 mV steps)
Electrode Inputs2 high-impedance indicator electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Titration Volume Options1, 2, 5, 10, 20, or 50 mL
pH Range0 to ±20.00
Potential Range±2000 mV
Current Range±200.0 µA
Temperature Range−150.0 to +450.0 °C
Titration Resolution1/10,000 of burette volume
Absolute Accuracy (10 mL burette)±0.02 mL
Relative Accuracy (10 mL burette)±0.2%
Input Impedance>10¹³ Ω
Polarization Current±127 µA
Polarization Potential±1270 mV (10 mV steps)
Electrode Inputs2 high-impedance measuring, 1 reference, 1 polarization, 1 temperature sensor
Method Storage Capacity100 methods
Dimensions (W×H×D)150 × 450 × 275 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
TypeImported Instrument
ModelCS-131 / CS-131C (with integrated cooler)
Measurement PrincipleUV-Vis Absorption Spectrophotometry
AnalyteSC-1 solution (NH₃ / H₂O₂ / H₂O)
Response Time≈2 s (excluding fluid exchange & cooling time)
NH₃ Range Options0.00–1.00%, 0.00–3.00%, or 0.00–5.00% w/w
H₂O₂ Range Options0.00–5.00%, 0.00–7.00%, or 0.00–10.00% w/w
H₂O Range85.0–100.0% w/w
RepeatabilityNH₃ ±0.15–±0.25%, H₂O₂ ±0.3%, H₂O ±1.5%
Operating Temp.CS-131: 20–30°C
CS-131C20–80°C
Flow RateCS-131: 20–60 mL/min
CS-131C20–40 mL/min
Pressure0.10–0.20 MPa
Power SupplyDC 24 V ±10%, 2 A
Output InterfacesRS-232C, 4–20 mA (dual-channel), open-collector digital outputs, opto-isolated parallel inputs
Dimensions (W×D×H)CS-131: 205 × 329 × 269 mm
CS-131C291 × 329 × 269 mm
WeightCS-131: ~11 kg
CS-131C~12 kg
Tubing3 mm OD / 2 mm ID (Nippon Pillar Super fittings)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelORP-11
TypeLaboratory ORP Meter
Measurement Range−1000 to +1000 mV
Accuracy±2 mV
Minimum Sample Volume0.3 mL (0.05 mL with sampling sheet)
CalibrationAuto-recognition of 225 mV standard solution, customizable with other ORP standards
Temperature RangeUp to 50.0 °C with automatic temperature compensation
Protection RatingIP67
DisplayBacklit LCD
Operating ModeAuto-hold with stability indicator (smiley icon)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0