- All
- Favorite
- Popular
- Most rated
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-WOT100 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Sample Injection Volume | 0.5–20.0 mL (recommended: 5.0 mL) |
| Measurable TOC Range | 0–100 mg/L |
| Repeatability Error | ≤3% (at 50% of full scale per JJG 821–2005) |
| Accuracy (TC) | ±5% |
| (IC) | ±4% (at 20%, 50%, and 80% of full scale per JJG 821–2005) |
| Detection Limit | ≤25 ppb (per HJ 501–2009) |
| Dimensions | 550 × 450 × 530 mm |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HTY-QTS02 |
| Pricing | Upon Request |
| Weight | 15 kg |
| Power Consumption | 1 kW |
| Input Voltage | AC 220 V / 50 Hz |
| Sealing Cycle Time | < 10 s |
| Warm-up Time | < 2 min |
| Heating Temperature Range | 150–200 °C (adjustable) |
| Dimensions (W × D × H) | 380 × 350 × 245 mm |
| Display | 5-inch TFT LCD touchscreen |
| UV Sterilization | Integrated germicidal UV-C lamp (254 nm) |
| Sealing Mechanism | Pneumatically assisted upward-pressing thermal sealing |
| Maintenance Access | Top-hinged service panel |
| Drainage | Spring-loaded pop-up drip tray |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Honeycomb Cell Culture System |
| Pricing | Upon Request |
| Temperature Control Range & Accuracy | RT+5°C to 50°C (±0.2°C) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0%–20% |
| Chamber Capacities | 30 L, 60 L, 100 L |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HTY-ADS01 |
| Pricing | Available Upon Request |
| Weighing Range | 0–1000 g |
| Max. Bag Weighing Capacity | 0–2000 g |
| Weighing Accuracy | ±0.1 g |
| Dilution Factor Range | 1–999 |
| Dilution Accuracy | >98% |
| Power Supply | AC 220 V ± 22 V, 50 Hz |
| Dimensions (W×D×H) | 38 × 24 × 28 cm |
| Net Weight | 13 kg |
| Dispensing Modes | Proportional / Weight-Triggered / Handheld Pipette |
| Dilution Time per Sample | <15 s |
| Pump Options | Pump A / Pump B / Dual-Pump (A+B) |
| Operating Modes | Standard / Rapid |
| Integrated Balance | Yes |
| Handheld Dispenser Included | Yes |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HTY-763 |
| Power | 400 W |
| Weight | 7.3 kg |
| Speed Range | 1,000–20,000 rpm |
| Timer Range | 1–300 s |
| Dimensions (L×W×H) | 200 × 244 × 206 mm |
| Homogenization Vessel Capacity | 300 mL / 500 mL |
| Display | 3.5-inch color LCD |
| Housing Material | Electropolished stainless steel |
| Thermal Protection | Integrated overtemperature cutoff |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | HTY-303G |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Noise Level | ≤60 dB(A) under load |
| Pump Flow Rate | ≥1.2 L/min |
| Dimensions (W×D×H) | 360 × 230 × 100 mm |
| Housing Material | 304L Stainless Steel |
| Filtration Configuration | Triple-head membrane filtration system with independent manual ball-valve control per channel |
| Integrated Pumps | Two high-performance diaphragm liquid pumps |
| Sterilization Compatibility | Pump heads autoclavable at 121 °C (wet heat) |
| Compatible Consumables | F47, F47B, F60, and S60 series filter cups |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HTY-V150 |
| Quotation Range | USD 14,000–70,000 |
| Air Flow Rate | 20 m³/h |
| Sterilization Volume Capacity | ≤150 m³ |
| Vaporization Temperature | ≤100 °C |
| Dehumidification Target RH | <85% |
| Filtration Efficiency | 99.99% (HEPA H14) |
| Sterilant | 35% Food-Grade Hydrogen Peroxide Solution |
| Microbial Log Reduction | ≥6-log (Geobacillus stearothermophilus spores) |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | Microbial Detection Membrane Filter |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Ferret Isolator |
| Pricing | Available Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | HTY-306G |
| Pricing | Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Model | HTY-HK Series |
| Measurement Principle | UV Absorption Spectroscopy (Dual-Wavelength, H₂O₂- and H₂O-Selective) |
| H₂O₂ Range | 200–50,000 ppm (field-adjustable) |
| H₂O Range | 200–250,000 ppm (field-adjustable) |
| H₂O₂ Detection Limit | 100 ppm |
| H₂O Detection Limit | 100 ppm |
| H₂O₂ & H₂O Repeatability | ≤5% RSD |
| Linearity Error | ≤±5% FS |
| Response Time | 1 s (configurable down to 0.1 s per measurement) |
| Operating Temperature | +5 °C to 300 °C |
| Pressure Range | 200 Pa to 0.2 MPa (vacuum to positive pressure) |
| Ambient Conditions | 0–40 °C, 0–85% RH |
| Output Signals | RS485 (Modbus RTU), 4–20 mA isolated analog |
| Certifications | CE Marked, ISO 9001:2015 Certified |
| Compliance | Designed for integration into ISO 14644-compliant cleanrooms and FDA-regulated sterilization validation workflows (supports 21 CFR Part 11 audit trail requirements when paired with compliant SCADA/HMI) |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Custom Configurable |
| Pricing | Upon Request |
| Brand | Tailin Bio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Live-Cell Imaging System |
| Pricing | Available upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HTY-ACB03 |
| Pricing | Upon Request |
| Material | 316L Stainless Steel |
| Dimensions (W×D×H) | 22.5 × 40.0 × 11.2 cm |
| Height of Suspension Assembly | 43 cm |
| Plunger Rod Length | 27 cm |
| Weight | 5 kg |
| Sample Holder Compatibility | Adjustable slot for multiple aerosol container sizes |
| Sterilization Compatibility | Wet-heat sterilizable (121°C, 30 min) |
| Regulatory Alignment | Designed per Chinese Pharmacopoeia (ChP) 2020 Edition General Chapter 1101 (Sterility Testing) and 1105 (Microbial Limits Testing) |
| Brand | TECHLEAD® |
|---|---|
| Manufacturer | Tailin Biotechnology Co., Ltd. |
| Origin | Zhejiang, China |
| Model | AST-300 |
| Type | Fully Automated Sterility Testing Incubation & Detection System |
| Regulatory Alignment | USP <1223>, EP 5.1.6, ChP 2020 <9201>, FDA 21 CFR Part 11 |
| Temperature Control Zones | Three independent incubation chambers (30–37 °C and 20–25 °C) |
| Detection Time | As low as 8 hours for positive identification |
| Detection Limit | ≤5 CFU per test unit |
| Microbial Coverage | Bacteria, yeasts, and molds |
| Data Integrity | Audit-trail enabled, electronic signature compliant, ALCOA+ principles implemented |
| Method Compatibility | Direct inoculation method |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTY-UVB01 |
| UV Wavelengths | 254 nm (short-wave) & 366 nm (long-wave) |
| Lamp Voltage | 50 V ± 10 V |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤75% RH |
| Dimensions (L×W×H) | 320 × 240 × 320 mm |
| Weight | 3.8 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Design Features | Integrated UV housing with magnetic sample door, dual-side access ports, UV-shielded operation |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MD500 / MD500e Offline |
| Instrument Type | Fully Automated |
| Detection Scope | Relatively Pure Aqueous Samples in All Microbial Control Scenarios |
| Measurement Range | 0–10,000 AFU/mL |
| Detection Limit | 1 AFU (Auto-Fluorescence Unit) |
| Analysis Mode | Continuous Operation |
| Flow Rate | 3–15 mL/min |
| Channel Capacity | 1–10 Built-in Channels (Expandable to 100) |
| Inlet/Outlet Connection | 1/8″ OD (3.2 mm) |
| Dimensions | 38 cm × 44 cm × 31 cm |
| Minimum Detectable Particle Size | 0.5 µm |
| Response Time | 2 seconds |
| Sample Temperature Range | 5–99 °C |
| Operating Environment | 0–50 °C / ≤80% RH |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 15 kg |
| Brand | Tailin Biotechnology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Region | Domestic (China) |
| Model | HTY-H2 |
| Pricing | Available Upon Request |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 700 W |
| Temperature Range | 20–65 °C |
| Net Weight | 7 kg |
| Heating Chamber Dimensions | Ø12.5 × 11.5 cm |
| Overall Dimensions | 37.5 × 28 × 16 cm |
| Heating Modes | Dry Heat or Water Bath |
| Dual-Chamber Selectivity | Independent Left/Right Chamber Activation |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HTY-AW01-TH |
| Form Factor | Benchtop Laboratory Instrument |
| Measurement Principle | Dual-sensor Chilled Mirror + Capacitive Relative Humidity Detection with Active Temperature Control |
| Measurement Range | 0.000–1.000 a<sub>w</sub> |
| Accuracy | ±0.003 a<sub>w</sub> (typical), ±0.02 a<sub>w</sub> (per JJG(粤)52 metrological verification) |
| Resolution | 0.0001 a<sub>w</sub> |
| Repeatability | ≤5% RSD (per JJG(粤)52) |
| Equilibration Time | ≤30 min (dependent on sample matrix and temperature setpoint) |
| Temperature Control Range | 10–50 °C |
| Temperature Control Stability | ±0.2 °C |
| Sample Temperature Range | 10–50 °C (accuracy ±0.2 °C, resolution 0.01 °C) |
| Ambient Operating Conditions | 4–50 °C, 0–90% RH (non-condensing) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz |
| Power Consumption | ≤100 W |
| Sample Cup Capacity | 7 mL |
| Data Storage | ≥10 years (flash memory, timestamped entries including a<sub>w</sub>, sample temperature, equilibration time, date/time, operator ID, sensor status) |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ASE-70A |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Rated Power | 40 W |
| Sample Capacity | 70 vials per run |
| Dimensions (W × D × H) | 300 mm × 520 mm × 450 mm |
| Compatible TOC Analyzers | HTY-DI1000-PL, HTY-DI1500, HTY-GM2000, HTY-GM3000 |
| Operation Modes | Analyzer-Synchronized (Online) & Time-Based (Scheduled) |
| Bottle Detection | Integrated optical/vacuum-sense auto-detection |
| Position Feedback | Real-time bottle-position display with auto-reset function |
| Maintenance Requirement | Minimal routine maintenance |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MD500 / MD500e Online |
| Instrument Type | Fully Automated |
| Detection Target | Microorganisms and Inert Particles in Water |
| Sample Type | Relatively Pure Aqueous Streams in Microbial Control Environments |
| Detection Speed | Real-Time Continuous Monitoring |
| Measurement Range | 0–10,000 AFU/mL |
| Detection Limit | 1 AFU (Autofluorescence Unit) |
| Flow Rate | 3–15 mL/min |
| Inlet/Outlet Connection | 1/8″ OD (3.2 mm) |
| Analysis Mode | Continuous Operation |
| Dimensions (W×D×H) | 50 cm × 32 cm × 60 cm |
| Minimum Detectable Size | 0.5 µm |
| Response Time | 2 s |
| Sample Temperature Range | 5–99 °C |
| Ambient Operating Conditions | 0–50 °C / ≤80% RH |
| Power Supply | 100–240 VAC, 50/60 Hz, 5 A |
| Weight | 35 kg |
| Data Communication | 4–20 mA Analog Output (Standard), Configurable Range |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | HTY-610 |
| Pricing | Upon Request |
| Power Supply | 95–260 VAC, 50–60 Hz |
| Rated Power | 120 W |
| Speed Range | 0–240 rpm |
| Weight | 11 kg |
| Total Suspension Height | 43 cm |
| Dimensions (W×D×H) | 22.0 × 30.0 × 11.0 cm |
| Control | Digital Pulse Motor Drive |
| Speed Regulation | Stepless (Infinitely Variable) |
| Torque Stability | Constant Across Full Speed Range |
| Safety Features | Pump Head Overload Protection, Waterproof Footswitch Interface |
| Tube Handling | Linear Tubing Insertion, Manual Clamp Mechanism |
| Memory Function | Last-Used Speed Retention |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HTY-300 |
| Weight | 3.5 kg |
| Filter Cup Compatibility | F47 / F47-R250 |
| Filter Membrane Diameter | 47 mm |
| Dimensions (L×W×H) | 37 × 12.5 × 10.5 cm |
| Sterilization | Autoclavable (wet-heat), flame-sterilizable pump heads |
| Operation Mode | Manual, independent three-channel control |
| Pump Head Design | Fixed (non-removable), continuous-use rated |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-GCC-S100 |
| Price | Upon Request |
| Water Processing Capacity | 10 L per cycle |
| Pretreatment Time | ≤15 min |
| Touchscreen Interface | 7-inch foldable color LCD |
| Sample Loading | Motorized or manual |
| Power Consumption | ≤300 W |
| Unit Weight | 18 kg |
| Settling Timer Range | 0–99 h |
| Turbidity Sensor Range | 0–200 NTU |
| Pressure Sensor Range | 0–2.0 MPa |
| Stirring Speed Range | 0–1500 rpm |
| Disinfection Method | Integrated UV-C lamp (254 nm) |
| pH Sensor Range | 0–14 |
| Parallel Operation | Up to 8 units via master-slave configuration |
| Average Protozoan Recovery Efficiency | >35% (per ASTM D5421 / ISO 15553 validated methodology) |
| Workflow Customization | User-defined SOPs with real-time status alerts and auto-halt on anomaly detection |
Show next