X-Ray Instruments
Filter
Showing 691–720 of 783 results
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | xstress3000 |
| Cooling | Air-cooled (no water required) |
| Deployment | Lab and field-portable |
| Weight | <15 kg (typical for xstress series) |
| Measurement Principle | Sin²ψ X-ray diffraction (XRD) |
| Compliance | ASTM E915, ISO 21945, EN 15305 |
| Data Access | Real-time in-measurement data viewing |
| Setup Time | ≤10 minutes |
| Interface | USB/RS-232 to Windows PC with embedded Microsoft Windows OS |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | xstress3000 |
| X-ray Tube | 5–30 kV / 0–10 mA, 300 W max |
| Target Materials | Cr, Cu, Co, Ti, Mn |
| Detector | MOS linear position-sensitive proportional counter (512 pixels, 0.029°/pixel angular resolution) |
| 2θ Range | 117–170° continuous adjustment |
| Goniometer Geometry | Modified y-geometry (side-inclination) with dual symmetric detectors |
| Collimators | Interchangeable |
| Calibration | Fully automated, positioning accuracy < 0.003 mm |
| Cooling | Closed-loop liquid cooling with active heat dissipation |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Safety Compliance | Interlocked beam shutdown on window breach, coolant fault, or mechanical displacement |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Xstress3000 |
| Quotation | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Xstress3000 |
| X-ray Tube | 5–30 kV / 0–10 mA / 300 W adjustable |
| Target Materials | Cr, Cu, Co, Ti, Mn |
| Detector Geometry | Dual symmetric detectors, side-inclination (y-geometry) |
| 2θ Range | 110°–171° continuous adjustment |
| Collimator Options | Ø0.5 mm, Ø0.8 mm, Ø1 mm, Ø2 mm, Ø3 mm, Ø5 mm |
| d-sin²ψ Measurement Mode | Multi-point with cross-correlation peak shift analysis |
| Calibration | Fully automated, positioning error < 0.003 mm |
| Cooling | Closed-loop recirculating system with active forced cooling |
| Safety | Integrated interlocks and radiation shielding compliant with IEC 61010-1 and EN 62495 |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | XSTRESS3000 |
| X-ray Tube Power | 300 W |
| 2θ Angular Range | 110°–170° (continuously adjustable) |
| ψ Angular Range | −60° to +60° |
| Target Material | Chromium (Cr) |
| Compliance | Designed for ASTM E915, ISO 21432, and EN 15305-compliant residual stress evaluation |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | xstress3000 |
| Cooling | Air-cooled (no water cooling required) |
| Portability | Benchtop & field-deployable design |
| Compliance | Designed for ISO 21432, ASTM E915, and EN 15305-compliant residual stress measurement |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | xstress3000 |
| X-ray Tube | 5–30 kV / 0–10 mA / 300 W adjustable |
| Target Materials | Cr, Cu, Co, Ti, Mn |
| 2θ Range | 117°–170° continuous adjustment |
| Geometry | Modified y-geometry (side-inclination) |
| Detector Configuration | Symmetrically mounted dual detectors |
| Software Platform | Windows-based with real-time HV monitoring, multi-point exposure mode, cross-correlation peak shift analysis, and built-in material database |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Tube Replacement | Tool-free, completed in <5 minutes |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | xstress3000 |
| Type | Portable X-ray Diffraction (XRD)-Based Residual Stress Analyzer |
| Compliance | ASTM E915, ISO 21432, EN 15305, SAE AMS 2569 |
| Measurement Principle | Sin²ψ Method with Monochromatic Cr-Kα Radiation |
| Detector | High-Sensitivity CCD or Image Plate (Configurable) |
| Goniometer | Precision Motorized θ–2θ Dual-Axis System |
| Sample Positioning | Manual or Optional Motorized XYZ Stage |
| Weight | <12 kg (Typical System Configuration) |
| Power Supply | 100–240 V AC, 50/60 Hz or Internal Battery (Optional) |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Xstress3000G3 |
| Power Supply | Single-phase AC |
| Cooling | Integrated liquid recirculation system (no external water required) |
| Angular Resolution | 0.014°–0.057° |
| Detector Type | Dual symmetric MOS linear imaging detectors |
| Operating System | Windows-compatible software platform |
| Compliance | Designed for ISO 21940, ASTM E915, and EN 15305-compliant residual stress measurement procedures |
| Safety | Full interlock architecture per IEC 61010-1 and IEC 62471 |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Model | TD-5000 |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Configuration | Floor-Standing |
| X-ray Source Power | 3 kW |
| 2θ Angular Repeatability | 0.0001° |
| Minimum Step Angle | 0.0001° |
| Temperature Control Range | 100 K – 300 K |
| Temperature Stability | ±0.3 K |
| Detector | PILATUS Hybrid Pixel Detector |
| Goniometer Architecture | Four-Circle Concentric Design |
| Data Acquisition Interface | Touchscreen-Controlled PLC System |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TD-Mini |
| Price Range | USD 70,000 – 140,000 |
| X-ray Tube Power | 60 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Tilt Angle Range | 0° to ±45° |
| Anode Target Material | Chromium (Cr) |
| X-ray Source | Fine-focus Ceramic Tube with Integrated Closed-loop Self-circulating Cooling System |
| Detector | High-speed Silicon Strip Photon-counting Area Detector (640-channel linear array), Total Count Rate > 1×10⁹ cps |
| Brand | Tongda |
|---|---|
| Model | TD-RSD |
| X-Ray Tube Anode Material | Cr |
| Maximum Power | 3 kW |
| Detector Type | Photon-Counting Area Detector (Dual Symmetric Configuration) |
| Angular Positioning Accuracy | ≤ 0.01° (2θ) |
| Stress Measurement Repeatability (Stress-Free Iron Powder) | σ < ±7 MPa (n = 5) |
| Sample Stage | Motorized XYZ + Φ Tilt Stage |
| Cooling System | Integrated Closed-Loop Ceramic X-Ray Tube Cooling |
| Compliance | ASTM E915, ISO 21432, EN 15305 |
| Dimensions (W×D×H) | 1300 × 1200 × ~1800 mm |
| Target Options | Cr, Cu, Mn, Co, V, Ti, Fe, Mo |
| Brand | Tongda |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TDTC-150 |
| Price Range | USD 70,000 – 140,000 |
| X-ray Tube Power | 200 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Tilt Angle Range | 0° to ±45° |
| Anode Target Material | Chromium (Cr) |
| Measurement Methods | Sin²ψ, Side-Inclination, Tilt-and-Rotate |
| Stress Output | Principal Stresses (σ₁, σ₂, σ₃) and Shear Stress (τ) |
| Phase Analysis Mode | Four-Peak Method for Retained Austenite Quantification |
| Detector | Multi-channel Silicon Strip Linear Array Detector |
| Control System | PLC-based Modular Architecture |
| Operating System | Integrated Windows OS with Real-time Data Visualization |
| Sample Compatibility | Ferrous & Non-ferrous Metals, Titanium Alloys, Nickel-Based Superalloys, Glass, Composites |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARL PERFORM'X Sequential WDXRF |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | ARL Perform’X |
| Instrument Type | Floor-standing |
| Instrument Class | Scanning-type |
| X-ray Tube Power Options | 1500 W / 2500 W / 4200 W |
| Elemental Range | Be to U (Atomic Number 4 to 92) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ARL QUANT'X |
| Form Factor | Benchtop/Floor-standing |
| Application Scope | General-purpose |
| Elemental Range | F to U (no elemental restrictions) |
| Quantification Range | <1 ppm to 100% |
| Energy Resolution | ≤140 eV at Mn Kα |
| Short-term Precision | RSD < 0.3% over 8 hours |
| Detector | High-performance Peltier-cooled Silicon Drift Detector (SDD) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Bragg–Brentano θ/θ |
| Angular Accuracy | ±0.002° |
| Detector | Solid-state 2D pixel detector (55 × 55 µm pixel pitch) |
| Sample Handling | Manual 1-position holder or optional 6-position autosampler |
| X-ray Source | Cu or Co sealed-tube anode |
| Cooling | Optional water-cooling system |
| Data Output | Automated LIMS integration |
| Compliance | IEC 61000-4, IEC 62471, EN 61000-6-3, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China-manufactured under Thermo Fisher technology transfer & quality oversight) |
| Model | ARL™ QUANT EDXRF |
| Pricing | Available upon consultation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XL2 700 |
| Portability | Handheld / Portable |
| Elemental Analysis Range | Na (Z=11) to U (Z=92) |
| Detection Limit | Sub-ppm to low-ppm (matrix-dependent, 300 s measurement) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (for major elements in homogeneous standards) |
| Detector | Peltier-cooled Si-PIN |
| X-ray Tube | Au-anode, 40 kV / 50 µA |
| Measurement Spot Size | ≥4 mm × 4 mm |
| Data Storage | 4,000+ spectra + quantitative results |
| Battery Life | 6–12 h (dual rechargeable Li-ion) |
| Dimensions | 248 × 273 × 95 mm |
| Weight | 1.4 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-Made) |
| Model | Niton XL2 Plus Handheld ED-XRF Spectrometer |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XL3T700 |
| Form Factor | Handheld / Portable |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm (typical for heavy metals in homogeneous matrices) |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| X-ray Tube | Rh anode, 50 kV, 2 W |
| Detector | High-performance Si-PIN |
| Operating Temperature | –10 °C to 50 °C |
| Weight | <1.3 kg |
| Dimensions | 244 × 230 × 95.5 mm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Niton XLt 797RWY |
| Instrument Type | Portable |
| X-ray Tube Power | 400 W |
| Detectable Elements | Boron (B, Z=5) to Uranium (U, Z=92) |
| Detector Linearity Range | kCPS |
| Beryllium Window Thickness | µm |
| Detector | Peltier-cooled Si-PIN |
| Energy Resolution | <250 eV (FWHM at Mn Kα, 2σ confidence) |
| Weight | 1.4 kg |
| Dimensions | 248 × 273 × 95 mm |
| Battery Life | 6–12 h |
| Operating Voltage | 40 kV / 50 µA max |
| Filter System | Dual-filter configuration (Filter 2 optimized for Cl and Cr in halogen-free screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ARL 9900 |
| Instrument Type | Floor-standing |
| X-ray Tube Power Options | 1.2 kW, 2.5 kW, 3.6 kW, 4.2 kW |
| Elemental Range | Be to U (with appropriate analyzing crystals) |
| Sample Introduction | 8-position, 12-position or 98-position autosampler |
| Weight | ~750 kg |
| Max. Power Consumption | 4.8 kVA |
| Configuration | Scanning-type WDXRF spectrometer with optional simultaneous XRD channel |
| Brand | Thermo Fisher |
|---|---|
| Origin | France |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Powder X-ray Diffractometer |
| Model | ARL EQUINOX 100 |
| Power Stability | < 0.0001 (unitless relative stability, typical for high-stability X-ray tube power supply) |
| Detector | Integrated EQUINOX curved position-sensitive detector (CPSD) |
| Cooling | Fully integrated internal water-cooling system |
| Sample Handling | Optional 6-position autosampler, transmission powder holders, thin-film accessories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ARL EQUINOX Pro |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 3000 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL EQUINOX Pro Vertical X-ray Diffractometer |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Angular Accuracy | ±0.0001° |
| Resolution | FWHM < 0.026° (2θ, LaB₆ (110)) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | ARL EQUINOX Pro Vertical X-ray Diffractometer (XRD) |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Switzerland |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | ARL Optim’X |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 50 W / 200 W (equivalent via UCCO™ technology) |
| Elemental Range | F to U (73 elements) |
| Analysis Mode | Simultaneous (fixed-channel) and Sequential (scanning) |
| Cooling | Air-cooled, no external water circulation required |
| Sample Handling | Standard 1-position manual loader |
| Software | Thermo Scientific OXSAS with OptiQuant™ quantitative package |
| Compliance | Designed to meet ASTM E1361, ISO 2936, ISO 8258, and GLP/GMP data integrity requirements (21 CFR Part 11-ready audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ARL PERFORM'X Sequential |
| Price Range | USD 135,000–205,000 (FOB) |
| Instrument Type | Sequential WDXRF |
| X-ray Tube Power | 1.5 kW (ARL PERFORM'X 1500W), 2.5 kW (ARL PERFORM'X 2500W), 4.2 kW (ARL PERFORM'X 4200W) |
| Elemental Range | F (Z=9) to U (Z=92), plus C (Z=6) |
| Detection Limit | Sub-ppm for most elements in optimized matrices |
| Angular Positioning Accuracy | ≤0.0005° (Moiré fringe encoder-based goniometer) |
| Sample Form | Solids (pressed pellets, fused beads), Liquids (sealed cells), Powders, Coatings |
| Automation | Integrated XYZ sample changer with up to 120-position capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | ARL X'TRA Companion |
| Pricing | Available Upon Request |