| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | sensION+ MM378 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Parameters | pH, ORP (mV), ISE, Conductivity, Dissolved Oxygen (DO) |
| Dual-Channel Architecture | Channel 1 (pH/ORP/ISE/Conductivity), Channel 2 (DO) |
| GLP Compliance | Yes |
| Data Storage Capacity | 400 measurement records |
| Temperature Compensation | Automatic (NTC or Pt1000), Electrode Isoelectric Point Detection Supported |
| Software Integration | LabCom PC Software (optional, bidirectional control) |
| Accessories Included | pH electrode, conductivity electrode, polarographic DO probe, magnetic stirrer (dual-control capable), electrode stand, base, beakers, and calibration accessories |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | SL1000/250 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Colorimetric Parameters | Free Chlorine, Total Chlorine, Free Ammonia, Total Ammonia, Monochloramine, Nitrite, Copper, Alkalinity, Phosphate, Dissolved Iron, Hardness, Peracetic Acid |
| Electrochemical Parameters | pH, Conductivity, Dissolved Oxygen (DO), Temperature, Ion-Selective Electrode (ISE) |
| Measurement Capacity | Up to 6 parameters simultaneously |
| Technology | Chemkey® Microfluidic Cartridge-Based System (U.S. Patents #9012234, #9052302, #9180449, #9182353) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | SP510 |
| Detection Principle | Colorimetric (EDTA Complexometric Titration) |
| Measurement Range | 0.3–100 mg/L as CaCO₃ |
| Accuracy | ±10% of setpoint (0.3–2 mg/L), ±4% of setpoint (5–100 mg/L) |
| Cycle Time | ~2 minutes per measurement |
| Alarm Output | 1 SPDT relay |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL, CSA, CE |
| Reagent Consumption | Up to 2 months per reagent pack |
| Maintenance Interval | Pump tube replacement every 6 months |
| Calibration | Automatic on-demand and scheduled calibration |
| Brand | Hach |
|---|---|
| Model | SP510 |
| Origin | USA |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Colorimetric Method (Calcium/Magnesium Complexation with Arsenazo III) |
| Measured Parameter | Total Hardness (as CaCO₃) |
| Range | 0.3–100 mg/L as CaCO₃ |
| Repeatability | ≤4% RSD |
| Accuracy | ±10% of setpoint at 0.3–2 mg/L |
| Cycle Time | ~2 minutes per measurement |
| Calibration | Automatic on-board standardization using factory-preloaded reagent cartridges |
| Reagent Consumption | One cartridge supports ~60 days of continuous operation |
| Maintenance Interval | Pump tubing replacement every 6 months |
| Alarm Outputs | 1 SPDT relay (configurable setpoints: 0.3, 1, 2, 5, 10, 20, 50, 100 mg/L) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Certifications | UL 61010-1, CSA C22.2 No. 61010-1, CE marked per EMC and LVD directives |
| Compliance | Designed for use in industrial water treatment environments requiring GLP-aligned operational traceability |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HGCF-100 |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | Total Cyanide, Free Cyanide, Volatile Phenols, Anionic Surfactants (LAS), Ammonia-Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfides, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Model | HGCF-200 / HGCF-210 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Parameters | Total Cyanide, Free Cyanide, Volatile Phenol, Anionic Detergents, Ammonia Nitrogen (NH₃-N), Orthophosphate, Total Phosphorus, Total Nitrogen, Sulfide, Hexavalent Chromium (Cr⁶⁺), Nitrate, Nitrite, Permanganate Index (CODₘₙ), Urea |
| Compliance Standards | HJ 665–2013, HJ 670–2013, HJ 667–2013, CJT 141–2018, SL/T 788–2019, NY/T 1121.7–2014, NY/T 1228–2015, ISO 14403:2012, ISO 14402:1999, ISO 23913:2016, ISO 15681-2:2003 |
| Optical Detection | Dual-beam silicon photodetector or full-spectrum CCD detector |
| Flow Cell Pathlength Options | 10 mm to 200 mm |
| Reaction Coil | 2 mm i.d. quartz mixing coil |
| Sample Introduction | Automated sampler with carbon fiber or borosilicate glass probe, auto-cleaning and wash solution auto-replacement |
| Online Pretreatment | Integrated heating, digestion, distillation, dialysis, extraction, degassing, dilution, and mixing modules |
| Light Source | Low-power LED with short stabilization time and >10,000 h lifetime |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI98185 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Ion Selective Electrode (ISE), Temperature |
| Display | 128×64 backlit LCD |
| IP Rating | IP67 |
| Dimensions | 226.5 × 95 × 52 mm |
| Weight | 525 g |
| Power | Rechargeable Li-ion battery (200 h operation), inductive charging |
| Data Storage | 200 measurement records |
| Interface | USB (with optional HI92000 software) |
| Calibration | Auto 5-point pH (7 built-in + 5 user-defined buffers) |
| up to 5-point ISE (6 built-in standards | 0.1–10000 ppm) |
| Accuracy | pH ±0.01 / ±0.002 |
| Resolution | pH 0.1 / 0.01 / 0.001 |
| GLP Compliance | Yes (timestamped calibration logs, electrode diagnostics, auto-endpoint lock, calibration alert) |
| Brand | HEYL (Neomeris) |
|---|---|
| Origin | Germany |
| Model | Testomat ECO / Testomat 2000 |
| Measurement Parameter | Total Calcium and Magnesium Hardness (as CaCO₃) |
| Power Supply | 230 V or 24 V ±10 %, 50–60 Hz |
| Power Consumption | ≤30 VA |
| Ingress Protection | IP65 |
| Electrical Safety Class | Class I |
| Compliance | EN 50081-1, EN 50082-2, EN 61010-1 |
| Operating Ambient Temperature | 10–45 °C |
| Sample Inlet Temperature | 10–40 °C |
| Operating Pressure Range | 0.1–3 bar (optional pressure regulator: 1–8 bar) |
| Dimensions (W×H×D) | 380 × 480 × 280 mm |
| Weight | ~9.5 kg |
| Display | Backlit LCD with text-based menu navigation |
| Output Signals | Two programmable relay outputs |
| Maintenance Alert Output | Yes |
| Analog Output | 4–20 mA |
| Mounting | Wall-mounted |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Measurement Principle | Colorimetric photometric analysis using EDTA-based titration chemistry |
| Optional Configurations | Dual-channel measurement (Testomat 2000 only) |
| Sampling Frequency Modes | Time-based interval, pulse-triggered (e.g., flow meter signal), volume-proportional, or factory preset cycle |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-173 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Conductivity Range | 0–199 µS/cm, 0.2–1.99 mS/cm, 2–19.9 mS/cm |
| Resolution | 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm |
| Accuracy | ±2% of reading |
| Salinity Range | 0–1.1% (w/w) |
| Temperature Compensation | Automatic, 5–35 °C with 2%/°C coefficient |
| Power Supply | Two 3V CR2032 batteries (approx. 500 hours lifespan) |
| Dimensions | 15 × 2 × 2 cm (L × W × H) |
| Included | Calibration standard solution (1410 µS/cm KCl) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | D-50 |
| Measurement Parameters | pH, Temperature, ORP, Conductivity (D-54), Dissolved Oxygen (D-55), Ion Selective Electrode (ISE) capability (D-53) |
| Enclosure Rating | IP67 |
| Power Supply | DC 3 V (LR6 batteries) |
| Weight | 300–330 g |
| Interface | RS-232C for PC/printer connectivity |
| Display | Backlit LCD with dual-channel readout |
| Data Logging | Automatic storage with timestamp |
| Self-Diagnostic Function | Yes |
| Electrode Compatibility | Ruggedized waterproof pH/ORP probes, interchangeable sensor modules |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-51 Series |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurement Parameters | pH, Temperature |
| pH Range | 0.00–14.00 (glass electrode method) |
| pH Resolution | 0.01 pH |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| pH Repeatability | ±0.01 pH ±1 digit |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Power Supply | DC 3 V (two AA/LR6 batteries) |
| Weight | Approx. 300 g |
| IP Rating | IP67 (waterproof housing) |
| Data Interface | USB (PC connectivity for data transfer and tabular export) |
| Display | Large backlit LCD screen |
| Features | Auto-data storage, self-diagnostic function, dual-channel measurement capability |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-55 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| ORP Range | ±1999 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy | ±1 mV |
| Dissolved Oxygen Range | 0.00–19.99 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.01 mg/L |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic (0–100 °C) |
| Data Interface | RS-232 or USB (PC/printer compatible) |
| IP Rating | IP67 (dust-tight and immersion-resistant up to 1 m for 30 min) |
| Display | Large backlit LCD |
| Data Logging | Auto-storage with timestamp |
| Self-Diagnostic Function | Yes |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-72 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurement Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 (Glass Electrode Method), Resolution: 0.01 pH |
| ORP Range | −2000 to +2000 mV, Resolution: 1 mV |
| Temperature Range | 0.0–100.0 °C, Resolution: 0.1 °C |
| Accuracy (Repeatability) | pH ±0.01 pH ±1 digit |
| Power Supply | Two LR03 (AAA) Alkaline Batteries |
| Weight | Approx. 270 g |
| IP Rating | IP67 (Waterproof Construction) |
| Data Interface | RS-232 or USB (via optional adapter) |
| Compliance | Designed for field-deployable environmental monitoring per ISO 5667-3, ASTM D1293, and EPA Method 150.1 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-71 / DS-72 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Display | Monochrome LCD (DS-71) / Full-color Capacitive Touchscreen (DS-72) |
| Data Storage | 999 entries (DS-71) / 2000 entries (DS-72) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Connectivity | USB host/device interface, GLP/GMP-compliant printer & PC communication |
| Languages | English, Japanese, Chinese, Korean |
| Temperature Range | 0.0–100.0 °C (display) |
| Conductivity Measurement Principle | Two-electrode AC excitation method (dual-frequency, temperature-compensated) |
| Conductivity Ranges | 0.000 mS/m – 199.9 S/m (depending on cell constant: 10, 100, or 1000 m⁻¹) |
| Resolution | 0.05% of full scale |
| Salinity | 0.00–80.00 ppt (0.000–8.000 wt%) |
| Resistivity | 0.000 Ω·m – 1.999 MΩ·m |
| TDS | 0.01 mg/L – 1000 g/L |
| Repeatability | ±0.5% F.S. (conductivity/resistivity), ±0.1 °C (temperature) |
| Power | AC adapter (100–240 V, 50/60 Hz) |
| consumption | 0.7 VA (DS-71), 9.8 VA (DS-72) |
| Weight | ~500 g (DS-71), ~700 g (DS-72) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Data Storage Capacity | 999 measurement records |
| Display | Capacitive Touchscreen (English, Chinese, Japanese, Korean) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVIII, CP 2020 |
| Measurement Principles | Dual-electrode AC conductivity (2-electrode alternating current method) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DS-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Data Storage Capacity | 999 measurement records |
| Display | Capacitive touchscreen (multilingual: English, Chinese, Japanese, Korean) |
| Temperature Range | −30.0 to 130.0 °C (display range: 0.0–100.0 °C), Resolution: 0.1 °C, Repeatability: ±0.1 °C ±1 digit |
| Conductivity Measurement Principle | Dual-electrode AC excitation method |
| Conductivity Ranges (by cell constant) | 10 m⁻¹: 0.0 µS/m – 1.999 S/m |
| 100 m⁻¹ | 0.000 mS/m – 19.99 S/m |
| 1000 m⁻¹ | 0.00 mS/m – 199.9 S/m |
| Resolution | 0.05% of full scale |
| Repeatability | ±0.5% FS ±1 digit |
| Resistivity (calculated from conductivity) | 10 m⁻¹: 0.0 Ω·m – 1.999 MΩ·m |
| 100 m⁻¹ | 0.00 Ω·m – 199.9 kΩ·m |
| 1000 m⁻¹ | 0.000 Ω·m – 19.99 kΩ·m |
| Salinity Range | 0.00–80.00 ppt (0.000–8.000%), Resolution: 0.01 ppt (0.001%) |
| TDS Range | 0.01 mg/L – 100 g/L, Resolution: 0.01 mg/L |
| Compliance | JIS Z 8809, USP <645>, EP 2.2.38, JP XVIII, CP 2020 Chapter 0803 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, Temperature, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS |
| Measurement Principle | pH (Glass Electrode), Ion (Ion-Selective Electrode), Conductivity (AC Two-Electrode Method) |
| pH Range | 0.000–14.000 (Resolution: 0.001 pH) |
| ORP Range | ±1999.9 mV (Resolution: 0.1 mV) |
| Temperature Range | 0.0–100.0 °C (Display Resolution: 0.1 °C) |
| Conductivity Range (Configurable via Cell Constant) | 0.000 mS/m – 199.9 S/m |
| Salinity Range | 0.00–80.00 ppt (Resolution: 0.01 ppt) |
| Resistivity Range (Cell Constant Dependent) | 0.000 Ω·m – 1.999 MΩ·m |
| TDS Range | 0.01 mg/L – 1000 g/L (Resolution: 0.01 mg/L) |
| Repeatability | ±0.005 pH, ±0.1 mV (ORP), ±0.1 °C (Temp), ±0.5% F.S. (Conductivity/Resistivity/Salinity/TDS) |
| Data Storage | 999 measurements |
| Interface | USB (PC communication & optional USB memory support) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Software Features | GLP/GMP-compliant data logging, calibration traceability, on-screen diagnostic navigation, multi-language UI (English, Japanese, Chinese, Korean) |
| Power Supply | AC Adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 |
| Type | Benchtop Laboratory Water Quality Analyzer |
| Measured Parameters | pH, Temperature, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Data Storage | Up to 999 measurements |
| Interface | USB (host & device), GLP/GMP-compatible printer support |
| Display | Monochrome LCD with intuitive navigation |
| Languages | English, Japanese, Chinese, Korean |
| Power | AC adapter (100–240 V, 50/60 Hz) |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 Series |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Data Storage | Up to 2000 measurements |
| Connectivity | USB interface for PC communication and optional USB mass storage |
| Display | Capacitive touchscreen (F-74BW), multi-language support (English, Japanese, Chinese, Korean) |
| GLP/GMP Support | Audit-trail-capable data logging, calibration history, electrode diagnostics |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | HORIBA F-71G, F-72G, F-73G, F-74G, F-75G, D-71A-S, D-72A-S, D-73A-S, D-74A-S, D-75A-S, ES-71A-S, OM-71-2A-S, OM-71-10, OM-71-L1 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.001 / 0.01 |
| pH Accuracy | ±0.001 |
| mV Range | ±1999.9 |
| mV Resolution | 0.1 |
| mV Accuracy | ±0.1 |
| ISE Range | 0.00–999 g/L |
| ISE Resolution | 3 significant figures |
| ISE Accuracy | ±5% |
| Conductivity Range | 0.00 µS/cm–199.0 S/m |
| TDS Range | 0.01–1000 g/L |
| Conductivity/TDS Resolution | 0.5% of full scale |
| Conductivity/TDS Accuracy | ±0.5% of full scale |
| Salinity Range | 0.00–80.00 ppt |
| Resistivity Range | 0.0001 µS/cm–199.0 S/m |
| Salinity/Resistivity Resolution | 0.5% of full scale |
| Salinity/Resistivity Accuracy | ±0.5% of full scale |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Auto Temperature Compensation | 0–100 °C |
| Data Storage Capacity | 2000 measurements |
| Interface | USB |
| Enclosure Rating | IP67 |
| Dimensions (L×W×H) | 17 × 17 × 7.4 cm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 Series |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Measurement Principles | pH (glass electrode), ORP (redox electrode), Ion (ion-selective electrode), Conductivity (2-electrode AC method) |
| Display Resolution | pH up to 0.001, ORP ±0.1 mV, Temp 0.1 °C, Conductivity 0.05% FS, TDS/Resistivity/Salinity per IEC 60746-3 |
| Data Storage | Up to 2000 records (F-72/F-73/F-74), GLP/GMP-compliant audit trail support |
| Compliance | JIS Z 8802, USP <645>, EP 2.2.38, JP XVII, CP 2020, ISO 7888, ASTM D1125, FDA 21 CFR Part 11 (via software configuration) |
| Connectivity | USB host/device, optional thermal printer interface |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 0.5–0.7 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 Series |
| Measurement Parameters | pH, ORP, Ion Concentration, Conductivity, Resistivity, Salinity, TDS, Temperature |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Data Storage | Up to 2,000 records (model-dependent) |
| Interface | USB port for PC connectivity and optional USB mass storage |
| Display | Capacitive touchscreen (F-74BW), multi-language support (English, Japanese, Chinese, Korean) |
| Power | AC adapter (100–240 V, 50/60 Hz) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-70 Series |
| Instrument Type | Laboratory Water Quality Analyzer |
| Key Parameters | pH (0.000–14.000, resolution 0.001), ORP (±1999.9 mV, resolution 0.1 mV), Temperature (−30.0–130.0 °C, resolution 0.1 °C), Ion Concentration (0.00 µg/L–999 g/L), Conductivity (0.000 mS/m–199.9 S/m, 3 cell constants), Resistivity (0.000 Ω·m–1.999 MΩ·m), Salinity (0.00–80.00 ppt), TDS (0.01 mg/L–1000 g/L) |
| Compliance | JIS, USP <645>, EP 2.2.38, JP/CP Pharmacopoeial Standards |
| Data Storage | Up to 2000 measurements |
| Connectivity | USB host/device, GLP/GMP-compliant data export |
| Display | Capacitive touchscreen (F-74BW), multilingual UI (EN/JP/ZH/KO) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Temperature |
| Measurement Principle | Glass Electrode (pH), Redox Electrode (ORP), Nernst Equation-Based Ion Concentration |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Repeatability | ±0.005 pH |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (Display) | 0.0–100.0 °C (extended range: −30.0–130.0 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Data Storage Capacity | 999 measurement records |
| Display | Full-color capacitive touchscreen |
| Language Support | English, Japanese, Chinese, Korean |
| Power Supply | AC adapter (100–240 V, 50/60 Hz) |
| Power Consumption | Approx. 0.7 VA |
| Net Weight | ~500 g |
| Included Accessories | Electrode stand, user manual, AC adapter |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Repeatability | ±0.005 pH ±1 digit |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Temperature Range | 0.0–100.0 °C (–30.0 to 130.0 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 999 entries |
| Power Supply | AC adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Measurement Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Repeatability | ±0.005 pH ±1 digit |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 999 measurements |
| Power Supply | AC adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Net Weight | ~500 g |
| Compliance | JIS, USP, EP, JP, CP |
| Display | Capacitive touchscreen |
| Interface | USB (device & host), GLP/GMP-ready data export |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Repeatability | ±0.005 pH ±1 digit |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Temperature Range | 0.0–100.0 °C (–30.0 to 130.0 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 999 measurements |
| Power Supply | AC adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Compliance | JIS, USP, EP, JP, CP |
| Language Support | English, Japanese, Chinese, Korean |
| Interface | USB communication |
| Accessories Included | Electrode stand, operation manual, AC adapter |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 pH |
| pH Repeatability | ±0.005 pH ±1 digit |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Temperature Range | 0.0–100.0 °C (–30.0–130.0 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 999 measurements |
| Power Supply | AC adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Net Weight | ~500 g |
| Compliance | JIS, USP, EP, JP, CP |
| Connectivity | USB interface for PC communication |
| Language Support | English, Japanese, Chinese, Korean |
| Electrode Interface | Single-channel glass electrode input |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-71 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (Display) | 0.0–100.0 °C (Extended: −30.0–130.0 °C) |
| Temperature Resolution | 0.1 °C |
| pH Repeatability | ±0.005 pH ±1 digit |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 999 measurements |
| Power Supply | AC adapter, 100–240 V, 50/60 Hz |
| Power Consumption | ~0.7 VA |
| Weight | ~500 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | F-72 |
| Measurement Parameters | pH, ORP, Ion Concentration, Temperature |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 pH |
| pH Repeatability | ±0.001 pH ±1 digit |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV ±1 digit |
| Ion Range | 0.00 µg/L – 999 g/L (mol/L) |
| Ion Resolution | 3 significant digits |
| Ion Repeatability | ±0.5% F.S. ±1 digit |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C ±1 digit |
| Data Storage Capacity | 2000 sets |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Net Weight | ~700 g |
| Compliance | JIS, USP <645>, EP 2.2.38, JP XVII, CP 0407 |