- All
- Favorite
- Popular
- Most rated
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | BAMS-3000 |
| Price Range | USD $13,500 – $40,500 (FOB Shanghai) |
| Instrument Category | Real-Time Bioaerosol Detection System |
| Sampling Flow Rate | >200 L/min |
| Detection Sensitivity | ~5 genomic copies per reaction (adjustable) |
| Sample Processing Volume | 0–25 mL |
| Throughput | 92 samples |
| Analysis Time | <30 min per sample |
| Dimensions | 545 × 440 × 475 mm (L×W×H) |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | GB/T 38517–2020, GB/T 39990–2021, GB/T 16293–2010, GB/T 16294–2010, GB/T 18204.3–2013 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LDS |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ICT-208-16-YR / HSP200 |
| Instrument Category | Bioaerosol Detection System |
| Sampling Flow Rate | >200 L/min |
| Particle Size Cutoff | ≥1.0 µm (≥90% collection efficiency) |
| Battery Capacity | 3000 mAh (up to 10 sampling cycles per charge) |
| Sample Throughput | 16 wells |
| Temperature Control Range | Ambient to 85 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C across block |
| Detection Channels | FAM, SYBR Green (HEX optional) |
| Result Time | ≤20 min |
| Display | 10.4″ capacitive touchscreen |
| Dimensions (L×W×H) | 210 × 302 × 200 mm |
| Power Input | 20 V, 6 A |
| Connectivity | RJ45, USB, Wi-Fi |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AirScanner |
| Price Range | USD 68,000–136,000 (FOB) |
| Pollutants Measured | O₃, NO/NO₂, CO, SO₂, CO₂, VOCs, PM₁₀, PM₂.₅ |
| Measurement Principles | UV Photometry (O₃, SO₂), Chemiluminescence (NO/NO₂), NDIR (CO, CO₂), PID (VOCs), β-Attenuation or Optical Scattering (PM) |
| Environmental Parameters | Temperature, Relative Humidity, Wind Speed & Direction, Ambient Noise, Atmospheric Pressure |
| Data Connectivity | GSM/GPRS, Ethernet (LAN/WLAN), RS-232 |
| Enclosure Rating | IP65 |
| Operating Temperature Range | −20 °C to +50 °C |
| Power Supply | 230 V AC ±10%, 50/60 Hz or Solar/Battery Hybrid Option |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HYDRO-CO2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-2020 |
| Pricing | Upon Request |
| Detector Type | Photoionization Detector (PID), 10.6 eV |
| Measurement Range | 0–50 ppm (C₂H₄) |
| Column Configuration | Dual packed columns with backflush capability |
| Carrier Gas | Nitrogen (N₂), regulated flow control |
| Sample Introduction | Six-port multi-position valve with 1 mL sample loop |
| Cycle Time | 420 s typical |
| Data Storage | >2 GB internal flash memory |
| Display Interface | 7-inch capacitive touchscreen LCD (1024 × 600) |
| Rack Mount | 19-inch, 4 HU |
| Analog Output | 4–20 mA / 0–10 V (isolated) |
| Digital Interface | RS-232/RS-485 serial, parallel I/O for PLC integration |
| Auto-Diagnostics | Built-in system self-test with event logging |
| Standby Mode | Low-power operational state with wake-on-trigger capability |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (Safety), compatible with GLP/GMP data integrity requirements |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HYDRO CH4 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EasyDust |
| Measurement Principle | Laser Light Scattering |
| Measurable Parameters | TSP, PM₁₀, PM₂.₅, PM₁ |
| Measurement Range (PM₁₀) | 0.01–2000 µg/m³ |
| Sampling Interval | 1–10 s |
| Sample Flow Rate | 220 mL/min |
| Total Flow Rate | 1.2 L/min |
| Particle Size Range (spherical equivalent diameter) | 0.38–17 µm |
| Max Particle Counting Rate | 10,000 particles/s |
| Detection Limit (PM₁₀) | 0.01 µg/m³ |
| Output Interfaces | RS232 digital, 0–10 VDC analog (optional) |
| Power Supply | 230 V/50 Hz or 115 V/60 Hz |
| Dimensions (with weatherproof enclosure) | 200 × 200 × 150 mm |
| Weight | ~2 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EasyCEM |
| Price Range | USD 70,000–140,000 (FOB) |
| Instrument Principle | NDIR, TDLS, NDUV, PID, EC hybrid optical/electrochemical sensing |
| Product Type | Online Continuous Emission Monitoring System |
| Response Time | t₉₀ < 2 s at 60 L/h |
| Repeatability | ±0.5 % of span and zero |
| Gas Measurement Methods | NDIR for CO, CO₂, NO, SO₂, SF₆, THC |
Show next