- All
- Favorite
- Popular
- Most rated
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-WOT100 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Sample Injection Volume | 0.5–20.0 mL (recommended: 5.0 mL) |
| Measurable TOC Range | 0–100 mg/L |
| Repeatability Error | ≤3% (at 50% of full scale per JJG 821–2005) |
| Accuracy (TC) | ±5% |
| (IC) | ±4% (at 20%, 50%, and 80% of full scale per JJG 821–2005) |
| Detection Limit | ≤25 ppb (per HJ 501–2009) |
| Dimensions | 550 × 450 × 530 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS02 |
| Pricing | Upon Request |
| Weight | 15 kg |
| Power Consumption | 1 kW |
| Input Voltage | AC 220 V / 50 Hz |
| Sealing Cycle Time | < 10 s |
| Warm-up Time | < 2 min |
| Heating Temperature Range | 150–200 °C (adjustable) |
| Dimensions (W × D × H) | 380 × 350 × 245 mm |
| Display | 5-inch TFT LCD touchscreen |
| UV Sterilization | Integrated germicidal UV-C lamp (254 nm) |
| Sealing Mechanism | Pneumatically assisted upward-pressing thermal sealing |
| Maintenance Access | Top-hinged service panel |
| Drainage | Spring-loaded pop-up drip tray |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTY-UVB01 |
| UV Wavelengths | 254 nm (short-wave) & 366 nm (long-wave) |
| Lamp Voltage | 50 V ± 10 V |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (L×W×H) | 320 × 240 × 320 mm |
| Weight | 3.8 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Design Features | Integrated UV housing with magnetic sample door, dual-side access ports, UV-shielded operation |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ASE-70A |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 70 vials per run |
| Dimensions (W × D × H) | 300 mm × 520 mm × 450 mm |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Operation Modes | Analyzer-Synchronized (Online) & Time-Based (Scheduled) |
| Bottle Detection | Integrated optical/vacuum-sense auto-detection |
| Position Feedback | Real-time bottle-position display with auto-reset function |
| Maintenance Requirement | Minimal routine maintenance |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-S100 |
| Price | Upon Request |
| Water Processing Capacity | 10 L per cycle |
| Pretreatment Time | ≤15 min |
| Touchscreen Interface | 7-inch foldable color LCD |
| Sample Loading | Motorized or manual |
| Power Consumption | ≤300 W |
| Unit Weight | 18 kg |
| Settling Timer Range | 0–99 h |
| Turbidity Sensor Range | 0–200 NTU |
| Pressure Sensor Range | 0–2.0 MPa |
| Stirring Speed Range | 0–1500 rpm |
| Disinfection Method | Integrated UV-C lamp (254 nm) |
| pH Sensor Range | 0–14 |
| Parallel Operation | Up to 8 units via master-slave configuration |
| Average Protozoan Recovery Efficiency | >35% (per ASTM D5421 / ISO 15553 validated methodology) |
| Workflow Customization | User-defined SOPs with real-time status alerts and auto-halt on anomaly detection |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.500 mg/L |
| Accuracy | ±3% |
| Resolution | 1 ppb |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤±3% |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ASE-24 |
| Pricing | Upon Request |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 24 vials per cycle |
| Dimensions | 380 × 320 × 340 mm |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DC200 / DC200e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.030–2000 ppb |
| Accuracy | ±0.1 ppb (0.100–1.99 ppb, water resistivity >15 MΩ·cm) |
| Detection Limit | 0.030 ppb |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | SSE-10000 |
| Maximum Sample Carbon Load | 0.1–30.0 mg C |
| Sample Form Compatibility | Solid and Liquid |
| Oxidation Efficiency | ≥99% |
| Repeatability (RSD) | ≤5% |
| Dimensions | 800 × 310 × 270 mm |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ASE-18C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 18 vials per cycle |
| Dimensions | 380 × 320 × 340 mm (W × D × H) |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Operating Modes | Analyzer-Synchronized (Online) Mode & Time-Based (Scheduled) Mode |
| Bottle Detection | Integrated optical/vacuum-based presence sensing |
| Maintenance Requirement | Minimal |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-F100 |
| Power Supply | AC 220 V / 50 Hz |
| Maximum Sample Volume | 0–9999 L |
| Filtration Material | 316L Stainless Steel + Titanium Alloy Filter Discs |
| Touchscreen Interface | 7-inch Foldable Color LCD |
| Concentration Flow Rate | 0–2.2 L/min (adjustable) |
| Filter Cartridge Actuation | One-Touch Electric Control |
| Rated Power | ≤200 W |
| Net Weight | 15 kg |
| Pressure Sensor Range | 0–2.0 MPa |
| Sterilization Methods | Chemical Disinfectant Rinse / Moist Heat Sterilization |
| Membrane Replacement Alert | Automatic Notification |
| Channel Scalability | Up to 8 Units in Parallel Configuration |
| Average Recovery Efficiency | >35% (Cryptosporidium oocysts & Giardia cysts, per EPA Method 1623.1/ISO 15553) |
| Workflow Customization | User-Defined SOP Sequencing, Adjustable Sample Volume Input, Real-Time Status Alerts & Emergency Stop Functionality |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HTY-GM2000 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.000–20.000 mg/L |
| Repeatability | ≤3% |
| Sample Volume Requirement | 12 mL per analysis |
| Analysis Time | ≤20 min per sample |
| Detection Limit | <10 µg/L |
| IC Range | 0.000–5.000 mg/L |
| Accuracy (Indicated Value Error) | ±5% |
| Injection Speed | 0.6 mL/min |
| Dimensions | 480 × 300 × 540 mm |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Origin | Domestic (China) |
| Model | 51-Well / 97-Well MPN Quantitative Tray |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation |
| Detection Range | 0.000–1000.0 µg/L |
| Repeatability | ≤2% (per JB/T 20178–2017) |
| Accuracy | ±5% (per JJG (Zhejiang) 98–2007) |
| Recommended Sample Conductivity | 0–5.1 µS/cm @ 25 °C |
| Analysis Time | 4 min |
| Sample Flow Rate | 0.5 mL/min |
| Dimensions | 400 × 300 × 300 mm |
| User Interface | Full-touchscreen LCD |
| Security | Multi-level password access control |
| Alarm Function | Audible alert upon exceeding user-defined TOC upper limit |
| Optional Accessory | Modular autosampler compatibility |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic (China-Made) |
| Model | CDR-01 Enzyme-Substrate Reagent |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | AH-22-T |
| Pricing | Upon Request |
| Sample Chamber Volume | 0.1 mL |
| Throughput | 3 samples per run |
| Focusing Method | Auto-focus / Manual focus |
| Identifiable Taxa | ≥80 common algal genera and species |
| Imaging Sensor | 5 MP CMOS camera |
| Species Recognition Accuracy | ≥90% |
| Pixel Resolution | < 0.3 µm/pixel |
| Full-field Scan Mosaic Imaging | Supported |
| Compliance | HJ 1295–2023, HJ 1296–2023, HJ 1216–2021, HJ 1215–2021, SL 733–2016, and related freshwater periphyton & phytoplankton monitoring technical specifications |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | QYP Series Sterile Sampling Bottles |
| Pricing | Available Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | HTY-QTS02L |
| Pricing | Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Sealing Speed | ≤9 s per sample |
| Rated Power | 450 W |
| Preheating Time | ≤4 min |
| Weight | 8.5 kg |
| Ambient Temperature Limit | ≤40 °C |
| Operating Temperature Range | 5–45 °C |
| Operating Relative Humidity | ≤75 % RH |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS01 |
| Pricing | Upon Request |
| Operating Voltage | 220 V ±10% |
| Preheat Time | <15 min |
| Ambient Operating Temperature | −10 °C to 50 °C |
| External Housing Temperature | <40 °C |
| Dimensions (W×D×H) | 390 × 300 × 270 mm |
| Weight | 19 kg |
| Noise Level | <50 dB(A) |
| Compatible With | 51-well and 97-well Quanti-Tray®-style trays |
| Includes | MPN lookup tables (51- and 97-well), silicone sealing gasket |
| Maintenance | Front-access service door for routine cleaning and component inspection |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-ESAC100 |
| Pricing | Upon Request |
| Illumination Source | Shadow-Free White LED Light Source |
| Detection Method | High-Resolution Digital Camera + AI-Powered Image Recognition Algorithm |
| Interface | USB-A |
| Special Function | Auto-Dilution Mode Support |
| Identification Speed | <10 seconds per quantitative tray |
| Operating Ambient Temperature | 0–45 °C |
| Dimensions (W×D×H) | 380 × 243 × 364 mm |
| Weight | 12 kg |
| Power Supply | AC 220 V ±10% |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Enzyme-Substrate-Based Total Colony Count Detection Kit |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SWS Series Sterile Water Sampling Bags |
| Pricing | Available Upon Request |
| Volume Options | 100 mL, 250 mL, 500 mL |
| Sterilization Method | Gamma Irradiation |
| Packaging | Individual Sterile Peel-Pouch |
| Membrane Structure | Triple-Layer Laminated Film (PET/AL/PE) |
| Closure | Integrated Single-Use Snap Lock Cap |
| Sodium Thiosulfate Option | Available (1.8 mg/bag, pre-loaded for chlorine neutralization) |
| Compliance | Meets ISO 19458:2006 (Water quality — Requirements for sterile sampling containers), USP <61> Microbial Enumeration Tests, and EPA Method 1603 (E. coli in water) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HTY-APM100 |
| Pricing | Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GM200 / GM200e |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| TOC Range | 0.000–30.000 mg/L |
| IC Range | 0.000–5.000 mg/L |
| Repeatability Error | ≤2% (per JB/T 20178–2017) |
| Max. Permissible Error | TC ±5%, IC ±4% (per JJG 821–2005) |
| Analysis Time | 2.5 min |
| Dimensions | 400 mm × 400 mm × 200 mm |
| Ingress Protection | IP65 |
| Data Integrity | Audit Trail Enabled |
| User Access Control | Four-Tier Password Authentication |
Show next