Empowering Scientific Discovery

Beijing Daiso Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelMFS-12
QuotationUpon Request
Focal Length500 mm
Spectral Range190–425 nm
Detector10 linear CCD arrays, 3648 pixels each
Sample StageUniversal design for solid metals, rods, wires, and pressed powders (e.g., ores, oxides, ferroalloys, slags)
Excitation SourceComputer-controlled low-voltage spark generator
Plasma Current25–350 A
Discharge Duration30–600 µs
Repetition Frequency50–400 Hz
Detection Limit0.001 wt%
Concentration Range0.001% to tens of %
Relative Standard Deviation0.5–5% (concentration-dependent)
Analysis Time10–40 s per sample
Operating Temperature15–25 °C
Relative Humidity≤80% (non-condensing)
Power Supply220 V ±10%, 50 Hz, single-phase with earth grounding
Max. Power Consumption2.5 kVA
Dimensions (W×H×D)834 × 995 × 520 mm
Weight110 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSherwood
OriginUnited Kingdom
Model425
Optical SystemSingle-beam
DetectorPhotodiode Array
Wavelength Range190–900 nm
Wavelength Accuracy±2.0 nm
Wavelength Repeatability±0.5 nm
Spectral Bandwidth4 nm
Stray Light≤0.01% T
Elements MeasuredNa, K, Li, Ca
Linear DisplayDual-channel Digital LED
Output0.05–5.0 V Analog Signal
InterfaceRS232
Fuel GasPropane/Butane/Natural Gas (6 L/min at 15 PSI)
Detection LimitsNa/K: 20 ppb (S/N = 2)
SensitivityNa/K: 0.5 ppm
Li2 ppm
Ca5 ppm
Interference<0.5%
Linearity<1%
Precision (RSD)≤0.5%
Stabilization Time~15 s per reading
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Supplier TypeAuthorized Distributor
Import StatusImported
ModelV-950
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Supplier TypeAuthorized Distributor
Import StatusImported
Model210VGP
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorConcave Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Spectral Resolution0.1 nm
SensitivityCu 5 ppm, Absorbance > 0.3 A
Repeatability (RSD)< 0.3%
Detection LimitCu ≤ 0.005 mg/L
Wavelength Range190–900 nm
Wavelength Accuracy±0.2 nm
Wavelength Precision±0.1 nm
Slit Widths0.2 / 0.7 / 2.0 nm
Background CorrectionDeuterium Lamp (190–350 nm) and Self-Reversal HCL (190–900 nm)
AtomizationAir/Acetylene, N₂O/Acetylene, Ar/H₂ premixed flame
Furnace Max Temp3000 °C in <1 s
Data InterfaceRS-232C, IEEE-488 (GPIB), Parallel Printer Port
Dimensions (L×W×H)991 × 279 × 305 mm
Net Weight23 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
Model2950
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelM500
PriceUpon Request
Wavelength Range4000–600 cm⁻¹
Scan Speed Options3 / 6 / 12 / 24 min per scan
Data Points per Scan4,250 (3 min) to 34,000 (24 min)
Detector1×2 mm DLaTGS (Deuterated L-Alanine doped Triglycine Sulfate), Sensitivity: 1 V/mW
Sample Compartment Area150 mm²
DisplayBuilt-in LCD for wavenumber/absorbance readout
InterfaceRS-232, analog recorder output
Heater ElementNiCr wire on sintered ceramic core
Dimensions66.7 × 38.7 × 18.4 cm (26.25″ × 15.25″ × 7.25″)
Weight17.2 kg (38 lbs)
Power Supply115/230 V AC, 50/60 Hz, 150 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelUV-2602
PriceUpon Request