Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHCT-1
Price RangeUSD 12,500 – 18,000 (FOB Beijing)
Temperature RangeAmbient to 1150 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHCT-2
Price RangeUSD 14,000 – 20,000 (FOB Beijing)
Temperature RangeAmbient to 1250 °C
Heating Rate0.1–100 °C/min (programmable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelHCT-4
Heating Rate0.1–100 °C/min
Temperature RangeAmbient to 1550 °C
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (customizable for corrosive gases)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQT-3
Price RangeUSD 19,500 – 26,000 (FOB Beijing)
Temperature RangeAmbient to 1450 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelHT-1700
ConfigurationTG-DSC Coupled System
Temperature RangeAmbient to 1700 °C
Heating/Cooling Rate0.1–200 °C/min
Temperature Stability±0.1 °C
Maximum Sample Mass200 mg (extendable to 5 g with optional support rods)
Balance Sensitivity0.1 µg
Thermogravimetric Noise<0.1 µg
DSC Range±500 mW
DSC Precision±0.1 µW
DSC Response Ratio>100 mW/K
Enthalpy Accuracy±0.1% (using In calibration)
DTA Range±2000 µV
DTA Resolution0.01 µV
Atmosphere OptionsOxidizing, Reducing, Inert, Vacuum, Steam
Standard CruciblesAl₂O₃ (0.06 mL and 0.12 mL)
Optional CruciblesAl, Graphite, Quartz, Pt
Vacuum & Gas PurgeIntegrated automated vacuum/purge system with programmable gas switching
Temperature CalibrationMulti-point non-linear calibration using certified reference materials (In, Zn, Sn, Pb, Al, Cu)
Control ProgramUp to 64 segments, 999 cycles, power-fail data retention
Data ExportASCII, MS Excel-compatible CSV, real-time multi-curve overlay, differential analysis, kinetic modeling (e.g., Kissinger, Ozawa-Flynn-Wall)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQT-2
Price RangeUSD 18,000 – 25,000 (FOB Beijing)
Temperature RangeAmbient to 1250 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Max Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQT-4
Price RangeUSD 19,500 – 27,800 (FOB Beijing)
Temperature RangeAmbient to 1550 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)-based gas delivery system
TG Resolution0.1 μg
TG Noise Level< 0.1 μg
DSC Range±1 mW to ±500 mW
DSC Sensitivity±0.1 μW
DTA Range±10 μV to ±2000 μV
DTA Resolution0.01 μV
Vacuum Capability2.5×10⁻² Pa (with optional vacuum pump)
Isothermal Hold DurationUp to 72 h at any temperature within range
Crucible OptionsAl₂O₃ (0.06 mL / 0.12 mL), Al, graphite, quartz, Pt
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic
ModelHQST-1/2
ConfigurationTG-DSC Coupled System
Temperature RangeUp to 1550 °C (High-Temperature Furnace Option)
Heating Rate0.1–100 °C/min
Temperature Stability±0.1 °C
Max Sample Mass200 mg
Atmosphere ControlOxidizing, Reducing, Inert, Vacuum
Sample Capacity24-Position Automated Carousel
Positioning Accuracy≤±0.05 mm
Balance TypeMechanical Zero-Position Photoelectric Microbalance
Mass Sensitivity0.1 μg
TG Noise Level<0.1 μg
DSC Range±500 mW
DSC Sensitivity±0.1 μW
DSC Enthalpy Accuracy±0.1% (using In standard)
DTA Range±2000 μV
DTA Resolution0.01 μV
Standard CruciblesAl₂O₃ (0.06 mL / 0.12 mL)
Optional CruciblesAl, Graphite, Quartz, Pt
Optional AccessoriesMulti-gas Mixing System, Steam Generator, UV Curing Module, Real-time Visual Monitoring Kit, FTIR/MS/GC Coupling Interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQT-1
Price RangeUSD 16,800 – 23,800 (FOB Beijing)
Temperature RangeAmbient to 1150 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHCT-3
Temperature RangeAmbient to 1450 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Max Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
DSC Range±1 mW to ±500 mW
DSC Sensitivity±0.1 μW
TG Measurement Range1–200 mg
TG Resolution0.1 μg
TG Noise<0.1 μg
Vacuum Capability2.5×10⁻² Pa (with optional vacuum pump)
DTA Range±10 μV to ±2000 μV
DTA Resolution0.01 μV
Crucible OptionsAl₂O₃ (0.06 mL / 0.12 mL), Al, graphite, quartz, Pt