| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | pH-33 |
| Instrument Type | Pen-style |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| IP Rating | IP67 |
| Electrode Type | Integrated flat-surface pH electrode |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine compliance with ISO 8655, ASTM D1293, and EPA Method 150.1 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH (after calibration, measured in standard buffer solutions) |
| Calibration Options | B-711 — single-point (pH 7.0) |
| Minimum Sample Volume | 0.05 mL (with optional sampling film B) |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP67 (dust-tight |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium coin cells |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | Approx. 50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH (after calibration with standard buffers) |
| Calibration Solutions | pH 4.01, 7.00, and 9.01 buffer solutions |
| Calibration Modes | B-711 — single-point calibration |
| Minimum Sample Volume | 0.05 mL (with optional sampling film B) or ≥0.1 mL |
| Temperature Compensation | Automatic (NTC thermistor) |
| IP Rating | IP67 (dust-tight |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium coin cells |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | Approx. 50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-22 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Flat-surface pH sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for general laboratory, field, and quality control use per ISO 3696 (Grade 3 water), ASTM D1293, and JIS K 0107 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pocket pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution & Accuracy | ±0.1 pH |
| Calibration | B-711 — One-Point (pH7) |
| Minimum Sample Volume | 0.05 mL (with optional sampling film) |
| Temperature Compensation | Automatic (5–40 °C) |
| IP Rating | IP67 (dust-tight |
| Power | Two CR2032 batteries |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUAtwin pH B-711 (single-point calibration) / B-712 (dual-point calibration) |
| Instrument Type | Pen-type pH meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution & Accuracy | ±0.1 pH |
| Minimum Sample Volume | 0.05 mL (with sampling film) or ≥0.1 mL |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 standard buffers |
| Temperature Compensation | Automatic (ATC), 5–40 °C operating range |
| Ingress Protection | IP67 (submersible to 1 m for 30 min) |
| Power | Two CR2032 lithium coin cells |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH (after calibration with standard buffers) |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 buffer solutions |
| Calibration Modes | B-711 — single-point calibration |
| Temperature Compensation | Automatic (ATC), 5–40 °C |
| IP Rating | IP67 (dust-tight and submersible to 1 m for 30 min) |
| Sample Volume | ≥0.05 mL (with optional sampling film B) or ≥0.1 mL (standard) |
| Power Supply | Two CR2032 lithium batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excluding protrusions) |
| Weight | Approx. 50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 4163-10T |
| Temperature Range | 0–100 °C |
| Compatibility | Designed for use with HORIBA pH/ORP meters (e.g., LAQUA series) and compatible third-party analyzers requiring Pt1000 or analog temperature input |
| Output Signal | Analog (2-wire RTD, Pt1000 class B per IEC 60751) |
| Enclosure Material | Chemically resistant PPS (polyphenylene sulfide) body with stainless steel tip |
| Cable Length | 1 m standard (custom lengths available) |
| IP Rating | IP67 |
| Calibration Traceability | NIST-traceable reference data provided upon request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ToupH™ Series (e.g., 9615-10D, 9625-10D, 0040-10D) |
| Temperature Range | 0–100 °C (glass) |
| pH Range | 0–14 (standard) |
| Construction | Composite glass or ISFET sensing element with integrated temperature sensor and double-junction reference system |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <791>, and GLP/GMP environments requiring traceable calibration and stable long-term drift performance |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (Dissolved Oxygen) |
| Measurement Range | 0.00–19.99 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.01 mg/L |
| Measurement Principle | Membrane-based Galvanic Cell |
| Temperature Compensation | 0–40 °C |
| Salinity Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Saturation DO Range | 0.0–200.0 % |
| Oxygen Concentration Range | 0.0–50.0 % |
| Display | Backlit Monochrome LCD |
| Data Storage | 1000 records with timestamp, ID, and temperature |
| Environmental Rating | IP67 |
| Operating Temperature | 0–45 °C |
| Power | 2× AAA alkaline or Ni-MH batteries (≈500 h battery life) |
| Dimensions | 67 × 28 × 170 mm (max thickness 80 mm) |
| Weight | 270 g (body only) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9625-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| ORP Range | ±1500 mV |
| Electrode Type | Combination pH/ORP/Temp (3-in-1), Gel-Filled, Plastic Body, Flat-Tipped ISFET-Glass Hybrid Design |
| Response Time (pH) | ≤15 s (t₉₀, ΔpH = 1.0) |
| Drift | <0.01 pH/h (25 °C, buffered solution) |
| Reference System | Cation-Selective Hollow-Fiber Junction |
| Glass Membrane | Rare-Earth-Doped High-Strength Bulb (JIS S 6001 Compliant, >10× strength) |
| Storage | Dry (no KCl soaking required) |
| Electrode Head Geometry | Flat, 100 µm clearance to protective sleeve |
| ESD Protection | Integrated semiconductor-grade anti-static circuitry |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH-22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter |
| Measurement Range | 2.0–12.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH (after calibration with standard buffers) |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 buffer solutions |
| Calibration Modes | B-711 — one-point calibration |
| Sample Volume | ≥0.05 mL (with optional sampling film B) or ≥0.1 mL (standard mode) |
| Temperature Compensation | Automatic (NTC thermistor) |
| Auto-Hold Function | Yes |
| IP Rating | IP67 (dust-tight |
| Operating Environment | 5–40 °C, <85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | Approx. 50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Accuracy | ±0.1 pH |
| Resolution | 0.1 pH |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 standard buffers |
| Calibration Modes | B-711 — single-point |
| Temperature Compensation | Automatic (ATC) |
| IP Rating | IP67 (dust-tight |
| Sample Volume | ≥0.05 mL (with optional sampling film) |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power | Two CR2032 lithium batteries |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, excl. batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | B-711 / B-712 |
| Instrument Type | Pen-style pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 2.0–12.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH (after calibration, repeatability in standard buffer solutions) |
| Calibration Solutions | pH 4.01, 7.00, and 9.21 buffers |
| Calibration Modes | B-711 — single-point |
| Sample Volume | ≥0.05 mL (with optional sampling film B) |
| Temperature Compensation | Automatic (NTC thermistor) |
| Auto-Hold Function | Yes |
| IP Rating | IP67 (dust-tight |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Power Supply | Two CR2032 lithium coin cells |
| Dimensions (L×W×H) | 164 × 29 × 20 mm (excluding protrusions) |
| Weight | Approx. 50 g (instrument only, excluding batteries) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | D-71 |
| Instrument Type | Portable pH Meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH ±1 digit |
| Repeatability | ±0.01 pH ±1 digit |
| Calibration Solutions | pH 4.01, 7.00, 9.18 (USA/NIST traceable) |
| Temperature Compensation | Automatic & Manual (0.0–100.0 °C, resolution 0.1 °C, accuracy ±0.1 °C ±1 digit) |
| Display | Backlit monochrome LCD |
| Data Storage | 1000 measurement records with timestamp, ID, and temperature |
| Environmental Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Power Supply | 2 × AAA alkaline or Ni-MH batteries (battery life ≈ 1000 h) |
| Operating Conditions | 0–45 °C, ≤80% RH (non-condensing) |
| Dimensions | 67 × 28 × 170 mm (W × D × H, max thickness 80 mm) |
| Weight | 270 g (without batteries) |
| Compliance | GLP/GMP-ready data logging, audit trail support via PC software, conforms to ISO/IEC 17025 calibration traceability requirements for field-deployable electrochemical instrumentation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| Compliance | ISO 3696 (Grade 2 water), ASTM D1293, USP <791>, JIS Z 8802 |
| Electrode Type | Integrated Glass pH Sensor + Ag/AgCl Reference + Pt ORP Element + NTC Thermistor |
| Body Material | Chemically Resistant PPS Plastic |
| Tip Geometry | Flat-Surface Ceramic Junction with Sub-100 µm Guard Gap |
| Response Time (t₉₀) | ≤15 s (pH 4 → 7 → 10 buffer transition, 25 °C) |
| Drift | <0.01 pH/h (24 h, stable electrolyte fill) |
| Mechanical Strength | >10× JIS R 3201 (Glass Electrode Impact Resistance Standard) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | U-50 Portable |
| Instrument Type | Multiparameter |
| Parameter Count | 11 |
| pH Range | 0–14 |
| pH Resolution & Accuracy | 0.01 pH |
| ORP Range | −2000 to +2000 mV |
| DO Range | 0–50.0 mg/L |
| DO Resolution | 0.01 mg/L |
| Conductivity Range | 0–10 S/m |
| Turbidity Methods | LED forward scatter (U-53), tungsten lamp 90° scatter (U-53G), LED 90° scatter (U-54) |
| Turbidity Resolution | 0.01 NTU (0–10 NTU range) |
| Depth Measurement | up to 30 m (pressure-based, optional on U-52G/U-53G/U-54G) |
| Temperature Range | −10 to 55 °C |
| IP Rating | IP67 (host), IP68 (probe) |
| Battery Life | up to 70 h (alkaline AA ×4, backlight off) |
| Data Storage | 10,000 sets |
| Communication | USB |
| Calibration | 2-point pH (pH 4.01/7.00/9.18 buffers), multi-point turbidity/conductivity |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop |
| Parameter Channels | Dual (pH/ORP + Ion/Temp) |
| pH Range | 0.000–14.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.01 |
| pH Repeatability | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Repeatability | ±0.1 mV |
| Ion Concentration Range | 0.00 µg/L – 999 g/L (mol/L basis) |
| Ion Resolution | 3 significant digits |
| Ion Repeatability | ±0.5% F.S. |
| Temperature Range | −30.0 to 130.0 °C |
| Temp Resolution | 0.1 °C |
| Temp Repeatability | ±0.1 °C |
| Calibration Buffers | pH 4.01, 7.00, 9.21 |
| Data Storage Capacity | 2000 measurements |
| Language Support | English, Japanese, Korean, Chinese |
| Power Supply | AC Adapter 100–240 V, 50/60 Hz |
| Power Consumption | ~9.8 VA |
| Net Weight | 700 g |
| Compliance | JIS Z 8802, USP <791>, EP 2.2.3, JP XVI, GLP/GMP-ready data logging and audit trail support |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 0040-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Solid-State ISFET (Ion-Sensitive Field-Effect Transistor) |
| Sensing Surface | Flat-tip, <100 µm gap between sensor surface and protective sleeve |
| Compliance | Designed for GLP/GMP-relevant environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | PH22 |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Design | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and GLP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUAtwin B-711 (single-point calibration) / B-712 (dual-point calibration) |
| Instrument Type | Pocket-style pH meter |
| Parameter Type | Single-parameter (pH) |
| Measurement Range | pH 2.0–12.0 |
| Resolution & Accuracy | ±0.1 pH |
| Minimum Sample Volume | 0.05 mL (with sampling film) or ≥0.1 mL |
| Calibration Solutions | pH 4.01, 7.00, and 9.18 standard buffers |
| Temperature Compensation | Automatic (ATC), 5–40 °C operating range |
| Protection Rating | IP67 (submersible to 1 m for 30 min) |
| Power | Two CR2032 lithium coin cells |
| Dimensions | 164 × 29 × 20 mm (excl. protrusions) |
| Weight | ~50 g (instrument only, batteries excluded) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and educational use in accordance with ISO 7888 and ASTM D1293 guidelines |