- All
- Favorite
- Popular
- Most rated
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XTRA Oil-in-Water Analyzer |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart |
| Pricing | Available Upon Request |
| Brand | Rivertrace |
|---|---|
| Origin | United Kingdom |
| Model | Smart 50M |
| Measurement Range | 0–10 ppm (large cell) / 0–200 ppm (medium cell) |
| Accuracy | ±0.15 ppm (large cell) / ±2 ppm (medium cell) |
| Display Resolution | 0.1 ppm |
| Alarm Setpoints | Adjustable (1–10 ppm or 10–200 ppm per cell) |
| Alarm Delay | 1–15 s (Alarm 1), 1–600 s (Alarm 2) with disable option |
| Output Signal | 4–20 mA |
| Sample Temperature | +1 to +90 °C |
| Sample Flow Rate | 0.3–3 L/min |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | +1 to +50 °C |
| Ambient Humidity | ≤80 % RH, non-condensing |
| Enclosure Rating | IP55 |
| Power Supply | 230 VAC, 50 Hz, 15 VA |
| Dimensions (W×D×H) | 500 × 360 × 150 mm |
| Weight | 15 kg |
| Certifications | Germanischer Lloyd (GL) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OCD50 |
| Pricing | Upon Request |
| Brand | UIC (USA) |
|---|---|
| Origin | USA |
| Model | CM350 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Coulometric Titration (Faraday-based SO₂/H₂S Detection) |
| Dynamic Range | 1 µg – 10,000 µg S per sample |
| Detection Limit | ~1 µg S (absolute) |
| Linear Range | 0.2% RSD or better for certified standards |
| Sample Forms | Solids (0.5 mg – 10 g) and Liquids |
| Total Analysis Time | 5–7 min (combustion mode) |
| Combustion Temperature | Up to 1100 °C (dual-zone furnace) |
| Acid Digestion | Modified Monier-Williams method with programmable heating & gas purging |
| Data Storage | Internal memory + 3.5″ floppy disk (CM5014S unit) |
| Compliance Support | ASTM D3120, D3246, D5453 |
| Brand | BUCK |
|---|---|
| Origin | USA |
| Model | HC-404 |
| Instrument Type | Laboratory Analyzer |
| Principle | Infrared Spectrophotometry (Fixed-Wavelength at 2924 cm⁻¹) |
| Measurement Range | Transmittance 0–100%, Absorbance 0–2.0, Bandwidth 30 cm⁻¹ (0.04 µm) |
| Detection Limit | < 0.2 mg/L |
| Accuracy | ±1% |
| Resolution | 1 ppm |
| Measurement Frequency | 6 measurements/min |
| Signal-to-Noise Ratio | > 2500:1 |
| Drift | 0.01 Abs/hr |
| Response Time | 10 s (Damping 1), 40 s (Damping 2) |
| Dimensions (W×D×H) | 36 × 28 × 26 cm |
| Weight | 10 kg |
| Brand | UIC (United Instrumentation Corporation) |
|---|---|
| Origin | USA |
| Model | CM130 |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–10,000 µg C |
| Accuracy | ±0.2% (for 1,000–3,000 µg C samples) |
| Resolution | 0.01 µg C |
| Detection Limit | 0.01 ppm C |
| Repeatability | ≤3% RSD |
| Compliance | ASTM D4129 |
| Brand | Rivertrace |
|---|---|
| Origin | United Kingdom |
| Model | CW Series |
| Measurement Range | 0–99 ppm |
| Accuracy | ±5 ppm |
| Display | Dual-line 7-segment LED |
| Alarm Setpoints | Adjustable (1–98 ppm) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s |
| Alarm Output | 8 A @ 240 V (inductive) |
| Analog Outputs | 0–20 mA / 4–20 mA (min. load 820 Ω) |
| Ambient Temperature | 1–50 °C |
| Relative Humidity | ≤90% RH (up to +55 °C) |
| Sample Temperature | 1–50 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure | 0.1–10 bar |
| Dimensions (W×D×H) | 215 × 242 × 73 mm |
| Weight | 2.25 kg |
| Power Supply | 230 V/50 Hz or 24 V AC |
| Power Consumption | 10 VA |
| Electrical Safety | EN 61010-1 / IEC 61000-6-4 / IEC 61000-6-2 |
| Certification | Germanischer Lloyd (GL) Type Approved |
| Optical Components | High-temperature resistant fused silica windows & fluorosilicone seals |
| Wetted Materials | Optional 316 stainless steel probe, flow cell, and sample chamber |
| Auto-cleaning | Integrated ultrasonic or mechanical cleaning module (configurable) |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LTX Unique |
| Price Range | USD 55,000 – 69,000 (FOB) |
| Measurement Principle | Combustion-Coulometric Titration |
| Measurement Range | 0.1–200 µg Cl⁻ per sample |
| Accuracy | Better than ±1.5% (for 10–50 µg Cl⁻ or S) |
| Repeatability | <1% RSD |
| Detection Limit | 0.1–200 µg Cl⁻ |
| Resolution | 0.01 µg Cl⁻ |
| AOX/TX/EOX/POX Quantification Range | 0.1–320 mg Cl⁻ (absolute) |
| Analysis Time | 3–6 min per sample |
| Electrolytic Signal Resolution | 5 mV |
| Titration Current Range | 0–2000 µA |
| Electrolyte Volume | 5–35 mL |
| Software | ENGINE XS v5.2 |
| Max. Liquid Sample Volume | 100 mL (AOX/POX) |
| Max. Solid Sample Mass | 5 g |
| Dual-Furnace System | High-Temperature Combustion Furnace (up to 1200 °C |
| Power Supply | 230 V / 50 Hz, max. 1000 W (6 A) |
| Dimensions (L×W×H) | 1070 × 360 × 385 mm |
| Standard Configuration | Main analyzer unit with dual-furnace module, coulometric titration cell, integrated gas purification system, and ENGINE XS software suite |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XTRA |
| Pricing | Available Upon Request |
Show next