X-Ray Instruments
Filter
Showing 751–780 of 786 results
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMX |
| Element Range | Na (11)–U (92) |
| Detection Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Capacity | 25-position automated carousel |
| Measurement Time | 100–300 s per sample |
| Vacuum Level | 1×10⁻² Pa (stable for ≥30 min) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Sample Mass | 3–8 g |
| Dimensions (L×W×H) | 970×750×1600 mm |
| Weight | 160 kg |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMG |
| Element Range | Na (11)–U (92) |
| Detection Limit | 0.1 ppm |
| Quantification Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Chamber | Top-illumination geometry with vacuum capability (10⁻²–10⁻⁵ Pa) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Measurement Time | 100–300 s |
| Sample Mass | 3–8 g |
| Dimensions | 750 × 670 × 1620 mm (D×W×H) |
| Weight | 135 kg |
| Compliance | GBZ 115–2002, registered with Ministry of Ecology and Environment of PRC |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SYB |
| Detector | Si(PIN) Semiconductor (Cryogenically Cooled) |
| X-ray Tube | 40 kV Tungsten Target Microfocus Source |
| Energy Resolution | <150 eV @ Mn Kα |
| Analytical Range | Na (11) to U (92) |
| LOD | Cd/Cr/Hg/Br ≤1 ppm, Pb ≤2 ppm, Cl ≤20 ppm |
| Measurement Range | 1–40 keV |
| High Voltage | 0–40 kV |
| Tube Current | 0–100 µA |
| Sample Chamber | Vacuum-Compatible Circular Cavity (Ø140 mm × H50 mm) |
| Measurement Time | 120–600 s |
| Power Supply | AC 220 V ±1%, 50 Hz, 1000 VA |
| Dimensions | 500 × 500 × 450 mm |
| Weight | 25 kg |
| Operating Temp. | 0–35 °C |
| Relative Humidity | ≤99% RH (non-condensing) |
| Rated Power | 50 W |
| Calibration Standard | Certified EU RoHS Reference Materials |
| Brand | Xenemetrix |
|---|---|
| Origin | Israel |
| Model | EX-6600 / X-7600 |
| Configuration | Benchtop & Floor-standing |
| Elemental Range | C(6)–Fm(100) |
| Detection Limit | 1 ppm |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | 129 eV (FWHM at 5.9 keV) |
| Repeatability | 0.1% |
| X-ray Tube | Rh anode, 60 kV / 300 W (EX-6600), 60 kV / 400 W (X-7600) |
| Detector | Silicon Drift Detector (SDD), standard or LE variant |
| Filter Set | 8-position motorized primary filters |
| Secondary Targets | 8 selectable targets |
| Sample Environment Options | Air, Vacuum, He purge |
| Sample Chamber Dimensions | Ø178 mm × H32 mm |
| Instrument Dimensions (L×W×H) | 85 × 85 × 105 cm (EX-6600), 85 × 85 × 105 cm (X-7600) |
| Weight | 170 kg (EX-6600), 220 kg (X-7600) |
| Software | nEXt™ quantitative analysis suite with fundamental parameters (FP) algorithm |
| Brand | Xenemetrix |
|---|---|
| Origin | Israel |
| Model | S-Mobile PD/SDD |
| Element Range | C(6)–Fm(100) |
| Detection Limit | sub-ppm |
| Energy Resolution | <130 eV (FWHM at 5.9 keV) |
| Repeatability | 0.1% |
| X-ray Tube | Rh anode, 50 kV / 50 W |
| Detector Options | Peltier-cooled PIN diode or Silicon Drift Detector (SDD) |
| Sample Chamber Dimensions | 121 × 112 × 45 cm |
| Weight | 25 kg |
| Compliance | ASTM D4294, D7217, ISO 20847, IP 531 |
| Brand | Xenocs |
|---|---|
| Origin | France |
| Model | Nano-inXider |
| Instrument Type | Integrated SAXS/WAXS System |
| Measurement Range | q_min ≈ 0.006 Å⁻¹ (corresponding to ~250 nm real-space correlation length, validated with SiO₂ nanoparticle standard) |
| Beam Size | 30 µm (FWHM) |
| Sample Consumption | < 1 µL for liquid samples |
| Acquisition Time | 1–30 min per measurement |
| Detector Mode | Virtual Detector enabled for extended WAXS angular coverage |
| Brand | Xenocs |
|---|---|
| Origin | France |
| Model | Xeuss PRO UHR |
| Instrument Type | Integrated Small-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS/USAXS) System |
| Measurement Range | Up to 900 nm (calibrated with SiO₂ nanoparticle standard, not derived from 2π/qₘᵢₙ) |
| Beam Size | 30 µm (FWHM) |
| Sample Consumption | Extremely Low (µL–nL range) |
| Typical Acquisition Time | 1–30 min per measurement |
| Source Options | Automated switching between Cu, Mo, Cr microfocus sealed-tube or rotating anode sources |
| Detector | Motorized 3-axis goniometer-mounted hybrid pixel detector (e.g., EIGER2 XE) |
| GISAXS/GIWAXS Capability | Yes, with incident-angle control and dedicated data reduction pipelines |
| Beamstop-Free Acquisition | Supported via direct-beam masking and dynamic background subtraction |
| Virtual Detector Mode | Enabled for extended q-range WAXS coverage |
| Software Platform | SAXSflow™ v5.x with GLP-compliant audit trail, FDA 21 CFR Part 11-ready user management, and ISO/IEC 17025-aligned reporting templates |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | XG5500-Automated |
| Pricing | Available Upon Request |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SME |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | 100 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| Excitation Source | Ag-anode microfocus X-ray tube, Be window (50 µm), 0–50 kV / 1–1000 µA adjustable |
| Measurement Atmosphere | Air or vacuum (down to 10⁻² Pa) |
| Sample Form | Powdered solids |
| Multi-channel Analyzer | 2048-channel digital MCA |
| Simultaneous Elements | ≥30 |
| Analysis Time | 60–180 s per sample |
| Dimensions | 650 × 600 × 730 mm |
| Weight | 65 kg |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SMP |
| Detector | Si(Li) semiconductor, energy resolution ≤150 eV (at 5.9 keV, ⁵⁵Fe) |
| Excitation Source | Miniature air-cooled X-ray tube |
| Measurable Elements | S, P, Ca, Ti, V, Mn, Fe, Ni, Cu, Zn, Mo, As, Sn, W |
| Detection Range | 0.001–99.99 wt% |
| Measurement Time | <200 s |
| Operating Voltage Range | 2–30 keV |
| Power Consumption | 4 W |
| Weight | 1.75 kg |
| Battery Life | ≥8 h (full-load operation) |
| Data Interface | Bluetooth, GPS, USB |
| Safety Indicators | Dual-color LED (green = power on |
| Compliance | CE, RoHS, IEC 61010-1, IEC 62471 |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMQ |
| Element Range | Na (11)–U (92) |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | ≤125 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Operating Voltage | 0–25 kV |
| Tube Current | 1–1000 µA |
| Measurement Time | 60–120 s per sample |
| Vacuum Capability | Yes |
| Detector | Peltier-cooled Si-PIN semiconductor |
| Energy Range | 1–30 keV |
| Simultaneous Elements | Up to 9 |
| Sample Mass | 10–15 g |
| Radiation Dose Rate | <25 µSv/h |
| Ambient Temp. | 10–35 °C |
| Humidity | 30–70% RH |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SY |
| Form Factor | Benchtop/Floor-standing |
| Application Domain | Geological & Petrological Core Logging |
| Elemental Range | Na–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | ≤100 eV (at Mn Kα, 5.9 keV) |
| Repeatability | RSD ≤0.05% (major elements, n=5) |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SYE |
| Origin | Sichuan, China |
| Detector Energy Resolution | <130 eV |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm |
| Analysis Time | 120 s (auto-optimized) |
| Operating Voltage | 0–40 kV |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 740 × 450 × 430 mm |
| Weight | ~55 kg |
| Sample Chamber | Ø300 × 100 mm (downward illumination) |
| Vacuum Capability | Yes |
| Software | Proprietary Windows-based EDXRF analysis suite with FP, empirical coefficient, and α-factor quantification methods |
| Compliance Support | ASTM E1621, ISO 8256, IEC 62321-5 for RoHS, GLP-ready audit trail & user access control |
| Brand | XOS |
|---|---|
| Model | Clora 2XP |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (Single-Wavelength XRF) |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.07 ppm (at 600 s) |
| Quantification Range | 0.07 ppm – 2 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Ethylene Tetrafluoroethylene (ETFE) film |
| Measurement Time | Adjustable from 30 to 900 seconds |
| Calibration | Multi-curve storage with automatic high-sulfur/low-chlorine correction |
| Motion-Free Optics | Dual hyperbolic bent-crystal optics (monochromator + analyzer) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Brand | XOS |
|---|---|
| Model | Clora |
| Instrument Type | Benchtop WDXRF Analyzer |
| Excitation | Monochromatic X-ray Beam |
| Target Element | Chlorine (Cl) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.13 ppm |
| Measuring Range | 0.13 ppm – 3000 ppm (standard), up to 4 wt% (optional) |
| Sample Volume | ≤10 mL |
| Measurement Time | 30–900 s (user-configurable) |
| Sample Form | Liquid hydrocarbons, aqueous solutions, solid powders (with AccuCell cup) |
| Compliance | ASTM D7536-16, ASTM D4929-19 (Method C), SH/T 0977-2019 |
| Optical System | Dual Hyperbolic Bent-Crystal Monochromators |
| Detector | High-resolution proportional counter or scintillation detector (configuration-dependent) |
| Calibration | Multi-curve storage, manual high-sulfur/low-chlorine correction |
| Optional Accessories | AccuFlow™ suspension compensation module, AccuCell™ sample cups, automated sample changer |
| Brand | XOS |
|---|---|
| Origin | USA |
| Model | Mini-Beam |
| Tube Type | Metal-Ceramic |
| Target Materials | Ag, Rh, W, Cu, Cr |
| Operating Voltage | 4–60 kV |
| Beam Current | 5–200 µA |
| Max Power | 12 W |
| Cooling | Forced Air |
| Operating Temp | –10 to +50 °C |
| Input Power | 110/220 VAC, 50/60 Hz |
| Dimensions | 305 × 102 × 76 mm (12 × 4 × 3 in) |
| Weight | 1.95 kg (4.3 lbs) |
| Focal Spot Size | ≤5 µm FWHM @ Rh Kα (20.162 keV) |
| Flux Gain vs. Pinhole | >1000× |
| Capillary Options | PF-004/PF-010/PF-020/PF-050 (focusing) & PC-004/PC-006/PC-010/PC-015 (collimating) |
| Brand | XOS |
|---|---|
| Model | Petra 4294 |
| Element Range | Sulfur (S) |
| Detection Limit | 2.6 ppm @ 600 s |
| Quantification Range | 2.6 ppm – 10 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤2% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Sample Format | Liquid or solid in disposable cups (vertical loading) |
| Compliance | ASTM D4294, ISO 8754, IP 336, GB/T 17040, GB/T 17606 |
| Power Requirement | Standard AC outlet (no gas, no combustion, no high-temperature operation) |
| Measurement Time | Adjustable from 30 to 900 seconds |
| Sample Volume | ≤10 mL |
| Footprint | Benchtop configuration with integrated drip tray and spill containment |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop/Lab-Floor Standing |
| Configuration | Standard Model |
| Application Sector | Energy & Petrochemicals |
| Elemental Range | S, P, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn |
| Quantification Range | 5.7 ppm – 10 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤2% RSD (at 100 ppm level) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | XOS |
|---|---|
| Model | Phoebe |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic Wavelength-Dispersive XRF |
| Target Element | Phosphorus (P) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.4 ppm (at 600 s) |
| Quantification Range | 0.4 – 3000 ppm |
| Sample Volume | ≤10 mL |
| Sample Containment | Prolene film |
| Measurement Time | 30–900 s (user-selectable) |
| Calibration | Multi-curve storage |
| Motion Components | None |
| Gas/Combustion Required | No |
| Operating Environment | Standard laboratory AC power only |
| Brand | XOS |
|---|---|
| Model | Signal |
| Instrument Type | Benchtop |
| Excitation | Monochromatic WDXRF |
| Target Element | Silicon (Si) |
| X-ray Tube Power | 75 W |
| Detection Limit (LOD) | 0.65 ppm (at 600 s) |
| Measurable Range | 0.65–3000 ppm |
| Sample Volume | ≤10 mL |
| Sample Membrane | Prolene film |
| Measurement Time | 30–900 s (user-configurable) |
| Compliance | ASTM D7757-17, NB/SH/T 0993-2019 |
| Brand | XOS |
|---|---|
| Model | Sindie +Cl |
| Instrument Type | Benchtop WDXRF Spectrometer |
| Excitation | Monochromatic Wavelength-Dispersive XRF (MWDXRF) |
| X-ray Tube Power | 75 W |
| Elements Analyzed | Sulfur (S), Chlorine (Cl) |
| LOD | 0.4 ppm (S), 0.3 ppm (Cl) |
| Quantification Range | 0.4 ppm – 5 wt% (S), 0.3 ppm – 3000 ppm (Cl) |
| Sample Volume | ≤10 mL |
| Sample Membrane | Mylar film |
| Measurement Time | 30–900 s (user-configurable) |
| Detector Configuration | Dual independent solid-state detectors |
| Compliance | ASTM D7039-15, ASTM D2622, ASTM D7536-16, ASTM D4929-19, ISO 20884:2019, NB/SH/T 0842-2017, SH/T 0977-2019, GB 11140-2008 |
| Brand | XOS |
|---|---|
| Model | Sindie R2 |
| Instrument Type | Benchtop |
| Excitation Principle | Monochromatic WDXRF (MWD-XRF) |
| Target Element | Sulfur (S) |
| X-ray Tube Power | 75 W |
| Detection Limit | 0.4 mg/kg @ 300 s |
| Measuring Range | 0.4 mg/kg – 3000 mg/kg and 3000 mg/kg – 10 wt% |
| Sample Volume | ≤10 mL |
| Sample Membrane | Polyethylene (Mylar) |
| Measurement Time | 10–999 s (user-selectable) |
| Display | 10-inch color touchscreen |
| Data Storage Capacity | >50,000 test records |
| Compliance Standards | ASTM D7039-15a(2020), ASTM D2622-21, NB/SH/T 0842-2017, ISO 20884:2019, GB/T 11140-2008 |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Excitation Source | 75 W Low-Power X-ray Tube |
| Analyte Element | Sulfur (S) |
| Detection Principle | Monochromatic Wavelength-Dispersive XRF |
| Compliance | ASTM D7039, ASTM D2622, NB/SH/T 0842, ISO 20884, GB/T 11140 |
| LOD | 0.18 mg/kg @ 300 s |
| Quantification Range | 0.18 mg/kg – 10 wt% (dual-range mode) |
| Sample Volume | ≤10 mL |
| Sample Cell | Accucell™ with Mylar® film |
| Measurement Time | 10–999 s (user-defined) |
| Data Storage | >50,000 test records |
| Display | 10-inch capacitive color touchscreen |
| Moving Parts | None in analyzer core |
| Calibration | Multi-curve storage, infrequent recalibration required |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XR-100CR |
| Pricing | Available Upon Request |
| Brand | YXLON International GmbH |
|---|---|
| Origin | Germany |
| Model | FF35 CT + ZoomScan |
| Max. Sample Rotation Radius | 260 mm |
| Max. Sample Height | 800 mm |
| Max. CT Scan Volume | 510 mm × 600 mm |
| Max. Payload | 27 kg |
| Motion Axes | 7 (standard), 8 (optional) |
| X-ray Source | 190 kV water-cooled microfocus tube, 225 kV refraction tube (dual-source optional) |
| Detector | CsI scintillator-based, multiple configurations available |
| Minimum Detectable Feature Size | 150 nm |
| ZoomScan Resolution Enhancement | 5×–10× vs. conventional CT |
| Scanning Modes | Full-volume CT, ROI-CT, FlexCenter + ZoomScan hybrid |
| Calibration Features | Focus drift auto-correction, ring artifact correction, noise calibration, beam hardening correction (material-specific), metal scatter correction, ScatterFix 2.0, automatic voxel segmentation |
| Brand | YXLON International GmbH |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FF35 CT |
| Pricing | Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | ASIDAXG5000 |
| Pricing | Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ZXI-3000 Series |
| Price Range | USD 70,000 – 140,000 |
| Detection Principle | X-ray Transmission Imaging |
| Measurement Capability | 2.5D Geometric Metrology |
| Motion Control | CNC-programmable Stage with Path Memory |
| Navigation | Real-time Click-to-Go Image Navigation |
| Image Format Support | DICOM, TIFF, PNG, BMP |
| Data Output | CSV, XML, PDF Reports |
| Software Compliance | Audit Trail Enabled, User Access Levels, GLP-Ready Logging |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XG5000 |
| Price | Upon Request |
| X-ray Tube | Sealed microfocus tube, integrated high-voltage power supply |
| Tube Voltage | 90 kV |
| Tube Current | 200 µA (software-limited to 89 µA) |
| Cooling Mode | Forced air cooling |
| Geometric Magnification | 12×–48× |
| X-Axis Travel | 400 mm |
| Y-Axis Travel | 450 mm |
| Z-Axis Travel | 150 mm |
| Image Intensifier Field of View | 2″ / 4″ |
| Resolution | 75 / 110 lp/cm |
| System Dimensions (W×D×H) | 1028 × 1025 × 1840 mm |
| Weight | ~760 kg |
| Power Supply | AC 250 V, 10 A |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 and FDA 21 CFR 1020.40) |
| Operating Temperature | 22 ± 3 °C |
| Computer | HP Elite 8200 CMT, Intel Core i3-2100 (3.1 GHz), 2 GB DDR3 RAM, 500 GB SATA HDD, Windows XP, 22″ widescreen LCD |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | XG5000 Series |
| Pricing | Available Upon Request |