Spectroscopy Instruments
Filter
Showing 391–420 of 2607 results
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Lightwave 3+ |
| Optical Design | Single-beam |
| Detector Type | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 3 nm |
| Stray Light | <0.5% T at 340 nm |
| Display | 5-inch color touchscreen |
| Absorbance Range | –0.3 to 2.5 A |
| Cuvette Compatibility | Up to 40 mm pathlength |
| Automation | Motorized wavelength scanning |
| Light Source | Xenon flash lamp |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultrospec 30 |
| Pricing | Available Upon Request |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Model | Ultrospec 35c |
| Wavelength Options | 450, 500, 520, 540, 600, 640 nm |
| Display | 4.3-inch color touchscreen |
| Data Export | CSV format to USB drive |
| Power Options | Internal rechargeable battery or AC adapter |
| Sample Format | Cuvette- or test-tube-based liquid samples |
| Measurement Modes | Absorbance and Transmittance |
| Kinetics Capability | Basic time-resolved absorbance monitoring |
| Compliance | Designed for GLP-supporting workflows in academic, industrial, and field laboratories |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Ultrospec 7500 |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | <2 nm |
| Stray Light | <0.05 %T at 220 nm (NaI) or 340 nm (NaNO₂), <0.10 %T at 380 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning |
| Compliance | Optional 21 CFR Part 11 Software Module (Resolution™) |
| Brand | BioTools |
|---|---|
| Origin | USA |
| Model | ChiralIR-2X |
| Instrument Type | Vibrational Circular Dichroism (VCD) Spectrometer |
| Spectral Range | 4000–850 cm⁻¹ (standard), optional extension to 10,000 cm⁻¹ (NIR) |
| Baseline Drift | < 2 × 10⁻⁵ AU |
| Signal-to-Noise Ratio | >3.6× improvement over single-source systems |
| Detector Continuous Operation | 30–48 hours |
| Optical Path | Fully automated alignment and calibration |
| Data Acquisition | Digital signal processing (no lock-in amplifiers or analog filtering required) |
| Sample Stage | SyncRoCell™ rotating sample cell platform |
| DualPEM™ capability | Optional upgrade for solid-sample VCD correction |
| Brand | BioTools |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ChiralRAMAN-2X |
| Instrument Type | Microscopic Confocal Raman Spectrometer |
| Spectral Range | 100–2000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1×1 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-UV254 |
| Wavelength Range | 248–262 nm |
| Peak Wavelength | 254 nm |
| Measurement Range | 1 µW/cm² to 39.99 mW/cm² |
| Resolution | 1 µW/cm² |
| Spectral Band Rejection (Out-of-Band) | <0.1% |
| Accuracy | ±8% + 2 digits |
| Linearity Error | ±1% |
| Range Switching Error | ±1% |
| Sampling Rate | 2 Hz |
| Display | 3¾-digit LCD with backlight |
| Overload Indication | "OL" |
| Operating Temp./RH | 0–45 °C / 0–70% RH |
| Storage Temp./RH | −10–50 °C / 0–80% RH |
| Power | Three 3 V CR2032 coin cells |
| Battery Life | ~300 h (backlight off) |
| Auto Power-Off Delay | 5 min |
| Host Dimensions | 160 × 78 × 34 mm |
| Probe Dimensions | Ø50 × 40 mm |
| Telescopic Handle | 12 cm (single-stage), 24 cm (dual-stage) |
| Probe Cable Length | 1 m (including handle) |
| Weight | ~405 g (with batteries and probe) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BlueSpecCube |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Spectral Range | 300–1000 nm |
| Detector | Back-Illuminated CMOS Linear Array |
| Optical Resolution | < 4.5 nm (FWHM, with 50 µm slit) |
| Sensitivity | 5 × 10¹⁶ counts/W·s @ 300 nm |
| Signal-to-Noise Ratio | 3000:1 (full well, 1 s integration) |
| Dynamic Range | 10,000:1 (typical, single acquisition) |
| Stray Light | < 0.1 % (600 nm, relative to peak) |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9W |
| Instrument Architecture | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.5% |
| Objective Magnifications | 20× (NA 0.26), 23× (NA 0.30), 26× (NA 0.34), 29× (NA 0.38) |
| Projection Magnification | 21× |
| Illumination Source | 12 V / 50 W Tungsten-Halogen Lamp |
| Slit Width Adjustment | 0–3 mm (graduated to 0.01 mm) |
| Height Adjustment | 0–20 mm (graduated to 2 mm) |
| Stage Travel | Longitudinal 0–90 mm (1 mm scale), Transverse 0–220 mm (coarse) + 0–25 mm (fine, 0.01 mm resolution) |
| Selenium Photocell Active Area | Ø25 mm |
| Sensitivity | 400–500 µA/lm |
| Lifetime | ≥500 h |
| Galvanometer Sensitivity | 2.5 × 10⁻⁹ A/mm/m |
| Oscillation Period | 1 s |
| Net Weight | 50 kg |
| Dimensions (L × W × H) | 1500 × 900 × 800 mm |
| Key | Wavelength Range: 1310 nm / C-band (1530–1565 nm) / L-band (1570–1610 nm) |
|---|---|
| Insertion Loss | <0.9 dB |
| Dynamic Range | >20 dB |
| Polarization-Dependent Loss (PDL) | ≤0.5 dB (typ. 0.3 dB) @1550 nm, 15 dB attenuation |
| Spectral Flatness | ≤0.5 dB max (typ. 0.3 dB) @15 dB attenuation |
| Response Time (full range) | <30 µs |
| Input Power Handling | <500 mW |
| Return Loss | >55 dB |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −40–85 °C |
| Package Dimensions | 26 × 10 × 9 mm³ |
| Capacitance | 500 pF typ. |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | China |
| Model | BAF-2000 |
| Price | Upon Request |
| Detectable Elements | As, Se, Sn, Sb, Hg, Cd, Te, Bi, Ge, Zn, Au |
| Elemental Speciation Capability (Upgraded) | As, Hg, Se, Sb |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAF-3000 |
| Detection Elements | As, Hg, Se, Sb, Bi, Pb, Te, Ge, Cd, Sn, Zn, Au |
| Channel Configuration | Triple-channel simultaneous detection |
| Speciation Capability | As, Hg, Se, Sb (post-upgrade) |
| Optical Design | Optimized low-background fluorescence path with 30% sensitivity enhancement vs. conventional configurations |
| Mercury Lamp System | Auto-ignition and real-time drift compensation |
| Light Source Alignment | Motorized auto-focusing |
| Brand | BoDe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BAF-4000 |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Sn, Sb, Hg, Cd, Te, Bi, Ge, Zn, Au |
| RSD (Relative Standard Deviation) | ≤0.7% |
| Linear Dynamic Range | ≥3 orders of magnitude |
| Detection Limits | As, Sb, Se, Hg, Sn ≤ 0.01 µg/L |
| PMT Wavelength Range | Standard 160–320 nm (customizable upon request) |
| Atomizer Temperature Control Range | Standard ambient temperature |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSA-100A |
| Pricing | Upon Request |
| Target Analytes | Speciated trace heavy metals — including As(III), As(V), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Producer |
| Country of Origin | Domestic (China) |
| Model | BSA-100B |
| Pricing | Upon Request |
| Target Analytes | Speciated trace heavy metals — including As(III), As(V), MMA(V), DMA(V), AsB, AsC, p-ASA, Roxarsone, Hg²⁺, MetHg, EtHg, PhHg, Se(IV), Se(VI), SeCys, SeMeCys, SeMet, Sb(III), Sb(V), and >12 additional organometallic species |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSA-100C |
| Pricing | Upon Request |
| Target Analytes | Speciated trace heavy metals — including arsenic species (As(III), As(V), MMA, DMA, AsB, AsC, p-ASA, Roxarsone), mercury species (Hg²⁺, MeHg, EtHg, PhHg), selenium species (Se(IV), Se(VI), SeCys, SeMeCys, SeMet), antimony species (Sb(III), Sb(V)) |
| Detection Principle | Post-column hydride generation coupled with atomic fluorescence detection (HG-AFS) after LC separation |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Instrument Type | Handheld LIBS Analyzer |
| Model | LIBS 800 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (Software Mode), ISO/IEC 17025–compatible workflow support |
| Laser Class | 3B (IEC 60825-1:2014) |
| Weight | 1.65 kg |
| Spectral Range | 190–950 nm |
| Optical Resolution | ≤0.1 nm (FWHM) |
| Detection Limits | Sub-ppm to % level (matrix-dependent) |
| Analysis Time | <2 s per measurement |
| Sample Interaction | Non-contact, micro-destructive (crater diameter <100 µm) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q8 MAGELLAN |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 110–800 nm |
| Number of Channels | 128 |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | RGF-7700 |
| Instrument Type | Multi-Channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Detectable Elements | As, Hg, Se, Pb, Ge, Sn, Sb, Bi, Cd, Te, Zn, Au |
| Relative Standard Deviation (RSD) | < 0.8% |
| Linear Dynamic Range | > 3 orders of magnitude |
| Detection Limits | As, Se, Pb, Bi, Sb, Te, Sn < 0.01 µg/L |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SuperFlux™ |
| Instrument Type | Online Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Safety Features | Integrated laser fiber break detection and hardware interlock |
| Compliance | FDA 21 CFR Part 11 ready |
| Enclosure Rating | Suitable for hazardous (explosion-proof) areas |
| Form Factor | Standalone, compact benchtop unit |
| Brand | Brookman |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PB7220-2000-T |
| Pricing | Available Upon Request |
| System Bandwidth | 1.7–2.1 THz |
| Spectral Resolution | 0.1–5 GHz |
| Dynamic Range | 70 dB (at 100 GHz), 45 dB (at 1 THz), 40 dB (at 2 THz) |
| THz Beam Diameter (FWHM @ 0.5 THz) | 12 mm |
| Optical Path Length | 25 cm |
| Tuning Speed | 10 GHz/s |
| Electronic Chopper Frequency | 6 kHz |
| Dual-Channel Operation | Transmission + Reflection/Scattering Simultaneously |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | AgriCheck |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating-based Scanning Monochromator |
| Wavelength Range | 730–1100 nm |
| Wavelength Resolution | 0.5 nm |
| Scan Speed | 45 scans per analysis |
| Data Sampling Interval | 3 s |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP |
| Sample Capacity | ~650 mL (whole grains) |
| Analysis Time | ~45 s |
| Sample Handling | Automated feeder with 16 independent sub-sampling positions |
| Dimensions | 385 × 420 × 385 mm |
| Weight | 21 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 45 W |
| Environmental Protection | Dust- and moisture-resistant enclosure |
| Interface Options | USB, Ethernet, Parallel Port |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | AgriCheck Plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based Scanning Monochromator (Dual-Beam) |
| Wavelength Range | 730–1100 nm and 1400–2500 nm |
| Spectral Resolution | 0.5 nm |
| Scan Time | ~45 s |
| Sampling Modes | Transmission (for whole grains) and Diffuse Reflectance (for ground/powdered samples) |
| Chemometrics Software | RIMP |
| Dimensions | 385 × 420 × 385 mm |
| Weight | 21 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 45 W |
| Sample Capacity | 650 mL (whole grain), 60 mL (ground) |
| Auto-sampler | 16-position independent sub-sample measurement |
| Rotating Sample Cup | Integrated for homogenized samples |
| Environmental Protection | IP54-rated dust- and moisture-resistant enclosure |
| Interface Ports | USB, Ethernet, Parallel |
| Optional Accessories | Built-in bulk density module, temperature probe, thermal receipt printer, barcode scanner, external keyboard/mouse |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | AgriCheck XL |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based Scanning Monochromator |
| Wavelength Range | 730–1100 nm |
| Wavelength Resolution | 0.5 nm |
| Scan Time | ~45 s |
| Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP |
| Sample Handling | Rotating Sample Tray & Auto-sampling (16 sub-samples) |
| Sample Volume | 30–100 mL (small-batch) or ~650 mL (standard) |
| Dimensions | 385 × 420 × 385 mm |
| Weight | 21 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 45 W |
| Environmental Protection | Dust- and Moisture-Resistant |
| Compliance | CE, RoHS |
| Optional Accessories | Integrated Grain Density Module, Temperature Probe, Thermal Receipt Printer, Barcode Scanner, External Keyboard/Mouse |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | FoodCheck |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating-based Scanning Monochromator |
| Wavelength Range | 730–1100 nm or 1400–2500 nm |
| Spectral Resolution | 0.5 nm |
| Scan Time | ~50 s |
| Sampling Mode | Transmission or Optional Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Enclosure Rating | IP65 |
| Dimensions | 375 × 460 × 370 mm |
| Weight | 28 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 33 W |
| Sample Volume | ~60 mL |
| Sample Handling | Manual Loading with Rotating Sample Tray |
| Interface | USB, Ethernet, Parallel Port |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | InfraCheck |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 730–1100 nm (primary) / 1400–2500 nm (extended, per spec sheet) |
| Wavelength Resolution | 0.5 nm |
| Sampling Interval | 1 s |
| Measurement Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | RIMP |
| Dimensions | 345 × 385 × 200 mm |
| Weight | 16 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 30 W |
| Sample Volume | ~60 mL |
| Analysis Time | ~50 s |
| Sample Handling | Manual loading with rotating sample carousel |
| Interfaces | USB, Ethernet, Parallel Port |
| Environmental Protection | Dust- and moisture-resistant enclosure |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | InfraScan |
| Instrument Type | Laboratory |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 730–1100 nm (standard), optional 380–1100 nm |
| Scan Speed | 45 spectra/sec |
| Data Sampling Interval | 1 second |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | RIMP |
| Dimensions | 370 × 370 × 460 mm |
| Weight | 28 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 45 W |
| Environmental Protection | Dust- and moisture-resistant |
| Interface | USB, Ethernet, Parallel Port |
| Wavelength Resolution | 0.5 nm (standard) |
| Optional High-Resolution Models | Omega 10 (0.2 nm), Omega 20 (0.1 nm) |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | MultiCheck |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based, non-scanning array detector |
| Wavelength Range | 730–1100 nm and 1400–2500 nm |
| Wavelength Resolution | 0.5 nm |
| Measurement Modes | Transmission and Diffuse Reflectance |
| Sample Throughput | ~50 s per analysis |
| Standard Pathlength | 12 mm cuvette (optional: 3–30 mm) |
| Sample Volume | 750 mL (whole grains), 60 mL (ground materials) |
| Detector | Linear CCD/CMOS array |
| Software | RIMP Chemometrics Suite |
| Compliance | Designed for GLP-compliant workflows |
| Dimensions | 585 × 420 × 480 mm |
| Weight | 31 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 65 W |
| Brand | Bruins |
|---|---|
| Origin | Germany |
| Model | Omega 40 |
| Instrument Type | Online NIR Analyzer |
| Optical Principle | Grating-based Scanning Monochromator |
| Wavelength Range | 730–1100 nm or 1400–2500 nm |
| Wavelength Resolution | 0.5 nm |
| Scan Speed | <1 s per spectrum |
| Sampling Mode | Transmission or Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Channel Capacity | Up to 8 simultaneous measurement channels |
| Dimensions | 985 × 420 × 300 mm |
| Weight | 45 kg |
| Power Supply | 220–240 V / 50 Hz |
| Power Consumption | 80 W |
| IP Rating | Dust- and moisture-resistant enclosure |
| Interface | USB, Ethernet, Parallel Port |