Empowering Scientific Discovery

Beijing Hengjiu Experimental Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelHQSC
Instrument TypeHeat-Flow DSC
Sample CapacitySingle-position with 40-position Auto-sampler
Temperature Control ModesRamp, Isothermal, Cooling
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 K/min
Temperature Precision±0.1 °C
DSC Signal Range±500 mW
Temperature Stability±0.1 °C
DSC Resolution±0.1 µW
Power Noise±0.1 µW
Temperature Resolution±0.1 °C
Baseline CorrectionAdaptive, User-Selectable
Calibration Standards IncludedIn, Sn, Pb, Zn, Al
Gas ControlDual-channel MFC, 0–200 mL/min (customizable)
Crucible OptionsAl₂O₃, High-Purity Al (standard)
Optional AccessoriesCryogenic Cooling (LN₂ auto-fill for −150 °C), GC/MS Interface, Isothermal Band (RT–200 °C), RFID/Barcode Sample Tray Recognition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDTA
ModelHQC-2
Sample CapacitySingle
Temperature RangeRT to 1250 °C
Programmable Temperature ControlHeating & Isothermal Hold
Temperature Accuracy±0.1 °C
Temperature Stability±0.1 °C
Heating/Cooling Rate0.1–80 K/min
DTA Signal Range±10 µV to ±2000 µV (auto-ranging)
DTA Resolution0.01 µV
DTA Noise Level<0.01 µV
DSC Measurement Range0 mW to ±500 mW
DSC Precision±0.1 µW
Atmosphere ControlDual-channel mass flow controller (MFC), programmable gas switching
Optional Vacuum System2.5×10⁻² Pa
Standard CruciblesAl₂O₃ (0.06 mL or 0.12 mL)
Optional CruciblesAluminum, Graphite, Quartz, Platinum
Isothermal CapabilityUp to 72 h at any temperature within range
Software FeaturesOxidation Induction Time (OIT) analysis, Crystallization Kinetics modeling, Step-Cooling Curve generation, ASTM/ISO-compliant thermal data processing, GLP/GMP-ready audit trail (optional), User-defined formula integration support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDSC
Temperature Range−150 to 1550 °C (with liquid nitrogen cooling)
Programmable Temperature ControlHeating, Isothermal Hold
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–50 K/min (user-definable)
Temperature Precision±0.1 °C
Temperature Stability±0.1 °C
Pressure Range0.1–10.0 MPa
Pressure Accuracy±0.002 MPa
Pressure Control ModeDynamic Pressure Regulation
Calorimetric Accuracy±1% (vs. certified metal standards)
Calibration MethodMulti-point Nonlinear Temperature Calibration
Atmosphere OptionsOxidizing, Reducing, Inert, Steam
Measurement ModesStatic, Dynamic, Variable Pressure & Gas Flow
Sensor ConfigurabilityInterchangeable sensor modules
SoftwareWindows-based bilingual (EN/CN) control & analysis suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHCT-1
Price RangeUSD 12,500 – 18,000 (FOB Beijing)
Temperature RangeAmbient to 1150 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHTG-1
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeGeneral-Purpose
Temperature RangeRoom Temperature to 1150 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 K
Dynamic Weighing Range0.01 mg – 5 g
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1 – 100 K/min
Maximum Sample Mass5 g
Baseline Repeatability0.01 mg
Baseline Drift0.01 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQG-3
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeGeneral-Purpose TGA
Temperature RangeRoom Temperature to 1450 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 K
Dynamic Weighing Range0.01 mg – 5 g
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1 – 100 K/min
Maximum Sample Mass5 g
Baseline Repeatability0.01 mg
Baseline Drift0.01 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven (Beijing)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHFCT-1
Structural DesignHorizontal Configuration
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument ClassGeneral-Purpose TGA-DTA/DSC Hybrid
Temperature RangeRT to 900 °C
Temperature Accuracy±0.1 °C
Temperature Precision (Uncertainty)0.1 K
Dynamic Weight Range1–300 mg
Balance Sensitivity0.1 μg
Mass Accuracy0.1 μg
Heating/Cooling RateUp to 300 K/min
Maximum Load Capacity5 g
DSC Signal Range±500 mW
DSC Resolution±0.1 μW
DSC Accuracy±0.1 μW
DTA Voltage Range±10–±2000 μV
DTA Resolution0.01 μV
TG Noise Level<0.1 μg
Atmosphere ControlDual-channel Mass Flow Controllers (MFCs), Programmable Gas Switching, Compatible with Inert, Oxidizing, Reducing, and Vacuum (Optional)
Crucible StandardAl₂O₃
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDTA (Differential Thermal Analysis)
ModelHCR-3
Sample CapacitySingle-sample
Temperature RangeAmbient to 1450 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 °C
Temperature Stability (Drift)≤0.1 °C
Heating/Cooling Rate0.1–100 K/min (user-definable)
DTA Signal Range±10 µV to ±2000 µV (auto-ranging)
DTA Resolution0.01 µV
DTA Noise Level<0.01 µV
DSC Measurement Range±1 mW to ±500 mW
DSC Sensitivity±0.1 µW
Atmosphere ControlDual-channel MFC-controlled gas system (N₂, Ar, O₂, air
Vacuum Option2.5×10⁻² Pa (with optional vacuum unit)
Isothermal Hold DurationUp to 72 h at any temperature within range
Standard CruciblesAl₂O₃ (0.06 mL or 0.12 mL)
Optional CruciblesAluminum, graphite, quartz, platinum
Software FeaturesOxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy determination (multiple model algorithms), Tg identification, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition, calibration support (In, Sn, Pb standards)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeHeat-Flow DSC
ModelHSC-3
Sample CapacitySingle
Temperature Range−100 °C to 680 °C (with manual liquid nitrogen cooling)
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 °C/min
Temperature Precision±0.1 °C
DSC Signal Range0 mW to ±500 mW
Temperature Stability±0.1 °C
DSC Resolution±0.1 µW
Power Noise±0.1 µW
Power Accuracy±0.1 µW
Atmosphere ControlDual-channel mass flow controlled (10–200 mL/min, auto-switchable)
Crucible OptionsAl₂O₃, high-purity Al (standard)
Calibration Standards IncludedIn, Sn, Pb, Zn, Al
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelHWD-50g/500g
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeDedicated TGA System
Temperature RangeRT to 1100 °C
Temperature Accuracy±0.1 °C
Temperature Uniformity±0.1 K
Dynamic Weighing Range10–50 g
Balance Sensitivity1000 µg
Mass Accuracy0.01% (100 ppm)
Heating/Cooling Rate0.1–40 K/min
Maximum Sample Mass500 g
Baseline Drift≤0.01% over 60 min
Weight Resolution1 mg
Weight Noise<1 mg
Gas ControlTriple Mass Flow Controllers (MFCs)
Crucible DimensionsCeramic, Ø80 mm × H70 mm
Water Vapor Generator Output0.01–1000 mL/min (±0.01 mL/min resolution)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHQG-2
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeGeneral-Purpose
Temperature RangeRoom Temperature to 1250 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 K
Dynamic Weighing Range0.01 mg to 5 g
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1–100 K/min
Maximum Sample Mass5 g
Baseline Repeatability0.01 mg
Baseline Drift0.01 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHQG-1
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeGeneral-Purpose
Temperature RangeRoom Temperature to 1150 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 K
Dynamic Weighing Range0.01 mg – 5 g
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1 – 100 K/min
Maximum Sample Mass5 g
Baseline Repeatability0.01 mg
Baseline Drift0.01 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHCT-2
Price RangeUSD 14,000 – 20,000 (FOB Beijing)
Temperature RangeAmbient to 1250 °C
Heating Rate0.1–100 °C/min (programmable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelHCT-4
Heating Rate0.1–100 °C/min
Temperature RangeAmbient to 1550 °C
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (customizable for corrosive gases)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHTS-1400
Temperature RangeAmbient to 1400 °C (High-Temp Zone), –20 °C to 100 °C (Liquid Quench Zone)
Max Ramp Rate40 °C/min
Control Precision±0.5 °C (Furnaces), ±0.1 °C (Water Bath)
Transfer Time≤2 s
Vacuum System≤10 Pa (4 L/s pumping speed)
Gas Control3-channel MFC (0–100 mL/min, N₂/Ar/He)
Sample Capacity≤30 mm cube, any geometry, compatible up to 1400 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHQT-3
Price RangeUSD 19,500 – 26,000 (FOB Beijing)
Temperature RangeAmbient to 1450 °C
Heating Rate0.1–100 °C/min (user-definable)
Temperature Stability±0.1 °C
Maximum Sample Mass5 g
Atmosphere ControlDual-channel mass flow controller (MFC)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelHQC
Measurement ModeDTA
Temperature RangeRT–1150°C / 1250°C / 1450°C / 1550°C (configurable)
Temperature Accuracy±0.1°C
Temperature Stability±0.1°C
Heating/Cooling Rate0.1–100°C/min
Programmable ControlIsothermal hold (up to 72 h), ramp, step-cooling
DTA Signal Range±10 µV to ±2000 µV (auto-ranging)
DTA Resolution0.01 µV
DTA Noise Level<0.01 µV
DSC Range±1 mW to ±500 mW
DSC Precision±0.1 µW
Atmosphere ControlDual-channel MFC-controlled gas system (corrosion-resistant options available)
Vacuum Option2.5×10⁻² Pa (with optional vacuum unit)
Standard CruciblesAl₂O₃ (0.06 mL or 0.12 mL)
Optional CruciblesAluminum, graphite, quartz, platinum
InterfaceIntegrated LCD display with dual thermocouples (furnace + sample)
Software FeaturesOxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, enthalpy integration, activation energy calculation (multiple algorithms), Tg determination, Cp calibration via reference standards (In, Sn, Pb)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHTG-4
Operating EnvironmentAmbient Pressure
Sample CapacitySingle Sample
Instrument TypeGeneral-Purpose TGA
Temperature RangeRoom Temperature to 1550 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 K
Dynamic Weighing Range0.01 mg – 5 g
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1 – 100 K/min
Maximum Sample Mass5 g
Baseline Repeatability0.01 mg
Baseline Drift0.01 mg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDSC
ModelHSC-4
Sample CapacitySingle
Temperature Range–100 °C to 680 °C (with automated liquid nitrogen cooling)
Programmable Temperature Control Accuracy±0.1 °C
Temperature Accuracy±0.1 °C
Temperature Precision (Repeatability)±0.1 °C
Heating/Cooling Rate0.1–100 °C/min
Scan ModesIsothermal, Heating Scan, Cooling Scan
DSC Signal Range0 to ±500 mW
DSC Minimum Detectable Heat Flow±0.1 µW
DSC Power Noise Level±0.1 µW
DSC Power Accuracy±0.1 µW
Atmosphere ControlDual-channel mass flow controlled gas system (10–200 mL/min), auto-switchable
Standard CruciblesAl₂O₃, high-purity aluminum (0.06 mL capacity)
Optional CruciblesSealed aluminum (solid/liquid), ZrO₂, quartz, graphite, Pt/Rh
DisplayLarge-character LCD with dual thermocouple readout (sample + furnace)
ConnectivityRS232, USB interface
Software FeaturesAutomated baseline correction, thermal event identification (Tg, Tm, Tc, OIT), enthalpy integration, calibration with certified standards (In, Sn, Pb, Zn, Al), GLP-compliant report generation, remote diagnostics and parameter adjustment via internet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelHT-1700
ConfigurationTG-DSC Coupled System
Temperature RangeAmbient to 1700 °C
Heating/Cooling Rate0.1–200 °C/min
Temperature Stability±0.1 °C
Maximum Sample Mass200 mg (extendable to 5 g with optional support rods)
Balance Sensitivity0.1 µg
Thermogravimetric Noise<0.1 µg
DSC Range±500 mW
DSC Precision±0.1 µW
DSC Response Ratio>100 mW/K
Enthalpy Accuracy±0.1% (using In calibration)
DTA Range±2000 µV
DTA Resolution0.01 µV
Atmosphere OptionsOxidizing, Reducing, Inert, Vacuum, Steam
Standard CruciblesAl₂O₃ (0.06 mL and 0.12 mL)
Optional CruciblesAl, Graphite, Quartz, Pt
Vacuum & Gas PurgeIntegrated automated vacuum/purge system with programmable gas switching
Temperature CalibrationMulti-point non-linear calibration using certified reference materials (In, Zn, Sn, Pb, Al, Cu)
Control ProgramUp to 64 segments, 999 cycles, power-fail data retention
Data ExportASCII, MS Excel-compatible CSV, real-time multi-curve overlay, differential analysis, kinetic modeling (e.g., Kissinger, Ozawa-Flynn-Wall)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHTF
Price RangeUSD 70,000–110,000
Sample CapacitySingle sample per run
Instrument TypeDedicated TGA platform
Temperature RangeAmbient to 950 °C
Temperature Accuracy±0.1 °C
Temperature Stability±0.1 K
Dynamic Weighing Range1 mg–200 mg or 0–5 g (selectable)
Balance Sensitivity0.1 µg
Mass Accuracy0.1 µg
Heating/Cooling Rate0.1–30 K/min
Maximum Sample Mass5 g
Pressure Control Range0.1–5 MPa (at elevated temperature)
Pressure Control Precision±0.02 MPa
Steam Generation Range0.01–1000 mL/min (saturated water vapor, computer-controlled)
Atmosphere ControlTriple independent mass flow-controlled gas lines with automated switching and stabilization
Crucible OptionsStandard ceramic crucible (Ø80 mm × H70 mm), compatible with sample masses up to 50 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeReaction Calorimeter
Intelligence LevelIntelligent Control
Temperature RangeAmbient to 1600 °C
Temperature Detection Limit1600 °C
Temperature Resolution±1 °C
Temperature Stability±1 °C
Precision±1 °C
Heat Capacity Calibration Reference12,000 kcal (coal-calorimetry equivalent)
Sample Mass5 g
Heating ElementSilicon Molybdenum (MoSi₂) Rod
Heating Rate0.1–100 °C/min
Power Measurement Range±2000 mW
Minimum Power Resolution0.1 µW
Power Noise Floor<0.1 µW
Electrical Supply220 V AC, 3000 W
Atmosphere ControlDual-gas inlet with mass flow control (max. 5 L/min per channel)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelHKR
Price RangeUSD 7,000–14,000
Temperature RangeAmbient to 1150 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–100 K/min
DSC Measurement Range±1 mW to ±500 mW
DSC Precision±10 µW
DTA Signal Range±10 µV to ±2000 µV
DTA Resolution0.01 µV
DTA Noise Level<0.01 µV
Vacuum Capability (optional)2.5×10⁻² Pa
Isothermal Controller Range (optional)0–400 °C
Standard CruciblesAl₂O₃, 0.06 mL or 0.12 mL
Optional CruciblesAluminum, Graphite, Quartz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHenven
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelHCR
Price RangeUSD 10,800–15,000 (FOB Beijing)
Sample CapacitySingle-sample configuration
Instrument TypeDifferential Thermal Analysis (DTA)
Temperature RangeRT to 1150 °C (HCR-1), RT to 1250 °C (HCR-2), RT to 1450 °C (HCR-3), RT to 1550 °C (HCR-4)
Programmable Temperature ControlHeating and Isothermal Hold
Temperature Accuracy±0.1 °C
Operating ModeFully Automated
Heating/Cooling Rate0.1–100 °C/min
Scan ModesDynamic heating, isothermal stabilization
Temperature Precision±0.1 °C
DSC Signal Range±1 mW to ±500 mW
Temperature Stability (Drift)≤0.1 °C over 24 h
DTA Resolution0.01 µV
DTA Noise Level<0.01 µV
Voltage Input Range±10 µV to ±2000 µV (auto-ranging)
Vacuum Capability (Optional)2.5×10⁻² Pa
Atmosphere ControlDual-channel mass flow controller (MFC)-based gas delivery with automatic switching
Standard CruciblesAl₂O₃ (0.06 mL or 0.12 mL)
OptionalAluminum, graphite, quartz, platinum
Isothermal DurationUp to 72 h at any setpoint within operating range
Calibration Standards SupportedIndium, tin, lead (for temperature and enthalpy calibration)