Empowering Scientific Discovery

Beijing Ecoltech Ecological Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPSI (Czech Republic)
OriginCzech Republic
ModelAquaPen AP110
Detection Limit0.5 µg Chl/L
Excitation Wavelengths455 nm (blue), 620 nm (red) for AP110-C
Emission Detection Range667–750 nm
Optical ConfigurationsAP110-C (cuvette-based, 4 mL volume, OD680 & OD720 capability), AP110-P (submersible probe)
Time Resolution10 µs (100,000 measurements/s) for OJIP kinetics
Fluorescence Parameters>50 standard and derived parameters including F₀, Fₘ, Fᵥ/Fₘ, ΦPSII, NPQ, Rfd, Area, Mo, Sm, PI_ABS, ABS/RC, TR₀/RC, ET₀/RC, DI₀/RC, and 26 OJIP-specific indices
Light SourcesMeasuring light (0.09 µmol photons/m²·s, 10–100% adjustable), Actinic light (10–1000 µmol photons/m²·s), Saturating pulse (up to 3000 µmol photons/m²·s, 11–100% adjustable)
Data Storage16 MB flash memory (≈149,000 data points)
PowerRechargeable 2000 mAh Li-ion battery (48 h continuous operation)
Dimensions165 × 65 × 55 mm (body only), Weight: 290 g
Environmental Rating0–55 °C operating, 0–95% RH (non-condensing)
ConnectivityDual-mode Bluetooth 5.0 (20 m range, 3 Mbps max) + USB 2.0
Integrated GPSYes (1.5 m horizontal accuracy)
SoftwareFluorPen v1.1 (Windows 7+, Excel export, kinetic curve visualization, remote instrument control, audit-ready data logging)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMicromac 1000
Instrument TypeOnline Water Quality Analyzer
Measurement PrincipleColorimetric Flow Analysis (CFA) with Loop Flow Reactor (LFA)
Max Parameters per Cycle4
Detection LimitSub-ppb to ppm range (method-dependent)
Sample Volume per Analysis20–30 mL
Reagent Consumption< 500 µL per test
Dilution RatioUp to 1:100 (factory-calibrated)
Data Storage Capacity400 records (date, time, absorbance, concentration)
Output Signals4–20 mA (400 Ω load), 0–5 V, RS-232 (RS-485 optional)
Power Supply12 V DC
Power Consumption3 W (standby), 10 W (active)
Operating Temperature5–40 °C
IP RatingIP55 (IP65 optional)
Dimensions (L×H×W)550 × 350 × 110 mm
Weight13 kg (excluding reagents)
Sample Temp. Range10–30 °C
Sample Turbidity/ColorNo restriction (blank correction applied)
pH Range (method-dependent)3–12
Reaction Cell Pathlength10–50 mm (50 mm for seawater)
DetectorDual-beam silicon photodetector, multi-wavelength LED source
Flow SystemIntegrated peristaltic sampling pump + LFA reactor (10 mL volume)
ComplianceEPA, ISO, and DIN standard methods implemented
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
OriginDenmark
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBM-DAQ
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPSI
OriginCzech Republic
ModelMC1000
Channel Count8
Culture Vessel Capacity100 mL (max. 85 mL working volume)
Optical Density MonitoringOD₆₈₀ & OD₇₂₀ per channel
Light SourceTunable LED array (0–2500 µmol/m²/s), wavelength options include 405 nm, 450 nm, 470/475 nm, 530/540 nm, 590 nm, 615 nm, 660 nm, 730 nm
Temperature ControlWater-bath heating (150 W), standard range: ambient +5°C to 60°C
optional refrigerated range15–60°C
Water Bath Volume5 L
Gas MixingOptional GMS150 precision gas blending system (N₂/air/CO₂)
Dissolved O₂ & CO₂ MonitoringOptional 8-channel electrochemical/O₂ sensor and NDIR CO₂ analyzer (0–5% or 0–15% range, resolution ≤1 ppm)
Fluorescence ModuleOptional probe-based or cuvette-based measurement of Ft, QY, OJIP, NPQ, and light-response curves
SoftwarePBR Control Suite (Basic or Advanced Edition), supporting real-time regression analysis, database logging, GUI-based protocol scheduling, email alerts, and GLP-compliant audit trail (Advanced Edition)
Power Supply110–240 V AC
Dimensions71 × 33 × 21 cm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAquapHOx RF-Series
Instrument TypeOnline Water Quality Analyzer
Measured ParametersDissolved Oxygen (DO), pH, Temperature
Depth RatingUp to 4000 m
Data Storage4 GB Industrial-Grade Flash Memory
Sensor TechnologyRedFlash (RF) Optical Sensing
ComplianceDesigned for ASTM D888, ISO 5814, ISO 10523, and EU Horizon 2020–validated protocols
Added to wishlistRemoved from wishlist 0
Add to compare
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEasyChem 200
PricingUpon Request
Instrument TypeMulti-Parameter Ion Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelAOM
PriceAvailable Upon Request
Detection LimitChlorophyll-a: 30 ng/L
SensitivityGreen algae: 10 cells/mL
Cyanobacteria100 cells/mL
Measured ParametersFo, Ft, Fm, Fm′, OJIP transient, Turbidity
Actinic & Saturation Light Intensity0–3000 µE·m⁻²·s⁻¹ (adjustable)
Optical DetectorPhotodiode with 660–750 nm bandpass filter
Data InterfaceRS-232 or USB
Onboard Memory8 MB integrated data logger
IP RatingIP65
Operating Temperature0–45 °C
Dimensions198 × 60 × 295 mm
Weight1.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelOmniCTRL Water Environment Automated Control System
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMICROMAC 1000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPSI (Czech Republic)
OriginCzech Republic
ModelFMT150
Volume Options400 mL / 1000 mL / 3000 mL
Temperature Control Range5–75 °C (dependent on vessel type)
PAR IntensityUp to 3000 µmol photons·m⁻²·s⁻¹ (configurable per wavelength)
Light SourcesRed, Blue, White LEDs (single/dual/multi-spectral)
Fluorescence DetectionDual-modulation chlorophyll fluorometer (F₀, Fₘ, Fₘ′, QY, ΦPSII)
Optical DensityOD₆₈₀ & OD₇₂₀ via PIN photodiode + bandpass filter (665–750 nm)
Gas ControlOptional GMS high-precision gas mixing system (N₂, air, CO₂, O₂)
pH/DO/CO₂ SensingOptional calibrated electrochemical sensors
Pump CapacityUp to 8 per unit (PP600 peristaltic pumps)
SoftwarePSI FMT150 Control Suite (Basic & Advanced editions, FDA 21 CFR Part 11–compliant audit trail optional)
ComplianceCE-marked
Show next