| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PTBCR-200 |
| Product Type | Portable |
| Turbidity Range | 0.00–400 NTU |
| Color Range | 1.0–500 PCU |
| Resolution | 0.01 PCU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % F.S. (Turbidity), ≤ ±3 % F.S. (Color) |
| Repeatability | ≤ ±2 % F.S. |
| Drift | < 0.002 A/h |
| Power | Rechargeable Li-ion Battery |
| Weight | 1.0 kg |
| Dimensions | 80 × 230 × 55 mm |
| IP Rating | IP65 |
| Data Storage | 20 calibration curves + 199 measurement records |
| Interface | USB |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PTURB-201 |
| Form Factor | Portable |
| Measurement Range | 0–400 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % FS |
| Repeatability | ≤ ±2 % FS |
| Drift | < 0.1 NTU/h |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | 10 calibration curves + 199 measurement records (non-volatile memory) |
| Housing | IP65-rated ABS polymer enclosure |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions | 80 × 230 × 55 mm |
| Weight | 1.0 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PTURB-201A |
| Form Factor | Portable |
| Measurement Range | 0–400 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±1 % FS |
| Drift | < 0.1 NTU/h |
| Weight | 1.0 kg |
| Dimensions | 80 × 230 × 55 mm |
| Power Supply | Rechargeable Lithium Battery |
| Data Storage | 199 measurements + 20 calibration curves |
| Protection Rating | IP65 |
| Display | Backlit LCD (Chinese interface) |
| Interface | USB port |
| Optical System | Cold LED source, narrow-band interference filter, fixed-path 5 cm cuvette geometry |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | PTURB-202A |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±1 % FS |
| Drift | < 0.1 NTU/h |
| Minimum Detectable Resolution | 0.01 NTU |
| Power Supply | Rechargeable Lithium Battery |
| Weight | 1 kg |
| Dimensions | 80 mm × 230 mm × 55 mm |
| IP Rating | IP65 |
| Display | Backlit LCD (Chinese interface) |
| Data Storage | 20 calibration curves + 199 measurement records |
| Interface | USB port |
| Environmental Protection | ABS molded housing with corrosion-, water-, and dust-resistant design |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PTURB-203 |
| Product Type | Portable |
| Measurement Range | 0–400 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % FS |
| Repeatability | ≤ ±2 % FS |
| Drift | < 0.1 NTU/h |
| Weight | 1 kg |
| IP Rating | IP65 |
| Power Supply | AC (220 ±10%) V, 50 Hz |
| Storage Capacity | 20 calibration curves + 500 measurement records |
| Optical System | Narrow-band interference filter with cold LED light source |
| Housing Material | Molded ABS |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PTURB-302 |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % |
| Housing Rating | IP65 |
| Power Management | Up to 6 months standby (typical) |
| Data Storage | 20 calibration curves + 500 measurement records |
| Optical System | Narrow-band interference filter with cold LED light source |
| Construction | Molded ABS housing |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TBCR-200 |
| Form Factor | Benchtop / Laboratory |
| Turbidity Range | 0–1000 NTU |
| Color Range | 0–500 CPU |
| Turbidity Resolution | 0.01 NTU |
| Turbidity Accuracy | ±2% FS |
| Color Accuracy | ±3% FS |
| Repeatability | ≤±2% FS |
| Drift | <0.1 NTU/h |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC (220±10%) V, 50 Hz |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 4 kg |
| Light Source | Imported high-intensity LED (100,000 h lifetime) with narrow-band optical filtering |
| Display | Backlit LCD with Chinese menu interface |
| Data Storage | 10 calibration curves + 500 measurement records (non-volatile memory) |
| Connectivity | USB port for data export |
| Optional | Thermal printer support |
| Housing Material | Molded ABS with corrosion resistance |
| Microcontroller | Low-power 16-bit MCU architecture |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-3C |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–400 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1 % FS |
| Repeatability | ≤ ±2 % FS |
| Drift | < 0.1 NTU/h |
| Display | 5-inch color TFT touchscreen (bilingual UI) |
| Data Interface | USB port for data export and PC connectivity |
| Calibration | Onboard self-calibration with user-defined standard curves |
| Memory | 300 calibration curves, 1,000 measurement records (non-volatile) |
| Housing | Molded ABS with corrosion resistance |
| Power Supply | AC 220 V ±10 %, 50 Hz |
| Dimensions | 400 × 310 × 158 mm |
| Weight | 5 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-6A |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0.00–400 NTU |
| Resolution | 0.01 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±2 % FS |
| Repeatability | ≤ ±2 % |
| Optical Stability | ≤ 0.002 A/20 min |
| Display | Color Touchscreen (English & Chinese) |
| Dimensions | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Power Supply | AC (220 ± 22) V, (50 ± 0.5) Hz |
| Power Consumption | < 100 W |
| Humidity Limit | ≤ 85 % RH (non-condensing) |
| Data Storage | 3,500 calibration curves + 100,000 measurement records (non-volatile) |
| Interface | USB port for PC connectivity |
| Calibration | Built-in self-calibration function |
| Recovery | One-touch system restore |
| Print Support | Integrated thermal or external printer support (via USB or serial) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TURB-6B |
| Form Factor | Benchtop / Laboratory |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Operating Temperature | 5–40 °C |
| Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±2% FS |
| Optical Drift | <0.002 A over 20 min |
| Display | Color Touchscreen with English & Chinese UI |
| Dimensions | 400 × 300 × 140 mm |
| Weight | 2.6 kg |
| Power Consumption | <100 W |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Humidity Limit | ≤85% RH non-condensing |
| Data Storage | 3500 calibration curves + 100,000 measurement records (non-volatile) |
| Connectivity | USB port for PC data export |
| Compliance | Designed per ISO 7027:2016 principles (nephelometric detection at 860 nm), supports GLP-compliant audit trails via timestamped calibration logs and operator ID tagging |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH-50Z (New Release) |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01/0.1 NTU with Automatic Range Switching |
| Operating Temperature | 0–50 °C (non-freezing) |
| Accuracy | <8% FS |
| Principle | 90° Nephelometric Scattering |
| Light Source | 850 nm Infrared LED |
| Response Time | 15 s |
| Drift | ≤0.02 NTU |
| Sample Cell | 25 mm Diameter Cuvette |
| Display | 5.0-inch IPS HD Touchscreen |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 251 × 102 × 55 mm |
| Net Weight | 700 g |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH-50Z |
| Price Range | USD 0.15–750 (FOB) |
| Type | Portable |
| Measurement Range | 5–200 NTU |
| Resolution | 0.001 NTU |
| Operating Ambient Temperature | 10–30 °C |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Zero Drift | <0.001 NTU |
| Data Storage | 8 GB internal microSD card (capacity for ≥5 million records) |
| Light Source | Long-life LED (cold white, 850 nm nominal wavelength) |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Power Supply | Integrated rechargeable Li-ion battery (≥12 h continuous operation) |
| Connectivity | USB 2.0 host/device port for data export and firmware update |
| Calibration | Factory-calibrated |
| Brand | Supelco |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1100IR |
| Price Range | USD 2,800 – 7,000 |
| Type | Portable |
| Measurement Range | 0.01–1100 NTU |
| Resolution | 0.01 NTU (0–100 NTU range) |
| Operating Ambient Temperature | 10–30 °C |
| Accuracy | ±2% of reading or ±0.01 NTU, whichever is greater |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | OD-Monitor A&S |
| Measurement Range | 0.00–2.55 OD / 0.00–9.99 OD |
| Resolution | 0.1 NTU (OD-equivalent) |
| Operating Temperature | +15°C to +50°C |
| Accuracy | ±0.5% to ±1.5% (at specified OD range) |
| Configuration | Benchtop Laboratory System |
| Detection Principle | Near-Infrared Transmittance (950 nm) |
| Output Interface | USB 2.0, RS-232C |
| Channel Capacity | 8-channel simultaneous measurement |
| Calibration | User-adjustable correction factor (0.01–2.55) referenced to E. coli OD₆₀₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | AQ3010 |
| Measurement Principle | 90° Nephelometric Detection (ISO 7027 Compliant) |
| Light Source | Infrared LED |
| Measurement Range | Auto-ranging 0.01–1000 NTU |
| Resolution | 0.01 NTU (0.01–19.99), 0.1 NTU (20.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading +1 LSD (0–500 NTU) |
| Response Time | <6 s |
| Sample Volume | 10 mL |
| Calibration Standards | 0.02, 20.0, 100, and 800 NTU EPA-compliant formazin equivalents |
| Sample Cell | 25 mm diameter, numbered vials |
| Protection Rating | IP67 |
| Power Supply | 4 × AAA alkaline batteries (≥3,000 measurements) or lithium (≥12,000 measurements) |
| Auto-power-off | After 20 min idle |
| Operating Temperature | 0–50 °C (RH 0–90% at 30 °C) |
| Certifications | CE, TÜV 3-in-1 (CSA-US), FCC Part 15 |
| Self-diagnostic Function | Yes, with error code display |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Online Turbidimeter |
| Model | AquaClear |
| Measurement Range | 0–200 NTU |
| Resolution | ±2% of reading (<40 NTU), ±5% of reading (>40 NTU) |
| Accuracy | 0.001 NTU |
| Operating Ambient Temperature | −20 to +60 °C |
| Sample Temperature Range | −5 to +50 °C |
| Flow Rate | 250–500 mL/min |
| Response Time | 90 s to 90% of final value |
| Light Source | Tungsten lamp (≥3-year lifetime) |
| Flow Cell Volume | 135 mL |
| Optical Cell Material | Quartz and anodized aluminum |
| Compliance | EPA Method 180.1 |
| Temperature Units | °C, °F |
| Output Interface | Plug-and-play communication adapter |
| Detection Principle | Nephelometric measurement at 90° (ISO 7027-compliant geometry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable (not online) |
| Model | AQ3700-2 |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–90% RH (non-condensing at 30 °C) |
| Light Source | LEDs at 430, 530, 560, 580, 610, 660 nm |
| Photometric Accuracy | ±2% of full scale |
| Photometric Resolution | ±0.005 Abs |
| Zero Calibration | Deionized water |
| Sample Volume | 10 mL |
| Data Storage | 1000 measurements with timestamp |
| Power | Rechargeable battery (>3000 measurements per charge) |
| Communication | Infrared (IR) |
| Auto Power-Off | 20 min inactivity |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | TN 100 |
| Pricing | Upon Request |
| Principle | ISO 7027-compliant Nephelometric Measurement (850 nm Infrared LED) |
| Range | 0–1000 NTU with Auto-ranging (0.01–19.99 NTU, 20.0–99.9 NTU, 100–1000 NTU) |
| Resolution | 0.01 NTU (0–19.99), 0.1 NTU (20–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% ±1 digit (0–500 NTU) |
| Repeatability | ≤±1% of reading |
| Calibration Points | 4-point (0.02, 20.0, 100, 800 NTU) |
| Calibration Accuracy | ±0.02 NTU at low point |
| Response Time | <6 seconds |
| Sample Volume | 10 mL |
| Light Source | 850 nm infrared LED |
| Operating & Sample Temperature | 0–50 °C |
| Enclosure Material | ABS plastic |
| Ingress Protection | IP67 |
| Power Supply | 4 × 1.5 V AAA alkaline batteries (>1200 measurements per set) |
| Dimensions (Instrument) | 15.5 × 6.8 × 4.6 cm |
| Weight (Instrument) | 200 g |
| Packaging Dimensions | 35.5 × 16.5 × 10.5 cm |
| Weight (Packaged) | 1160 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AQ4500 |
| Price | Upon Request |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Series | WGZ-1 / WGZ-200 / WGZ-800 |
| Instrument Type | Portable turbidimeter |
| Measurement Principle | 90° scattered light detection (ISO 7027 compliant) |
| Measurement Range | WGZ-1: 0–100 NTU & 0–200 NTU |
| WGZ-200 | 0–20 NTU & 0–200 NTU |
| WGZ-800 | 0–200 NTU & 0–800 NTU |
| Minimum Readout | WGZ-1: 0.1 NTU |
| WGZ-200 | 0.01 NTU |
| WGZ-800 | 0.1 NTU |
| Basic Error | ±2.5% F.S. (WGZ-1) |
| Repeatability | ≤1% |
| Zero Drift | ±0.5% F.S. (equivalent to ±0.2 NTU for WGZ-1/WGZ-800 |
| Operating Temperature | 0–25 °C |
| Resolution | 0.2 NTU (typical display resolution across series) |
| Key | Brand: Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Series | WGZ-200A, WGZ-2A, WGZ-2, WGZ-3, WGZ-3A, WGZ-100 |
| Type | Portable Turbidimeter |
| Measurement Principle | 90° Nephelometric Scattering |
| Range | 0–1000 NTU (model-dependent) |
| Resolution | 0.001–0.01 NTU |
| Accuracy | ±2% F.S. |
| Repeatability | ≤1% |
| Zero Drift | ±0.5% F.S. (at 0.02–0.1 NTU) |
| Operating Temperature | 25 °C ambient |
| Compliance | ISO 7027, ASTM D6508, USP <241>, GLP-ready architecture |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | TB1 |
| Type | Portable |
| Measurement Range | 0–1000 NTU |
| Repeatability | ±0.01 NTU or ±1% of reading (higher repeatability for gel samples) |
| Light Source | Infrared LED (850 nm) |
| Detection Angle | 90° (ISO 7027 compliant) |
| IP Rating | IP67 (waterproof) |
| Weight | 200 g |
| Dimensions | 68 × 50 × 155 mm |
| Calibration | Single-point using standard reference solutions (e.g., Formazin or StablCal) |
| Brand | Wetlabs |
|---|---|
| Origin | USA |
| Model | ECO-NTU |
| Type | Submersible Online Turbidimeter |
| Measurement Ranges | 0–70 NTU, 0–200 NTU, or 0–1000 µg/L (selectable) |
| Resolution | 0.01 NTU |
| Accuracy | ±0.01 NTU |
| Wavelength | 700 nm |
| Housing Material | Polyoxymethylene (POM), seawater-corrosion-resistant |
| Dimensions | Ø63 × 127 mm |
| Weight | 0.4 kg (air), 0.02 kg (water) |
| Depth Rating | Standard 600 m, optional 6000 m |
| Output | RS-232 (19200 baud), 0–5 V analog |
| Digital Resolution | 12-bit |
| Sampling Rate | 8 Hz |
| Internal Data Logging | Optional, up to 65,000 samples |
| Power Input | 7–15 VDC |
| Current Draw | 80 mA (active), 85 µA (sleep mode) |
| Connector | SUB-CONN Micro 5-pin male |
| Optional Features | Internal Li-ion battery, anti-fouling copper brush (programmable cycle), biofouling guard, handheld terminal interface |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 2000 |
| Type | Online Turbidimeter |
| Measurement Range | 0–1000 NTU (Turb 2000) |
| Resolution | 0.0001 NTU |
| Operating Temperature | 1 °C – 50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU), ±5% of reading (>40 NTU) |
| Light Sources | Infrared LED (DIN 7027 compliant), Tungsten Halogen Lamp (USEPA Method 180.1 compliant) |
| Enclosure Rating | IP66 |
| Optional | Ultrasonic Cleaning System |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 430IR |
| Product Type | Portable |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10.0–99.9), 1 FNU/NTU (100–1100) |
| Operating Temperature | 0 °C to 50 °C |
| Accuracy | ±2% of reading or ±0.01 FNU/NTU (whichever is greater) |
| Ingress Protection | IP67 |
| Light Source | Infrared LED compliant with ISO 7027 and DIN 27027 |
| Response Time | 4 s |
| Calibration | 1–3 point automatic calibration with AMCO-GP standards (0.02, 10, 1000 FNU/NTU) |
| Data Storage | 1000 measurement records with timestamp |
| Interface | RS232, USB (optional) |
| Power Supply | 4 × AA batteries (~3000 measurements per set) |
| Compliance | CE, cETLus, GLP/AQA-ready, ISO 7027-compliant |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 430T / Turb 430IR |
| Type | Portable |
| Measurement Range | 0–1100 NTU with automatic range switching |
| Resolution | 0.01 NTU (0.00–9.99 NTU) / 0.1 NTU (10.0–99.9 NTU) / 1 NTU (100–1100 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.01 NTU or ±2% of reading |
| Repeatability | <±0.5% of reading or 0.01 NTU |
| Light Source | Turb 430IR — IR-LED at 860 nm |
| Response Time | 3 s (IR) / 7 s (tungsten) |
| Calibration | Automatic 1–3 point calibration |
| Data Storage | 1000 measurement records + calibration protocols |
| Real-Time Clock | Yes |
| Interface | RS232 and USB (with adapter) |
| Power Supply | 4 × AA alkaline batteries (≈2000 measurements with tungsten lamp |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 430T |
| Product Type | Portable |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 NTU (0.00–9.99 NTU) |
| Operating Temperature | 0 °C to 50 °C |
| Accuracy | ±2% or ±0.01 FNU/NTU (whichever is greater) for 0–500 NTU |
| Measurement Principle | 90° Nephelometric Scattering (EPA Method 180.1 compliant) |
| Light Source | Tungsten Halogen Lamp |
| Response Time | ≤7 s |
| Sample Cell | 28 × 60 mm cylindrical cuvette (20 mL volume) |
| Data Storage | 1000 measurements with timestamp |
| Interface | RS232 standard, USB optional |
| Ingress Protection | IP67 |
| Certifications | CE, cETLus |
| Calibration | Automatic 1–3 point calibration with AMCO-EPA traceable standards (0.02 / 10 / 1000 NTU) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 550T / Turb 550IR |
| Measurement Principle | 90° Nephelometric Scattering |
| Light Source | Tungsten Lamp (Turb 550T) / Infrared LED (860 nm, Turb 550IR) |
| Range | 0.01–1000 NTU / FNU |
| Resolution | 0.01 NTU (0.01–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading or ±0.01 NTU |
| Repeatability | <1% of reading or ±0.01 NTU |
| Response Time | <3 s |
| Calibration | Automatic 1–3-point with AMCO® standards (0.02 / 10.0 / 1000 NTU) |
| Sample Temperature Range | +10 to +40 °C |
| Data Interface | RS-232 |
| Power Supply | 100–240 VAC, 47–63 Hz (adapter output: 15 VDC / 1 A) |
| Dimensions | 290 × 252 × 100 mm |
| Weight | 1.0 kg |
| Compliance | Turb 550IR — DIN 27027 / ISO 7027 |
| GLP Functionality | Yes |
| Optional Flow Cell | Available |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 750 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 NTU for Turb 750T) |
| Compliance Standards | DIN EN ISO 7027-1 (Turb 750IR), US EPA Method 180.1 (Turb 750T) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, printer port |
| GLP-Compliant Software | Turb Data PC software (CSV export, LIMS import, user authentication, audit trail) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 600120 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 FNU/NTU) |
| Compliance Standard | DIN EN ISO 7027-1 |
| Light Source | Infrared LED |
| Detection Angle | 90° Nephelometric Scattering |
| Display | Backlit Graphic LCD (160 × 104 pixels) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, optional printer |
| GLP Support | Full audit trail, user ID, sample ID, calibration interval tracking, electronic signatures via Turb Data software |