- All
- Favorite
- Popular
- Most rated
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 719 SET Basic |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HO-200 |
| Type | Industrial Online ORP Meter |
| ORP Range | −2000 to +2000 mV |
| Temperature Range | 0 to 100 °C |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| ORP Repeatability | ±5 mV |
| Temperature Repeatability | ±0.3 °C (equivalent input) |
| Linearity | ±5 mV (ORP), ±0.3 °C (temperature) |
| Output | Two isolated 4–20 mA DC outputs (load ≤ 900 Ω) |
| Relay Outputs | Three SPDT dry-contact relays (R1, R2, FAIL) |
| Input | One opto-isolated contact input for external cleaning command |
| Communication | Isolated RS-485 (2-wire) |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ≤15 W |
| Enclosure | Aluminum, IP65-rated |
| Operating Ambient Temperature | −20 to +55 °C |
| Mounting | Wall or 50A pole mount |
| Weight | ~4.5 kg |
| Compliance | CE marking, FCC Rules, RoHS, WEEE |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 794 Standard |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10000 of selected volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | 0 to ±127 µA |
| Polarization Potential | 0 to ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 702 Economy |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10,000 of selected volume |
| Absolute Burette Error | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Current Compensation | <3.1 × 10⁻¹³ A |
| Thermal EMF Compensation Drift | 15 µV/K |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarizable electrode, 1 temperature sensor |
| Polarization Range | Current 0 to ±127 µA |
| Differential Amplifier | Optimized for low-conductivity non-aqueous titrations |
| Method Storage Capacity | 100 pre-programmed or user-defined methods |
| Dimensions (W × H × D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Type | Imported Instrument |
| Model | 785 Universal |
| Pricing | Upon Request |
| Measurement Range | pH 0 to ±20.00 |
| Potential | ±2000 mV |
| Current | ±200.0 µA |
| Temperature | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Resolution | 1/10,000 of burette volume |
| Absolute Accuracy | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance indicator electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Origin | Switzerland |
|---|---|
| Titration Volume Options | 1, 2, 5, 10, 20, or 50 mL |
| pH Range | 0 to ±20.00 |
| Potential Range | ±2000 mV |
| Current Range | ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Titration Resolution | 1/10,000 of burette volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring, 1 reference, 1 polarization, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |
| Origin | Japan |
|---|---|
| Type | Imported Instrument |
| Model | CS-131 / CS-131C (with integrated cooler) |
| Measurement Principle | UV-Vis Absorption Spectrophotometry |
| Analyte | SC-1 solution (NH₃ / H₂O₂ / H₂O) |
| Response Time | ≈2 s (excluding fluid exchange & cooling time) |
| NH₃ Range Options | 0.00–1.00%, 0.00–3.00%, or 0.00–5.00% w/w |
| H₂O₂ Range Options | 0.00–5.00%, 0.00–7.00%, or 0.00–10.00% w/w |
| H₂O Range | 85.0–100.0% w/w |
| Repeatability | NH₃ ±0.15–±0.25%, H₂O₂ ±0.3%, H₂O ±1.5% |
| Operating Temp. | CS-131: 20–30°C |
| CS-131C | 20–80°C |
| Flow Rate | CS-131: 20–60 mL/min |
| CS-131C | 20–40 mL/min |
| Pressure | 0.10–0.20 MPa |
| Power Supply | DC 24 V ±10%, 2 A |
| Output Interfaces | RS-232C, 4–20 mA (dual-channel), open-collector digital outputs, opto-isolated parallel inputs |
| Dimensions (W×D×H) | CS-131: 205 × 329 × 269 mm |
| CS-131C | 291 × 329 × 269 mm |
| Weight | CS-131: ~11 kg |
| CS-131C | ~12 kg |
| Tubing | 3 mm OD / 2 mm ID (Nippon Pillar Super fittings) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ORP-11 |
| Type | Laboratory ORP Meter |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±2 mV |
| Minimum Sample Volume | 0.3 mL (0.05 mL with sampling sheet) |
| Calibration | Auto-recognition of 225 mV standard solution, customizable with other ORP standards |
| Temperature Range | Up to 50.0 °C with automatic temperature compensation |
| Protection Rating | IP67 |
| Display | Backlit LCD |
| Operating Mode | Auto-hold with stability indicator (smiley icon) |
Show next