| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 1300 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C min) |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771–D5773, D97, D5950, D5853 |
| Optical Detection | Pulsed IR fiber-optic probe for cloud point |
| Mechanical Detection | Dual PT100 surface probes + motorized tilt arm for pour point |
| Brand | Linetronic |
|---|---|
| Origin | Switzerland |
| Model | 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage compressor (–85 °C min) or single-stage compressor (–40 °C min) |
| Temperature Sensor | PT100 Class A |
| Detection Method | Coaxial fiber-optic IR pulse reflection with mirror-based crystallization monitoring |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Software | LabLink v.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail capability |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300/2 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Dual-stage compressor |
| Temperature Sensor | PT100 Class A |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Standards Compliance | ASTM D97, D5950, D5853 |
| Sample Capacity | Dual PT100 surface probes, standardized test tube per ASTM/IP/ISO |
| Software | LabLink (Windows-compatible), supports up to 10 analysis heads, LIMS- and Excel-compatible data export, audit-trail-capable calibration logging |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 100 / D2500 |
| Temperature Range | +80 °C to –80 °C |
| Cooling System | Single-stage or dual-stage compressor |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe with silver-coated sample tube bottom |
| Temp. Resolution | 0.06 °C |
| Temp. Accuracy | ±0.1 °C |
| Compliance | ASTM D2500, D5771, D5772, D5773 |
| Software | LabLink (Windows-compatible, multi-head control up to 10 units) |
| Data Storage | >60,000 assays, Excel-exportable, LIMS-integrated |
| Dimensions (1-head) | 66 × 60 × 80 cm |
| Weight (1-head, single-stage) | 70 kg |
| Brand | Linetroic |
|---|---|
| Origin | Switzerland |
| Model | 200 CFPP |
| Compliance | ASTM D97, D5950, D5853 |
| Temperature Range | +80 °C to –90 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Single-stage or dual-stage compressor (–40 °C or –85 °C base cooling) |
| Sensor Type | PT100 Class A platinum resistance thermometers |
| Sample Capacity | Standardized test jar per ASTM/IP/ISO specifications |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model Series | 100 / 200 / 300 / 410 |
| Application Domain | Petroleum Low-Temperature Property Testing |
| Compliance Framework | ASTM D2500, D97, D5949, D6371 |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 300/410/2 |
| Standards Compliance | ASTM D1177, D97, D2386, D5901, D5972, D5853, D5950, IP16, IP441, IP528, IP529, ISO 3013, ISO 3016, GB/T 6537, SH/T 0770, GB/T 510 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling System | Dual-stage fluorine-free compressor, min. –85 °C |
| Temperature Sensor | Pt100 Class A |
| Optical Detection | Pulsed IR fiber-optic probe (freeze point) |
| Mechanical Detection | Dual PT100 surface probes + programmable tilt actuator (pour/pour point) |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Dimensions (W×D×H) | 66 × 60 × 80 cm (1-head) |
| Weight | 70 kg (1-head, single-stage), 80 kg (1-head, dual-stage), 90 kg (2-head, single-stage), 100 kg (2-head, dual-stage) |
| Software | LabLink v5.x (Windows 2000/XP/Vista), supports up to 10 analysis heads, LIMS-compatible, 21 CFR Part 11-ready audit trail, Excel-exportable data format (.csv/.xls), >60,000 result storage capacity |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 410/2 |
| Cooling Capacity | −85 °C (dual-stage compressor) |
| Temperature Range | +80 °C to −100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Detection Principle | Optical crystallization detection via coaxial IR fiber-optic probe and polished mirror surface |
| Temperature Sensor | PT100 Class A |
| Stirring System | Miniature motor-driven mechanical stirrer |
| Cooling System | Hermetic dual-stage refrigeration (R513A/R1234ze, fluorine-free) |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Safety Certifications | CE, integrated pressure controllers, thermal cut-offs, compressor overload protection |
| Software | LabLink v5.x (Windows 10/11 compatible), supports up to 10 analysis heads, 21 CFR Part 11–ready audit trail, LIMS integration, Excel-exportable data format (.csv, .xlsx) |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | NewLab 300 |
| Temperature Range | +80 °C to –80 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D97, D5950, D5853 |
| Detection Method | Dual PT100 surface probes with motorized sample tube tilting |
| Cooling System | Single-stage or dual-stage compressor options |
| Test Heads | 1 or 2 independent stations |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 410 |
| Freeze Point Range | +80 °C to –100 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D1177, D2386, D5901, D5972, D1655 |
| Measurement Principle | Coaxial pulsed IR spectroscopy with fiber-optic probe and reflective optical path |