Synthesizer
Filter
Showing 31–52 of 52 results
| Brand | Protein Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Life Science Instrument |
| Model | PurePep® Chorus |
| Amino Acid Delivery | Fully Automated |
| Reagent Delivery | Fully Automated |
| Synthesis Scale per Reactor | 0.005–1.0 mmol |
| Total Capacity (6RV Configuration) | 6.0 mmol |
| Reactor Configurations | 2-, 4-, or 6-Reactor Vessel (RV) modular system, field-upgradable |
| Reactor Vessel Options | Disposable polypropylene (10 mL, 45 mL) or borosilicate glass (10 mL, 25 mL, 40 mL) |
| Brand | Protein Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Symphony® X |
| Amino Acid Delivery | Fully Automated |
| Reagent Delivery | Fully Automated |
| Synthesis Scale | 0.005–24 mmol per reactor (up to ~2 g resin per RV) |
| Single-Shot Dispense Volume | ≥0.5 mL or ≥1 mL per delivery |
| Reactor Count | 24 independent reactors (12 with optional pre-activation capability) |
| Reactor Vessel Capacity | Disposable polypropylene: 10 mL, 45 mL |
| Borosilicate glass | 10 mL, 40 mL |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI286 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per reactor |
| Reactor Count | 1–3 (configurable) |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.01 mL |
| Coupling Efficiency | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/s |
| Mixing Mode | Stirring-Free Reactor Inversion (180° mechanical oscillation) |
| Mixing Speed | 0–30 rpm, continuously adjustable |
| Construction Material | 304 stainless steel |
| Power Supply | 110/220 V, 50/60 Hz |
| Host Power | 1 kW |
| Weight | 100–150 kg |
| Dimensions (W×D×H) | 113×52×72 cm (1-channel) |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI314 |
| Synthesis Scale | 2.5–20 mmol per channel |
| Reactor Count | 3 or 6 |
| Reactor Volume Options | 0.5 L / 1 L / 2 L |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| Mixing Mode | Dual-axis reactor inversion (stirrer-free) |
| Power Supply | 110/220 V, 50/60 Hz |
| Construction Material | 304 stainless steel frame, borosilicate glass solvent reservoirs (0.5–5 L), 316L stainless steel large-capacity tanks (10–30 L) |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI319 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per channel |
| Reactor Count | 1 |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/sec |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI386 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.25–3 mmol per channel |
| Reactor Count | 30 |
| Reactor Volumes | 50 mL, 100 mL, 200 mL (jacketed) |
| Syringe Pump Accuracy | ±0.01 mL |
| Coupling Efficiency / Crude Purity | ≥99.5% |
| Solvent Flow Rate | 2–4 mL/s |
| Mixing Mechanism | Stirring-free reactor inversion (180° mechanical oscillation) |
| Inversion Speed | 0–30 rpm, continuously adjustable |
| Solvent Reservoirs | 8 units |
| Power Supply | 110/220 V, 50/60 Hz |
| Enclosure Material | 304 stainless steel |
| Unit Weight | 100–150 kg |
| Dimensions (W×D×H) | 113 × 58 × 72 cm |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | PSI413 |
| Synthesis Scale | 2.5–20 mmol per channel |
| Reactor Configuration | 1 or 2 reactors |
| Reactor Volumes | 0.5 L, 1 L, 2 L (jacketed) |
| Amino Acid & Reagent Addition | Manual |
| Syringe Pump Accuracy | ±0.1 mL |
| Solvent Flow Rate | 200 mL/min |
| Mixing Mechanism | Reactor Inversion (stirrer-free) |
| Coupling Efficiency | ≥99.5% |
| Temperature Control | Water Bath |
| Agitation Speed | 0–25 rpm (infinitely adjustable) |
| Solvent Reservoirs | 4 |
| Power Supply | 220 V, 50/60 Hz, 1 kW |
| Inert Atmosphere | N₂ or Ar throughout synthesis |
| Maximum Peptide Length | >100 residues |
| Construction Material | 304 Stainless Steel |
| Compliance | Designed for GLP-compliant peptide process development and scale-up |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI419 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Channel | 2.5–20 mmol |
| Number of Reaction Vessels | 2 |
| Vessel Capacities | 0.5 L, 1 L, 2 L (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI486 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 2.5–20 mmol |
| Reactor Count | 1 |
| Reactor Volumes | 0.5 L, 1 L, 2 L (jacketed) |
| Syringe Pump Accuracy | ±0.1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 200 mL/min |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI586 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 5–50 / 10–100 / 25–200 mmol |
| Reactor Count | 1 |
| Reactor Volume Options | 1L & 5L / 2L & 10L / 5L & 20L |
| Syringe Pump Precision | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 1–2 L/min |
| Brand | PSI |
|---|---|
| Origin | USA |
| Model | DL-PSI686 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.15–1 mmol and 1–3 mmol |
| Reactor Quantity | 1 |
| Reactor Volume Options | 30 L / 50 L / 100 L / 200 L |
| Syringe Pump Precision | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Solvent Flow Rate | 10–20 L/min |
| Construction Material | 304 Stainless Steel |
| Reactor Drive Power | 1.8–3.5 kW |
| Reactor Dimensions (L×W×H) | 158–185 cm × 70–95 cm × 125–165 cm |
| Cabinet Dimensions (L×W×H) | 145–165 cm × 90–120 cm × 185–215 cm |
| Mixing Mechanism | 180° bidirectional reactor inversion (impeller-free) |
| Solvent Inlet Channels | 3 or 5 (tubing-based) |
| Waste Discharge Ports | 3 (categorized, tubing-based) |
| Recycle Loops | 2 (tubing-based) |
| Stirring Speed Range | 0–15 rpm (infinitely variable) |
| Brand | PSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DL-PSI786 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 2–3 mol |
| Reactor Quantity | 1 |
| Reactor Volume Range | 200 L / 300 L |
| Syringe Pump Accuracy | ±1 mL |
| Synthesis Purity | ≥99.5% |
| Flow Rate | 10–20 L/min |
| Brand | PSI Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EX870B |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Audit Trail | Yes |
| Synthesis Scale | Configurable (0.1–5 mmol typical batch range) |
| Reactor Count | 1 |
| Reactor Type | Hydraulic-actuated, jacketed stirred-tank reactor with integrated resin handling |
| Brand | PSISCIENTIFIC |
|---|---|
| Origin | USA |
| Model | E860 / EX860 |
| Synthesis Scale | 62.5–250 mmol |
| Reaction Vessel Volume | 5–20 L (configurable) |
| Heating | Optional |
| Coupling Efficiency | >99% |
| Stirring Mechanism | 180° Vertical Inversion |
| Compliance | FDA 21 CFR Part 11, cGMP (US & China), ATEX/IECEx for EX860 |
| Activation Methods | HOBt/DIC, DCC, HBTU, HATU, PyBOP, OxymaPure, etc. |
| Amino Acid Reservoir Capacity | 250 mL – 2 L |
| Stirring Speed | 0–100 rpm (infinitely variable) |
| Dimensions | 1800 × 1020 × 810 mm (W×D×H) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Model | A36228 |
| Format | Spin-column-based silica-membrane purification |
| Endotoxin Level | <1 EU/µg |
| Yield | Up to 1.5 mg high-purity plasmid DNA per prep |
| Processing Time | ~30 min |
| Required Equipment | Vacuum manifold (e.g., FastVac) or centrifuge (with optional adapter) |
| Buffer System | Colorimetric lysis and neutralization buffers |
| Intended Use | Transfection-grade plasmid isolation from E. coli cultures (up to 250 mL) |
| Brand | Hanking |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | PurePep® Sonata®+ |
| Amino Acid Delivery | Fully Automated |
| Reagent Delivery | Fully Automated |
| Synthesis Scale | 1–200 mmol |
| Reactor Quantity | 1 |
| Reactor Volume Options | 200 mL, 500 mL, 1.2 L, 2 L, 3.2 L, 4.2 L |
| Regulatory Compliance | 21 CFR Part 11, GLP/GMP-ready |
| Flow Monitoring Technology | Acoustic-based real-time flow measurement (<5% error across viscosity range) |
| Mixing Modes | N₂ bubbling, variable-speed oscillation, recirculation |
| Solvent Ports | 7 |
| Reagent Ports | 20 |
| Waste Ports | 2 (separable streams) |
| Collection Port | 1 (optional) |
| Valve System | Chemically inert PurePep® Pathway manifold with Single-Shot pre-activation architecture |
| IQ/OQ Support | Available via certified field engineers |
| [Brand | ACT/Tetras |
|---|---|
| Origin | USA |
| Model | Tetras 106-Channel Peptide Synthesizer |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale per Reactor | 30–1000 µmol or 0.01–3 g resin |
| Max Reactor Count | ≤106 |
| Reactor Volumes | 6 mL, 25 mL, 40 mL, 60 mL |
| Syringe Pump Accuracy | <1% |
| Synthesis Purity | ≥99.5% |
| Flow Rate | 0.25–1 mL/s] |
| Brand | Sepure Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Low-Throughput Synthesizer |
| Coupling Efficiency | DNA >99% |
| Oligonucleotide Length Range | 5–80 bases |
| Synthesis Scale | 50 µmol – 9 mmol |
| UV Detector Wavelength Range | 200–800 nm (4-channel simultaneous detection) |
| Max Operating Pressure | 2 MPa |
| Pump Type | High-Precision Dual Plunger Pumps |
| Flow Rate | ≤ 2 × 100 mL/min |
| Column Reactor Count | 7 |
| Standard Monomer Inlets | 12 |
| Waste Outlets | 8 |
| System Protection | Inert Gas (N₂/Ar) Purge |
| Power Supply | 220 VAC / 600 W |
| Dimensions (W×H×D) | 583 × 614 × 523 mm |
| Included Accessories | PEEK/PTFE Tubing Kit, Installation Manual, User Manual, Fittings, Basic Tool Set |
| Brand | TSIKER |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | 080 |
| Amino Acid Delivery | Fully Automated |
| Synthesis Scale | 0.025–5 mmol |
| Reactor Quantity | 1 |
| Reactor Volume Options | 10 mL, 30 mL, 125 mL, 200 mL |
| Brand | TSIKER |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TSIKER Biotech Co., Ltd. |
| Model | Syn-AJY-5L |
| Pressure Rating | 550 kPa (safety limit) with triple safety protection |
| Max Operating Pressure | 600 kPa (auto rapid vent) |
| Temperature Control Range | Ambient to 90 °C |
| Throughput | Dual 96-well plates (192 oligonucleotide strands per run) |
| Deprotection Efficiency | ≥99% under standard 90 °C / 2 h protocol |
| Dimensions | 600 × 400 × 400 mm (L×W×H) |
| Weight | 40 kg |
| Safety Features | Electronic overpressure alarm, automatic gas cutoff, mechanical pressure relief valve |
| End-of-cycle Alert | Audible tone |
| Brand | TSIKER |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | Syn-CHY-192 |
| Pricing | Upon Request |
| Brand | TSIKER |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Tsingke Biotech Co., Ltd. |
| Type | Low-throughput synthesizer |
| Coupling Efficiency | ≥99% |
| Max. Oligo Length | 200 nt |
| Channels | 12 independent synthesis columns |
| Scale Range | 10 nmol – 100 µmol per column |
| Cycle Time | ≤6 s per coupling step |
| Base Bottle Positions | 10–28 |
| Auxiliary Reagent Positions | 6–9 |
| Dimensions (L×W×H) | 850 × 550 × 1050 mm |
| Weight | 34 kg |