| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HQSC |
| Instrument Type | Heat-Flow DSC |
| Sample Capacity | Single-position with 40-position Auto-sampler |
| Temperature Control Modes | Ramp, Isothermal, Cooling |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability | ±0.1 °C |
| DSC Resolution | ±0.1 µW |
| Power Noise | ±0.1 µW |
| Temperature Resolution | ±0.1 °C |
| Baseline Correction | Adaptive, User-Selectable |
| Calibration Standards Included | In, Sn, Pb, Zn, Al |
| Gas Control | Dual-channel MFC, 0–200 mL/min (customizable) |
| Crucible Options | Al₂O₃, High-Purity Al (standard) |
| Optional Accessories | Cryogenic Cooling (LN₂ auto-fill for −150 °C), GC/MS Interface, Isothermal Band (RT–200 °C), RFID/Barcode Sample Tray Recognition |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA |
| Model | HQC-2 |
| Sample Capacity | Single |
| Temperature Range | RT to 1250 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | 0 mW to ±500 mW |
| DSC Precision | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching |
| Optional Vacuum System | 2.5×10⁻² Pa |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, Graphite, Quartz, Platinum |
| Isothermal Capability | Up to 72 h at any temperature within range |
| Software Features | Oxidation Induction Time (OIT) analysis, Crystallization Kinetics modeling, Step-Cooling Curve generation, ASTM/ISO-compliant thermal data processing, GLP/GMP-ready audit trail (optional), User-defined formula integration support |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | −150 to 1550 °C (with liquid nitrogen cooling) |
| Programmable Temperature Control | Heating, Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min (user-definable) |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Pressure Range | 0.1–10.0 MPa |
| Pressure Accuracy | ±0.002 MPa |
| Pressure Control Mode | Dynamic Pressure Regulation |
| Calorimetric Accuracy | ±1% (vs. certified metal standards) |
| Calibration Method | Multi-point Nonlinear Temperature Calibration |
| Atmosphere Options | Oxidizing, Reducing, Inert, Steam |
| Measurement Modes | Static, Dynamic, Variable Pressure & Gas Flow |
| Sensor Configurability | Interchangeable sensor modules |
| Software | Windows-based bilingual (EN/CN) control & analysis suite |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-3 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel MFC-controlled gas system (N₂, Ar, O₂, air |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy determination (multiple model algorithms), Tg identification, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition, calibration support (In, Sn, Pb standards) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Heat-Flow DSC |
| Model | HSC-3 |
| Sample Capacity | Single |
| Temperature Range | −100 °C to 680 °C (with manual liquid nitrogen cooling) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | 0 mW to ±500 mW |
| Temperature Stability | ±0.1 °C |
| DSC Resolution | ±0.1 µW |
| Power Noise | ±0.1 µW |
| Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controlled (10–200 mL/min, auto-switchable) |
| Crucible Options | Al₂O₃, high-purity Al (standard) |
| Calibration Standards Included | In, Sn, Pb, Zn, Al |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HQC |
| Measurement Mode | DTA |
| Temperature Range | RT–1150°C / 1250°C / 1450°C / 1550°C (configurable) |
| Temperature Accuracy | ±0.1°C |
| Temperature Stability | ±0.1°C |
| Heating/Cooling Rate | 0.1–100°C/min |
| Programmable Control | Isothermal hold (up to 72 h), ramp, step-cooling |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Range | ±1 mW to ±500 mW |
| DSC Precision | ±0.1 µW |
| Atmosphere Control | Dual-channel MFC-controlled gas system (corrosion-resistant options available) |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Interface | Integrated LCD display with dual thermocouples (furnace + sample) |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, enthalpy integration, activation energy calculation (multiple algorithms), Tg determination, Cp calibration via reference standards (In, Sn, Pb) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-4 |
| Sample Capacity | Single |
| Temperature Range | –100 °C to 680 °C (with automated liquid nitrogen cooling) |
| Programmable Temperature Control Accuracy | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Repeatability) | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Isothermal, Heating Scan, Cooling Scan |
| DSC Signal Range | 0 to ±500 mW |
| DSC Minimum Detectable Heat Flow | ±0.1 µW |
| DSC Power Noise Level | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controlled gas system (10–200 mL/min), auto-switchable |
| Standard Crucibles | Al₂O₃, high-purity aluminum (0.06 mL capacity) |
| Optional Crucibles | Sealed aluminum (solid/liquid), ZrO₂, quartz, graphite, Pt/Rh |
| Display | Large-character LCD with dual thermocouple readout (sample + furnace) |
| Connectivity | RS232, USB interface |
| Software Features | Automated baseline correction, thermal event identification (Tg, Tm, Tc, OIT), enthalpy integration, calibration with certified standards (In, Sn, Pb, Zn, Al), GLP-compliant report generation, remote diagnostics and parameter adjustment via internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HKR |
| Price Range | USD 7,000–14,000 |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Precision | ±10 µW |
| DTA Signal Range | ±10 µV to ±2000 µV |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Isothermal Controller Range (optional) | 0–400 °C |
| Standard Crucibles | Al₂O₃, 0.06 mL or 0.12 mL |
| Optional Crucibles | Aluminum, Graphite, Quartz |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HCR |
| Price Range | USD 10,800–15,000 (FOB Beijing) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Temperature Range | RT to 1150 °C (HCR-1), RT to 1250 °C (HCR-2), RT to 1450 °C (HCR-3), RT to 1550 °C (HCR-4) |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Operating Mode | Fully Automated |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Dynamic heating, isothermal stabilization |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±1 mW to ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| Voltage Input Range | ±10 µV to ±2000 µV (auto-ranging) |
| Vacuum Capability (Optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any setpoint within operating range |
| Calibration Standards Supported | Indium, tin, lead (for temperature and enthalpy calibration) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-2 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Sensitivity | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| DSC Measurement Range | ±1–±500 mW |
| DSC Precision | ±0.1 μW |
| Sample Capacity | Single-sample configuration |
| Control Mode | Manual sample loading |
| Thermal Program Modes | Ramp heating, isothermal hold (up to 72 h at any temperature within range) |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Signal Output Range | ±10–±2000 μV (auto-ranging) |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Interface | Integrated LCD display showing furnace temperature, sample temperature, gas status, and real-time signal |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy estimation (multiple algorithms), Tg determination, specific heat comparison method, calibration support (In, Sn, Pb), screenshot capture at arbitrary timestamps, user-defined formula implementation |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HSC-2 / HSC-3 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −30 °C to 680 °C (HSC-2, mechanical cooling) / −100 °C to 680 °C (HSC-3, liquid nitrogen cooling) |
| Programmable Heating/Cooling Rate | 0.1–100 K/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| DSC Sensitivity (Minimum Detectable Heat Flow) | ±0.1 μW |
| Baseline Noise | ±0.1 μW |
| Power Accuracy | ±0.1 μW |
| Standard Crucibles | Alumina (Φ5 mm × 4 mm) or Aluminum (Φ5 mm × 4 mm) |
| Optional Crucibles | Hermetic aluminum crucibles (with crimping tool for solids/liquids) |
| Atmosphere Control | Dual-channel mass flow controllers (corrosion-resistant variants available on request) |
| Heated Zone Temperature Range | 0–400 °C |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | −150 °C to 680 °C (with liquid nitrogen cooling) |
| Programmable Thermal Control | Heating, Isothermal Hold, Cooling |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min (user-definable) |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C |
| Pressure Range | 0.1–10.0 MPa |
| Pressure Accuracy | ±0.002 MPa |
| Pressure Control Mode | Dynamic Real-Time Regulation |
| Calibration | Multi-Point Nonlinear Temperature & Enthalpy Calibration |
| Atmosphere Options | Oxidizing, Reducing, Inert, Steam |
| Software | Windows-based Dual-Language (EN/CN) Control & Analysis Suite |
| Compliance | ASTM E793, ASTM E1269, ISO 11357-1 to -7, USP <1159>, GLP-Ready Audit Trail |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HQC-4 |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| DSC Mode | Heat-Flow Type |
| Sample Capacity | Single |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Programmable Thermal Modes | Heating, Isothermal, Cooling |
| DSC Measurement Range | 0 to ±500 mW |
| DSC Sensitivity | ±0.1 μW |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| Signal Range | ±10 μV to ±2000 μV (auto-ranging) |
| Atmosphere Control | Dual-channel Mass Flow Controller (MFC), corrosion-resistant options available |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, Graphite, Quartz, Platinum |
| Interface | Integrated LCD display with dual thermocouples (furnace + sample) |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, enthalpy integration, activation energy calculation (multiple algorithms), Tg determination, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | HQC-1 |
| Sample Capacity | Single-sample |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Temperature Range | Ambient to 1150 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| DTA Signal Range | ±1 μV to ±2000 μV (auto-ranging) |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| DSC Measurement Range | 0 to ±500 mW |
| DSC Sensitivity | ±0.1 μW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching |
| Optional Vacuum Capability | 2.5×10⁻² Pa (with vacuum pump package) |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1200 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 °C/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability (Drift) | ±0.1 °C |
| Minimum Heat Flow Resolution | 0.1 µW |
| Power Noise Level | <0.1 µW |
| Crucible Volume | 0.06–0.12 mL |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Henven Scientific Instrument Co., Ltd. |
| Type | Differential Scanning Calorimeter (DSC) |
| Model | HYD |
| Sample Capacity | 1 |
| Temperature Range | Ambient to 500 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| DSC Signal Range | 0 to ±500 mW |
| DSC Resolution | ±0.1 µW |
| DSC Accuracy | ±0.1 µW |
| Crucible Volume | 0.06 mL or 0.12 mL |
| Atmosphere Control | Dual-gas (N₂/O₂) with Mass Flow Controllers (MFCs) |
| Programmable Thermal Profiles | Isothermal hold, linear ramp, gas-switch-triggered transition |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-4 |
| Sample Capacity | Single-sample configuration |
| Temperature Range | Ambient to 1550 °C |
| Programmable Temperature Control | Heating and Isothermal hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| Heating/Cooling Rate | 0.1–100 °C/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV (RMS) |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | In, Sn, Pb, and user-defined reference materials |
| Optional Accessories | GC/MS transfer line (thermostatted to 200 °C), ceramic/alumina/graphite/quartz/platinum crucibles (0.06 mL & 0.12 mL standard) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-2 |
| Sample Capacity | Single |
| Temperature Range | −30 °C to 680 °C (with optional mechanical cryo-cooling unit) |
| Programmable Temperature Control Accuracy | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Repeatability) | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Heating, Isothermal, Cooling |
| DSC Signal Range | ±500 mW |
| DSC Minimum Resolution | ±0.1 µW |
| DSC Power Noise | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow-controlled gas system (10–200 mL/min), software-switchable |
| Standard Crucibles | Al₂O₃, high-purity Al (0.06 mL capacity) |
| Optional Crucibles | Sealed Al (liquid/solid), ZrO₂, quartz, graphite, Pt/Rh |
| Display | Large-character Chinese LCD with dual thermocouples (sample + furnace) |
| Connectivity | RS232, USB interface |
| Software Features | Automated baseline correction, thermal event annotation (Tg, Tm, Tc, OIT), enthalpy integration, calibration with certified standards (In, Sn, Pb, Zn, Al), auto-report generation (DSC & OIT), remote diagnostics and parameter tuning via internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Model | HSC-1 |
| Sample Capacity | Single |
| Temperature Range | Ambient to 680 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0 to ±500 mW |
| DSC Minimum Resolution | ±0.1 µW |
| DSC Power Noise | ±0.1 µW |
| DSC Power Accuracy | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow-controlled gas system (10–200 mL/min), auto-switchable |
| Standard Crucibles | Al₂O₃, high-purity Al |
| Optional Crucibles | Sealed Al (liquid/solid), ZrO₂, quartz, graphite, Pt/Rh |
| Crucible Volume | 0.06 mL |
| Cooling Method | Forced-air |
| Display | Large-character LCD with dual thermocouples (sample + furnace) |
| Interface | RS232 + USB |
| Software Features | Auto-baseline correction, calibration with certified standards (In, Sn, Pb, Zn, Al), automated report generation (Tg, Tm, ΔH, OIT), remote diagnostics & parameter tuning via Internet |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HSC |
| Price Range | USD 12,000–25,500 (FOB) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | Ambient to +680 °C |
| Programmable Temperature Control | Heating, Isothermal hold, Cooling |
| Temperature Accuracy | ±0.1 °C |
| Operating Mode | Fully automated |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, isothermal, dynamic cooling |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C over 30 min |
| DSC Noise Level | ±0.1 μW |
| DSC Resolution | ±0.1 μW |
| Baseline Repeatability | <0.5 μW over 24 h |
| Atmosphere Control | Dual-channel mass flow controlled (MFC), 10–200 mL/min per channel, software-switchable gas routing |
| Standard Crucibles | Al₂O₃, high-purity Al (0.06 mL capacity) |
| Optional Crucibles | Sealed Al (solid/liquid), ZrO₂, quartz, graphite, Pt/Rh |
| Interface | RS-232 & USB 2.0 |
| Remote Diagnostics & Calibration Support | Yes (via secure TCP/IP connection) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCR-1 |
| Sample Capacity | Single-sample |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Temperature Range | Ambient to 1150 °C |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| Scan Modes | Dynamic heating, isothermal hold |
| DSC Measurement Range | ±1–±500 mW |
| DSC Sensitivity | ±0.1 μW |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| Signal Range | ±10–±2000 μV (auto-ranging) |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | Indium, tin, lead |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HQC-3 |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | RT to 1450 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | 0 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), auto-switching, corrosion-resistant options available |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |