- All
- Favorite
- Popular
- Most rated
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 225 / D2068 |
| Compliance | ASTM D2068, IP 387 |
| Operating Temperature Range (Bath) | −10 °C to +40 °C |
| Sample Temperature Range | −50 °C to +80 °C |
| Flow Rate | 20 mL/min |
| Pressure Measurement Range | 0–210 kPa |
| Max. Pressure Threshold | 105 kPa |
| Filtration Capacity Resolution | 0.1 mL |
| Temperature Sensor | PT100 Class A |
| Bath Material | Anodized Aluminum |
| Cooling System | Single-phase air-cooled compressor, CFC-free refrigerant |
| Data Storage Capacity | 60,000 test records |
| Display | 6.4″ TFT/LCD touchscreen (640 × 480 pixels) |
| Processor | AMD Geode 800 |
| Interface | 1 × USB, 1 × 10/100 Mbps LAN |
| Safety Certification | CE |
| Origin | Norway |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F-100 |
| Pricing | Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VP4000 |
| Pricing | Upon Request |
| Standards Compliance | DIN 51581, CEC L-40-A-93, ASTM D5800 |
| Temperature Range | 150–260 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | < ±0.5 °C at Setpoint |
| Air Flow Control | Adjustable via valve or flowmeter |
| Max Differential Pressure | 21 mmWS |
| Pressure Accuracy | ±0.02 mmWS |
| Test Duration | Fixed 60 min |
| Display | LCD showing real-time temperature, pressure, and elapsed time |
| Dimensions (W×D×H) | 278 × 300 × 316 mm |
| Net Weight | 14 kg |
| Gross Weight | 23 kg |
| Included Components | Main unit, vacuum pump with oil filter, evaporation crucible, test ball, differential pressure controller |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 700 |
| Standard Compliance | ASTM D5191, ASTM D323, IP 394 |
| Measurement Principle | Vapor Pressure via Air-Saturation Method at 37.8 °C |
| Sample Volume | 3 mL |
| Test Chamber Volume | 15 mL |
| Chamber Temperature Control | 37.8 °C ± 0.1 °C (PT100, 1/10 DIN accuracy) |
| Sample Temperature Control | 0 °C (external chiller required) |
| Pressure Range | 0–10 bar absolute (0–145 psi) |
| Vacuum System | Integrated vacuum pump interface |
| Dimensions (W×D×H) | 30 × 70 × 60 cm |
| Weight | 27 kg |
| Power Supply | 230 V / 50 Hz |
| Ambient Operating Conditions | ≤35 °C, ≤80% RH |
| Brand | Linetechnic |
|---|---|
| Origin | Switzerland |
| Model | 226 (ASTM D4539 Compliant) |
| Cooling Range | +80 °C to −45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.06 °C |
| Vacuum Control | Precisely regulated at 20 kPa |
| Sample Capacity | 6 × 300 mL positions |
| Cooling Rate | 1 °C/h |
| Pass Criterion | ≥180 mL filtrate collected within 60 s under vacuum |
| Temperature Sensor | PT100 Class A |
| Built-in Control System | AMD Geode800 CPU, 12″ TFT touchscreen (1024 × 768), 60,000-test storage capacity |
| Refrigerant | CFC-free compressor system |