Spectroscopy Instruments
Filter
Showing 421–450 of 2607 results
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Instrument |
| Model | OmegaAnalyzer G |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating Scanning |
| Wavelength Range | 730–1100 nm |
| Scan Speed | 50 s per measurement |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ALPHA II |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Spectral Range | 7500–375 cm⁻¹ |
| Spectral Resolution | 0.8 cm⁻¹ |
| Scan Speed | 3 spectra/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Online Process Spectrometer |
| Model | BEAM |
| Design | Single-Channel FT-NIR |
| Sample Interface | In-line / At-line (pipeline, hopper, conveyor-mountable) |
| Optical Principle | Interferometric Fourier Transform Spectroscopy |
| Spectral Range | Typically 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | ≤4 cm⁻¹ (user-selectable) |
| Detector | Thermoelectrically Cooled InGaAs |
| Measurement Mode | Real-time, Continuous, Non-destructive |
| Compliance | Designed for GMP/GLP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BRAVO |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 300–3200 cm⁻¹ |
| Spectral Resolution | 10–12 cm⁻¹ |
| Spatial Resolution | 1–2 mm spot diameter |
| Minimum Wavenumber | 300 cm⁻¹ |
| Spectral Reproducibility | ±100% (relative intensity stability across repeated acquisitions under identical conditions) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSAS |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 280–1500 cm⁻¹ |
| Cooling Method | Closed-Cycle Cryocooler (No Liquid Helium Required) |
| Detection Temperature | <15 K |
| Compliance | ASTM/SEMI MF1630 (B, P), ASTM/SEMI MF1391 (C, O) |
| Sensitivity | Boron/Phosphorus down to ppta |
| Vacuum System | Dual-Stage (Mechanical + Turbo Molecular Pump) |
| Sample Capacity | 9-Position Precision Stepper Motor Stage |
| Sample Holder | Gold-Plated OFHC Copper for Thermal Uniformity |
| Software | Dedicated Industrial QC Interface with Touchscreen Control & Automated Reporting |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | IFS 125HR |
| Instrument Type | Laboratory FTIR Spectrometer |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Configuration | Dual-Sample Chamber, Vacuum-Optimized |
| Optional Features | Dual-Sided Interferogram Acquisition, Hybrid Scanner Interferometer with Sliding Bearings, Integrated 24-bit Digitect™ ADC, Ethernet Data Interface |
| Spectral Range Extension Capability | Far-IR (down to 125 cm⁻¹) to UV (via optional sources/detectors) |
| Resolution Capability | < 0.0225 cm⁻¹ (at specified conditions) |
| Vacuum Compatibility | Yes |
| Compliance Context | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | INVENIO |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8,000 – 350 cm⁻¹ |
| Spectral Resolution | 0.16 cm⁻¹ |
| Scan Speed | 20 spectra/sec |
| Signal-to-Noise Ratio | >10,000:1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | LUMOS II ILIM |
| Instrument Type | Laboratory-based Laser IR Microscope |
| Instrument Category | FTIR Imaging Microscope with Integrated Laser Illumination Module |
| Application Domain | Chemical Imaging, Spatially Resolved Spectroscopy, Hyperspectral Mapping |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX-F II |
| Instrument Type | Online FT-NIR Spectrometer |
| Measurement Principle | Fourier Transform (FT) Interferometry |
| Sampling Modes | Diffuse Reflectance, Transflectance, Liquid Transmission (with variable-pathlength fiber-optic probes) |
| Chemometrics Software | OPUS |
| Compliance | Designed for industrial process environments per IEC 61508 SIL2-ready architecture |
| Connectivity | Ethernet with support for OPC UA, Modbus TCP, and Profibus DP |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Models | mq20, mq10 |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| FT-IR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 6000 – 670 cm⁻¹ |
| Detector | Thermoelectrically Cooled MCT (TE-MCT), No Liquid Nitrogen Required |
| Enclosure Rating | IP65 (Instrument Body), IP67 (Carrying Case) |
| Light Source | CenterGlow™ Broadband IR Source (Lifespan >5 years) |
| Interferometer | RockSolid™ Dynamic Alignment-Free Design (Lifespan >10 years) |
| Laser | Solid-State Diode Laser (Lifespan >10 years) |
| ATR Accessory | Heated Diamond Crystal |
| Power Supply | Integrated Rechargeable Lithium Battery (Field-Operable, Grid-Independent) |
| Software Platform | OPUS TOUCH™ (Touch-Optimized, Role-Based Workflow Interface) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MOVE-T |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Design | Benchtop, Flow-Through Configuration |
| Sample Form | Liquid dairy matrices only |
| Compliance Context | Designed for routine QC in dairy processing per ISO 9622:2013, IDF 141:2000, and AOAC Official Method 972.16 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MPA III |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared Spectroscopy |
| Wavelength Range | 12500–3600 cm⁻¹ |
| Scan Speed | 8 scans/sec at 8 cm⁻¹ resolution |
| Data Sampling Interval | 2 cm⁻¹ |
| Sampling Modes | Diffuse Reflectance, Transmission, Diffuse Transmission, Fiber-Optic Probe |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MultiRAM |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 3600 – 50 cm⁻¹ |
| Spectral Resolution | < 0.5 cm⁻¹ |
| Detector Options | Room-temperature InGaAs (1× or 2×), Liquid-nitrogen-cooled Ge photodiode |
| Laser Source | Software-controlled Nd:YAG, 1064 nm |
| Interferometer | RockSolid™ permanent-alignment, gold-coated optics |
| Beam Splitter | Broadband quartz |
| Sample Chamber | Triple-side access, switchable 90° scattering geometry, defocusing optics |
| Standard Accessories | Motorized sample stage, integrated white-light source for response calibration, dual fiber-coupling ports, polarization control module |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Nanophoton RAMANtouch |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |
| Detection Method | Line-illumination + 2D CCD Acquisition |
| Imaging Speed | Full-spectrum mapping of >100,000 pixels in minutes |
| Automation Level | Fully motorized stage, autofocus, auto-alignment, auto-calibration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanophoton RAMANwalk |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm in X and Y |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | oIR3-s |
| Instrument Type | Laboratory-Based Fourier Transform Infrared Spectrometer |
| Wavenumber Range | 900–3600 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Acquisition Speed | 10 s per spectrum |
| Signal-to-Noise Ratio | 200:1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–785 nm (dual optical paths: 130–785 nm total coverage) |
| Number of Channels | 128 |
| Optical System | MultiVision™ with argon-purged vacuum UV path |
| Temperature Compensation | AAC™ Active Ambient Compensation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Desktop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Pixel Count / Pixel Size | 3880 pixels per CCD chip |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q6 NEWTON |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Pixel Count / Pixel Size | 3880 pixels per single detector block |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Argon Consumption | 2–4 L/min (during analysis) |
| Detector Configuration | Single PMT with 3880 discrete detection channels |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 110–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 110–800 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | RAM II |
| Instrument Type | FT-Raman Module |
| Spectral Range | 3600 – 50 cm⁻¹ (Stokes shift) |
| Compatibility | INVENIO, VERTEX 70v, VERTEX 80v, VERTEX 80 vacuum FTIR spectrometers |
| Laser Source | Software-controlled Nd:YAG (1064 nm) |
| Detector Options | Room-temperature InGaAs (1× or 2×), proprietary liquid-nitrogen-cooled Ge photodiode |
| Cooling Duration | Up to 7 days per fill |
| Optical Coupling | Dual fiber-optic ports, 90° scattering geometry, defocusing optics |
| Sample Stage | Motorized XYZ stage with focus control |
| Calibration Source | Integrated spectral response correction lamp |
| Software Platform | OPUS v8.x or later with automated FT-Raman/FT-IR switching |