| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D / 9625-10D |
| Construction | Integrated Glass pH Sensor, Reference Electrode, and Pt1000 Temperature Sensor |
| Body Material | 9615-10D — Glass Shaft |
| Membrane Type | ToupH Thick-Film Glass (9615-10D) |
| Internal Electrolyte | KCl 3.0 mol/L (Ref. #300) |
| Application Focus | Municipal drinking water, ultrapure water, low-buffered samples, field-deployable environmental monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615S-10D |
| pH Range | 0–14 |
| Temperature Range | 0–100 °C |
| Temperature Sensor | Integrated Pt1000 or NTC (configurable) |
| Cable Length | 1 m |
| Connector | BNC + Phono (RCA) |
| Overall Length | 151 mm |
| Diameter | 12 mm |
| Fill Solution | 3.33 M KCl (HORIBA Ref. 525-3 or 300) |
| Construction | Lead-free thick-film glass membrane, waterproof IP67-rated body |
| Electrode Type | Refillable combination electrode |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | Ca-11C |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Sample Volume | ≥0.3 mL |
| Measurement Range | 0.1–5.0 mmol/L |
| Resolution | 0.1 mmol/L |
| Accuracy | ±20% of reading |
| Calibration Points | 2-point (1.25 mmol/L and 2.50 mmol/L) |
| Display | Backlit monochrome LCD |
| Operating Temperature | 5–40.0 °C |
| Operating Humidity | ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 batteries |
| Housing Material | ABS epoxy resin |
| Dimensions | 164 × 29 × 20 mm (excluding protrusions) |
| Weight | Approx. 55 g (including sensor and batteries) |
| IP Rating | IP67 |
| Key Functions | Auto-standard recognition, auto-hold/auto-stabilize measurement, auto-power-off (30 min), low-battery indicator, replaceable calcium ISE sensor |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HP-480 |
| Measurement Principle | Glass Electrode Method |
| pH Range | 0–14 |
| pH Resolution | 0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 1 °C (selectable display) |
| Accuracy (pH) | ±0.05 pH (equivalent input) |
| Linearity (pH) | ±0.05 pH (equivalent input) |
| Output Signal | 4–20 mA DC, isolated, max load ≤ 600 Ω |
| Relay Outputs | 2 × SPDT (240 V AC / 30 V DC, 3 A resistive) |
| Calibration | 2-point auto/manual (pH 2/4/7/9/10 JIS standards) |
| Temperature Compensation | Selectable RTD types (350 Ω, 500 Ω, 1 kΩ, 6.8 kΩ, 10 kΩ) or none |
| Self-Diagnosis | Asymmetry potential, slope deviation, response time anomaly, reference junction fault, sensor open/short, out-of-range detection |
| Enclosure Rating | IP65 (panel-mounted, indoor use) |
| Operating Ambient | −5 to +45 °C |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤10 W |
| Certifications | CE, FCC |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WAK Series |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-712 |
| Measurement Principle | Glass Electrode Method |
| Sample Volume | ≥0.05 mL (with sampling film B) |
| pH Range | 2.0–12.0 |
| Calibration | One-point or Two-point (user-selectable) |
| Accuracy | ±0.1 pH (after calibration, repeatability in standard buffer) |
| Temperature Compensation | Automatic (ATC) |
| Auto-Hold | Yes |
| Ingress Protection | IP67 (1 m submersion for 30 min |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power | Two CR2032 batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HD-480 (Electrochemical Membrane-Type), HD-200FL (Optical Fluorescence-Based) |
| Measurement Principle | Clark-type membrane electrode (HD-480) |
| Output Signal | 4–20 mA, RS-485 (Modbus RTU) |
| Operating Temperature | 0–50 °C |
| IP Rating | IP66/IP67 |
| Power Supply | 12–24 VDC |
| Sensor Cable Length | Standard 5 m (extendable up to 30 m) |
| Compliance | CE, RoHS, ISO 5814:2012 (DO measurement), ASTM D888-22 (dissolved oxygen in water) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |