Thermal Conductivity Analyzer
Filter
Showing 151–180 of 200 results
| Brand | Xiatech |
|---|---|
| Model | TC1000 Series (Customizable) |
| Origin | Shaanxi, China |
| Thermal Conductivity Range | 0.05–50 W/(m·K) |
| Axial Range | 0.2–50 W/(m·K) |
| Radial Range | 0.05–5 W/(m·K) |
| Sample OD | 150 mm |
| Wall Thickness | 1–200 mm |
| Length | 100–1500 mm |
| Temperature Range | −30 to 100 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Accuracy | ±3 % to ±8 % |
| Repeatability | ±3 % |
| Test Atmosphere | Air |
| Dimensions (L×W×H) | 1100×800×1500 mm |
| Data Interface | USB |
| Operating System | Windows |
| Ambient Conditions | 0–40 °C, ≤65 % RH |
| Power Supply | 220 V, 50 Hz |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC1000 Series |
| Instrument Type | Guarded Hot Plate Method |
| Sample Capacity | Single specimen per test |
| Test Environment | High-Temperature & Ambient-Pressure (standard configuration) |
| Dimensions (L×W×H) | 550 × 500 × 650 mm |
| Accuracy | ±3–5% (full scale) |
| Thermal Conductivity Range | 0.002–2.0 W/(m·K) |
| Repeatability | ≤1% RSD |
| Test Atmosphere | Air (standard) |
| Sample Form | Solid blocks (rigid or semi-rigid), thickness 10–50 mm, minimum face area 150 × 150 mm |
| Brand | Xiatech |
|---|---|
| Model | TC1100E |
| Measurement Principle | Guarded Hot Plate Method |
| Temperature Range | Hot Plate: RT+10 °C to 100 °C |
| Cold Plate | –5 °C to 90 °C |
| Thermal Conductivity Range | 0.002–2 W/(m·K) |
| Accuracy | ±3% (±1% near room temperature) |
| Repeatability | ±1% |
| Temperature Control Stability | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Thermal Resistance Range | 0.02–4 (m²·K)/W |
| Thickness Resolution | 0.0001 mm |
| Applied Pressure | < 2.5 kPa (manually applied) |
| Sample Dimensions | 300 mm × 300 mm × (5–40) mm |
| Sample Form | Rigid or semi-rigid solid slab |
| Test Atmosphere | Ambient air |
| Compliance Standards | GB/T 10294, ISO 8302, ASTM C177 |
| Brand | Xiatech |
|---|---|
| Model | TC1200 |
| Measurement Principle | Guarded Hot Plate Method |
| Temperature Range | Hot Plate: RT+10°C to 300°C, Cold Plate: RT to 300°C |
| Thermal Conductivity Range | 0.002–2 W/(m·K) |
| Accuracy | ±3% (±1% near room temperature) |
| Repeatability | ±1% |
| Resolution | 0.0001 W/(m·K) |
| Temperature Control Stability | ±0.05°C |
| Temperature Resolution | 0.01°C |
| Sample Dimensions | 300 × 300 × (5–40) mm |
| Maximum Test Temperature | 300°C |
| Test Atmosphere | Ambient Air |
| Sample Compression | Automated, <2.5 kPa |
| Thickness Measurement | Integrated Automatic Sensor |
| Compliance | GB/T 10294, ISO 8302, ASTM C177 |
| Brand | Xiatech |
|---|---|
| Model | TC1500 |
| Measurement Principle | Guarded Hot Plate Method |
| Temperature Range | Hot Plate RT+10 °C to 500 °C, Cold Plate RT+10 °C to 500 °C |
| Thermal Conductivity Range | 0.002–2.0 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±5% (±3% within 100 °C) |
| Repeatability | ±1% |
| Sample Dimensions | 300 mm × 300 mm × (5–40) mm |
| Sample Form | Solid Block |
| Test Atmosphere | Ambient Air |
| Compliance | ASTM C177, ISO 8302, GB/T 10294 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC2000 |
| Measurement Principle | Heat Flow Method (Guarded Hot Plate Variant) |
| Thermal Conductivity Range | 0.1–30 W/(m·K) |
| Accuracy | ±3–5 % |
| Repeatability | ±2 % |
| Sample Form | Solid (including powders, pastes, and rigid/flexible solids) |
| Sample Dimensions | Ø50 mm, thickness 0.5–30 mm (customizable) |
| Test Atmosphere | Ambient air |
| Operating Temperature | Room temperature (RT) |
| Applied Pressure | 0–0.28 MPa |
| Thickness Resolution | 0.001 mm (via integrated displacement sensor) |
| Thermal Resistance Range | 0.001–0.05 (m²·K)/W |
| Data Interface | USB |
| Power Supply | 220 V, 50 Hz |
| Compliance | ASTM E1530 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC2110 |
| Measurement Principle | Heat Flow Meter Method |
| Thermal Conductivity Range | 0.005–2 W/(m·K) |
| Thermal Resistance Range | 0.02–4 (m²·K)/W |
| Resolution | 0.001 W/(m·K) |
| Sample Diameter | Φ100–Φ160 mm or 300×300 mm |
| Sample Thickness | 5–40 mm (customizable) |
| Accuracy | ±3 % |
| Repeatability | ±2 % |
| Temperature Range | −10 to 100 °C |
| Pressure Range | 0–2.5 kPa |
| Test Atmosphere | Ambient air |
| Sample Forms | Insulation materials, composites, multilayer structures, porous media, building materials, pastes, powders |
| Compliance Standards | GB/T 10295, ISO 8301, ASTM C518 |
| Data Interface | USB |
| Power Supply | 220 V, 50 Hz |
| Brand | XIATECH |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC2120 Series |
| Instrument Type | Heat Flow Method |
| Sample Capacity | Single sample per test |
| Test Environment | High-pressure compatible (up to 10 MPa) |
| Thermal Conductivity Range | 0.05–50 W/(m·K) |
| Accuracy | ±3–5% |
| Repeatability | ±2% |
| Test Atmosphere | Ambient air |
| Sample Forms | Solid blocks, powders, pastes |
| Thickness Measurement | Laser displacement sensor (resolution ≤1 µm, min. measurable thickness: 0.1 mm) |
| Temperature Control Stability | ±0.05 °C |
| Compliant Standard | ASTM D5470 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000 Series |
| Measurement Principle | Transient Hot Wire (THW) |
| Thermal Conductivity Range | 0.001–50 W/(m·K), extendable to 100 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Form Compatibility | Solid blocks, sheets, powders, granules, pastes, gels, liquids (no geometric constraints) |
| Test Atmosphere | Ambient air |
| Operating Temperature | High-temperature capable (ambient to ≥200 °C, system-dependent) |
| Dimensions (L×W×H) | 550 × 500 × 650 mm |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000 |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Sample Form | Solid, Liquid, Gel, Powder, Granular, Paste |
| Test Atmosphere | Ambient Air |
| Operating Pressure | Atmospheric |
| Dimensions (L×W×H) | 550 × 500 × 650 mm |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Brand | Xiatech |
|---|---|
| Model | TC3000E |
| Measurement Principle | Transient Hot Wire Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Resolution | 0.0005 W/(m·K) |
| Sample Temperature | Ambient (20–25 °C) |
| Test Atmosphere | Air (vacuum module optional) |
| Sample Forms | Solid blocks, sheets, powders, granules, pastes, gels, liquids |
| Minimum Solid Sample Size | >25 mm edge length (thickness varies by material) |
| Minimum Liquid/Gel/Paste Volume | >50 mL |
| Data Acquisition Time | 1–20 s |
| Dimensions (L×W×H) | 350 × 250 × 150 mm |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Interface | USB |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000E-04 |
| Measurement Principle | Transient Hot Wire Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Resolution | 0.0005 W/(m·K) |
| Sample Forms | Solid, Liquid, Paste, Gel, Powder |
| Test Atmosphere | Air or Vacuum |
| Operating Temperature | 10–40 °C |
| Dimensions (L×W×H) | 350×250×150 mm |
| Power Supply | 220 V, 50 Hz |
| Data Interface | USB |
| Measurement Time | 1–20 s |
| Minimum Sample Thickness | 0.1 mm |
| Minimum Sample Lateral Dimension | 25 mm (circular or square) |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000E-03 |
| Measurement Principle | Transient Hot Wire Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Resolution | 0.0005 W/(m·K) |
| Sample Form Compatibility | Solid (block, sheet), powder, paste, gel, liquid |
| Sample Geometry | Unrestricted (circular or square |
| Test Environment | Ambient air or vacuum |
| Operating Temperature Range | 10–40 °C |
| Measurement Duration | 1–20 s per test |
| Dimensions (L×W×H) | 350 × 250 × 150 mm |
| Power Supply | 220 V, 50 Hz |
| Data Interface | USB |
| Software Platform | Windows-based acquisition and analysis suite |
| Compliance Standards | ASTM C1113, ASTM D5930, GB/T 10297-1998, GB/T 11205-2009 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000E (Educational Edition) |
| Measurement Principle | Transient Hot Wire Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume | ≥50 mL (liquids/gels/pastes) or ≥25 mm edge length (solids) |
| Dimensions (L×W×H) | 350×250×150 mm |
| Operating Environment | Ambient temperature (20–25 °C), ≤65% RH, air atmosphere |
| Sample Forms | Solids, powders, granules, gels, pastes, liquids |
| Data Interface | USB |
| OS Compatibility | Windows |
| Acquisition Time | 1–20 s |
| Resolution | 0.0005 W/(m·K) |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000E-1 |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) |
| Repeatability | ±3% |
| Accuracy | ±3% |
| Sample Forms | Solid, Liquid |
| Test Atmosphere | Air or Vacuum |
| Operating Environment | Ambient Pressure |
| Temperature Range | Room Temperature (20–25 °C) |
| Sample Size Requirement | Minimum dimension >25 mm |
| Dimensions (L×W×H) | 350 × 250 × 150 mm |
| Sample Throughput | Single-sample sequential testing |
| Brand | XIATECH |
|---|---|
| Model | TC3000L Series |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Origin | Shaanxi, China |
| Instrument Type | Liquid & Gas Thermal Conductivity Analyzer |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Sample Volume Required | 40 mL |
| Test Duration | ≤2 s per measurement |
| Temperature Range | −30 to 250 °C |
| Pressure Range | 0.1–15 MPa |
| Test Atmosphere | Vacuum or Controlled Gas Environment |
| Sample States | Liquid and Gaseous Fluids |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Xiatech |
|---|---|
| Model | TC3000L |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | –30 to 200 °C (depending on configuration) |
| Pressure Range | 0.1–15 MPa |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±2–3% |
| Repeatability | ±2–3% |
| Sample Volume Required | ≥40 mL |
| Sample States | Liquid and gaseous phases |
| Test Atmosphere | Vacuum-compatible |
| Dimensions (L×W×H) | 550×500×600 mm |
| Compliance | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3000L-1 |
| Measurement Principle | Transient Hot-Wire Method |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Sample Volume Required | 30 mL |
| Test Duration | ≤2 s per measurement |
| Temperature Range | −30 to 200 °C |
| Pressure Range | 0.1–15 MPa |
| Test Atmosphere | Vacuum-compatible |
| Sample Form | Liquid only |
| Compliance | ASTM D2717, ASTM D7896 |
| Dimensions (L×W×H) | Not specified |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC3000S |
| Instrument Principle | Transient Line Source Method (Single-Sided) |
| Sample Throughput | Single sample per measurement |
| Operating Environment | Ambient temperature (20–25 °C, 40–60% RH) |
| Dimensions (L×W×H) | 350 × 250 × 150 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.001–10 W/(m·K) |
| Repeatability | ±3% |
| Test Atmosphere | Air (standard ambient) |
| Sample Forms | Solids, liquids, pastes, gels, powders, granules |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3100 Series |
| Measurement Principle | Transient Hot Wire Method |
| Thermal Conductivity Range | 0.001–50 W/(m·K) (extendable to 100 W/(m·K)) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Resolution | 0.0005 W/(m·K) |
| Measurement Time | 1–20 s per test |
| Sample Forms | Solid, powder, granular, liquid, paste, gel, colloidal |
| Sample Dimensions (Solid) | Min. thickness 0.1 mm, min. lateral dimension ≥25 mm |
| Sample Volume (Liquid/Paste/Gel) | ≥50 mL |
| Operating Temperature Range | –30 °C to 100 °C |
| Test Atmosphere | Ambient air |
| Enclosure Dimensions (L×W×H) | 550 × 500 × 650 mm |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Data Interface | USB |
| OS Compatibility | Windows |
| Brand | Xiatech |
|---|---|
| Model | TC3100L / TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | −30 °C to 250 °C |
| Pressure Range | 0.1 MPa to 25 MPa |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±2–3% |
| Repeatability | ±2–3% |
| Sample Forms | Liquids and Gases |
| Test Atmospheres | Air, Vacuum, Inert Gases |
| Sample Throughput | Single-sample mode |
| Compliance | ASTM D2717-05, ASTM D7896-14 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3100L Low-Temperature Liquid Type |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | −30 °C to 100 °C |
| Pressure Range | 0.1–15 MPa |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±2 % |
| Repeatability | ±2 % |
| Sample Form | Liquid |
| Sample Throughput | Single sample per test |
| Test Atmosphere | High-pressure inert or controlled gas environment |
| Dimensions (L×W×H) | 50 cm × 50 cm × 70 cm |
| Measurement Time | ≤2 s |
| Brand | XIATECH |
|---|---|
| Model | TC3100L |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | −30 to 100 °C |
| Pressure Rating | Up to 15 MPa |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Resolution | 0.0001 W/(m·K) |
| Sample Volume | ≥40 mL |
| Measurement Time | ≤2 s |
| Test Atmosphere | Air, Vacuum, or Controlled Gas |
| Compliance | ASTM D2717, ASTM D7896 |
| Dimensions (L×W×H) | 55 cm × 50 cm × 65 cm |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200 |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Sample Form | Solid & Liquid |
| Test Atmosphere | Ambient Air |
| Temperature Capability | High-Temperature Operation |
| Dimensions (L×W×H) | 550 × 500 × 650 mm |
| Accuracy | ±3–5% |
| Thermal Conductivity Range | 0.001–50 W/(m·K), extendable to 100 W/(m·K) |
| Repeatability | ±3% |
| Sample Throughput | Single-sample sequential mode |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L High-Temperature Liquid Type |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | 10 °C above ambient to 200 °C |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Accuracy | ±3 % |
| Repeatability | ±3 % |
| Pressure Range | 0.1–15 MPa |
| Sample Form | Liquid |
| Test Duration | ≤2 s |
| Dimensions (L×W×H) | 50 cm × 50 cm × 70 cm |
| Operating Atmosphere | Pressurized inert or controlled gas environment |
| Compliance | Designed for ASTM D7896-21 and ISO 22007-2 compliant workflows |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3200L |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Temperature Range | Ambient to 200 °C |
| Pressure Range | 0.1–15 MPa (optional pressure control) |
| Thermal Conductivity Range | 0.0005–5 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±3% |
| Sample Volume Requirement | ≥40 mL |
| Measurement Time | ≤2 s |
| Sample Forms | Liquids and gases |
| Test Atmospheres | Vacuum, air, inert gas |
| Dimensions (L×W×H) | 550×500×650 mm |
| Compliance Standards | ASTM D2717, ASTM D7896 |
| Data Interface | USB |
| Operating System | Windows |
| Brand | Xiatech |
|---|---|
| Model | TC3300 |
| Measurement Principle | Transient Hot Wire Method |
| Temperature Range | –150 °C to Ambient |
| Thermal Conductivity Accuracy | ±5% |
| Repeatability | ±3% |
| Sample Forms | Solid, Paste, Powder, Liquid |
| Sample Dimensions | ≥25 mm (solid edge length) |
| Test Atmosphere | Air |
| Compliance | ASTM C1113, ASTM D5930, GB/T 10297, GB/T 11205 |
| Maximum Operating Pressure | High-Pressure Compatible |
| Sample Throughput | Single-sample per cycle |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3400L (Gas Version) |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | −160 °C to 25 °C |
| Thermal Conductivity Range | 0.0005–2 W/(m·K) |
| Accuracy | ±3 % |
| Repeatability | ±3 % |
| Pressure Range | 0.1–15 MPa |
| Sample Form | Gaseous |
| Test Duration | ≤2 s |
| Dimensions (L×W×H) | 50 cm × 50 cm × 80 cm |
| Compliance | Designed for ISO 22007-2 and ASTM D7896-compliant thermal transport characterization |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3400L |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | −160 °C to Ambient |
| Pressure Range | 0.1–15 MPa |
| Thermal Conductivity Range | 0.0005–2 W/(m·K) |
| Accuracy | ±3 % |
| Repeatability | ±3 % |
| Sample Form | Liquid |
| Dimensions (L×W×H) | 50 cm × 50 cm × 80 cm |
| Measurement Time | ≤2 s |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | TC3500L |
| Measurement Principle | Transient Hot-Wire Method |
| Temperature Range | RT+10°C to 650°C |
| Pressure Range | 0.1–5 MPa |
| Thermal Conductivity Range | 0.0005–0.5 W/(m·K) |
| Accuracy | < ±10% |
| Repeatability | ±5% |
| Sample State | Gaseous |
| Test Duration | ≤2 s |
| Dimensions (L×W×H) | 50 cm × 50 cm × 80 cm |
| Compliance | Designed for ASTM D7896-21 and ISO 22007-2 compliant workflows |