Empowering Scientific Discovery

Beijing Daiso Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (United Instruments Corporation)
OriginUSA
Model833
Molecular Weight Range100–25,000 Da (in toluene), 100–5,000 Da (in water)
Minimum Detectable Concentration5 × 10⁻⁵ mol/L (toluene), 2.5 × 10⁻⁴ mol/L (water)
Temperature Control RangeAmbient to 130 °C (with optional cryo-circulator for sub-ambient operation)
Cell Current Settings5, 20, 100 µA
Equilibration Time2–5 min per sample
Sample Volume0.25 mL
ConstructionAll-metal hermetic cell housing with dual needle-port inlet system
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model2701
PricingAvailable Upon Request
Max Operating Temperature1913 °C
Arc Current Range400–600 A
Argon Gas Flow Requirement50 L/min
Crucible MaterialWater-Cooled Copper
Anode OptionsGraphite, Carbon, Tungsten
Typical Melting Time≤60 s
Sample Forms AcceptedPowders, Drill Chips, Cut Strips, Slurries
Max Sample Mass (Steel)50 g (Ø31.8 mm × 6.4 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMIKROLAB
OriginDenmark
ModelOXIPRES
Sample Capacity100 mL (with ≥5 g fat)
Operating Pressureup to 10 bar (1 MPa)
Temperature Range30–150 °C
Heating Block Max Temp150 °C
Pressure SensingElectronic transducer
Output Signal1 V FS or 5 V FS
Dimensions (2/4/6-sample configurations)41 × 30 / 62 × 30 / 83 × 30 cm
Footprint~600 mm (excl. PC)
Power Supply230 V / 50 Hz, max. 8 A
SoftwarePARALOG v3
Gas Charging StationDual- or hexa-port with safety valve
Sample Vessel125 mL borosilicate glass jar with sealing lid and O-ring
Added to wishlistRemoved from wishlist 0
Add to compare
OriginPoland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelSPD2.2
Price RangeUSD 27,000 – 68,000
ComplianceASTM E1226, ASTM E1515, EN 14034-1:2004+A1:2011, EN 14034-2:2006+A1:2011, EN 14034-3:2006+A1:2011
Vessel Volume20 L
Vessel MaterialAISI 316 Stainless Steel
Maximum Working Pressure40 bar (gauge)
Pressure Measurement Range0–25 bar (absolute)
(dp/dt)max Detection Threshold>4000 bar/s
Kst Range>1000 bar·m/s
Explosibility ParametersLEL/UEL/MEC from 0 g/m³, LOC: 1–21 % O₂
Dust Injection Valve Response Time≤30 ms
Vacuum Display Range0–1 bar (absolute)
Vacuum ControlAuto & Manual Modes
Vessel Temperature MonitoringFront-panel digital readout
Data Acquisition Rate10–100 kHz
SoftwareANKO Explosion Plotter v3.x (GLP-compliant reporting, audit trail, test sequence automation, noise-filtered signal processing, PDF report generation)
AccessoriesIntegrated vacuum pump unit, exhaust scrubber with flow controller, borosilicate observation viewport, dedicated workstation, thermal printer
Added to wishlistRemoved from wishlist 0
Add to compare
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelHTM1400
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBUCK
OriginUSA
Instrument TypeBenchtop Laboratory Analyzer
PrincipleCold Vapor Atomic Absorption Spectrometry (CVAAS)
Detection Wavelength253.7 nm
Detection Limit10 pg/L (ppt) under controlled clean-lab conditions
Sample Cell Path Length400 mm fused silica window
Background CorrectionOnline Deuterium Lamp (D₂)
Output InterfacesRS-232 serial port, analog output (0–1 V or 4–20 mA)
Sample IntroductionAir-driven purge-and-trap with integrated desiccant and charcoal filtration
Dimensions (W×D×H)991 × 279 × 305 mm
Weight21 kg
Power Requirement220 V, 50 Hz, 80 W
ComplianceFully compliant with U.S. EPA Method 245.1
CalibrationUp to 8-point linear or quadratic calibration curves
Operational FeaturesQuick-Purge button for flow-cell cleaning, Peak-Picker peak-area integration, GLP-ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
TypeBox-Type Muffle Furnace
Max Temperature1700°C or 1800°C
Chamber Volume4 L to 27 L
Heating ElementsMoSi₂ or Mo–W–Si₂
Control OptionsEurotherm 2116 / 2216 / 2416 CG / 2408 CP
Power Range4.4 kW to 15.0 kW
Door OperationManual or Motorized
Safety FeaturesOver-Temperature Protection, Electronic Door Lock, Vertical Lift Door, Dual-Wall Insulated Housing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandReichert
OriginUSA
ModelBrix/RI-Chek
Product TypeHandheld Refractometer
Temperature ControlYes (ATC)
Digital DisplayYes (5-digit full-view LCD)
Refractive Index Range1.3330 – 1.4465
RI Accuracy±0.0002
Brix Range0.0 – 62.0%
Brix Accuracy±0.2%
Prism MaterialOptical Glass
Dimensions54 × 27 × 100 mm
Weight100 g
IP RatingIP65
CertificationsCE, RoHS, WEEE
Warranty1 year
Order Code13940000
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelASTM D566
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
Detection PrincipleNon-Dispersive Infrared (NDIR)
ModelCS2000M
Measurement RangeC: 0–100%, S: 0–100%
Accuracy±1% of measured content
Analysis Time90 s (typical)
Sample Mass300–500 mg
Combustion TemperatureAmbient to 1400 °C
Oxygen Purity>99.5%, Pressure: 40 PSI
Gas Flow Rate3.0 L/min
ReagentMagnesium Perchlorate
Interface4 RS-232 ports for analytical balance integration
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
Detection PrincipleNon-Dispersive Infrared (NDIR)
ModelCSBox-Tube-S
Measurement Range0.005–100 wt% S
Accuracy±1% relative (typical samples)
Sample Mass10–200 mg
Analysis Time40–300 s
Combustion Temperature800–1500 °C (configurable by mode)
Interface Protocol SupportSartorius, Mettler, Precia, Ohaus (RS-232/USB), manual entry
Data OutputLPT, COM, USB, LAN (RJ45)
Operating SystemFreeDOS on Advantech industrial motherboard
Added to wishlistRemoved from wishlist 0
Add to compare
OriginNew Zealand
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model5400RHS
PriceUpon Request
Temperature Range−10 °C to +100 °C
Temperature Stability±0.3 °C
Temperature Uniformity±0.75 °C
Humidity Range35–98 %RH
Humidity Accuracy±2 %RH
Effective Volume400 L
Internal Dimensions (W×D×H)640 × 540 × 1225 mm
External Dimensions (W×D×H)890 × 870 × 2045 mm
Shelf Capacity6 adjustable stainless-steel shelves
Cooling Rate70 °C → 0 °C in ≤60 min
Heating Rate−10 °C → 70 °C in ≤45 min
Power Consumption1750 W
Net Weight200 kg
Gross Weight240 kg
ComplianceNZS 6200, AS/NZS 3100, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCzech Republic
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelDeasphaltop
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelE2K
Operating Temperature Range0–60 °C
Temperature Repeatability≤0.1% RSD
Temperature Resolution1 µK
Gross Calorific Value Resolution0.001 MJ/kg
Calibration10 stored calibration curves per smart bomb vessel, automatic standard deviation correction, integrated calibration sensors per vessel
Sample ThroughputUp to 10 samples/hour (standard configuration)
Measurement Time1.5–3 min per test
Dimensions (W×D×H)280×400×290 mm
Weight9 kg
Data Storage Capacity>1000 test records with full metadata (operator ID, ambient conditions, calibration traceability)
ConnectivityEthernet-enabled for multi-unit network (up to 7 units)
Ignition ControlAdjustable ignition energy, programmable high/low sample mass limits, customizable test cycle parameters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandUIC (USA)
OriginUSA
ModelCM350
CategoryOther Elemental Analyzers
ComplianceASTM D3120, D3246, D5453
Detection PrincipleCoulometric titration based on Faraday’s law
Dynamic Range1 µg – 10,000 µg sulfur (equivalent to ~1 ppm – 100% w/w, sample-dependent)
Resolution0.01 µg S
Analysis Time5–7 min (combustion mode), ≤15 min (acid digestion mode)
Sample FormsSolids (0.5 mg – 10 g) and liquids
Furnace Max Temp1100 °C
Data StorageInternal floppy drive (CM5014S), exportable via RS232
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
TypeASTM D86 Compliant Manual Atmospheric Distillation System
Model1000 Series
ConfigurationModular (Heating Unit 990/A + Condensation Unit 990/B)
ComplianceASTM D86, IP 62–88, ISO 3405
Heating ControlElectronically Adjustable Stainless Steel Heating Plate
CondenserChrome-Plated Copper Tubing with Water-Circulated Jacket
VisibilityFront-Mounted Tempered Glass View Window
Bottle Capacity Options100 mL (Type A), 125 mL (Type B), 200 mL (Type C), 250 mL (Type D)
Receiver Volumes25 mL (Type A), 100 mL (Type B), 200 mL (Type C)
Temperature MeasurementASTM/IP Calibrated Thermometers (ASTM 2C to 107C / IP 62C to 88C)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelXTRA Oil-in-Water Analyzer
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSwitzerland
TypeASTM D92 Cleveland Open Cup Flash Point Tester
Temperature Range+79 °C to +400 °C
Temperature Resolution0.06 °C
Temperature Accuracy±0.1 °C
Temperature ProbePT100 Platinum Sensor (1/10 DIN Class)
Sample CupASTM D92 / IP 36–compliant dimensions and fill level markings
Heating SystemElectronic heater with overtemperature protection
Repeatability & ReproducibilityMeets or exceeds ASTM D92 and IP 36 requirements
Dimensions (W×D×H)48 × 37 × 61 cm
Weight32 kg
Power Supply220 V ±15 %, 50/60 Hz
Ambient Operating Limit≤35 °C
Safety CertificationCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
(OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelD323
PricingAvailable Upon Request)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLinetechnic
OriginSwitzerland
Model225 / D2068
ComplianceASTM D2068, IP 387
Operating Temperature Range (Bath)−10 °C to +40 °C
Sample Temperature Range−50 °C to +80 °C
Flow Rate20 mL/min
Pressure Measurement Range0–210 kPa
Max. Pressure Threshold105 kPa
Filtration Capacity Resolution0.1 mL
Temperature SensorPT100 Class A
Bath MaterialAnodized Aluminum
Cooling SystemSingle-phase air-cooled compressor, CFC-free refrigerant
Data Storage Capacity60,000 test records
Display6.4″ TFT/LCD touchscreen (640 × 480 pixels)
ProcessorAMD Geode 800
Interface1 × USB, 1 × 10/100 Mbps LAN
Safety CertificationCE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLinetechnic
OriginSwitzerland
Model1300
Temperature Range+80 °C to –80 °C
Cooling SystemSingle-stage or dual-stage compressor (–40 °C or –85 °C min)
Temperature SensorPT100 Class A
Temperature Resolution0.06 °C
Temperature Accuracy±0.1 °C
ComplianceASTM D2500, D5771–D5773, D97, D5950, D5853
Optical DetectionPulsed IR fiber-optic probe for cloud point
Mechanical DetectionDual PT100 surface probes + motorized tilt arm for pour point
Added to wishlistRemoved from wishlist 0
Add to compare
OriginRussia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelIM Series
Measurement ParametersGasoline Octane Number (ON), Diesel Cetane Number (CN)
PortabilityHandheld Field-Deployable
Measurement Range40–120 ON, 40–60 CN
Accuracy±0.5 ON, ±1.0 CN
Analysis Time<10 s per sample
Sample Volume10 mL
Temperature & Cloud Point MeasurementIntegrated digital thermometry and diesel cloud point estimation
ComplianceASTM D2699-86, ASTM D2700-86, ASTM D4737-03, ASTM D613, EN ISO 5165
Calibration InterfaceRS-232 serial connection for PC-based calibration using Windows Mobile-compatible software (Pocket PC 2000/2002)
Power Supply5.2 V DC internal / 5.8 V external
Dimensions (Main Unit)100 × 210 × 40 mm
Probe DimensionsØ60 × 100 mm
Battery LifeUp to 1000 hours of cumulative operational time
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBadger
Instrument TypeJaw Crusher
Sample ApplicabilityBrittle Materials (e.g., rocks, ores, ceramics, metals, chemicals)
Feed Size< 15 mm
Discharge Size≥ 0.5 mm
Batch Capacity60 mL
Jaw Opening127 mm × 178 mm
Motor3 HP, 3-Phase, 380 V, 400 rpm
Bearing TypeSealed Spherical Roller Bearings
Crushing Capacity590 kg/h
Jaw Plate MaterialChrome Steel (standard)
Base & GuardStainless Steel
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBMF11/7
Instrument TypeBox-Type Muffle Furnace
Max Temperature1100 °C
Operating Temperature RangeAmbient to 1050 °C (continuous)
Temperature Uniformity±5 °C at 1050 °C
Control Accuracy±2 °C
Internal Dimensions (W×D×H)178 × 305 × 125 mm
Effective Volume7 L
Max Power Consumption2 kW
Heating Rate to 1100 °C≤50 min
Heating ElementDual-sided Kanthal A1 wire embedded in ceramic fibre grooves
InsulationLow-mass, high-purity ceramic fibre (density ~128 kg/m³)
External CasingGalvanised steel with polyester powder coating
Door MechanismTop-hinged or front-hinged insulated door with automatic power cut-off interlock
ExhaustIntegrated chimney port (standard)
ThermocoupleType N (NiCr–NiSi), calibrated per IEC 60584
Electrical Supply240 V AC, single-phase
Net Weight48 kg
ComplianceCE-marked, conforms to EN 61000-6-3 (EMC), EN 61000-6-2 (Immunity), EN 60519-1 (Electrical Safety for Industrial Heating Equipment)