Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelBAMS-3000
Price RangeUSD $13,500 – $40,500 (FOB Shanghai)
Instrument CategoryReal-Time Bioaerosol Detection System
Sampling Flow Rate>200 L/min
Detection Sensitivity~5 genomic copies per reaction (adjustable)
Sample Processing Volume0–25 mL
Throughput92 samples
Analysis Time<30 min per sample
Dimensions545 × 440 × 475 mm (L×W×H)
Power Supply220 V AC, 50 Hz
ComplianceGB/T 38517–2020, GB/T 39990–2021, GB/T 16293–2010, GB/T 16294–2010, GB/T 18204.3–2013
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLDS
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional OriginDomestic (PRC)
ModelICT-208-16-YR / HSP200
Instrument CategoryBioaerosol Detection System
Sampling Flow Rate>200 L/min
Particle Size Cutoff≥1.0 µm (≥90% collection efficiency)
Battery Capacity3000 mAh (up to 10 sampling cycles per charge)
Sample Throughput16 wells
Temperature Control RangeAmbient to 85 °C
Temperature Accuracy±0.5 °C
Temperature Uniformity±0.5 °C across block
Detection ChannelsFAM, SYBR Green (HEX optional)
Result Time≤20 min
Display10.4″ capacitive touchscreen
Dimensions (L×W×H)210 × 302 × 200 mm
Power Input20 V, 6 A
ConnectivityRJ45, USB, Wi-Fi
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAirScanner
Price RangeUSD 68,000–136,000 (FOB)
Pollutants MeasuredO₃, NO/NO₂, CO, SO₂, CO₂, VOCs, PM₁₀, PM₂.₅
Measurement PrinciplesUV Photometry (O₃, SO₂), Chemiluminescence (NO/NO₂), NDIR (CO, CO₂), PID (VOCs), β-Attenuation or Optical Scattering (PM)
Environmental ParametersTemperature, Relative Humidity, Wind Speed & Direction, Ambient Noise, Atmospheric Pressure
Data ConnectivityGSM/GPRS, Ethernet (LAN/WLAN), RS-232
Enclosure RatingIP65
Operating Temperature Range−20 °C to +50 °C
Power Supply230 V AC ±10%, 50/60 Hz or Solar/Battery Hybrid Option
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHYDRO-CO2
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelGC-2020
PricingUpon Request
Detector TypePhotoionization Detector (PID), 10.6 eV
Measurement Range0–50 ppm (C₂H₄)
Column ConfigurationDual packed columns with backflush capability
Carrier GasNitrogen (N₂), regulated flow control
Sample IntroductionSix-port multi-position valve with 1 mL sample loop
Cycle Time420 s typical
Data Storage>2 GB internal flash memory
Display Interface7-inch capacitive touchscreen LCD (1024 × 600)
Rack Mount19-inch, 4 HU
Analog Output4–20 mA / 0–10 V (isolated)
Digital InterfaceRS-232/RS-485 serial, parallel I/O for PLC integration
Auto-DiagnosticsBuilt-in system self-test with event logging
Standby ModeLow-power operational state with wake-on-trigger capability
ComplianceDesigned per IEC 61000-6-3 (EMC), EN 61010-1 (Safety), compatible with GLP/GMP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelEasyDust
Measurement PrincipleLaser Light Scattering
Measurable ParametersTSP, PM₁₀, PM₂.₅, PM₁
Measurement Range (PM₁₀)0.01–2000 µg/m³
Sampling Interval1–10 s
Sample Flow Rate220 mL/min
Total Flow Rate1.2 L/min
Particle Size Range (spherical equivalent diameter)0.38–17 µm
Max Particle Counting Rate10,000 particles/s
Detection Limit (PM₁₀)0.01 µg/m³
Output InterfacesRS232 digital, 0–10 VDC analog (optional)
Power Supply230 V/50 Hz or 115 V/60 Hz
Dimensions (with weatherproof enclosure)200 × 200 × 150 mm
Weight~2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEasyCEM
Price RangeUSD 70,000–140,000 (FOB)
Instrument PrincipleNDIR, TDLS, NDUV, PID, EC hybrid optical/electrochemical sensing
Product TypeOnline Continuous Emission Monitoring System
Response Timet₉₀ < 2 s at 60 L/h
Repeatability±0.5 % of span and zero
Gas Measurement MethodsNDIR for CO, CO₂, NO, SO₂, SF₆, THC
Show next