| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-1 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HQG-3 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven (Beijing) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HFCT-1 |
| Structural Design | Horizontal Configuration |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Class | General-Purpose TGA-DTA/DSC Hybrid |
| Temperature Range | RT to 900 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Uncertainty) | 0.1 K |
| Dynamic Weight Range | 1–300 mg |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | 0.1 μg |
| Heating/Cooling Rate | Up to 300 K/min |
| Maximum Load Capacity | 5 g |
| DSC Signal Range | ±500 mW |
| DSC Resolution | ±0.1 μW |
| DSC Accuracy | ±0.1 μW |
| DTA Voltage Range | ±10–±2000 μV |
| DTA Resolution | 0.01 μV |
| TG Noise Level | <0.1 μg |
| Atmosphere Control | Dual-channel Mass Flow Controllers (MFCs), Programmable Gas Switching, Compatible with Inert, Oxidizing, Reducing, and Vacuum (Optional) |
| Crucible Standard | Al₂O₃ |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HWD-50g/500g |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.1 K |
| Dynamic Weighing Range | 10–50 g |
| Balance Sensitivity | 1000 µg |
| Mass Accuracy | 0.01% (100 ppm) |
| Heating/Cooling Rate | 0.1–40 K/min |
| Maximum Sample Mass | 500 g |
| Baseline Drift | ≤0.01% over 60 min |
| Weight Resolution | 1 mg |
| Weight Noise | <1 mg |
| Gas Control | Triple Mass Flow Controllers (MFCs) |
| Crucible Dimensions | Ceramic, Ø80 mm × H70 mm |
| Water Vapor Generator Output | 0.01–1000 mL/min (±0.01 mL/min resolution) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-2 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-1 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-4 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HTF |
| Price Range | USD 70,000–110,000 |
| Sample Capacity | Single sample per run |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (selectable) |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass | 5 g |
| Pressure Control Range | 0.1–5 MPa (at elevated temperature) |
| Pressure Control Precision | ±0.02 MPa |
| Steam Generation Range | 0.01–1000 mL/min (saturated water vapor, computer-controlled) |
| Atmosphere Control | Triple independent mass flow-controlled gas lines with automated switching and stabilization |
| Crucible Options | Standard ceramic crucible (Ø80 mm × H70 mm), compatible with sample masses up to 50 g |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-2 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Vacuum Option | Up to 2.5 × 10⁻² Pa (with optional vacuum unit) |
| Standard Crucibles | Al₂O₃ (Φ5×4 mm, Φ5×8 mm, Φ8×10 mm, Φ18×8 mm, Φ18×15 mm, Φ18×20 mm) |
| Optional Crucibles | Aluminum, Graphite, Quartz, Platinum |
| Dual Thermocouples | Furnace Temp + Sample Temp Monitoring |
| Isothermal Hold Capability | Up to 72 h at any temperature within range |
| Data Output Modes | TG, DTG, DDTG, % Mass Loss, Kinetic Parameter Derivation, Multi-Curve Overlay & Differential Analysis |
| Software Calibration Support | Temperature & Mass calibration using certified reference materials |
| Optional Accessories | Isothermal Controller, GC/MS Transfer Interface (heated, 200 °C max), Heated Transfer Line, Corrosion-Resistant MFC Atmosphere System |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose |
| Temperature Range | Ambient to 1000 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–80 K/min |
| Solid Feed Delivery Time | <1.0 s |
| Solid Feed Mass | 10–50 mg |
| System Response Delay | <2.0 s |
| Reactor Inner Diameter | ~20 mm |
| Reactor Height | <150 mm |
| Bed Material | Quartz Sand (d₅₀ = 200–300 µm) |
| Bed Height | 20–50 mm |
| Reproducibility Error | <10% |
| Gas Flow Controllers | 3 × Mass Flow Controllers (Air, H₂, CO, CO₂, CH₄ |
| Temperature Control | 0–1000 °C with Integrated Thermocouples |
| Pressure Monitoring | 0–1 atm |
| Hot-Gas Filtration | Ceramic/Fibrous Filter (Effective for Tar Retention) |
| Gas Analysis | 4-Channel In-Line Sensors (H₂: 0–3%, CO: 0–10%, CO₂: 0–3%, CH₄: 0–3%) |
| Pneumatic Switching | 11-Port Automated Solenoid Valve Bank (Programmable Dwell/Transition Times) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | HKG |
| Price Range | USD 14,000–28,000 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 950 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 10 K/min (standard), configurable up to 300 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤0.01% of full scale |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HQG-4 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HTG-3 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 K |
| Dynamic Weighing Range | 0.01 mg – 5 g |
| Balance Sensitivity | 0.1 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1 – 100 K/min |
| Maximum Sample Mass | 5 g |
| Baseline Repeatability | 0.01 mg |
| Baseline Drift | 0.01 mg |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HTF-50 |
| Price Range | USD 70,000–112,000 (FOB Beijing) |
| Test Environment | High-Pressure Atmosphere |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Dedicated TGA platform |
| Temperature Range | Ambient to 950 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Accuracy | ±0.1 K |
| Dynamic Weighing Range | 1 mg–200 mg or 0–5 g (user-selectable) |
| Balance Sensitivity | 10 µg |
| Mass Accuracy | 0.1 µg |
| Heating/Cooling Rate | 0.1–30 K/min |
| Maximum Sample Mass Capacity | 500 g |
| Baseline Drift | ≤0.01% (full-scale) |