Empowering Scientific Discovery

Shanghai Xinlian Chuangzuo

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelSpectraProbe XE (SPXE)
Optical Geometry0°/45° annular
Measurement Aperture65 mm
Sampling Rateup to 24 Hz
Wavelength Range400–700 nm
Spectral Resolution<3 nm
Bandwidth12 nm (FWHM)
Detector256-element silicon photodiode array
Light SourcePulsed xenon lamp (≥10⁷ flashes)
UV CorrectionAutomatic at 420 nm
CIE IlluminantD65
Colorimetric Repeatability<0.02 ΔE*ab (20 readings on white tile)
Wavelength Repeatability<0.10% (420–680 nm), <0.15% (400–420 nm)
Stability0.05 ΔL*a*b* peak (30 min), 0.15 ΔL*a*b* peak (4 h)
Operating Temperature10–50 °C
Enclosure RatingNEMA 4 / IP65
Analog Outputs4 × 4–20 mA (user-configurable tolerances)
CommunicationRS-232 / RS-422
SoftwareEasyMatch OL
Power120–220 VAC, 48–62 Hz, 5.5 A
Compressed Air80 psig, 2 cfm (for lens purge)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelBPI Spectrophotometer
Wavelength Range350–710 nm
Optical Resolution<10 nm
Measurement OutputsVisible Transmittance (Tv), UVA Transmittance, CIELAB L*a*b* color coordinates
Dimensions6.75" × 6.25" × 5" (L×W×H)
Weight8.5 lb
Power Supply110 V AC, 50/60 Hz, 1 A
InterfaceUSB 2.0
Operating SystemMicrosoft Windows
Data StorageIntegrated database + exportable reports
ComplianceSupports ASTM D1003 (haze/transmittance), EN 1836:2015 (sunglasses), DOT FMVSS No. 208 & 212 (traffic signal visibility), ISO/CIE colorimetric standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorTrend HT (CTHT)
Optical Geometry0°/45° dual-beam
Wavelength Range400–700 nm
IlluminantC
Observer Angle
Measurement Spot Diameter20 mm
Measurement Distance50–150 mm
Illumination/Detection Area35 mm / 25 mm
Color Resolution±0.1 CIELab units
Height Resolution±0.1 mm
Repeatability (24 h, no recalibration)< ±0.5 CIELab units
OutputFour user-configurable CIE tristimulus values + height via isolated 4–20 mA channels
Environmental RatingNEMA 4 / IP65
Operating Temperature10–50 °C
Power Supply90–250 VAC, 47–63 Hz
CommunicationRS-232 or RS-485
ComplianceDesigned for GLP/GMP-aligned process monitoring environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex L2 Tomato
Spectral Range400–700 nm
Spectral Resolution< 3 nm
Effective Bandwidth10 nm (triangular equivalent)
Illumination Geometry45°/0° directional, specular component excluded
Measurement Aperture31.8 mm illumination / 25.4 mm measurement
Photometric Range0–150%
Light SourceFull-spectrum xenon lamp (10-year typical lifetime)
Measurement Time1 second
Instrument RepeatabilityΔE*2000 < 0.03 (D65/10°, white tile, 20 readings)
Inter-instrument AgreementΔE*2000 < 0.15 (D65/10°, BCRA CCSII tiles)
ComplianceCIE 15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C
TraceabilityNIST-traceable calibration per CIE Pub. 44 and ASTM E259
Display7″ capacitive touchscreen (1280×800)
Dimensions16 × 21 × 24 cm
Weight2.75 kg
Power90–240 VAC, 47–63 Hz → 24 VDC/3.75 A
Operating Environment10–30 °C, 10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelMiniScan XE Plus (MSXEPlus)
Geometry45°/0° integrating sphere
Aperture OptionsLAV (31.8 mm), SAV (6.0 mm), VSAV (25.0 mm), LAV (14.3 mm), SAV (6.0 mm)
Measured Area25.0 mm, 5.0 mm, 20.0 mm, 8.3 mm, 4.0 mm
Repeatability (BCRA II tile set, avg ΔE*)0.05 / 0.25 / 0.15 / 0.15 / 0.15
Spectral Range400–700 nm
Spectral Bandpass<12 nm
Wavelength Accuracy±1 nm
Spectral Resolution10 nm
Light SourcePulsed Xenon Lamp (>500,000 flashes)
Display6.4 cm × 6.4 cm LCD
Viewing Angles0°, 90°, 180°, 270°
IlluminantsA, C, D65, F2, F7, F11 (TL84), F12
Observers2° and 10° standard observer
Color SpacesCIE L*a*b*, L*C*h°, XYZ, Yxy, Hunter L,a,b
Color Difference MetricsΔE*, ΔE(CMC), ΔE(ISO 11664-4), ΔL*, Δa*, Δb*, ΔC*, ΔH*, ΔE00 (optional via software), ΔE(FMC II), Z%, Metamerism Index (MI), Gray Scale (ISO 105-A02/A03/A04/A05)
Sample TypesOpaque solids, translucent solids, powders, pastes, fluorescent materials, metallics, transparent films (with optional accessories)
Dimensions10.2 cm × 12.7 cm × 25.4 cm
Weight1.3 kg (3 lbs)
PowerRechargeable NiCd battery pack or external 120/220 V AC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex L2 (CFL2)
Spectral Range400–700 nm
Spectral Resolution< 3 nm
Effective Bandwidth10 nm
Illuminant OptionsA, C, D50, D55, D65, D75, F2, F7, F11
Observer Angles2° and 10°
Geometry45°/0° (specular component excluded)
Aperture31.8 mm illumination / 25.4 mm measurement
RepeatabilityΔE*2000 < 0.03 (D65/10°, white tile, 20 readings)
Inter-instrument AgreementΔE*2000 < 0.15 (D65/10°, BCRA CCSII tiles)
Light SourcePulsed xenon lamp (10-year typical lifetime)
Measurement Time1 second
ComplianceCIE 15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C
TraceabilityNIST-traceable calibration per CIE Pub. 44 and ASTM E259
Display7″ capacitive touchscreen (1280 × 800)
Dimensions16 cm H × 21 cm W × 24 cm D
Weight2.75 kg
Power90–240 VAC, 47–63 Hz → 24 VDC/3.75 A
Operating Environment10–30 °C, 10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex L2
Spectral Range400–700 nm
Spectral Resolution< 3 nm
Effective Bandwidth10 nm
Illuminant OptionsA, C, D50, D55, D65, D75, F2, F7, F11
Observer Angles2° and 10°
Geometry45°/0° (specular component excluded)
Aperture31.8 mm illumination / 25.4 mm measurement
RepeatabilityΔE*2000 < 0.03 (D65/10°, white tile, 20 readings)
Inter-instrument AgreementΔE*2000 < 0.15 (D65/10°, BCRA CCSII tiles)
Light SourcePulsed Xenon Lamp (10-year typical lifetime)
Measurement Time1 second
ComplianceCIE 15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C
TraceabilityNIST-traceable calibration per CIE Pub. 44 and ASTM E259
Display7-inch high-resolution touchscreen (1280 × 800)
Dimensions16 cm H × 21 cm W × 24 cm D
Weight2.75 kg
Operating Environment10–30 °C, 10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex L2
Spectral Range400–700 nm
Spectral Resolution< 3 nm
Effective Bandwidth10 nm
Illuminant OptionsA, C, D50, D55, D65, D75, F2, F7, F11
Observer Angles2° and 10°
Geometry45°/0° directional (specular component excluded)
Aperture31.8 mm illumination / 25.4 mm measurement
RepeatabilityΔE*2000 < 0.03 (D65/10°, white tile, 20 readings)
Inter-instrument AgreementΔE*2000 < 0.15 (D65/10°, BCRA CCSII tiles)
Light SourcePulsed xenon lamp (10-year typical lifetime)
Measurement Time1 second
ComplianceCIE 15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C
TraceabilityNIST-traceable calibration per CIE Pub. 44 and ASTM E259
Display7-inch capacitive touchscreen (1280×800)
Dimensions (H×W×D)16 × 21 × 24 cm
Weight2.75 kg
Power90–240 VAC, 47–63 Hz, converted to 24 VDC/3.75 A
Operating Environment10–30 °C, 10–90% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelD25A-DP9000 (D25A)
Optical Geometry45°/0° (dual-beam, 2-inch aperture, reducible to 1/8-inch)
IlluminantC (CIE Standard Illuminant C)
Observer2° Standard Observer
Color SpacesCIE XYZ, Yxy, Hunter Lab, CIE L*a*b*, CIE L*C*h°, FMC-2
Color IndicesWI E313, YI E313, YI D1925, Opacity, TAPPI Brightness, Z%, Tomato Grade, ΔE, ΔEcmc, ΔC, ΔE*, ΔC*
Repeatability<0.02 SD (XYZ, 20 readings)
Measurement Time<1 second
Display40×8 backlit LCD with icon-driven membrane keypad
Data Storage300 sample readings + 99 product setups (battery-backed memory)
InterfaceRS-232C bidirectional serial port (ASCII, DIF, WK1 formats)
PrinterBuilt-in 40-column thermal printer
Operating Environment14–50°C, 0–85% RH non-condensing
ComplianceMeets ASTM E308, ISO/CIE 11664, TAPPI T452, USP <1061>, FDA 21 CFR Part 11 (audit trail enabled via software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHunterLab D25L-DP9000 (D25L) Colorimeter and Color Difference Meter
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex L2 CFL2
Spectral Range400–700 nm
Spectral Resolution< 3 nm
Effective Bandwidth10 nm
Photometric Range0–150%
Light SourceFull-spectrum Xenon Lamp (10-year typical lifetime)
Measurement Time1 second
Geometry45°/0° directional, specular component excluded
Aperture31.8 mm illumination / 25.4 mm measurement
Instrument RepeatabilityΔE*2000 < 0.03 (D65/10°, white tile, 20 readings)
Inter-instrument AgreementΔE*2000 < 0.15 (D65/10°, BCRA CCSII tiles)
ComplianceCIE 15:2004, ISO 7724-1, ASTM E1164, DIN 5033-7, JIS Z 8722 Condition C
Display7″ capacitive touchscreen (1280×800)
Dimensions16 × 21 × 24 cm
Weight2.75 kg
Power90–240 VAC, 47–63 Hz → 24 VDC/3.75 A
Operating Environment10–30°C, 10–90% RH (non-condensing)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0