Beishide Instrument
Filter
Showing 31–60 of 64 results
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-LN |
| Pricing | Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BSD-LNL |
| Pricing | Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BSD-LNT |
| Pricing | Available Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-MAB- |
| Pricing | Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BSD-MAB |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Gas Mixture Compatibility | Binary and multicomponent gas–gas, gas–vapor, vapor–vapor systems |
| Mass Flow Controllers (MFCs) | 4–8 independently programmable channels |
| Breakthrough Columns | Standard stainless-steel columns (2 mL and 8 mL volumes) |
| Adsorption Pressure Range | Ambient to 10 MPa (optional high-pressure modules: up to 1 MPa or 3 MPa) |
| Adsorption Temperature Control | Circulating water bath (−20 °C to 80 °C, ±0.1 °C stability) |
| High-Temperature Furnace | Ambient to 600 °C (customizable beyond) |
| Detection Systems | Integrated thermal conductivity detector (TCD) |
| Detection Limits | TVOC: 5 × 10⁻¹² g/mL |
| SO₂ | 14 × 10⁻¹² g/mL |
| NH₃ | 16 × 10⁻¹² g/mL |
| Vapor Generation System | P/P₀ control range 0.1%–99.99%, accuracy ±1% |
| Vacuum Activation | <0.1 Pa base pressure |
| Corrosive Gas Compatibility | SO₂, NH₃, organic vapors (compatible with fluorocarbon-sealed components) |
| Regulatory Compliance Support | ASTM D5228, ISO 12213-2, USP <621>, GLP-compliant data audit trail (via optional software module), FDA 21 CFR Part 11-ready configuration available |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MAB1 |
| Gas Range | Binary & Ternary Mixtures Including Gas/Gas, Gas/Vapor, Vapor/Vapor |
| MFC Channels | 4–8 |
| Breakthrough Columns | Standard 2 mL & 8 mL Stainless Steel or Quartz Columns (Custom Volumes Available) |
| Adsorption Pressure | Ambient to 10 MPa |
| Adsorption Temperature | Circulating Water Bath (−20 °C to 80 °C), High-Temperature Furnace (RT to 600 °C |
| Detector Options | Integrated TCD, Optional Online GC or Mass Spectrometer (MS) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BSD-MABX |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Gas Mixture Compatibility | Binary and multicomponent gas–gas, gas–vapor, vapor–vapor systems |
| Mass Flow Controllers (MFCs) | 4–8 configurable channels |
| Breakthrough Columns | Standard 2 mL and 8 mL stainless-steel columns |
| Adsorption Pressure Range | Ambient to 10 MPa (optional high-pressure modules: 1, 3, or 10 MPa) |
| Adsorption Temperature Range | Circulating water bath: −20 °C to 80 °C |
| programmable high-temperature furnace | ambient to 600 °C (custom up to 800 °C) |
| Detection Systems | Integrated TCD |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | BSD-PAGP |
| Pricing Range | USD 70,000 – 140,000 (FOB) |
| Measurement Method | Static Volumetric Method |
| Temperature Range | −10 °C to +80 °C (±0.1 °C stability) |
| Pressure Range | 0–69 MPa |
| Ultimate Vacuum | 1×10⁻² to 1×10⁻⁶ Pa |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BSD-PB |
| Price Range | USD 14,000 – 70,000 |
| Pore Size Range (Gas-Liquid Method) | 0.02–500 µm |
| Pore Size Range (Liquid-Liquid Method) | 5–500 nm |
| Vacuum-Assisted Wetting System | Integrated, Automatic |
| Pressure Sensors | Dual, 0–1 bar & 0–40 bar, ±0.05 mbar accuracy |
| Flow Sensors | Dual, 0–1 L/min & 0–200 L/min, ±0.1 mL/min accuracy |
| Balance (BSD-PBL variant) | Sartorius, 0–2100 g, ±0.01 g |
| Compliance Standards | GB/T 32361-2015, ASTM F316-03, ASTM D6767-02, ISO 2942, DIN ISO 4003, BS 7591-4, HY/T 051, HY/T 064, GB/T 14041.1, GB/T 24219, GB/T 2679.14 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PBx |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Operating Principle | Static Gas Pressure Method (Bubble Point & Gas Flow) |
| Number of Analysis Stations | 1 |
| Pore Size Range | 0.02 – 500 µm |
| Pressure Range | 0–1 bar & 0–40 bar (dual-range, auto-switching) |
| Test Theory | Gas Bubble Point Method |
| Repeatability | ±0.01 µm (on certified reference membranes) |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BSD-PB |
| Price Range | USD 14,000 – 42,000 |
| Pore Size Range (Gas-Liquid) | 0.02–500 µm |
| Pore Size Range (Liquid-Liquid) | 5–500 nm |
| Vacuum-Assisted Wetting | Integrated automatic system |
| Dual Pressure Sensors | 0–1 bar & 0–40 bar, ±0.05 mbar accuracy |
| Dual Flow Sensors | 0–1 L/min & 0–200 L/min, ±0.1 mL/min accuracy |
| Compliance | GB/T 32361-2015, ASTM F316-03, ASTM D6767-02, ISO 2942, DIN ISO 4003, BS 7591-4, HY/T 051, HY/T 064 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-PBB |
| Pricing | Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-PBL |
| Price Range | USD 14,000 – 42,500 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-PH |
| Testing Method | Static Volumetric Method |
| Temperature Range | -196 °C to 300 °C (extendable to 1100 °C with optional furnace) |
| Pressure Range | High vacuum to 690 bar (69 MPa) |
| Ultimate Vacuum | 1 × 10⁻⁷ mbar |
| Repeatability | ±2% |
| Pressure Sensor Accuracy | ±0.01% FS |
| Air-Bath Temperature Control | 40.0 °C ±0.1 °C |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-PHC |
| Pricing Range | USD 70,000 – 140,000 (FOB) |
| Measurement Method | Static Volumetric Method |
| Temperature Range | Ambient to 80 °C (standard) |
| Pressure Range | Adsorption: 0–20 MPa (standard), 0–50 MPa / 0–69 MPa (optional) |
| Confining (Cladding) Pressure | 0–50 MPa / 0–70 MPa (optional) |
| Ultimate Vacuum | <1×10⁻⁶ mbar (equivalent to full-scale 690 bar operation) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BSD-PHD |
| Measurement Method | Volumetric (Static Capacity) Method |
| Temperature Range | –196 °C to 1100 °C |
| Pressure Range | 0–20 MPa |
| Ultimate Vacuum / Maximum Pressure | Up to 690 bar (69 MPa) |
| Repeatability Error | < ±2% |
| Pressure Sensor Accuracy | ±0.01% FS, Long-term Stability: ±0.025% FS |
| Air-Bath Temperature Control | 40.0 °C ±0.1 °C |
| Safety | Integrated combustible gas alarm, high-pressure integrity tested, optional alarm interlock system |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BSD-PHE |
| Testing Method | Volumetric (Static Capacity) Method |
| Temperature Range | –196 °C to 300 °C (extendable to 1100 °C with optional high-temp furnace) |
| Pressure Range | High Vacuum to 200 bar (20 MPa) |
| Ultimate Vacuum | 1×10⁻² Pa |
| Key Compliance | ASTM D3663, ISO 15901-2, USP <642>, IUPAC Recommendations for Physisorption |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-PHU |
| Testing Method | Static Volumetric Method |
| Temperature Range | –196 °C to 80 °C (standard) |
| Pressure Range | High vacuum to 700 bar (70 MPa) |
| Ultimate Vacuum | 1×10⁻² to 1×10⁻⁶ Pa |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | BSD-PHUO |
| Testing Method | Static Volumetric Method |
| Temperature Range | -196 °C to 300 °C (extendable to 900 °C with optional high-temp furnace) |
| Pressure Range | High vacuum up to 700 bar (70 MPa) |
| Ultimate Vacuum | 1×10⁻² to 1×10⁻⁶ Pa |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BSD-PM |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method (Gas Adsorption) |
| Number of Analysis Stations | 1–12 |
| Specific Surface Area Range | ≥0.0005 m²/g |
| Pore Diameter Range | 0.35–500 nm |
| Pressure Range | 0–1000 Torr (with optional 0–0.1 Torr high-resolution sensor) |
| Repeatability | ≤±0.01% for surface area, ≤±0.02 nm for most probable pore diameter |
| Vacuum Level | PS Series — 4×10⁻² Pa |
| Degassing Stations | 2 independent thermal treatment stations (RT–400 °C, ±0.1 °C control accuracy) |
| Independent P₀ Station | Patented helical saturation vapor pressure station |
| Compliance Standards | GB/T 19587–2017, ISO 9277:2010, ISO 15901-1/2/3:2005–2007, GB/T 39713–2020, GB/T 21650.1–3, GB/T 13390–2008, GB/T 10722–2014, GB/T 7702.20–2008, GB/T 6609.35–2009 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BSD-PMV |
| Instrument Type | Static Vapor Adsorption Analyzer |
| Mass Resolution | 0.01 µg |
| Mass Range | 0.001 g |
| Temperature Range | 0–105 °C |
| Relative Humidity Range | 0.01–98 % P/P₀ |
| Humidity Accuracy | Better than 0.001 torr (7×10⁻⁶ mbar) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BSD-TD |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid (powder, granule, bulk, foam, ceramic, metal, rock core), slurry, non-volatile liquid |
| Density Range | 0.01–2000 g/cm³ |
| Density Accuracy | ±0.03% |
| Repeatability | ±0.015% |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 0.01–2000 mL |
| Temperature Control Range | 0–40 °C |
| Temperature Stability | < ±0.1 °C |
| Analysis Stations | 1 or 2 |
| Measurement Principle | Gas Expansion Displacement (based on ideal gas law PV = nRT) using inert gas (He or N₂) |
| Compliant Standards | GB/T 40401-2021, GB/T 10799-2008, GB/T 5071-2013, ASTM D2856, ASTM D6226, MT/T 713-1997 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | BSD-TD-K |
| Price Range | USD 14,000 – 21,000 |
| Application Field | General-purpose density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Types | Powders, solid blocks, slurries, liquids |
| Density Measurement Range | 0.001–10 g/cm³ (typical for solids & liquids) |
| Density Accuracy | ±0.03% (relative to certified Al reference standard) |
| Temperature Control Range | −10 °C to +50 °C, stability ±0.1 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 3 mL |
| Maximum Sample Volume | 2000 mL |
| Test Cycle Time | 3–6 min (excluding thermal equilibration) |
| Pressure Mode | Positive-pressure gas expansion (He or N₂, optional vacuum pump for degassing) |
| Valve System | Pneumatically actuated valves (zero self-heating) |
| Calibration Standard | Certified aluminum reference cylinder (NIM-traceable) |
| Compliance | GB/T 23561.2–2009, GB/T 10799–2008 (Annex B), ISO 12154:2014 (gas pycnometry), ASTM D5550–22 (standard test method for true density of calcined petroleum coke) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-TDK |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Measurement Principle | Gas Displacement (Helium Pycnometry) |
| Density Range | 0.01–2000 g/mL |
| Density Accuracy | ±0.06% |
| Repeatability | ±0.04% |
| Resolution | 0.0001 g/mL |
| Temperature Control Range | 0–40 °C |
| Sample Volume Capacity | 0.01–500 mL |
| Analysis Time | 3–5 min per run (≤60 s for 10 mL cell) |
| Standard Sample Cells | 10 mL, 50 mL, 150 mL (custom larger cells available) |
| Reference Chamber | Dual internal reference volumes optimized per cell size |
| Pressure Range | 0–1 bar (user-adjustable) |
| Operating Gas | High-purity helium (≥99.999%), nitrogen optional |
| Gas Handling | Automated multi-cycle purge & leak-check sequence |
| Data Compliance | Supports audit-trail export, PDF report generation (single/batch), GLP/GMP-ready metadata logging |
| Hardware Interface | Embedded controller with graphical UI, voice-guided operation, remote Internet control capability |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Static Vapor Sorption Analyzer |
| Model | BSD-VVS |
| Weighing Resolution | 1 µg / 2000 mg |
| Weighing Range | 10–1000 mg (0.1 µg resolution for 10–100 mg range) |
| Temperature Range | Ambient to 400 °C |
| Humidity Control Range | 0.01–99% RH |
| Humidity Accuracy | ±0.01% RH |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BSD-VVS&DVS |
| Instrument Type | Dynamic Vapor Sorption Analyzer |
| Mass Resolution | 1 µg |
| Mass Range | 10–2000 mg |
| Temperature Range | Ambient to 50 °C |
| Humidity Control Range | 0.1–98% P/P₀ (with optional extension to lower P/P₀) |
| Temperature Stability | ±0.1 °C |
| Humidity Accuracy | ±0.1 °C (accuracy), <0.1 °C (stability) |
| Analytical Stations | 4 or 8 simultaneous positions |
| Vacuum System | Dual-pump configuration (mechanical pump + vapor pump) |
| Pressure Sensing | Dual capacitive manometers (segmented range) |
| Vapor Generation | Static evaporation + carrier-gas mixing methods |
| Sample Heating | Ambient to 400 °C (vacuum degassing), ambient to 300 °C (purge mode), programmable 32-step TPD/TPO/TPR |
| Fluid Handling | 120 mL reagent reservoir with patented condensate recovery |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | BSD-VVS&DVS |
| Weighing Resolution | 1 µg / 2000 mg (0.1 µg / 100 mg optional) |
| Weighing Range | 1 µg to 2000 mg (customizable up to 5000 mg) |
| Temperature Range | −180 °C to 50 °C (accuracy ±0.1 °C, stability <0.1 °C) |
| Relative Humidity Range | 0.01–98% P/P₀ |
| Humidity Accuracy | <0.001 torr (7×10⁻⁶ mbar) |
| Sorption Modes | Static (vacuum) & Dynamic (flow-through) gravimetric |
| Analysis Stations | 4 or 8 independent, fully synchronized positions |
| Gas/Vapor Compatibility | H₂O, organic vapors, CO₂, alkanes/alkenes |
| Vacuum System | Dual-pump configuration (mechanical + vapor pump) |
| Pressure Sensing | Dual capacitive diaphragm gauges (segmented range) |
| Flow Control | High-precision mass flow controllers (MFCs) |
| Thermal Management | Full-path thermostating (vapor lines, sample chamber, balance enclosure) |
| Software Compliance | Audit trail, user access control, electronic signatures per FDA 21 CFR Part 11 |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static & Dynamic Vapor Sorption Analyzer |
| Mass Range | 1 µg / 5000 mg |
| Mass Resolution | 1 µg / 5000 mg (optional 0.1 µg / 500 mg) |
| Temperature Control Range | –5 °C to 150 °C (±0.1 °C accuracy, liquid bath) |
| Relative Humidity (RH) Range | 0.1–98% P/P₀ |
| RH Accuracy | ±0.1 °C over full gas-path isothermal zone (room temperature to 60 °C) |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | BSD-VVS&DVS8 |
| Instrument Type | Static & Dynamic Vapor Adsorption Analyzer |
| Analytical Stations | 4 or 8 (configurable) |
| Microbalance Resolution/Range | 1 µg / 5000 mg (optional 0.1 µg / 500 mg) |
| Temperature Control | Degassing Furnace: RT–400 °C (±0.1 °C) |
| Thermostatic Bath | −5–150 °C (±0.1 °C) |
| Vapor Line Heating | RT–60 °C (±0.1 °C) |
| Vapor Pressure Control Range | 0.1–98% P/P₀ (2–98% P/P₀ standard |
| Vapor Generation Methods | Static Evaporation & Carrier-Gas Mixing Flow Method |
| Compatible Vapors | H₂O, organic solvents (e.g., ethanol, toluene), CO₂, alkanes/alkenes |
| Vacuum System | Dual-pump architecture — high-vacuum mechanical pump + dedicated vapor pump |
| Pressure Sensing | Dual capacitive diaphragm gauges (segmented range) |
| Gas Control | Imported mass flow controller (MFC) for precise vapor/gas mixing |
| Software Compliance | Audit trail, user access control, electronic signature support per FDA 21 CFR Part 11 requirements |
| Standards Support | ASTM D3663, ISO 15901-2, ISO 9277, USP <1251>, IUPAC recommendations for physisorption analysis |
| Key | Brand: Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | BSD-VVS+DVS |
| Weighing Resolution | 1 µg / 2000 mg (0.1 µg / 200 mg optional) |
| Weighing Range | 10–2000 mg (customizable up to 5000 mg |
| 0.1 µg sensitivity | 10–100 mg optional) |
| Temperature Control Range | −180 °C to 50 °C (accuracy ±0.1 °C, stability <0.1 °C) |
| Vapor Pressure Control Range | 0.1–98% P/P₀ (extendable to lower P/P₀ with optional saturator) |
| Dual Vacuum System | Rotary vane pump + vapor-tolerant turbomolecular pump (base pressure <1×10⁻⁶ torr) |
| Analytical Stations | 4 or 8 independent, fully synchronized gravimetric channels |
| Vapor Generation | Static saturation + carrier-gas dilution (dual-mode) |
| Compliance | ASTM D3663, ISO 15901-2, USP <1217>, IUPAC 2015 recommendations for physisorption |