| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | HPLC 1500 |
| Flow Rate Range | 0.001–5 mL/min and 0.01–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | 190–380 nm (D₂ lamp), 366–800 nm (W lamp) |
| UV-Vis Detector Sensitivity | 0.0005–2.0 AUFS |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SSI Prep 2100 |
| Pump Flow Rate | Up to 100 mL/min per pump |
| Gradient Modes | Step, Linear, and Curvilinear (Programmable) |
| Detector Options | UV-Vis (UV201, wavelength-programmable), RID, ELSD (with flow splitter) |
| Fraction Collection | FC Jr. Fraction Collector (time-, volume-, drop-, or peak-triggered) |
| Construction | Stainless steel flow path |
| Compliance | FDA 21 CFR Part 11, GLP-ready audit trail |
| Brand | GRACE |
|---|---|
| Origin | Germany |
| Model | RI 2000 |
| Detection Principle | Differential Refractometry |
| Refractive Index Range | 1.00–1.75 |
| Flow Rate Range | 0.2–3.0 mL/min |
| Linear Range | 80 × 10⁻⁵ RIU |
| Noise Level | 5 × 10⁻¹⁰ RIU |
| Auto-Zero Range | 40 × 10⁻⁵ RIU |
| Auto-Zero Resolution | 5 × 10⁻¹⁰ RIU |
| Integrator Output | ±1 V |
| Recorder Output | ±10 V |
| Analog Input Range | −5 to +5 V DC |
| Temperature Setpoints | Ambient, 35 °C, or 55 °C (microprocessor-controlled) |
| Flow Cell Volume | 9 µL |
| Maximum Flow Cell Pressure | 6 kg/cm² |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SSI/LabAlliance 340 |
| Flow Rate | Up to 40 mL/min |
| Detector | UV201 Variable Wavelength Detector with Adjustable Flow Cell (0–3 mm pathlength) |
| Pump Type | Dual-piston syringe pump with integrated low-pulse dampener |
| Sample Introduction | Rheodyne 3725(i) manual injection valve |
| Construction | Stainless steel fluidic path |
| Compliance | Designed for GLP-compliant preparative workflows |
| Software Control | Fully automated system control via dedicated chromatography software |
| Brand | GRACE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MODcol® |
| Instrument Type | Static Axial Compression System |
| Design Principle | Spring-Actuated Constant-Pressure Bed Consolidation |
| Column Independence | Self-Contained (No External Hydraulic Source Required) |
| Fill Material Compatibility | ≥5 µm Particles (Silica, Polymer, Soft Gel) |
| Optional Configurations | Water-Jacketed Temperature Control, Prepacked (VYDAC®), or User-Packable with MODcol MULTIPACER® |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 305 |
| Optical Design | Dual monochromator with concave holographic diffraction gratings |
| Excitation/Emission Wavelength Range | 200–600 nm (Ex & Em) |
| Wavelength Accuracy | ±2 nm @ 248 nm Ex / 398 nm Em |
| Wavelength Precision | <0.5 nm |
| Spectral Bandwidth Options | 8, 20, or 30 nm |
| Light Source | Pulsed xenon lamp (20 Hz or 100 Hz selectable) |
| Flow Cell | Biocompatible quartz/Teflon/Kalrez/PEEK, 8 µL detection volume, max pressure 200 psi (14 bar) |
| Sensitivity | 2 µg/L anthracene in methanol, S/N > 1500 @ 284 nm Ex / 398 nm Em |
| Scan Speed | Up to 100 steps/sec |
| step resolution | 2, 4, 8, 16, or 32 nm |
| Stored Spectra Capacity | Up to 60 emission spectra |
| Dynamic Range | 0.01–500 FUFS (Fluorescence Units Full Scale) with 15 programmable gain levels |
| Analog Output | 20-bit D/A converter, full-scale range adjustable |
| Detection Modes | Fluorescence, phosphorescence, chemiluminescence |
| Method Storage | 4 user-defined method files, each supporting up to 10 time-programmed wavelength transitions, with inter-file linking capability |
| Operating Environment | 10–40 °C, 5–95% RH (non-condensing) |
| Dimensions & Weight | 7" H × 12" W × 16" D, 24 lbs (11 kg) |
| Power Supply | 220 VAC, 50/60 Hz, max 2 A |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CP |
| Pricing | Available Upon Request |
| Pump Flow Range | 1–24 mL/min |
| Maximum Pressure | 10,000 or 18,000 psi |
| Pump Control Interface | RS-232 with pressure/flow sensors |
| Construction | Stainless Steel (SS) |
| Voltage | 110/220 V AC |
| Column Hardware Included | Two 4.6 × 150 mm stainless steel column assemblies (including endfittings, frits, and 2 µm stainless steel frits) |
| Slurry Vessel | 20 mL agitated slurry reservoir |
| Packing Accessories | Compression ferrules, metal bands, reducing adapters, O-rings, 1/16″ OD × 0.03″ ID stainless steel tubing |
| Stationary Phase | 10 g C18 silica-based packing material |
| Software | Quick-Set pump control software |
| Compliance | Designed for GLP-compliant column manufacturing environments |
| Key | Brand: GRACE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Peak Biotech A/S |
| Pricing | Available Upon Request |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Laballiance PCDS |
| Price | Upon Request |
| Pump Flow Rate | 0.01–2.5 mL/min |
| Maximum Pressure | 2500 psi |
| Flow Precision | ±0.5% RSD |
| Flow Accuracy | ±2% |
| Flow Path Material | Full PEEK |
| Temperature Control Range | Ambient +10 °C to 150 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ±1 °C |
| Safety Cutoff Temperature | 160 °C |
| Reactor Volume Accuracy | ±5% |
| Warm-up Time to 150 °C | ≤30 min |
| Communication Interface | RS232 |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 6000 |
| Wavelength Range | 190–800 nm |
| Optical Path Length | 5 cm |
| Flow Cell Volume | 12 µL (10 mm path) |
| Noise | ±3 × 10⁻⁶ AU/cm |
| Drift | 1 × 10⁻³ AU/hr |
| Linearity | >2.0 AU |
| Scan Rate | ≤20 Hz |
| Spectral Resolution | 1.2 nm |
| Wavelength Accuracy | ±1 nm |
| Light Source | Deuterium + Tungsten-Halogen Lamps |
| A/D Converter | 20-bit |
| Data Acquisition Rate | Configurable up to 20 Hz |
| Beam Delivery | Stacked Optical Fiber Optics |
| Compliance | ASTM E275, USP <857>, ISO/IEC 17025-aligned verification protocols |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 25 and 50 |
| Instrument Type | Static Axial Compression System |
| Column ID Compatibility | 25 mm, 50 mm, 101 mm |
| Packing Mechanism | Spring-actuated static axial compression |
| Operational Pressure Range | Low-pressure (≤ 20 bar typical) |
| Packing Time | < 5 minutes per column |
| Fill Material Compatibility | Silica-based, polymer-based, and fragile non-silica stationary phases (e.g., agarose, cellulose, hybrid organic-inorganic) |
| Structural Frame | Precision-cast aluminum alloy |
| Brand | LabAlliance |
|---|---|
| Origin | USA |
| Model | SCS-200 |
| Instrument Type | Ambient-Temperature GPC Cleanup System |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pressure | 2500 psi (pump), 1500 psi (column) |
| Flow Path Materials | 316 Stainless Steel, Ceramic, Inert Polymer |
| Injector | Adjustable 2 mL Manual Injector with Valve Position Sensing & Loop Interface |
| Column Dimensions | 250 × 16 mm (customizable) |
| Packing Material | PS-DVB Copolymer |
| Pore Size | 50 nm |
| Particle Size | 10 µm |
| Max Operating Temperature | 60 °C |
| Sample Load Capacity | 300 mg |
| Fraction Collector | Three-Position Electronic Solenoid Valve |
| Control Interface | Front-Panel SCU + RS-232 Serial Communication |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | Flash 150 |
| Maximum Flow Rate | 150 mL/min |
| Maximum Pressure | 200 psi |
| Detector | VUV14 Fixed-Wavelength UV Detector (254 nm) |
| Method Storage Capacity | 10 Predefined Gradient Methods + User-Programmable Gradients |
| Fluidic Path Material | 316 Stainless Steel |
| Fraction Collection | Integrated, Trigger-Based |
| Control Unit | Dedicated Embedded System with Touchscreen Interface |
| Compliance | Designed for GLP/GMP-adjacent laboratory environments |
| Software | Standalone instrument control with real-time data logging and method export capability |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | FC Jr |
| Dimensions | 28 cm (W) × 27 cm (H) × 31 cm (D) |
| Weight | 4.7 kg |
| Temperature Range | 0–40 °C |
| Step Timer Range | 1 s – 99 h 59 min 59 s |
| Drop Counter Range | 1–999,999 |
| Volume Counter Range | 1–999,999 units |
| Peak Detection Modes | Slope-based and/or plateau-based triggering, combinable with time windows |
| Time Windows per Program | Up to 10 |
| Tube Exchange Time (center-to-center) | 200–450 µs (dependent on tube diameter) |
| Program Storage | 9 full collection protocols with internal battery-backed memory |
| Interface | RS232 for LC system integration |
| Collection Modes | Time-based, drop-count-based, volume-based, and peak-triggered (UV/absorbance signal) |
| Collection Patterns | Linear (left-to-right) or spiral |
| Tube Holder Options | Compatible with 12–25 mm diameter tubes |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | 201/525 |
| Wavelength Range | 190–380 nm (Model 201), 190–365 nm (Model 525) + Tungsten Lamp 366–800 nm |
| Dual-Wavelength Capability | 190–450 nm or 366–800 nm |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Noise | < ±1.0 × 10⁻⁵ AU @ 254 nm (single wavelength) |
| Absorbance Range | 0.0005–3.0 AUFS |
| Absorbance Linearity | >99% to 2.0 AU @ 254 nm |
| Optical Design | Concave holographic grating monochromator, dual-beam with fiber-optic beam splitter |
| Analog Output | Dual-channel, full-scale selectable |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions | 30.5 cm W × 40.6 cm D × 17.8 cm H (12″ × 16″ × 7″) |
| Weight | 14 kg (31 lb) |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Model | R1 |
| Dimensions | 35.6 × 31.1 × 33.0 cm (H×W×D) |
| Weight | 7.7 kg (without rack) |
| Max Flow Rate | 100 mL/min |
| Delay Volume | Micro-liter level (valve positioned at outlet of flow path) |
| Communication | Ethernet (TCP/IP) & RS-232 |
| Power | 100/117 VAC or 234 VAC, 50/60 Hz |
| Rack Options | 144×12 mm tubes |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPLC 1500 Series |
| Price | Upon Request |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 6,000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.075% RSD |
| Gradient Precision | ±1% |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Range | D₂ Lamp (190–380 nm), W Lamp (366–800 nm) |