Spectroscopy Instruments
Filter
Showing 361–390 of 2603 results
| Brand | Beiyu Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SGMA-730 |
| Pricing | Upon Request |
| Brand | Belec |
|---|---|
| Origin | Germany |
| Model | Belec Compact-Port |
| Instrument Type | Portable / Mobile |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Grooves | 3600 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 18 |
| Weight | 17 kg |
| Optional Spark Probes | Argon “Special” Probe, Argon “Dedicated” Probe, Air Probe |
| Multi-Matrix Capability | Up to 6 base materials with 36 total elemental channels |
| Software | Belec proprietary analysis software (10+ language options, including full Chinese UI) |
| Hybrid Configuration | Compatible with external spark stand for benchtop operation |
| Brand | Belec |
|---|---|
| Origin | Germany |
| Model | Belec Lab 3000s |
| Instrument Type | Fixed-position (compact benchtop) |
| Excitation Source | Spark discharge |
| Detector | CCD (Charge-Coupled Device) |
| Focal Length | 300 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 175–430 nm |
| Number of Analytical Channels | 24 |
| Elemental Coverage | Includes C, P, S, N (light elements) |
| Sample Form Compatibility | Solid metallic samples, wire ≥0.5 mm diameter, tubes, rods, and flat solids |
| Dimensions (W×D×H) | 440 × 415 × 579 mm |
| Brand | Belec |
|---|---|
| Origin | Germany |
| Model | Belec Vario Lab |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–430 nm |
| Number of Channels | 108 |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 37.5–3000 cm⁻¹ |
| Spectral Resolution | ≤7 cm⁻¹ |
| Spatial Resolution | ≤1 µm (lateral, diffraction-limited) |
| Excitation Wavelength | 532 ±1 nm |
| Spectral Reproducibility | ≤±0.5 cm⁻¹ (over 8-hour continuous operation) |
| Detector | Back-illuminated, deep-cooled CCD (−60 °C operating temperature) |
| Laser Safety Class | IEC 60825-1 Class 1 compliant |
| Data Acquisition | Software-controlled, automated alignment and acquisition |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 50–5000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | Lateral (XY) ≤500 nm @532 nm (100× dry objective, pinhole ≥50 μm) |
| Wavenumber Repeatability | <0.05 cm⁻¹ |
| Excitation Wavelengths | 532 nm (50 mW), 638 nm (50 mW), 785 nm (100 mW) |
| Detector | Back-illuminated TE-cooled CCD (−60 °C), QE >90% peak |
| Grating Options | 600, 1200, 1800 grooves/mm (software-controlled auto-switching) |
| Microscope | Research-grade upright microscope with LED epi-illumination |
| Stage | Motorized XYZ stage (60 × 55 × 50 mm travel) |
| Objectives | 10×, 50×, 100× dry |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | < 1 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | > 45,000:1 (at 4 cm⁻¹, 1 min scan) |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Beam Splitter | Hygroscopic-resistant ZnSe |
| Detector | Standard DLaTGS |
| Interferometer | High-stability立体角镜 (Cube Corner) Interferometer |
| Laser | Solid-state He–Ne Reference Laser |
| Optical Mirrors | Gold-coated, >95% reflectivity in mid-IR |
| Enclosure | Hermetically sealed, desiccant-integrated optical bench |
| Aperture | External adjustable precision iris |
| Dimensions | 685 × 415 × 223 mm |
| Weight | 25 kg |
| Power | 100–240 VAC, 50–60 Hz, ≤100 W |
| Data Interface | Gigabit Ethernet |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | Lambda-22 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 320–1100 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T at 220 nm and 360 nm |
| Automation Level | Automatic Wavelength Scanning |
| Display | Dot-Matrix LCD |
| Sample Compartment | Accommodates Cuvettes from 5 mm to 100 mm Pathlength |
| Lamp Type | Long-Life Deuterium Lamp (D₂) with Flange-Mounted Base |
| Data Storage | Internal Non-Volatile Memory with Power-Fail Protection |
| Connectivity | RS-232 or USB (Optional) for PC Integration |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Lambda-220 |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.1% T at 220 nm and 360 nm |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | Lambda-260A |
| Instrument Architecture | Single-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Lamda-260RN / Lamda-260DN |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.8 nm (Lamda-260RN), 2.0 nm (Lamda-260DN) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Origin | Domestic (China) |
| Model | NanoUV |
| Wavelength Range | 200–850 nm |
| Wavelength Accuracy | ±1.0 nm (at 302 nm, 25°C) |
| Absorbance Linearity | 0–1.5 A (cuvette mode) |
| Absorbance Accuracy | ±3% at 0.97 A (25°C, reported in Abs/mm) |
| Detection Modes | Nano-volume (1–2 µL) and Cuvette (10 mm pathlength) |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Model | OpenRam FIB6500 |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | ≤2 cm⁻¹ |
| Spatial Resolution | 500 nm @ 532 nm excitation with 100× objective |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | Better than ±1% |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PTRam 785 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ (customizable) |
| Spectral Resolution | ≤12 cm⁻¹ across full range |
| Spatial Resolution | 1 mm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Excitation Wavelength | 785 ± 0.5 nm |
| Laser Linewidth | < 0.08 nm |
| Laser Power | 0–500 mW (software-adjustable) |
| Integration Time | 8 ms – 65 s |
| Detector | Back-illuminated CCD |
| Slit Width | 25 µm |
| Optical Path | Fiber-coupled, confocal design |
| Dimensions | 180 × 95 × 38 mm |
| Weight | < 700 g |
| IP Rating | IP65 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 5–80 % RH |
| Connectivity | Wi-Fi, Bluetooth 5.0, GPS |
| Display | 5.5″ capacitive touchscreen (720 × 1280) |
| Camera | 8 MP autofocus |
| Power Supply | 5 V / 2 A via Micro-USB |
| Laser Lifetime | ≥10,000 hours |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 532 nm (785 nm optional) |
| Spectral Range | 100–3000 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | XY = 0.08 µm, Z = 0.05 µm |
| Minimum Wavenumber | 80 cm⁻¹ |
| Spectral Repeatability | < 0.01 nm/°C |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TeachRam FIB Manual |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelength | 785 nm (532 nm optional) |
| Spectral Range | 100–3000 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 50 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤1 cm⁻¹ |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Resolution | Better than 1.0 cm⁻¹ |
| Signal-to-Noise Ratio | >15,000:1 (4 cm⁻¹, 1 min scan) / Optional >30,000:1 |
| Wavenumber Accuracy | Better than ±0.01 cm⁻¹ |
| Interferometer | DSP-Controlled Electromagnetic Michelson Interferometer |
| Beam Splitter Options | KBr/Ge, ZnSe, CaF₂ |
| Detector | DLATGS with Anti-Humidity Coating |
| Light Source | Long-Life Ceramic IR Source (Imported) |
| Data Interface | USB 2.0 (USB 3.0 Compatible) |
| A/D Conversion | 24-bit, 500 kHz |
| Brand | Betop Scientific |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WPP 2000 |
| Dispersion | 0.45 nm/mm |
| Focal Length | 1800 mm |
| Optical Configuration | Ebert-Fastie vertical symmetric design |
| Automation | Integrated control box and counter for full automated spectral acquisition and central wavelength readout |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | Micro Drop |
| Wavelength Range | 185–910 nm |
| Minimum Sample Volume | 0.5 µL |
| Pathlength Adjustment | 0.05–1 mm (automated) |
| dsDNA Detection Range | 2–15,000 ng/µL |
| Absorbance Accuracy | ±3% at 0.65 Abs (350 nm) |
| Absorbance Precision | 0.002 Abs (1 mm pathlength) |
| Spectral Resolution | <1.8 nm FWHM (Hg 253.7 nm) |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0.02–300 (equivalent to 10 mm pathlength) |
| Cuvette Mode Temperature Control | 37 ± 0.5 °C |
| Cuvette Pathlength Options | 1, 2, 5, 10 mm |
| Wireless Connectivity | Wi-Fi enabled |
| Dimensions | 220 × 135 × 180 mm |
| Weight | 2.1 kg |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | Microdrop Plus |
| Wavelength Range | 185–910 nm |
| Sample Volume (Capillary Mode) | 0.5–2 µL |
| Sample Volume (Cuvette Mode) | Standard 10 mm pathlength cuvettes |
| Detection Sensor | 2048-pixel linear CCD array |
| Display | 7-inch high-resolution color touchscreen |
| Internal Storage | High-capacity embedded memory |
| Connectivity | USB and Wi-Fi |
| Temperature Control & Stirring | Available in cuvette mode |
| Optical Path Adjustment | Automatic variable-pathlength technology |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Bio-logic |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EKKO |
| Price Range | USD 68,000 – 136,000 (est.) |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Wavelength Range | 185–850 nm |
| Spectral Bandwidth | 1 nm (full range) |
| Noise Level | ≤ 0.05 mdeg |
| Plate Formats | Standard 96-well microplates (optional 384-well support) |
| Modulation Frequency | 50 kHz |
| Single-Wavelength Throughput | ~2 min per 96-well plate |
| Multi-Wavelength Scan (e.g., 210–350 nm, 5 nm step) | ~30 sec per well (~50 min total) |
| Full-Spectrum Scan (185–850 nm, 1 nm step) | ~11 min per well (~18 h total) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MOS-450 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Light Sources | 150 W Xenon Lamp + 150 W Mercury-Xenon Lamp |
| Wavelength Range | 165–900 nm |
| Wavelength Accuracy | ±0.1 nm (165–900 nm) |
| Optical System | Dual Grating (1200 grooves/mm) |
| Stray Light | < 2 × 10⁻⁴ % (at 200 nm) |
| Noise Level (CD) | 0.01 mdeg |
| Baseline Stability | < 0.01 mdeg/hr |
| Data Acquisition Rate | 10 µs to 1000 s per point |
| Stopped-Flow Unit | Triple-/Quadruple-Channel Mixing, Independent Stepper-Motor Control per Channel |
| Minimum Injection Volume | 10 µL |
| Flow Rate per Channel | 0.01–1.0 mL/s |
| Mixing Ratio Range | Continuously Adjustable from 1:1 to 1:100 |
| Minimum Dead Time | 0.25 ms (with micro-volume detection cell) |
| Expandable Modules | Cryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Auto-Titration, In-Situ Micro-Conductivity Detection |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MOS-500 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Light Sources | 150 W Xenon Lamp + 150 W Mercury-Xenon Lamp |
| Detection Modes | CD, UV-Vis Absorption, Fluorescence CD (FCD), Linear Dichroism (LD), Fluorescence Anisotropy |
| Wavelength Range | 163–950 nm (extendable to 1250 nm) |
| Wavelength Accuracy | ±0.1 nm (163–1250 nm) |
| Optical System | Dual Grating Monochromator |
| Stray Light | <2 × 10⁻⁶ at 200 nm |
| Baseline Stability | 0.007 mdeg/hr |
| Maximum Scan Speed | 12,000 nm/min |
| Solid Sample Capability | Integrated Integrating Sphere for Diffuse Reflectance |
| Stopped-Flow Unit | Triple- or Quadruple-Channel Mixing with Independent Stepper-Motor Control |
| Minimum Injection Volume | 10 µL |
| Flow Rate Range | 0.01–40 mL/s |
| Mixing Ratio Range | Continuously Adjustable from 1:1 to 1:100 |
| Mixer Type | Spherical High-Efficiency Mixing Cell |
| Dead Time | 0.2 ms (with Microcell Accessory) |
| Expandable Modules | Cryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Automated Titration, Microconductivity Detection |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SFM-100+MOS-LED |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 180–820 nm |
| Wavelength Accuracy | ±0.1 nm |
| Spectral Bandwidth | 0–16 nm (adjustable) |
| Stray Light | ≤2 ppm |
| Dead Time | 5 ms (motor-driven), 8 ms (manual) |
| Sample Consumption per Experiment | 30 µL |
| Mixing Chamber Dead Volume | 20 µL |
| Mixing Ratio | Variable |
| Control Interface | USB |
| Detection Modes | Standard Absorbance (default), optional Fluorescence and Dual-Absorbance modes |
| Software | Spec-Lab v5.x |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop DUO+ |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Pathlength | 10 mm |
| Sample Volume (min) | 0.5 µL |
| Fixed Microvolume Pathlength | 0.5 mm ± 5 µm |
| Absorbance Range | –0.3 to 2.5 A |
| Stray Light | <0.5% T at 220 nm & 340 nm (NaNO₂) |
| Detector | 1024-pixel CCD array |
| Light Source | Pulsed Xenon Lamp (3-year warranty) |
| Display | 7-inch capacitive color touchscreen |
| Dimensions | 410 × 280 × 190 mm |
| Weight | 3.55 kg |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BioDrop μLite+ |
| Price | Upon Request |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Biowave 3 |
| Optical System | Pseudo-double-beam |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Spectral Bandwidth | 3 nm or 5 nm (selectable) |
| Stray Light | ≤0.5% at 220 nm and 340 nm |
| Absorbance Range | –0.3 to 2.5 A |
| Light Source | Xenon flash lamp |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Biowave 3+ |
| Optical Design | Single-beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 3 nm |
| Stray Light | <0.5% T at 340 nm |
| Absorbance Range | –0.3 to 2.5 A |
| Built-in Applications | Nucleic Acid Quantification, Protein Assays (UV280, Bradford, Lowry, Biuret), Fluorescent Dye Labeling Efficiency, OD600 Cell Density, Melting Temperature (Tm) Analysis |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Lightwave 3 |
| Optical Design | Single-beam with diode array detection |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 5 nm (3 nm optional) |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.5% at 220 nm and 340 nm |
| Detector | CCD array |
| Light Source | Long-life xenon lamp |
| Absorbance Range | –0.3 to 2.5 A |
| Measurement Modes | Scanning, Fixed-wavelength, Kinetics, Concentration (factor, single-point, multi-standard calibration, multi-wavelength ratio) |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Lightwave 3+ |
| Optical Design | Single-beam |
| Detector Type | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 3 nm |
| Stray Light | <0.5% T at 340 nm |
| Display | 5-inch color touchscreen |
| Absorbance Range | –0.3 to 2.5 A |
| Cuvette Compatibility | Up to 40 mm pathlength |
| Automation | Motorized wavelength scanning |
| Light Source | Xenon flash lamp |