| Brand | Specim |
|---|---|
| Origin | Czech Republic |
| Model | AisaFENIX_1K |
| Spectral Range | 380–2500 nm (VNIR + SWIR) |
| Spatial Resolution | 1024 pixels |
| Spectral Resolution | 4.5 nm (VNIR), 14 nm (SWIR) |
| FOV | 40° |
| Frame Rate | up to 100 Hz |
| SNR | 600–1000:1 (VNIR), 1250:1 (SWIR) |
| Data Interface | CameraLink (12-bit VNIR, 16-bit SWIR) |
| Operating Temperature | +5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Power Consumption | <150 W (typ.), <500 W (peak) |
| Weight | Sensor 22.5 kg, DPU 9.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | RedEdge-MX |
| Price Range | USD 13,500 – 27,000 (est. FOB) |
| Weight | 231.9 g (incl. DLS 2 & cable) |
| Dimensions | 8.7 cm × 5.9 cm × 4.54 cm |
| Power Input | 4.2–15.8 V DC |
| Typical Power Consumption | 4 W (peak: 8 W) |
| Spectral Bands | Blue (475 nm), Green (560 nm), Red (668 nm), Red Edge (717 nm), Near-Infrared (840 nm) |
| Bandwidth | ±10 nm (FWHM) |
| Spatial Resolution | 8 cm GSD at 120 m AGL |
| Frame Rate | 1 image/sec (full 5-band capture) |
| Shutter | Global shutter |
| FOV | 47.2° (diagonal) |
| Spectral Range | 400–900 nm |
| Trigger Modes | Timed, Overlap, External TTL, Manual |
| Operating Temp | 0–40 °C (still air), 0–50 °C (with airflow >0.5 m/s) |
| Interfaces | UART, 10/100/1000BASE-T Ethernet, Wi-Fi 802.11 b/g/n, GPS, SDHC slot, GPIO trigger |
| Data Output | Radiometrically calibrated raw TIFF (16-bit), geotagged, with embedded DLS 2 metadata |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | SisuSCS |
| Spectral Range Options | 400–1000 nm (VNIR) or 1000–2500 nm (SWIR) |
| Weight | ~100 kg |
| Application | Single-core scanning for geological and lacustrine sediment cores |
| Compliance | Designed for laboratory-based geoscientific research environments |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YellowScan Mapper+ |
| Pricing | Available Upon Request |
| Brand | Specim |
|---|---|
| Origin | Czech Republic |
| Model | AisaFENIX |
| Spectral Range | 380–2500 nm |
| Optical Throughput | >65% |
| SNR (VNIR) | 600–1000:1 |
| SNR (SWIR) | ≥1050:1 |
| Spectral Sampling | up to 620 bands |
| Spatial Resolution | 384 pixels |
| Frame Rate | up to 100 Hz |
| F-number | F/2.4 |
| Smile/Keystone Distortion | <0.2 pixels |
| Polarization Sensitivity | Negligible |
| Data Interface | CameraLink (12-bit VNIR, 16-bit SWIR) |
| Power Consumption | <150 W typical, <500 W peak |
| Operating Temperature | +5°C to +40°C (non-condensing) |
| Storage Temperature | −20°C to +50°C |
| Detector Technology | CMOS (VNIR), Stirling-cooled MCT (SWIR) |
| Spectral Resolution | 3.5 nm (VNIR), 12 nm (SWIR) |
| FOV | 32.3° |
| IFOV | 0.084° |
| Spectral Binning Options | 2×, 4×, 8× (VNIR) |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SisuRock |
| Pricing | Available Upon Request |
| Spectral Ranges (Configurable) | 400–1000 nm (VNIR) |
| Pixel Resolution | 0.2 mm |
| Scan Speed | 20 mm/s |
| Maximum Sample Dimensions | 150 cm (L) × 65 cm (W) × 20 cm (H) |
| Max Sample Weight | 50 kg |
| System Mass | ~500 kg |
| Brand | Specim |
|---|---|
| Origin | Czech Republic |
| Model | Specim SWIR |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution (FWHM) | 12 nm (30 µm slit) |
| Spatial Pixels | 384 |
| Spectral Bands | 288 |
| Pixel Size | 24 × 24 µm |
| Detector | Stirling-cooled MCT |
| Frame Rate | up to 450 fps (full frame) |
| Exposure Time | 0.1–20 ms |
| SNR | 1050:1 (at max signal level) |
| Interface | CameraLink (16-bit), USB/RS232 control |
| Power Consumption | <50 W |
| Operating Temperature | +5 to +40 °C (non-condensing) |
| Storage Temperature | −20 to +50 °C |
| IP Rating | IP54 |
| Optical f-number | f/2.0 |
| Slit Width Options | 30 µm (standard), 50 µm or 80 µm optional |
| Effective Slit Length | 9.2 mm |
| Cooling MTTF | 25,000 h |
| Data Format | ENVI, MATLAB, R-compatible hypercube |
| Software | LUMO (acquisition, scanning control, real-time visualization) |
| SDK | Available for custom application development |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | SpectraScan |
| Spectral Range Options | 400–1000 nm (VIS-NIR), 950–1700 nm (SWIR), 1000–2500 nm (SWIR) |
| Spectral Resolution (FWHM) | 2.9–12 nm |
| Spatial Resolution | 512–2184 pixels |
| Optical Aperture | f/1.7–f/2.4 |
| SNR | >400:1 to >1050:1 |
| Frame Rate | 45–670 fps |
| Weight | 1.26–>14 kg |
| Optional Modules | MWIR/LWIR imaging, Thermal IR integration, Solar-Induced Chlorophyll Fluorescence (SIF) imaging |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | AisaIBIS |
| Spectral Range | 670–780 nm |
| Spectral Sampling | 0.11 / 0.22 nm |
| Spatial Resolution | 384 × 768 pixels |
| Aperture | f/1.7 |
| SNR | 680:1 |
| Frame Rate | 65 fps |
| FOV | 32.3° |
| Integration Time | Adjustable per frame |
| Detector | Scientific-grade sCMOS, Peltier-cooled |
| Data Interface | CameraLink (16-bit) |
| Power Consumption | 135 W (typ.), 200 W (max.) |
| System Weight (incl. DPU) | <25 kg |
| Mechanical Shutter | Integrated |
| Thermal Stability | Active optical-thermal stabilization |
| Brand | Specim |
|---|---|
| Origin | Finland |
| Model | PFD VNIR |
| Spectral Range | 400–1000 nm |
| Spectral Resolution (FWHM) | 3.0 nm (with 30 µm slit) |
| Spatial Resolution | 1312 pixels (PFD-65-V10E) / 1775 pixels (PFD4K-65-V10E) |
| Frame Rate | up to 150 fps (full frame, 1312 × 768) / up to 100 fps (1775 × 768) |
| Spectral Sampling | 0.78–6.27 nm/pixel (adjustable via binning) |
| Slit Width | 30 µm (optional: 50 or 80 µm) |
| Effective Slit Length | 10.5 mm (PFD-65) / 14.2 mm (PFD4K) |
| Optical Throughput | >50% (polarization-independent) |
| Stray Light | <0.5% (halogen source, 590 nm LPF) |
| Detector | CMOS, 12-bit digital output |
| Pixel Size | 8.0 × 8.0 µm |
| F-number | f/2.4 |
| RMS Spot Size | <9 µm |
| Exposure Time Range | 0.1–100 ms |
| Power Consumption | <5 W |
| Input Voltage | 12 V (OEM), 24 V (integrated kit) |
| Operating Temperature | +5 to +40 °C (non-condensing) |
| Storage Temperature | −20 to +50 °C |
| Dimensions (OEM) | 231 × 80.5 × 78 mm |
| Dimensions (Kit) | 330 × 85 × 90 mm |
| Weight | 1.8 kg (OEM), 2.7 kg (kit) |
| Housing | Anodized aluminum with C-mount lens interface |
| Software Support | LUMO (acquisition, real-time visualization, ENVI-compatible data cube export) |
| Brand | SPECIM |
|---|---|
| Origin | Finland |
| Model | FX50 |
| Spectral Range | 2.7–5.3 µm |
| Spatial Resolution | Up to 640 × 512 pixels |
| Spectral Bands | 150 configurable bands |
| Interface | GigE Vision compliant |
| Cooling | Integrated Stirling cooler |
| Lens Options | Three interchangeable MWIR lenses (focal lengths optimized for FOV and working distance) |
| Integration Support | Specim SDK, ASCII command protocol, third-party machine vision software compatibility (e.g., HALCON, OpenCV, Common Vision Blox) |
| Illumination Compatibility | Dedicated MWIR broadband光源 available |
| Brand | SPECIM |
|---|---|
| Origin | Czech Republic |
| Model | AisaOWL |
| Spectral Range | 7.7–12.3 µm |
| Spectral Resolution | 100 nm (diffraction-limited) |
| F-number | F/2.0 |
| Spatial Resolution | 384 pixels |
| Frame Rate | up to 100 Hz |
| Field of View (FOV) | 24° or 32.3° |
| Instantaneous FOV (IFOV) | 0.063° or 0.084° |
| Spectral Bands | 96 |
| Spectral Sampling | 48 nm per band |
| Bit Depth | 14-bit LVDS output |
| Detector | Stirling-cooled MCT |
| Calibration | Integrated dual blackbody radiometric calibration |
| Operating Temperature | +5°C to +40°C (non-condensing) |
| Storage Temperature | −20°C to +50°C |
| Power Consumption | <200 W (sensor), <50 W (calibrator) |
| Dimensions (sensor) | 255 × 285 × 223 mm |
| Weight (sensor) | 13.1 kg |
| Dimensions (calibrator) | 365 × 194 × 110 mm |
| Weight (calibrator) | 4.5 kg |
| Software | CaliGeoPRO preprocessing suite |
| GNSS/IMU | High-precision integrated unit |
| Compliance | Designed for ASTM E1937, ISO 18434-1, and USP <1058> spectral instrument qualification frameworks |