BrandUIC (USA)
OriginUSA
ModelCM350
CategoryOther Elemental Analyzers
ComplianceASTM D3120, D3246, D5453
Detection PrincipleCoulometric titration based on Faraday’s law
Dynamic Range1 µg – 10,000 µg sulfur (equivalent to ~1 ppm – 100% w/w, sample-dependent)
Resolution0.01 µg S
Analysis Time5–7 min (combustion mode), ≤15 min (acid digestion mode)
Sample FormsSolids (0.5 mg – 10 g) and liquids
Furnace Max Temp1100 °C
Data StorageInternal floppy drive (CM5014S), exportable via RS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM120
Detection PrincipleHigh-Temperature Catalytic Combustion + Potentiometric CO₂ Detection
Measuring Range1–10,000 µg C per sample
Detection Limit0.01 µg C
Furnace Max Temperature1100 °C
Sample TypesSolids (soils, sediments, coal, sulfur, sludge) and Suspended-Particle Liquids
ComplianceASTM D7573, ISO 20236, USP <281>, EPA Method 415.1 compatible
Data StorageInternal memory + 3.5″ floppy disk drive
CalibrationFactory-calibrated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM120
Detection PrinciplePotentiometric CO₂ Titration
Temperature RangeUp to 1100 °C
Carbon Quantification Range1–10,000 µg absolute carbon
LinearityFull-scale 0–100% CO₂
Resolution0.01 µg carbon
Sample TypesSolids, liquids, slurries, heterogeneous waste, carbon-rich matrices
ComplianceDesigned for ASTM D7582, ISO 29541, USP <281>, and GLP-compliant workflows
Data StorageIntegrated SD card logging
Analysis Time5–7 min per sample
Interference rejectionPost-combustion scrubbers for SOₓ, NOₓ, H₂O, halides
Added to wishlistRemoved from wishlist 0
Add to compare
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMIPO5
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM140
ComplianceASTM D513
Detection PrinciplePotentiometric CO₂ detection after acidification
Dynamic Range1 µg C to 10,000 µg C (absolute)
Resolution0.01 µg C
Sample FormsSolid and liquid
Acid Digestion Volume Options10, 25, 50, or 100 mL
Analysis Time5–7 min typical
CalibrationFactory-calibrated
Data StorageInternal memory + 3.5" floppy disk
Software InterfaceStandalone instrument control with manual parameter entry
Added to wishlistRemoved from wishlist 0
Add to compare
OriginFrance
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMIPO5
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM340
Detection PrincipleCoulometric Titration (Faraday-based SO₂/H₂S Quantification)
Dynamic Range1 µg to 10,000 µg total sulfur
Resolution0.01 µg S
Sample FormsSolid and liquid
Acid Digestion Volume Options10, 25, 50, or 100 mL
Analysis Time~5–7 min per sample (temperature- and matrix-dependent)
Data StorageInternal memory for up to 50 samples + 3.5" floppy disk export
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model411
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM120
Detection PrincipleHigh-Temperature Catalytic Combustion + Potentiometric CO₂ Detection
Temperature RangeUp to 1100 °C
Carbon Range1 µg – 10,000 µg (0.1 ppm – 100 wt%)
Resolution0.01 µg absolute carbon
LinearityFull dynamic range without user calibration
Sample FormsSolids, slurries, particulate-laden liquids, powders, soils, sediments, coals, sulfurs
ComplianceASTM D7573, ISO 20538, USP <281>, EPA Method 9060A (adapted), GLP-ready audit trail support