| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | AquaPen AP110 |
| Detection Limit | 0.5 µg Chl/L |
| Excitation Wavelengths | 455 nm (blue), 620 nm (red) for AP110-C |
| Emission Detection Range | 667–750 nm |
| Optical Configurations | AP110-C (cuvette-based, 4 mL volume, OD680 & OD720 capability), AP110-P (submersible probe) |
| Time Resolution | 10 µs (100,000 measurements/s) for OJIP kinetics |
| Fluorescence Parameters | >50 standard and derived parameters including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, Rfd, Area, Mo, Sm, PI_ABS, ABS/RC, TR₀/RC, ET₀/RC, DI₀/RC, and 26 OJIP-specific indices |
| Light Sources | Measuring light (0.09 µmol photons/m²·s, 10–100% adjustable), Actinic light (10–1000 µmol photons/m²·s), Saturating pulse (up to 3000 µmol photons/m²·s, 11–100% adjustable) |
| Data Storage | 16 MB flash memory (≈149,000 data points) |
| Power | Rechargeable 2000 mAh Li-ion battery (48 h continuous operation) |
| Dimensions | 165 × 65 × 55 mm (body only), Weight: 290 g |
| Environmental Rating | 0–55 °C operating, 0–95% RH (non-condensing) |
| Connectivity | Dual-mode Bluetooth 5.0 (20 m range, 3 Mbps max) + USB 2.0 |
| Integrated GPS | Yes (1.5 m horizontal accuracy) |
| Software | FluorPen v1.1 (Windows 7+, Excel export, kinetic curve visualization, remote instrument control, audit-ready data logging) |
| Brand | PSI |
|---|---|
| Origin | Czech Republic |
| Model | MC1000 |
| Channel Count | 8 |
| Culture Vessel Capacity | 100 mL (max. 85 mL working volume) |
| Optical Density Monitoring | OD₆₈₀ & OD₇₂₀ per channel |
| Light Source | Tunable LED array (0–2500 µmol/m²/s), wavelength options include 405 nm, 450 nm, 470/475 nm, 530/540 nm, 590 nm, 615 nm, 660 nm, 730 nm |
| Temperature Control | Water-bath heating (150 W), standard range: ambient +5°C to 60°C |
| optional refrigerated range | 15–60°C |
| Water Bath Volume | 5 L |
| Gas Mixing | Optional GMS150 precision gas blending system (N₂/air/CO₂) |
| Dissolved O₂ & CO₂ Monitoring | Optional 8-channel electrochemical/O₂ sensor and NDIR CO₂ analyzer (0–5% or 0–15% range, resolution ≤1 ppm) |
| Fluorescence Module | Optional probe-based or cuvette-based measurement of Ft, QY, OJIP, NPQ, and light-response curves |
| Software | PBR Control Suite (Basic or Advanced Edition), supporting real-time regression analysis, database logging, GUI-based protocol scheduling, email alerts, and GLP-compliant audit trail (Advanced Edition) |
| Power Supply | 110–240 V AC |
| Dimensions | 71 × 33 × 21 cm |
| Weight | 13 kg |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | FMT150 |
| Volume Options | 400 mL / 1000 mL / 3000 mL |
| Temperature Control Range | 5–75 °C (dependent on vessel type) |
| PAR Intensity | Up to 3000 µmol photons·m⁻²·s⁻¹ (configurable per wavelength) |
| Light Sources | Red, Blue, White LEDs (single/dual/multi-spectral) |
| Fluorescence Detection | Dual-modulation chlorophyll fluorometer (F₀, Fₘ, Fₘ′, QY, ΦPSII) |
| Optical Density | OD₆₈₀ & OD₇₂₀ via PIN photodiode + bandpass filter (665–750 nm) |
| Gas Control | Optional GMS high-precision gas mixing system (N₂, air, CO₂, O₂) |
| pH/DO/CO₂ Sensing | Optional calibrated electrochemical sensors |
| Pump Capacity | Up to 8 per unit (PP600 peristaltic pumps) |
| Software | PSI FMT150 Control Suite (Basic & Advanced editions, FDA 21 CFR Part 11–compliant audit trail optional) |
| Compliance | CE-marked |