| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M9 Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer | Veolia Water Technologies |
| Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | <1% RSD |
| Analysis Time | 2 min (standard), 4 sec (optional Turbo mode) |
| Calibration Stability | 12 months |
| Sample Temperature Range | 5–95 °C |
| Ambient Temperature Range | 5–40 °C |
| Inlet Pressure | ≤100 psig |
| Sample Flow Rate (online) | >50 mL/min |
| Internal Flow Rate | 0.5 mL/min |
| Display | 7" WVGA color touchscreen (800×480) |
| Outputs | 4–20 mA (×3), digital alarms (×4), binary input (×1), USB device (×1), USB host (×2), Modbus TCP/IP |
| Power | 100–240 V~, 50–60 Hz, 100 VA |
| Enclosure Rating | IP45 |
| Certifications | ETL, CE |
| Weight | 15.8 kg |
| Dimensions (H×W×D) | 54.9 × 45.0 × 26.5 cm |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer | Veolia Water Technologies |
| Type | Online TOC Analyzer |
| Model | M500e |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.03–2500 ppb as TOC |
| Accuracy | ±5% of reading or ±0.1 ppb, whichever is greater |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | RSD <1% or ±0.03 ppb, whichever is greater |
| Linear Range | 0.03–2500 ppb TOC |
| Analysis Time (Continuous Online) | 3 min |
| Calibration Stability | Up to 12 months |
| Sample Flow Rate | ≥50 mL/min |
| Sample Temperature Range | 1–95 °C |
| Sample Pressure Rating | ≤100 psig |
| pH Range for Specified Accuracy | 5.5–8.0 |
| Ozone Tolerance | Continuous exposure to ≤50 ppb O₃ |
| Conductivity Range | 0.01–800 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm or ±1%, whichever is greater |
| Display | 10.1" capacitive touchscreen (1280×800) |
| Connectivity | Ethernet, Wi-Fi (802.11ac/a/b/g/n, dual-band), RS-232, USB, 3× 4–20 mA outputs, 4 alarm relays |
| Communication Protocols | Modbus TCP/IP, PROFINET (standard), PROFIBUS (optional) |
| Enclosure Rating | IP55 |
| Safety Certifications | CE, ETL Listed (UL 61010-1), CSA C22.2 No. 61010-1 |
| Pollution Degree | 2 |
| Operating Environment | Indoor only |
| Dimensions (H×W×D) | 43.4×55.9×28.7 cm |
| Weight | 16.3 kg |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Autosampler for Laboratory TOC Analyzers |
| Instrument Type | Laboratory Total Organic Carbon Analyzer Accessory |
| Detection Principle | High-Temperature Catalytic Oxidation (HTCO) or Supercritical Water Oxidation (SCWO), compatible with Sievers M9 and M5310 C platforms |
| Oxidation Method | 680 °C catalytic combustion or supercritical water oxidation |
| Measurement Range | 0.03 ppb – 50 ppm TOC |
| Accuracy | ±2% of reading or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Precision (RSD) | <1% at ≥100 ppb |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M9 Portable |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Eclipse |
| Pricing | Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M500 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.03–2500 ppb as TOC |
| Accuracy | ±5% of reading or ±0.1 ppb, whichever is greater |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | RSD <1% or ±0.03 ppb, whichever is greater |
| Linear Range | 0.03–2500 ppb as TOC |
| Conductivity Range | 0.01–800 µS/cm |
| Conductivity Accuracy | ±0.005 µS/cm or ±1%, whichever is greater |
| Sample Flow Rate | ≥50 mL/min |
| Sample Temperature | 1–95 °C |
| Sample Pressure | ≤100 psig |
| pH Range for Specified Accuracy | 5.5–8.0 |
| Ozone Tolerance | Continuous exposure to ≤50 ppb O₃ |
| Analysis Time (Continuous Mode) | 3 min |
| Power Supply | 100–240 VAC, 50/60 Hz, 70 W |
| IP Rating | IP55 |
| Safety Certifications | CE, ETL Listed (UL 61010-1), CSA C22.2 No. 61010-1 |
| Environmental Class | Indoor use only |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | DataGuard |
| Software Type | Regulatory-Compliant Laboratory Data Integrity Software |
| Regulatory Compliance | FDA 21 CFR Part 11, Annex 11, ALCOA+ Principles |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Soleil |
| Instrument Type | Fully Automated Rapid Microbial Method (RMM) Platform |
| Dimensions | 48.3 cm × 43.2 cm × 43.2 cm |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M5310 C Portable |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.1 ppb |
| Detection Limit | 4 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M5310 C Laboratory |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.1 ppb |
| Detection Limit | 4 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported |
| Model | Sievers Boron |
| Pricing | Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Boron Ultra |
| Pricing | Available Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CheckPoint |
| Instrument Type | Portable & Online TOC Analyzer |
| Measurement Principle | Direct Conductivity (DC) Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.05–1000 ppb C (CheckPointe) |
| Accuracy | ±5% (at 500 ppb C sucrose) |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.05 ppb C |
| Precision (Online Mode) | RSD <1% or 0.05 ppb (whichever is greater, CheckPointe) |
| Data Output Interval | Adjustable from 15 seconds to 8 hours |
| Sample Temperature Range | 10–90 °C (CheckPoint Pharma) |
| Ambient Operating Temperature | 10–55 °C (Pharma) |
| Pressure Rating | 103–690 kPa (15–100 psig) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 60 W |
| Certifications | CE, ETL listed |
| Regulatory Compliance | FDA 21 CFR Part 11 ready (via USB printer support), GLP/GMP-aligned IQ/OQ/PQ protocols |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | M5310 C Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 4 ppb – 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.1 ppb |
| Detection Limit | 4 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx ES Lab |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 50 ppb – 50,000 ppm TOC |
| Accuracy | ±3% of reading or ±0.25 ppm (whichever is greater), for 1–100 ppm NPOC/TOC |
| Resolution | 0.001 ppb |
| Detection Limit | 50 ppb NPOC |
| Repeatability | RSD ≤ 3% (>5 ppm NPOC or TOC) |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sievers M9e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb to 50 ppm |
| Accuracy | ±2% or ±0.5 ppb (whichever is greater) |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | <1% RSD |
| Brand | Sievers / Veolia |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Sievers InnovOx Online |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | Supercritical Water Oxidation (SCWO) |
| Measurement Range | 0.5 – 50,000 ppm TOC |
| Accuracy | ±3% (at 50 ppm NPOC) |
| Resolution | 0.001 ppb |
| Detection Limit | 0.05 ppm NPOC |
| Repeatability | RSD ≤ 1.5% |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DataShare Elite |
| Software Type | Laboratory Data Management & Compliance Software |
| Regulatory Compliance | 21 CFR Part 11, ALCOA+, cGMP |
| Compatible Instruments | Sievers M9/M9e, M500, 900, 500 RL, CheckPoint |
| Deployment | Windows 10/Server 2016–2019 |
| Database Engine | Microsoft SQL Server Express (included) |
| Authentication | Active Directory (AD) Integration |
| Audit Trail | Full electronic audit trail with time-stamped, immutable records |
| Electronic Signatures | Role-based e-signature support for calibration, validation, and sample release |
| LIMS Integration | Standardized API and CSV export for seamless LIMS interoperability |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Category | Imported Instrument |
| Model | M9 SEC |
| Instrument Type | Benchtop TOC Detector for SEC Integration |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.03 ppb – 50 ppm TOC |
| Accuracy | ±2% or ±0.5 ppb |
| Resolution | 0.01 ppb |
| Detection Limit | 0.03 ppb |
| Repeatability | <1% RSD |