- All
- Favorite
- Popular
- Most rated
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPD2.2 |
| Price Range | USD 27,000 – 68,000 |
| Compliance | ASTM E1226, ASTM E1515, EN 14034-1:2004+A1:2011, EN 14034-2:2006+A1:2011, EN 14034-3:2006+A1:2011 |
| Vessel Volume | 20 L |
| Vessel Material | AISI 316 Stainless Steel |
| Maximum Working Pressure | 40 bar (gauge) |
| Pressure Measurement Range | 0–25 bar (absolute) |
| (dp/dt)max Detection Threshold | >4000 bar/s |
| Kst Range | >1000 bar·m/s |
| Explosibility Parameters | LEL/UEL/MEC from 0 g/m³, LOC: 1–21 % O₂ |
| Dust Injection Valve Response Time | ≤30 ms |
| Vacuum Display Range | 0–1 bar (absolute) |
| Vacuum Control | Auto & Manual Modes |
| Vessel Temperature Monitoring | Front-panel digital readout |
| Data Acquisition Rate | 10–100 kHz |
| Software | ANKO Explosion Plotter v3.x (GLP-compliant reporting, audit trail, test sequence automation, noise-filtered signal processing, PDF report generation) |
| Accessories | Integrated vacuum pump unit, exhaust scrubber with flow controller, borosilicate observation viewport, dedicated workstation, thermal printer |
| Origin | Poland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIT3 |
| Price Range | USD 27,000 – 68,000 |
| Standards Compliance | EN 50281-2-1, ASTM E1491-06, IEC 61241-2-1, ISO/IEC 80079-20-2:2016 |
| Heating Range | Ambient to 1000 °C |
| Heating Element | Kanthal® alloy resistive heater |
| Chamber Construction | AISI 316 stainless steel |
| Dispersion Nozzle | ANKO-designed, geometry and orifice dimensions fully compliant with ISO/IEC 80079-20-2 |
| Temperature Control | Digital PID controller with ±1.5 °C stability over full range |
| Temperature Measurement | Calibrated ceramic-sheathed thermocouple (Type K), integrated LED digital display |
| System Configuration | Single-unit standard configuration |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LIT3 |
| Price Range | USD 27,000 – 68,000 |
| Standards Compliance | EN 50281-2-1, ASTM E2021, IEC 61241-2-1, ISO/IEC 80079-20-2:2016 |
| Heating Plate Material | Anodized Aluminum Alloy |
| Chamber Body Material | AISI 304 Stainless Steel |
| Temperature Sensors | Dual K-type Thermocouples (Heating Plate & Dust Layer) |
| Dust Ring Dimensions | Standard Ø100 mm, with optional heights of 5 mm, 12.5 mm, and 15 mm (custom heights available upon request) |
| Temperature Range | Ambient to 400 °C |
| Control Mode | PID-regulated Heating Plate Controller |
| Data Interface | USB 2.0 Serial Communication |
| Sampling Interval | Configurable from 1 second upward |
| Software | ANKO ReqTemp v3.2 Data Acquisition & Analysis Suite |
| Configuration | Single-unit Standard System |
| Origin | Poland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MINOR2 |
| Price Range | USD 27,000 – 68,000 (estimated FOB) |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HST100 |
| Price Range | USD 27,000 – 68,000 |
| Heating Method | Electrically Heated Aluminum Block |
| Sample Capacity | 21 Positions |
| Sample Tube Dimensions | Ø30 ±0.3 mm × 230 ±2 mm (Cylindrical, Round-Bottom, Glass Stopper) |
| Temperature Range | Ambient to 110 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Sensor | PT100 Probe |
| Over-Temperature Safety Cut-off | 120 °C |
| Controller | Dedicated PID Temperature Program Controller |
| Power Supply | 230 V / 50 Hz, 2400 VA |
| Illumination System | Specialized Fluorescent Lamp (Non-Glare, Optimized for NO₂ Vapor Detection) |
| Viewing Assembly | Rigid Adjustable Lamp Mount with UV-Enhanced Visible Spectrum Output |
| Display | Dual Digital Readout (Setpoint & Actual Temperature) |
| Sample Holder Depth | 170 mm |
| Sample Holder Diameter | 31 mm |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Koenen Test Apparatus |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | Methyl Violet Method |
| Temperature Range | 60–140 °C |
| Control Accuracy | ±0.1 °C |
| Sample Capacity | 24 positions (20.5 mm diameter × 280 mm depth) |
| Heating Block | Anodized aluminum with PID controller |
| Temperature Sensor | PT100 probe |
| Safety Features | Over-temperature cut-off, ISO-insulated housing |
| Power Supply | 230 V / 50 Hz, 1500 VA |
| Compliance | MIL-STD-286C (Sections 120 & 134.5), ISO 8765:2017 (Nitrocellulose stability testing) |
| Accessories | 24× cylindrical tubes (OD 20 mm, ID 17 mm, L 290 mm), vented cork stoppers, stainless steel hooks, methyl violet indicator paper (200 sheets/pack) |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SC-2 |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM Type |
| Price Range | USD 27,000 – 68,000 (FOB Hamburg) |
| Compliance | BAM Method 13.5.1 Test 3(b)(i), UN Manual of Tests and Criteria Part I, Section 10.3, EU Directive 2008/43/EC, ADR/RID/IMDG Code Annexes |
| Friction Stroke | 10 mm |
| Motor Drive Speed | 141 rpm |
| Load Range | 0.5–36 kg (5–360 N) via calibrated weights on 6-groove loading arm |
| Ceramic Components | Alumina ceramic rod (Ø10 × 15 mm), ceramic plate (25 × 25 × 5 mm), surface roughness Ra 9–32 µm |
| Standard Accessories | 1 cast-iron base plate, 1 loading arm with 6 grooves, 9 calibrated weights, 1 hook, 400 ceramic rods, 100 ceramic plates |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FLB2.0 |
| Price Range | USD 27,000 – 68,000 |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BB-12 |
| Price Range | USD 28,000 – 70,000 |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-2 |
| Price Range | USD 28,000 – 70,000 |
| Standard Compliance | VDI 2263 Part 1 Section 2.6.1.1, ASTM E1491-06 |
| Chamber Volume | 0.35 L |
| Max Operating Temperature | 600 °C |
| Power Supply | 110/230 V AC, 1200 W |
| Heating Element | Kanthal A1 wire in ceramic matrix |
| Temperature Sensors | Dual K-type thermocouples with Inconel sheaths and silicone-insulated leads |
| Dust Dispersion Nozzle | Precision-machined per ASTM E1491 specifications |
| Chamber Material | AISI 304 stainless steel |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MINOR 3.1 |
| Price Range | USD 27,000 – 68,000 (FOB) |
| Compliance Standards | EN 13281-1:2015, ASTM E2019-22, IEC 61241-2-3:2003, ISO/IEC 80079-20-2:2016 |
| Ignition Energy Range | 1–1000 mJ (standard), 2000–3000 mJ (optional) |
| Ignition Delay | 20–350 ms (adjustable in 1 ms increments) |
| Ignition Vessel | Hartmann-type glass tube (ID 30 mm, L 150 mm) |
| Control System | Microprocessor-based with LCD interface, real-time delay monitoring, energy activation feedback, and USB 2.0 data export |
| Calibration | Integrated pressure reference gauge for system integrity verification |
| Configuration | Single-unit standard configuration |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Beckmann-Junk Method |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM |
| Price Range | USD 27,000 – 68,000 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Model | A.21/O2 |
| Pressure Measurement Range | 690–2070 kPa (0–500 psi) |
| Response Time | ≤5 ms |
| Pressure Sensor Accuracy | ±0.2 ms timing resolution |
| Ignition Wire | NiCr, 25 cm length, Ø0.6 mm, 3.85 Ω/m |
| Burst Disc | Aluminum, 0.2 mm thickness, nominal burst pressure ≈ 320 psi |
| Ignition Power Supply | 10 A / 16 V constant current |
| Data Acquisition | Digital storage oscilloscope with PC interface and printer output |
| Remote Ignition Distance | ≥2 m (separate control box) |
| Compliance | UN Manual of Tests and Criteria, Rev. 7, Test 2(c)(i).2 |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AB140 |
| Price Range | USD 27,000 – 68,000 |
| Heating Block Material | Aluminum |
| Sample Capacity | 5 positions |
| Sample Tube Dimensions | Ø17.5 ± 0.1 mm × 70 mm depth (tube body) |
| Temperature Sensor | PT100 probe |
| Temperature Control | PID controller with independent control cabinet |
| Max Setpoint | 140 °C |
| Temperature Accuracy | ±0.1 °C |
| Power Supply | 230 V / 50 Hz, 300 VA |
| Safety Features | Over-temperature cut-off protection |
| Accessories Included | 5 calibrated cylindrical sample tubes (with three annular bands), perforated rubber stoppers, platinum-tipped glass rods, KI-starch test paper support fixture |
| Origin | Poland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FLA 2.1 |
| Price Range | USD 27,000 – 68,000 |
Show next