BrandHORIBA
OriginJapan
ModelW-20XD Series (Outdoor Deployment)
Instrument TypePortable Submersible Data Logger
Measurement PrincipleElectrochemical & Physical Sensor Array (pH, DO, EC, ORP, Turbidity, Depth, Temp, Salinity, TDS, Seawater Specific Gravity, Ion-Selective Electrodes)
pH Range0–14
pH Accuracy±0.1 pH
pH Repeatability±0.05 pH
pH Resolution0.01 pH
Dissolved Oxygen Range0–19.99 mg/L
DO Accuracy±0.2 mg/L
Conductivity Range0–9.99 S/m
Conductivity Accuracy±3% FS
Turbidity Range0–800 NTU
Turbidity Accuracy±5%
Depth Range0–100 m
Depth Accuracy±5%
Operating Temperature0–55 °C
Storage Temperature−5–60 °C
Waterproof RatingIP67 (Control Unit)
Continuous Logging Duration30 Days (2880 Data Points at 15-min Interval)
Max Submersion Depth100 m
Sensor HousingImpact-Resistant, Pressure-Compensated Enclosure
Data TransmissionRemote Wireless Upload (Optional Module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelU-50 Series
Instrument TypePortable
Measurement PrinciplesGlass Electrode (pH), Platinum Electrode (ORP), Polarographic Membrane (DO), AC 4-Electrode (Conductivity), LED/Tungsten Light Scattering (Turbidity), Pressure Transducer (Depth), Pt100 RTD (Temperature)
pH Range0–14
pH Resolution0.01
pH Accuracy±0.1
pH Repeatability±0.05
ORP Range−2000 to +2000 mV
ORP Resolution1 mV
ORP Accuracy±15 mV
DO Range0–50.0 mg/L
DO Resolution0.01 mg/L
DO Accuracy±0.2 mg/L (0–20 mg/L), ±0.5 mg/L (20–50 mg/L)
Conductivity Range0–10 S/m (0–100 mS/cm)
Conductivity Accuracy±1% F.S. (midpoint of dual-point calibration)
Turbidity Range0–1000 NTU (model-dependent)
Turbidity Resolution0.01 NTU (0–9.99 NTU)
Turbidity Accuracy±3% reading or ±0.1 NTU (whichever greater, per ISO 7027 or EPA Method 180.1)
Depth Range0–30 m
Depth Resolution0.05 m
Depth Accuracy±0.3 m
Temperature Range−10 to +55 °C
Temperature AccuracyJIS B-class Pt100 (±0.3 + 0.005
Detection Limit (pH/DO/Cond)0.1 unit or mg/L or mS/cm (context-dependent)
Measurement Time<10 seconds per parameter set
Data Storage10,000 measurement groups
Battery Life~70 hours (alkaline AA ×4, backlight off)
IP RatingIP67 (instrument), IP68 (probe, JIS Class 8)
Operating Temp−5 to +45 °C
Storage Temp−10 to +60 °C
Probe Cable LengthStandard 2 m (optional 10 m / 30 m)
Probe MaterialPPS, SUS316L, SUS304, FKM, PEEK, Ti, FEP, POM
Weight (Probe)~1800 g
Weight (Instrument)~800 g
Display320 × 240 monochrome LCD with backlight
CommunicationUSB
GPS12-channel (U-52G/U-53G/U-54G models only)
Language SupportEnglish, Japanese, Russian, Spanish, Portuguese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOPSA-150
Instrument TypeOnline Analyzer
Measurement PrincipleDual-Wavelength UV/VIS Absorption Spectrophotometry
Measurement WavelengthsUV: 253.7 nm, VIS: 546.1 nm
Measurement Range0–10 m⁻¹ SAC to 0–500 m⁻¹ SAC (0–0.1 Abs to 0–5.0 Abs)
Accuracy±2.0% F.S.
Repeatability±2.0% F.S.
Detection Limit0.01 m⁻¹ SAC
Resolution0.01 m⁻¹ SAC (0.0001 Abs)
Zero Drift CompensationRotating Cell-Length Adjustment System
Cleaning MethodContinuous Wiper-Based Optical Path Cleaning
Data StorageInternal memory (1-year hourly data) + CF card export
Output3-channel isolated 4–20 mA analog outputs
CommunicationRS-232C (19200 bps)
Sample Flow Rate2–20 L/min
Operating Temperature2–40 °C
Power SupplyAC 100–230 V ±10%, 50/60 Hz
EnclosureIndoor-rated, IP54-equivalent housing
Weight~100 kg
Dimensions460 W × 380 D × 1600 H mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelOPSA-150
Instrument TypeOnline Analyzer
Measurement PrincipleUV-Vis Absorption Spectrophotometry
WavelengthsUV: 254 nm, VIS: 546 nm
Measurement Range0–10 m⁻¹ SAC (0–0.1 Abs to 0–5.0 Abs equivalent)
Repeatability±2.0% F.S.
Resolution0.01 m⁻¹ SAC (0.0001 Abs)
Data LoggingInternal storage for 1 year (hourly intervals), CF card export supported
Cleaning MethodContinuous wiper-based optical cell cleaning
Flow Interruption DetectionStandard flow switch input
DisplayTouchscreen HMI with guided setup and dual-parameter display (COD + turbidity conversion)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginJapan
ModelF-73 Benchtop
Measurement RangepH 0.000–14.000
Accuracy±0.001 pH
Repeatability±0.001 pH ±1 digit
Resolution0.001 pH
ORP Range±1999.9 mV
ORP Resolution0.1 mV
ORP Repeatability±0.1 mV ±1 digit
Ion Concentration Range0.00 µg/L–999 g/L (mol/L)
Ion Repeatability±0.5% F.S. ±1 digit
Temperature Range−30.0–130.0 °C
Temp Resolution0.1 °C
Temp Repeatability±0.1 °C ±1 digit
Data Storage Capacity2000 measurements
ComplianceJIS, USP <645>, EP 2.2.38, JP XVI, ChP
Power SupplyAC adapter 100–240 V, 50/60 Hz
Power Consumption~9.8 VA
Weight700 g