| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-Sun Xe-3HBSE |
| Xenon Lamp Power | 3 × 1800 W |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Q-Sun Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Q-SUN Xe-8 |
| Xenon Lamp Power | 1.8 kW |
| Irradiance Range | 0.25–1.3 W/m² (at 340 nm) |
| Light Cycle | Programmable |
| Humidity Range | 10–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Cooling Method | Air-Cooled Xenon Arc Lamp |
| Lamp Life | 1500 hours (warranty) |
| Spectral Range | 295–800 nm (full-spectrum solar simulation) |
| Irradiance Control | SOLAR EYE® closed-loop feedback system |
| Temperature Monitoring | Black Panel Thermometer (BPT) or Black Standard Thermometer (BST) |
| Humidity Control | Available on Xe-2 and Xe-3 models |
| Water Spray | Programmable pure-water spray (optional, operable in light/dark cycles) |
| Filter Options | Daylight (F/Q/B), Window Glass (Q/B/SL/SF-5/IR), Extended UV (Q/B, Quartz) |
| Sample Mounting | Flat-bed (Xe-1/Xe-3) or Rotating Vertical Drum (Xe-2) |
| Compliance | Preconfigured test protocols for ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, IEC 60068-2-9, GMW 14124, VW PV 3929, and others |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-1 / Xe-2 / Xe-3 |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Duration | 1–9999 h (continuously adjustable) |
| Humidity Range | 20–95% RH (model-dependent) |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Filter Options | Daylight, Window Glass, Extended UV |
| Black Panel Temperature Range | 45–120 °C (varies by model and filter) |
| Sample Capacity | Up to 55 specimens (Xe-3 HD/HS models) |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, IEC 60068-2-9, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Radiation Intensity | ≤1800 W/m² |
| Light Exposure Cycle | 1–9999 h, continuously adjustable |
| Humidity Control Range | 10–95% RH (model-dependent) |
| Cooling Method | Air-cooled xenon lamps |
| Lamp Life | ~1500 hours |
| Compliance | ASTM G151, G154, ISO 4892-2, SAE J2412, IEC 60068-2-5, FDA 21 CFR Part 11 (software-enabled configurations), GLP/GMP-ready audit trails |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Series |
| Pricing | Available Upon Request |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-1 / Xe-3 / B02 |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 85 °C (operational, dependent on irradiance and humidity settings) |
| Humidity Range | 10–95% RH (controlled, model-dependent) |
| Lamp Life | ~1500 hours |
| Cooling Method | Air-cooled |
| Filter Types | Daylight, Window Glass, Extended UV |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Xenon Lamp Power | 1.8 kW |
| Irradiance Range | 0.25–1.3 W/m² (at 340 nm) |
| Light Cycle | Programmable |
| Humidity Range | 10–95% RH |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN Series (Xe-1, Xe-2, Xe-3) |
| Xenon Lamp Power | 1800 W |
| Irradiance Control | 1.3 W/m² @ 340 nm |
| Max Exposure Duration | 1500 h per cycle |
| Humidity Range | Up to 95% RH |
| Compliance | GB/T 1865–2009 Cycle A Method 1 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-SUN® Xe-8 |
| Price | Upon Request |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Lifetime | 1500 hours |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 15 pieces of 51 mm × 102 mm |
| Black Panel Temperature Range | 35–103 °C |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Filter Options | Daylight-Q / Daylight-B/B, Window-Q / Window-B/SL / Window-IR, Extended UV-Q/B |
| Cooling | Ambient air-cooled (optional refrigerated cooling unit available) |
| Interface | Ethernet-enabled touchscreen controller with self-diagnostic alerts |
| Compliance | Designed to support ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, and other xenon arc weathering standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Xenon Lamp Power | 1800 W |
| Lamp Cooling | Air-cooled |
| Lamp Lifetime | ~1500 hours |
| Filter Options | Daylight-F / Daylight-Q / Daylight-B/B / Window-Q / Window-B/SL / Window-SF-5 / Window-IR / Extended UV-Q/B |
| Sample Mounting | Horizontal flat tray |
| Chamber Type | Benchtop |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Xenon Lamp Power | 1800 W |
| Chamber Type | Benchtop |
| Light Source | Single Xenon Arc Lamp |
| Optical Filtering | Q-SUN Xe-1-B (Daylight), Optional Xe-1-S (with Water Spray), Xe-1-BC (with Chiller), Xe-1-SC (with Spray + Chiller) |
| Control Interface | Touchscreen with 5-language support (English, French, Spanish, Italian, German) |
| Connectivity | Built-in Ethernet |
| Compliance | Designed to meet ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, and other xenon arc exposure standards |
| Calibration | PATENTED AUTOCAL System for rapid irradiance calibration |
| Maintenance | Filter-free optical system |
| Dimensions | Compact benchtop footprint (exact dimensions available upon request) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-1 |
| Xenon Lamp Power | 1800 W |
| Dimensions (Sample Tray) | 251 mm × 457 mm |
| Max Sample Capacity | 17 pcs of 51 mm × 102 mm |
| Lamp Type | Air-Cooled Xenon Arc Tube |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE Spectral Radiometer (340 nm, 420 nm or TUV) |
| Temperature Control | Black Panel Thermometer (35–103 °C), optional Air Temperature Sensor |
| Optional Accessories | Water Spray System (Xe-1-S/Xe-1-SC), Refrigerated Cooling Unit (Xe-1-BC/Xe-1-SC) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1-B |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 35–103 °C |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | fifteen 51 mm × 102 mm specimens |
| Filter Options | Daylight-Q / Daylight-B/B, Window-Q / Window-B/SL / Window-IR, Extended UV-Q/B |
| Cooling Option | Optional refrigerated cooling unit |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-1-B |
| Xenon Lamp Power | 1800 W |
| Black Panel Temperature Range | 35–103 °C |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | fifteen 51 mm × 102 mm specimens |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Filter Options | Daylight-Q, Window-Q, Window-IR (replaceable) |
| Cooling | Optional refrigerated cooling unit |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, IEC 60068-2-9 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1-BC |
| Cooling Option | Integrated Refrigeration System |
| Light Source | Air-Cooled Xenon Arc Lamp (1500 h typical life) |
| Irradiance Control | SOLAR EYE Spectral Radiometer (340 nm, 420 nm or TUV) |
| Temperature Control | Black Panel Thermometer (35–103 °C), optional Air Temperature Sensor |
| Sample Tray | 251 mm × 457 mm, accommodates up to fifteen 51 mm × 102 mm specimens |
| Filter Options | Daylight, Window Glass, Window-IR (replacement required) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, IEC 60068-2-9 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-1-BC |
| Xenon Lamp Power | 1800 W |
| Temperature Range | 19–103 °C (with integrated refrigeration system) |
| Humidity Control | Relative Humidity (RH) monitoring and regulation standard |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV) |
| Cooling System | Permanent built-in refrigeration unit |
| Lamp Type | Air-cooled full-spectrum xenon arc lamp |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-1-S |
| Xenon Lamp Power | 1800 W |
| Lamp Type | Air-Cooled Single Xenon Arc Lamp |
| Lamp Lifetime | 1500 hours |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 15 pcs of 51 mm × 102 mm specimens |
| Irradiance Control | SOLAR EYE® Spectral Radiometer (340 nm, 420 nm or TUV) |
| Temperature Monitoring | Black Panel Thermometer (35–103 °C), optional Air Temperature Sensor |
| Humidity Control | Optional Water Spray System (deionized water required) |
| Filter Options | Daylight, Window Glass, Window IR (replacement required) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2 |
| Interface | Built-in Ethernet, Touchscreen UI, Auto-Diagnostic Alerts |
| Calibration | AUTOCAL® System, CR20 Radiometer & CT202 Thermometer Support |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1-S |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Life | 1500 hours |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 15 pieces (51 mm × 102 mm) |
| Irradiance Control | SOLAR EYE® Sensor (340 nm, 420 nm or TUV band) |
| Temperature Control | Black Panel Thermometer (35–103 °C), optional Air Temperature Sensor |
| Humidity Simulation | Optional Water Spray System (purified water required) |
| Filter Options | Daylight, Window Glass, Window-IR (replacement required) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, GB/T 16422.2 |
| Interface | Built-in Ethernet, Touchscreen UI, Self-Diagnostic Alerts |
| Calibration | AUTOCAL® System, CR20 Radiometer & CT202 Thermometer Support |
| Cooling | Optional Refrigerated Chiller for Low-Temperature Operation |
| Mounting | Horizontal Sample Orientation |
| Power Supply | Standard 120/240 V AC |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-1-SC |
| Xenon Lamp Power | 1800 W |
| Temperature Range | 19–103 °C (with chiller option) |
| Humidity Control | Optional |
| Water Spray System | Integrated dual-nozzle spray, programmable in light/dark cycles |
| Lamp Type | Air-cooled single xenon arc lamp |
| Lamp Lifetime | ~1500 hours |
| Spectral Output | Full-spectrum solar simulation (UV–VIS–NIR) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-1-SC |
| Lamp Type | Air-Cooled Single Xenon Arc Lamp |
| Lamp Life | 1500 hours |
| Irradiance Control | SOLAR EYE® Spectral Radiometer (340 nm, 420 nm, or TUV) |
| Filter Options | Daylight-Q / Daylight-B/B, Extended UV-Q/B, Window-Q / Window-B/SL / Window-IR |
| Sample Tray Dimensions | 251 mm × 457 mm |
| Max Sample Capacity | 15 pcs of 51 mm × 102 mm specimens |
| Black Panel Temperature Range | 35–103 °C |
| Optional Chiller | Integrated refrigeration unit enabling operation down to 19 °C |
| Water Spray System | Dual-nozzle, programmable during light/dark cycles, requires purified water |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-2 |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 90 °C (operational, typical) |
| Humidity Range | 10–95% RH (non-condensing, controlled) |
| Sample Mounting | Rotating Drum |
| Optional Features | Humidity Control, Water Spray (Front/Back), Black Panel Thermometer (BPT), Black Standard Thermometer (BST) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-2-H |
| Lamp Power | 1800 W (air-cooled xenon lamp) |
| Temperature Range | Ambient to 90°C (chamber air) |
| Humidity Range | 10–95% RH (controlled) |
| Black Panel Temperature Range | 35–110°C |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, AATCC TM169, ISO 105-B02, IEC 60068-2-9, JIS D 0205, GB/T 16422.2 |
| Software Interface | Multi-language (English, French, Spanish, Italian, German) with Ethernet data logging |
| Calibration Support | NIST-traceable CT202 black panel thermometer & CR20 radiometer |
| Lamp Life | ~1500 hours |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB Xe-3 |
| Cooling Type | Air-Cooled |
| Lamp Configuration | 3 x Xenon Arc Lamps |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE Spectral Radiometer (340 nm, 420 nm, or TUV) |
| Temperature Range | 31–120 °C (with chiller option) |
| Humidity Range | 10–95% RH (controlled) |
| Sample Capacity | Up to 51 specimens (51 mm × 102 mm) on 451 mm × 718 mm tray |
| Filter System | Triple-filter assembly (e.g., Daylight-Q/B, Window-Q, Window-IR) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, J2412, AATCC TM16, GB/T 16422.2 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-3 |
| Xenon Lamp Power | 1800 W |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Lamp Configuration | 3 air-cooled xenon arc lamps |
| Lamp Lifetime | 1500 hours |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 42–120 °C |
| Relative Humidity Control | Standard (requires purified water) |
| Optional Features | Water spray (top), dual spray, back spray, refrigerated cooling unit (Xe-3-HSC), Window-IR filter (replaceable), multi-language controller (English, French, Spanish, Italian, German) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-LAB Xe-3 |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 90 °C (Black Panel), Air Temperature up to 80 °C |
| Humidity Range | 10–95% RH (non-condensing), programmable via PID control |
| Optional Functions | Water Spray, Dual Spray, Back Spray, Refrigerated Cooling Unit |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-LAB Xe-3 |
| Xenon Lamp Power | 1800 W |
| Temperature Range | Ambient to 85 °C (operational, controlled) |
| Humidity Range | 10–95% RH (non-condensing, programmable) |
| Lamp Configuration | Three air-cooled xenon arc lamps |
| Lamp Life | Approx. 1500 hours |
| Sample Tray Dimensions | 451 mm × 718 mm (slide-out design) |
| Optional Functions | Single spray, dual spray, back-spray, low-temperature operation |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-3 |
| Lamp Power | 1800 W |
| Lamp Configuration | Triple-air-cooled xenon arc lamps |
| Sample Tray Dimensions | 451 mm × 718 mm (sliding drawer design) |
| Humidity Control | Integrated RH control (range: 10–95% RH, non-condensing) |
| Water Spray Options | Standard front spray, optional dual-spray (secondary fluid), back-spray, and low-temperature operation |
| Compliance | Designed to support ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, and other international weathering standards |
| Software Interface | Q-Lab’s proprietary Windows-based SunTest software with audit trail, user access levels, and data export (CSV, PDF) |