Empowering Scientific Discovery

Beijing Daiso Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXTRA Oil-in-Water Analyzer
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSmart
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRivertrace
OriginUnited Kingdom
ModelSmart 50M
Measurement Range0–10 ppm (large cell) / 0–200 ppm (medium cell)
Accuracy±0.15 ppm (large cell) / ±2 ppm (medium cell)
Display Resolution0.1 ppm
Alarm SetpointsAdjustable (1–10 ppm or 10–200 ppm per cell)
Alarm Delay1–15 s (Alarm 1), 1–600 s (Alarm 2) with disable option
Output Signal4–20 mA
Sample Temperature+1 to +90 °C
Sample Flow Rate0.3–3 L/min
Sample Pressure0.1–10 bar
Ambient Operating Temperature+1 to +50 °C
Ambient Humidity≤80 % RH, non-condensing
Enclosure RatingIP55
Power Supply230 VAC, 50 Hz, 15 VA
Dimensions (W×D×H)500 × 360 × 150 mm
Weight15 kg
CertificationsGermanischer Lloyd (GL)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelOCD50
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM350
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleCoulometric Titration (Faraday-based SO₂/H₂S Detection)
Dynamic Range1 µg – 10,000 µg S per sample
Detection Limit~1 µg S (absolute)
Linear Range0.2% RSD or better for certified standards
Sample FormsSolids (0.5 mg – 10 g) and Liquids
Total Analysis Time5–7 min (combustion mode)
Combustion TemperatureUp to 1100 °C (dual-zone furnace)
Acid DigestionModified Monier-Williams method with programmable heating & gas purging
Data StorageInternal memory + 3.5″ floppy disk (CM5014S unit)
Compliance SupportASTM D3120, D3246, D5453
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCK
OriginUSA
ModelHC-404
Instrument TypeLaboratory Analyzer
PrincipleInfrared Spectrophotometry (Fixed-Wavelength at 2924 cm⁻¹)
Measurement RangeTransmittance 0–100%, Absorbance 0–2.0, Bandwidth 30 cm⁻¹ (0.04 µm)
Detection Limit< 0.2 mg/L
Accuracy±1%
Resolution1 ppm
Measurement Frequency6 measurements/min
Signal-to-Noise Ratio> 2500:1
Drift0.01 Abs/hr
Response Time10 s (Damping 1), 40 s (Damping 2)
Dimensions (W×D×H)36 × 28 × 26 cm
Weight10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (United Instrumentation Corporation)
OriginUSA
ModelCM130
Instrument TypeLaboratory TOC Analyzer
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement Range0–10,000 µg C
Accuracy±0.2% (for 1,000–3,000 µg C samples)
Resolution0.01 µg C
Detection Limit0.01 ppm C
Repeatability≤3% RSD
ComplianceASTM D4129
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRivertrace
OriginUnited Kingdom
ModelCW Series
Measurement Range0–99 ppm
Accuracy±5 ppm
DisplayDual-line 7-segment LED
Alarm SetpointsAdjustable (1–98 ppm)
Alarm DelayAlarm 1: 0–60 s
Alarm 210–240 s
Alarm Output8 A @ 240 V (inductive)
Analog Outputs0–20 mA / 4–20 mA (min. load 820 Ω)
Ambient Temperature1–50 °C
Relative Humidity≤90% RH (up to +55 °C)
Sample Temperature1–50 °C
Sample Flow Rate0.1–2 L/min
Sample Pressure0.1–10 bar
Dimensions (W×D×H)215 × 242 × 73 mm
Weight2.25 kg
Power Supply230 V/50 Hz or 24 V AC
Power Consumption10 VA
Electrical SafetyEN 61010-1 / IEC 61000-6-4 / IEC 61000-6-2
CertificationGermanischer Lloyd (GL) Type Approved
Optical ComponentsHigh-temperature resistant fused silica windows & fluorosilicone seals
Wetted MaterialsOptional 316 stainless steel probe, flow cell, and sample chamber
Auto-cleaningIntegrated ultrasonic or mechanical cleaning module (configurable)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCzech Republic
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelLTX Unique
Price RangeUSD 55,000 – 69,000 (FOB)
Measurement PrincipleCombustion-Coulometric Titration
Measurement Range0.1–200 µg Cl⁻ per sample
AccuracyBetter than ±1.5% (for 10–50 µg Cl⁻ or S)
Repeatability<1% RSD
Detection Limit0.1–200 µg Cl⁻
Resolution0.01 µg Cl⁻
AOX/TX/EOX/POX Quantification Range0.1–320 mg Cl⁻ (absolute)
Analysis Time3–6 min per sample
Electrolytic Signal Resolution5 mV
Titration Current Range0–2000 µA
Electrolyte Volume5–35 mL
SoftwareENGINE XS v5.2
Max. Liquid Sample Volume100 mL (AOX/POX)
Max. Solid Sample Mass5 g
Dual-Furnace SystemHigh-Temperature Combustion Furnace (up to 1200 °C
Power Supply230 V / 50 Hz, max. 1000 W (6 A)
Dimensions (L×W×H)1070 × 360 × 385 mm
Standard ConfigurationMain analyzer unit with dual-furnace module, coulometric titration cell, integrated gas purification system, and ENGINE XS software suite
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXTRA
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0