- All
- Favorite
- Popular
- Most rated
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Internal Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-type NiCr wire |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock, gas leak alarm with heater shutdown, purge timer, pressure monitoring, blow-down relief valve |
| Insulation | 6-inch mineral wool |
| Door Seal | High-temp fiberglass gasket |
| Cooling | Air-cooled (IGF-7780) |
| Compliance | NFPA 86 Class B oven |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | T2 |
| Temperature Range | −70 °C to +180 °C |
| Humidity Range | 20–95 % RH (at dry-bulb 20–85 °C, dew point ≥5 °C) |
| Temperature Uniformity | ±1.0 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Deviation | ±1.0 °C |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Refrigerant | Non-CFC, environmentally compliant |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | SafeTest Battery Test |
| Temperature Range | -68°C to +180°C |
| Uniformity | ±1.0°C |
| Stability | ±1.0°C |
| Deviation | ±1.0°C |
| Max Operating Temperature | 200°C |
| Internal Dimensions (W×H×D) | 521 mm × 508 mm × 559 mm |
| Type | Forced-Air Thermal Aging Chamber for Battery Safety Testing |
| Compliance Support | EUCAR Hazard Level Assessment, ISO 12405, UL 1642, UN 38.3, IEC 62133, SAE J2464 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SP-Y-1908 |
| Pricing | Available Upon Request |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | LUNAIRE WSS |
| Temperature Range | −70 °C to +180 °C |
| Temperature Uniformity | ±1.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ±1.0 °C |
| Ramp Time | Ambient to 180 °C |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Chamber Volume Options | 288 ft³, 512 ft³, 800 ft³ |
| Application Class | Air-Heating Thermal Aging Chamber |
| Compliance Context | Designed for ICH Q1A(R3), USP <1151>, FDA 21 CFR Part 11 (with optional audit trail software), and GLP/GMP environmental validation protocols |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG1 / NG2 / NG3 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminum (polished & EDT), ZnMg-coated steel |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, hot-melt adhesives, waxes, other organics (with custom calibration) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-8880 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Heating Element | Open-wire Ni-Chrome |
| Inert Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Features | Door interlock (heater & blower shutdown), gas leak alarm with automatic heater cutoff, pressure monitoring, purge timer, pressure relief valve, water-cooled door (IGF-8880/9980 models) |
| Insulation | 6-inch mineral wool |
| Door Seal | Fiberglass-reinforced silicone gasket |
| Compliance | NFPA 86 Class B |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGO3-WATER |
| Price Range | USD 65,000 – 130,000 |
| Brand | DJH Designs |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Wolf DFM Alpha |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | NG2 |
| Pricing | Upon Request |
| Brand | Blue M |
|---|---|
| Model | IGF 6680 / IGF 7780 / IGF 8880 / IGF 9980 |
| Origin | USA |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Uniformity | ±2% of setpoint |
| Stability | ±2% of setpoint |
| Accuracy | ±0.5°C |
| Resolution | ±0.1°C |
| Internal Chamber Dimensions (W×H×D) | 25×20×20 cm (IGF 7780) |
| Heating Element | Open-wire NiCr |
| Insulation | 6-inch mineral wool |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂/96% N₂) |
| Safety Features | Door interlock (heater & blower shutdown), inert gas leak detection with audible/visual alarm and heater disable, pressure monitoring, purge timer, pressure relief valve, water-cooled door (IGF 8880 & 9980) |
| Compliance | NFPA 86 Class B |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGO3-WATER |
| Price Range | USD 68,000 – 136,000 |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | STRAT Altitude Simulation Test Chamber |
| Temperature Range | -68°C to +177°C |
| Altitude Simulation Range | Up to 200,000 ft (≈60,960 m) |
| Humidity Range (xxSTR models only) | 20–98% RH |
| Temperature Uniformity | ±0.3°C |
| Temperature Stability | ±0.3°C |
| Temperature Deviation | ±0.3°C |
| Ramp Time (to max temp) | ≤60 min |
| Internal Volume | 5–64 ft³ (0.14–1.81 m³) |
| Vacuum Control | Capacitive pressure sensor with automated vacuum/exhaust valves |
| Refrigeration System | Dual-stage cascade with two semi-hermetic compressors |
| Heating | Open-wire NiCr heating elements |
| Interior | Continuously welded stainless steel airtight liner |
| Controller | Synergy Quattro touchscreen (320×240 color LCD), Windows CE OS, PID with auto-tuning, dual-channel operation, USB/RS-232/Ethernet (10/100) connectivity, flash memory logging, alarm outputs, I/O expansion via OLYMPUS module |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | TC |
| Temperature Range | -70°C to +180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Ramp Rate (Ambient to 180°C) | Standard |
| Internal Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Chamber Type | Air Thermal Aging Test Chamber |
| Cooling System | Single-Stage or Cascade Refrigeration |
| Controller | Watlow F4T with INTUITION™ Process Control |
| Compliance | Designed for GLP/GMP environments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Infralytic NG2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGO3-WATER |
| Price Range | USD 68,000 – 136,000 |
| Measurement Principle | Multi-Wavelength Near-Infrared Absorption Spectroscopy |
| Measurand | Oil Film Thickness / Moisture Content (g/m² or mg/m²) |
| Standoff Distance | 200 mm |
| Tolerance for Strip Height Variation | ±20 mm |
| Dimensions (L×W×H) | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Operating Temperature | 0 °C to +55 °C |
| Measurement Frequency | ≤120 Hz |
| Substrate Compatibility | Ferrous & Non-Ferrous Metals, Ceramic Surfaces |
| Minimum Measurement Time | 50 ms |
| Optical Configuration | P-Polarized Triple-Wavelength IR Detection |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | Tenney Junior |
| Temperature Range | -68°C to +180°C |
| Uniformity | ±1.0°C |
| Stability | ±1.0°C |
| Deviation | ±1.0°C |
| Ramp Rate (Ambient to 200°C) | 60 min |
| Internal Volume | 1.2–64 ft³ (0.034–1.812 m³) |
| Controller | Watlow F4T with INTUITION™ Process Control |
| Compliance | CE-marked (50/60 Hz), NIST-traceable calibration available, ISO/IEC 17025-compliant calibration services offered |
| Construction | Continuously welded stainless steel interior, fiberglass insulation, hermetic seal |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | 8.5SVO |
| Temperature Range | Ambient +15°C to +200°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | ≤100 min (from ambient to max temperature) |
| Internal Chamber Dimensions (W×H×D) | 597 mm × 698 mm × 597 mm (23.5" × 27.5" × 23.5") |
| Internal Volume | 8.5 ft³ / 240 L |
| Vacuum Capability | Down to 8 Torr (mmHg) |
| Power Supply | 230 V, 3-Phase, 60 Hz |
| Rated Power | 4 kW |
| Standard Shelves | 2 adjustable stainless steel shelves |
| Construction | Dual-wall heavy-gauge steel cabinet with fiberglass insulation |
| Door | Full-view tempered glass window with high-temp silicone gasket |
| Control System | Ethernet-enabled touchscreen PID controller with data logging and profile programming |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥6000 lm |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | IGF-7780 |
| Temperature Range | Ambient +15°C to 593°C (1099°F) |
| Max Operating Temperature | 400°C |
| Uniformity | ±2% of setpoint |
| Temperature Stability | ±2% of setpoint |
| Temperature Deviation | ±0.5°C |
| Chamber Dimensions (W×H×D) | 25 × 20 × 20 cm |
| Internal Volume | 5.8 ft³ (0.164 m³) |
| Gas Compatibility | N₂, Ar, He, CO₂, and forming gas (4% H₂ in N₂) |
| Safety Certifications | NFPA 86 Class B |
| Heating System | Open-wire NiCr elements |
| Insulation | 6-inch mineral wool |
| Door Seal | High-temp fiberglass gasket |
| Cooling | Air-cooled door (IGF-7780) |
| Control Resolution | ±0.1°C |
| Exhaust | Adjustable damper with purge timer |
| Interlocks | Door switch (heater/fan shutdown), gas leak detection alarm, pressure monitoring |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NGO3-W |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measuring Distance | 200 mm |
| Measurement Range | Water & Emulsion Residue (0.1–500 mg/m²) |
| Accuracy | ±5% of reading (typical, dependent on surface uniformity and substrate emissivity) |
| Repeatability | <±2 mg/m² |
| Sampling Frequency | Up to 120 Hz |
| Standoff Tolerance | ±20 mm vertical deviation |
| Operating Temperature | 0 °C to +55 °C |
| Enclosure Rating | IP65 |
| Dimensions (L×W×H) | 519 × 264 × 100 mm |
| Weight | 8 kg |
| Substrate Compatibility | Ferrous & non-ferrous metals, ceramic-coated strips |
| Output Interface | Analog 4–20 mA, RS-485, Ethernet (Modbus TCP / optional OPC UA) |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61000-6-2/6-4 |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG1 |
| Measurement Principle | Dual-Wavelength Near-Infrared Absorption Spectroscopy |
| Typical Measurement Range | 0.1–20 g/m² (oil equivalent on metal substrates) |
| Accuracy | ±0.05 g/m² (calibrated against reference standards) |
| Repeatability | <±0.02 g/m² |
| Response Time | <1 second per measurement |
| Power Supply | Rechargeable NiMH battery (included) |
| Interface | USB 2.0 with proprietary PC software |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |
| Operating Temperature | 10–40 °C |
| Weight | 0.85 kg (with battery) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CONDITIONED |
| Temperature Range | -68°C to +180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±1.0°C |
| Temperature Deviation | ±1.0°C |
| Ramp Time | Ambient to 180°C |
| Chamber Dimensions (W×H×D) | 521 mm × 508 mm × 559 mm |
| Application | Air Thermal Aging Test Chamber |
| Classification | Environmental Test Chamber / High-Temperature Aging Chamber |
| Brand | Infralytic |
|---|---|
| Origin | Germany |
| Model | NG2 |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Range | 0.05–6 g/m² |
| Accuracy | ±0.015 g/m² (0.02–0.3 g/m²), ±0.2 g/m² (0.3–2 g/m²), ±10% of reading (>2 g/m²) |
| Repeatability | <0.0010 g/m² |
| Resolution | 0.001 g/m² |
| Measurement Distance | 8 mm (+5/−2 mm) |
| IP Rating | IP65 |
| Operating Temperature | 0–45 °C |
| Power Supply | Internal rechargeable battery (≥12 h runtime) |
| Substrate Compatibility | Cold-rolled steel, hot-dip galvanized (HDG), electrogalvanized (EG), phosphated EG, annealed galvannealed (GA), aluminized (Al, Al-Zn, ZnMg), bare and pre-treated surfaces |
| Lubricant Compatibility | Mineral oils, thixotropic mineral oils, waxes, hot-melt adhesives, and other organic lubricants (with custom calibration) |
Show next