| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | 68601 (Mouse), 68602 (Rat) |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F660 |
| Price Range | USD 140 – 700 |
| Filtration Capacity | Fluosorber™ Sorbent Cartridge (Initial Mass: 1200 g |
| Replacement Threshold | ≥1400 g) |
| Absorbed Agents | Sevoflurane, Isoflurane, Halothane (CF₃CHClBr) |
| Not Absorbed | Nitrous Oxide (N₂O) |
| Flow Rate Range | 8–60 L/min |
| Noise Level | <20 dB(A) |
| Display | Color Touchscreen with Real-time Flow & Pressure Monitoring |
| Compliance | Designed for alignment with OSHA 1910.134, NIOSH REL (2 ppm TWA for isoflurane/sevoflurane), and institutional EH&S requirements |
| Brand | Smith |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APEX |
| Price | $1 (Reference Only) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 10–90% RH |
| Altitude Range | −400 to 3000 m |
| Dimensions (H×L×W) | 30.5 × 52 × 44.5 cm |
| Weight | 24 kg |
| Output Power | 7200 W continuous, 24,000 W peak |
| Output Voltage | 0–1200 VDC / 0–240 VRMS AC |
| Frequency Range | 1–1000 Hz |
| Waveforms | DC, Pulsed DC, Burst DC, AC |
| Onboard Data Logging | Peak/Avg Voltage, Current, Power, Waveform Parameters, GPS Coordinates, Timestamp, Internal Temperature, Altitude, Error Codes |
| Display | Sunlight-readable color LCD |
| Safety | Footswitch + Emergency Stop |
| Memory | 12 Predefined Waveform Profiles |
| Environmental Rating | IP54-equivalent enclosure for field use |
| Brand | BTX |
|---|---|
| Origin | United Kingdom |
| Model | F700 |
| Anesthetic Vaporizer | Imported precision vaporizer for isoflurane and sevoflurane |
| Animal Compatibility | Mice, rats, guinea pigs, and small rabbits |
| Oxygen Flush Rate | Up to 10 L/min |
| Anesthetic Concentration Range | 0–5% (adjustable in 0.1% increments) |
| Flowmeter Range | 1–4 L/min (configurable single/dual/penta-channel) |
| Circuit Type | Semi-closed and open systems |
| Exhaust Management | Active and passive scavenging options |
| Form Factor | Benchtop and mobile configurations |
| Standard Accessories | Anesthesia main unit, induction chamber, anesthesia tubing, CO₂ absorbent canister |
| Optional Accessories | Multi-channel flowmeters, rodent-specific masks (mouse/rat), large/small scavenging canisters, maintenance platform |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 8160B2K |
| Price Range | USD 2,800 – 7,000 |
| Control Interface | TFT LCD touchscreen (800×480 px, 65,536 colors, 500:1 contrast) |
| CO₂ Sensor Range | 0–99.9% vol |
| O₂ Sensor Range | 0–30.0% vol |
| Temperature Sensor Range | 0–50 °C |
| Humidity Sensor Range | 0–99.9% RH |
| Chamber Dimensions | 660 × 530 × 900 mm (L×W×H) |
| Viewing Window Area | 622 × 517 mm |
| Exhaust Duct | Ø40 mm flexible hose |
| Animal Capacity | 60–100 rats |
| Preloaded Protocols | Mouse, rat, guinea pig, rabbit euthanasia sequences |
| Custom Protocol Programming | Interactive GUI-based setup |
| Gas Inlet Silencer | Integrated acoustic dampening module |
| Data Logging | Real-time curve plotting & event timestamping via RS232/USB |
| Brand | EZ Vet |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ES9000 |
| Price Range | USD 700 – 1,400 |
| Brand | EZ Vet |
|---|---|
| Model | F500 |
| Animal Weight Capacity | ≤ 7.0 kg |
| Anesthetic Agents | Isoflurane and Sevoflurane compatible |
| Vaporizer Type | Precision calibrated, interchangeable dual-agent vaporizer |
| Safety Features | Agent lockout mechanism, large-view sapphire-reinforced glass gauge, coaxial scavenging-integrated breathing circuit |
| Form Factor | Benchtop (upgradable to mobile cart configuration) |
| Compliance | Designed per ISO 8536-4 (gas anesthesia equipment), meets GLP-aligned operational safety requirements for preclinical research environments |
| Price Range | USD 700 – 1,400 (FOB Beijing) |
| Brand | EZ Vet |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | F670 |
| Price Range | USD 140 – 700 |
| Flow Rate | 8–60 L/min |
| Filter Initial Mass | 1200 g |
| Replacement Threshold | ≥1400 g |
| Noise Level | <20 dB(A) |
| Compatible Anesthetics | Isoflurane, Sevoflurane, Halothane |
| Not Compatible | Nitrous Oxide (N₂O) |
| Display | Color Touchscreen with Real-Time Flow, Pressure & Mass Readout |
| Safety Alerts | Low-Pressure Alarm, Overweight Filter Alarm, One-Touch Mute Function |
| Regulatory Compliance | Designed for GLP-aligned laboratory environments |
| Brand | EZ Vet |
|---|---|
| Origin | Beijing, China |
| Model | F700 |
| Anesthetic Vaporizer | Imported calibrated isoflurane/sevoflurane vaporizer |
| Animal Weight Range | ≤ 7.0 kg |
| Compatible Species | Mice, rats, guinea pigs, rabbits, cats |
| Oxygen Flow Rate | 1–4 L/min (adjustable) |
| Rapid Oxygen Flush | 10 L/min |
| Anesthetic Concentration Range | 0–5% (v/v) |
| Circuit Type | Coaxial semi-closed rebreathing system |
| Exhaust Gas Management | Active and passive scavenging options |
| Configuration | Benchtop or mobile cart-mounted |
| Mask Interface | Species-specific face masks included |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ANESTHESIA |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mask Series (Canine, Feline, Rodent/Avian) |
| Pricing | Available Upon Request |
| Diaphragm Opening Diameter | 25 mm / 38 mm / 44 mm / 50 mm (varies by size) |
| Port ID | 11.9 mm / 15 mm |
| Material | Polycarbonate (mask body), Medical-Grade Rubber (diaphragm) |
| Sizes | Small, Medium, Large, Multi-Pack Kits |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-0001 |
| Gas Agent | Isoflurane |
| Carrier Gas | Oxygen |
| O₂ Inlet Pressure | 50 PSI (fixed) |
| O₂ Flow Range | 0–4 LPM (mechanically limited) |
| Max Safety Flow | 50 LPM (safety-limited bypass) |
| Vaporizer Range | 0.5–5.0% Isoflurane |
| CO₂ Absorber Capacity | 3 lb (reusable, removable) |
| Application Weight Limit | ≤136 kg (300 lb) |
| Compatibility | Rebreathing & Non-rebreathing Circuits |
| Integrable With | Veterinary Ventilators |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 2000 |
| Flow Range | 0.2–4 L/min (O₂) |
| Mounting | 5-Point Castor Base with MRI-Compatible Option Available |
| Compliance | FDA-Cleared Materials, ISO 13485–Aligned Manufacturing |
| Configuration Options | Single O₂, Dual O₂, O₂ + Air, O₂ + NO, MRI-Safe Variant |
| Standard Circuit | Jackson-Rees Non-Rebreathing (2 L bag, Cat. #72-3073) |
| CO₂ Absorption | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Surface Finish | Electrostatic Powder-Coated, Cleanroom-Compatible |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Range | CDS2000, CDS9000, Vaporstick Plus Desktop, Table Top Series |
| Flow Rate Range | 0.2–4 L/min (O₂), 0–1000 mL/min (auxiliary gases) |
| CO₂ Absorber Capacity | ≥900 mL (CDS9000) |
| Vaporizer Compatibility | ISO-standard 100-series isoflurane/sevoflurane vaporizers (e.g., Harvard 100 Series, Tech3/Tech4, Ohio) |
| Dimensions (CDS2000) | 133.35 cm H × 66.04 cm W (base diameter) |
| Dimensions (Desktop Models) | 30.48 cm W × 20.32 cm D × 38.1 cm H (Vaporstick Plus) |
| Regulatory Compliance | FDA-cleared materials, CE-marked, ISO 13485-manufactured, GLP-ready architecture |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range (O₂) | 0.2–4 L/min |
| Vaporizer | 100 Series Isoflurane Vaporizer (≥250 mL capacity, ±0.5% output accuracy) |
| CO₂ Absorbent Canister Volume | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Fresh Gas Outlet | Yes |
| Inhalation/Exhalation Ports (Closed-Circuit) | Yes |
| Pop-off Valve | Adjustable, provides continuous −2 cm H₂O baseline pressure for rebreathing bag |
| Oxygen Bypass Switch | Integrated |
| Construction | Anodized matte-finish aluminum chassis |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | f/air |
| Capacity | 50 g (halogenated anesthetic gases) |
| Dimensions | 15.2 cm H × 8.3 cm D (6 in × 3.25 in) |
| Active Sorbent Mass | 200 g |
| Usage | Single-use, non-reusable |
| Accessories | Tubing connector sold separately |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Tabletop |
| Flowmeter Options | 0.2–4 L/min O₂, 0–1000 mL/min O₂, Dual O₂ (0.2–4 L/min + 0–1000 mL/min), or O₂ + N₂O with Fail-Safe Valve |
| Dimensions (W×D×H) | 30" × 20" × 32.5" (762 × 508 × 825.5 mm) |
| Weight | 25 lb (11.34 kg) |
| Animal Capacity | Single subject up to 4.5 kg |
| Circuit Type | Non-rebreathing |
| Compatible Vaporizers | Tech3, Tech4, Ohio, and 100-series |
| CO₂ Absorber | Optional standalone unit (Part #723010) |
| Brand | Harvard Apparatus |
|---|---|
| Model | Tech3, 100 Series |
| Origin | USA |
| Fill Type | Funnel-Fill |
| Anesthetic Agents | Isoflurane, Halothane, Sevoflurane |
| Dial Settings | 0.5% and 1.0% increments |
| Inlet/Outlet Taper | 22–23 mm |
| Sump Capacity | 135 mL (35 mL absorbed by wick) |
| Dimensions (L × W × H) | 5.75 in × 5.25 in × 7.25 in |
| Weight | 1.5 lbs |
| Flow & Temperature Compensation | Yes |
| Sight Glass | Single |
| Manifold Design | Tapered, no check valve |
| Labeling | Color-coated agent-specific identification |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Vaporstick Anesthesia Machine |
| Flow Rate Range | 0.2–4 L/min (O₂) |
| Optional N₂O Flowmeter | Yes |
| Fail-Safe Valve | Included (Model 723009) |
| Mounting | Z-Bracket Universal Vaporizer Holder |
| Circuit Type | Non-rebreathing (Jackson-Rees, Mapleson D) |
| Upgradeable to Rebreathing | Yes (with external CO₂ absorber) |
| Frame | 5-Point Castor Base with MRI-Compatible Option |
| Construction | FDA-Approved Polymer Housing |
| Surface Finish | Electrostatic Powder Coating |
| Dimensions (H×W) | 134 cm × 152.4 mm |
| Weight Capacity | Up to 4.5 kg Animals |
| Exhaust Management | Active Scavenging-Compatible Pop-up Exhaust Valve |
| Fresh Gas Outlet | Dedicated Non-rebreathing Port |
| Absorber Design | Sealed Canister with Optimized Soda Lime Exposure Geometry |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HOPE-MED 8160B2K |
| Price Range | USD 2,800 – 7,000 |
| Brand | Hope-Med |
|---|---|
| Origin | Tianjin, China |
| Model | 8160B2K |
| Application | Non-pharmaceutical CO₂-based anesthesia and humane euthanasia for laboratory animals |
| Chamber Configuration | Dual-layer, high-capacity animal chamber |
| Control Mode | Pre-programmed automated sequence (acclimatization → anesthesia → euthanasia) |
| Gas Delivery | Precision-controlled CO₂ flow with real-time pressure monitoring |
| Compliance Context | Designed in alignment with AVMA 2020 Guidelines, NIH OLAW recommendations, and EU Directive 2010/63/EU on the protection of animals used for scientific purposes |
| Price Range | USD 2,800 – 7,200 (FOB Tianjin) |
| Brand | HOPE-MED |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HOPE-MED8160 |
| Price Range | USD 2,800 – 7,000 |
| Brand | Muromachi |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | MK-AL21D |
| Oxygen Flow Rate | 0.5–5 L/min |
| Vaporizer Capacity | 250 mL (max) |
| Adjustable Anesthetic Concentration Range | 0–5% (v/v) |
| Delivery Format | Benchtop, Key-Operated Fill System |
| Safety Compliance | Non-flammable anesthetic compatible (e.g., isoflurane, sevoflurane) |
| Brand | Braintree Scientific |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Quietek™ T Series (QTK-1, QTK-2, QTK-SC, QTK-SCT) |
| Pricing | Available Upon Request |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer | RWD Life Science Co., Ltd. |
| Type | Domestic |
| Model | RWD Series |
| Price Range | USD 1,400 – 2,800 |
| Weight Capacity | Up to 1 kg (rodents) and up to 100 kg (large animals) |
| Anesthetic Agents Supported | Isoflurane, Sevoflurane |
| Vaporizer Types | Pour-fill, Easy-fill, Key-fill |
| Induction/Recovery Time | 2–5 min |
| Waste Gas Scavenging | <9 s purge time |
| Ventilation Modes | VCV, PCV, APNEA |
| Integrated Tracheal Intubation System | Wireless fiber-optic illumination with non-thermal, low-stimulus light source |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer | RWD Life Science Co., Ltd. |
| Country of Origin | China |
| Model | RWD-AS200 |
| Price Range | USD 1,400 – 2,800 |
| Anesthetic Agents Supported | Isoflurane, Sevoflurane |
| Vaporizer Types | Pour-fill, Easy-fill, Key-fill |
| Induction/Recovery Time | 2–5 min |
| Induction Chamber Flush Time | ≤9 s |
| Simultaneous Animal Capacity | 2–5 rodents (mice/rats) |
| Maximum Animal Weight | 7 kg |
| Compatible Species | Mice, Rats, Hamsters, Guinea Pigs, Rabbits, Cats |
| Gas Pathway | Closed-loop Air/O₂ Delivery |
| Waste Gas Scavenging | Integrated Active Scavenging System |