BUCHI
Filter
Showing 31–60 of 61 results
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Product Category | Imported Instrument |
| Compliance Standards | AOAC, EPA, ISO, DIN |
| Automation Options | Manual to Fully Automated |
| Safety Features | Integrated Steam Trap, Overpressure Protection, Acid Fume Containment |
| Service Support | Global Technical Assistance, Method Validation Guidance, GLP-Compliant Documentation |
| Brand | BUCHI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | L-250 |
| Application Scope | Laboratory Use |
| Condenser Temperature | –85 °C |
| Condensation Capacity | 4 kg/24 h (water), 5 kg total |
| Refrigerant | Natural refrigerant with GWP = 4 |
| Noise Level | Reduced |
| Heat Emission | Low |
| Control System | Infinite-Control™ touchscreen interface, PC software, and mobile app support |
| Compliance | Designed for GLP-compliant workflows |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Lyovapor L-200 |
| Pricing | Available Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Lyovapor L-300 |
| Pricing | Available upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | M-560 / M-565 |
| Temperature Range | Ambient to 400 °C |
| Heating Rates | 0.1, 0.2, 0.5, 1, 1.5, 2, 2.5, 3, 5, 10, 20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Dimensions | 80 mm length × 1 mm diameter |
| Sample Capacity | 3 samples for melting point determination (M-565: automated & visual) |
| Temperature Resolution | 0.1 °C |
| Display | 3.5″ color TFT (320 × 240) |
| Heating Time | ~4 min (50 → 350 °C) |
| Cooling Time | ~10 min (350 → 50 °C) |
| Power Consumption | 150 W |
| Certifications | CE, UL |
| Dimensions (W × D × H) | 190 × 200 × 370 mm |
| Weight | 4.5 kg |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Laboratory-scale spray dryer |
| Model | S-300 |
| Sample Compatibility | Aqueous, organic, and mixed-phase solutions |
| Maximum Feed Rate | 1.5 L/h (water) |
| Inlet Temperature Range | Ambient to 220 °C (standard), up to 250 °C (optional) |
| Outlet Temperature Control | Precise PID-regulated |
| Particle Size Distribution | 1–25 µm (dependent on nozzle type and process parameters) |
| Nozzle Options | Dual-fluid (2–25 µm), triple-fluid (for encapsulation), ultrasonic (10–60 µm) |
| Integrated Safety | O₂ monitoring, inert gas recirculation compatibility (with S-395), pressure-controlled closed-loop operation |
| Data Logging & Reporting | Full process parameter recording, one-click PDF/.csv report generation |
| Compliance Support | Designed for GLP/GMP-aligned workflows |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | Multivapor P-12 |
| Capacity | 12 × 30 mL |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 20–485 rpm |
| Temperature Range | 20–95 °C |
| Temperature Control Accuracy | ±3 °C (max) |
| Condenser Cooling Surface Area | 1700 cm² |
| Power Consumption | 800 W |
| Electrical Supply | 100–240 V, 50–60 Hz |
| Sample Vessel ID | 16–30 mm |
| Sample Vessel Length | 110–170 mm |
| Wetted Materials | PETP (or PEEK), PTFE, PFA, Borosilicate Glass |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | P-6 |
| Capacity | 6 × 150 mL |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 0–370 rpm |
| Temperature Range | 20–95 °C |
| Temperature Control Accuracy | ±3 °C (max) |
| Condenser Cooling Surface Area | 1700 cm² |
| Power Consumption | 800 W |
| Electrical Supply | 100–240 V, 50–60 Hz |
| Wetted Materials | PETP (or PEEK), PTFE, PFA, Borosilicate Glass |
| Brand | BUCHI |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | X-One (One-Six) |
| Instrument Type | In-line |
| Operating Principle | Real-time in-process spectroscopy with fiber-optic coupling |
| Wavelength Range | 900–1700 nm (standard advanced configuration) |
| optional dual-range | 350–920 nm (VIS) and 950–1750 nm (NIR) |
| Scan Rate | 100 spectra per second |
| Spectral Sampling Interval | 3.2 nm |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | SX-Plus |
| Detector | Diode Array |
| Optical Spot Diameter | 30–40 mm |
| Imaging System | Integrated HD CCD camera, 80 µm spatial resolution in visible range |
| Light Source | Dual tungsten-halogen lamps, MTBF 18,000 h (2 × 9,000 h) |
| Environmental Rating | IP65/IP67 |
| Explosion-Proof Option | ATEX/IECEx certified (Ex II 1/2D ta tb IIIC T80°C |
| Dimensions (W×D×H) | 220 × 220 × 135 mm |
| Weight | 6–7 kg |
| Operating Temperature | −10°C to +70°C |
| Ambient Temperature Range | −10°C to +40°C |
| Relative Humidity | <90% RH, non-condensing |
| Vibration Resistance | 0.2 g (0.1–150 Hz) |
| Process Interface Pressure Rating | 30 bar at flange mounting point |
| Power Supply | 110/220 V AC ±20%, 50/60 Hz, 30 W |
| Housing Material | Nickel-plated stainless steel, aluminum heat sink, NBR sealing |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | NIRFlex N-500 |
| Instrument Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 10000–4000 cm⁻¹ (1000–2500 nm) |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | NIRCal |
| Interferometer Type | TeO₂ Wedge Polarization Interferometer |
| Spectral Resolution | 8 cm⁻¹ |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (at 16 scans) |
| Detector | Temperature-Controlled InGaAs |
| A/D Converter | 24-bit |
| Light Source Lifetime | 12,000 h (dual tungsten halogen lamps) |
| Dimensions | 450 × 550 × 250 mm |
| Weight | 25 kg |
| Operating Environment | 5–35 °C, RH < 80% at ≤31 °C (derating to 67% at 35 °C), altitude ≤2500 m |
| Power Supply | 100–230 V ±10%, 50/60 Hz, <350 W |
| Communication Interface | Ethernet (TCP/IP), 100 Mbit/s |
| IP Rating | IP20 |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Benchtop FT-NIR Spectrometer |
| Model | NIRMaster |
| Spectral Range | 10000–4000 cm⁻¹ |
| Resolution | 8 cm⁻¹ |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Interferometer Type | Polarization Interferometer |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (peak-to-peak, baseline-corrected, 5600–6000 cm⁻¹) |
| Detector | Thermoelectrically Cooled Extended-Range InGaAs |
| Light Source | Dual Halogen Lamp Module (MTBF: 12,000 h) |
| Laser | HeNe, 632.992 nm |
| Operating Temperature | 5–35 °C |
| Relative Humidity | <80% at ≤31 °C (linearly decreasing to 67% at 35 °C) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 150 W |
| Enclosure Material | Food-Grade PMMA or Stainless Steel |
| IP Rating | IP54 (optional IP65) |
| Dimensions (W×H×D) | 360 × 420 × 540 mm |
| Weight | ~43 kg (NIRMaster), ~49 kg (NIRMaster Pro) |
| Chemometrics Software | NIRCal |
| Sample Handling | Easy-Spin magnetic rotation stage for heterogeneous samples |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiMate |
| Instrument Type | Laboratory |
| Measurement Principle | Grating-based non-scanning spectrometer with diode array detector |
| Wavelength Range | 400–1700 nm |
| Scan Speed | 10 ms |
| Data Sampling Interval | 10 nm (visible), 7 nm (NIR) |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Autocal |
| IP Rating | IP69 |
| Weight | 23 kg |
| Dimensions (W × D × H) | 260 × 435 × 500 mm |
| Power Consumption | 60 W |
| Operating Frequency | 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % (at ≤31 °C) |
| Storage Temperature | ≤45 °C |
| Altitude Limit | ≤2000 m |
| Measurement Time | Configurable, default 15 s |
| Optical Configuration Options | Standard NIR only |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiScout |
| Instrument Type | Portable |
| Operating Principle | MEMS-based Micro-Electro-Mechanical Systems NIR Spectroscopy |
| Wavelength Range | 1350–2550 nm |
| Scan Speed | 2 seconds per scan |
| Measurement Mode | Reflectance |
| Chemometrics Software | EigenVector |
| Weight | 1 kg |
| Ingress Protection Rating | IP65 |
| Battery | Dual user-replaceable 18650 rechargeable cells |
| Battery Life | ~800 scans (2 s/scan) |
| Wireless Connectivity | Bluetooth v4.2 BLE |
| Optical Spot Diameter | ~10 mm |
| Charging Port | USB-C |
| Typical Signal-to-Noise Ratio | 2000:1 |
| Spectral Resolution | 16 nm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-815 / Pure C-810 |
| Application Level | Laboratory Grade |
| Instrument Category | Low-to-Medium Pressure Preparative LC |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Operating Pressure | 50 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-835 / Pure C-830 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–100 mL/min |
| Flow Accuracy | ±3% RSD |
| Flow Precision | ±0.5% RSD |
| Maximum Pressure | 300 bar |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | 0.4 nm |
| Baseline Noise | 5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | Pure C-850 |
| Application Level | Laboratory Grade |
| Instrument Category | High-Pressure Preparative LC System |
| Flow Rate Range | 1–250 mL/min |
| Flow Accuracy | RSD < 3% |
| Flow Precision | RSD < 0.5% |
| Maximum Pressure | 300 bar |
| Wavelength Range | ±2 nm (200–800 nm) |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Pure Essential System |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ±1% at 5–250 mL/min |
| Maximum Pressure | 50 bar |
| UV Wavelength Options | Fixed wavelengths at 254, 275, 325, and 365 nm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | R-220 Pro Extraction |
| Capacity | 20 L |
| Ultimate Vacuum | ≤ 20 mbar |
| Rotational Speed | 5–150 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±2 °C |
| Cooling Surface Area | Configuration-dependent (standard glassware set) |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported |
| Model | R-220 Pro |
| Capacity | 20 L |
| Ultimate Vacuum | 1.5 mbar |
| Rotation Speed | 5–150 rpm |
| Heating Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±2 °C |
| Cooling Surface Area | Configurable per glass assembly |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | R-250 Pro |
| Capacity | 50 L |
| Ultimate Vacuum | 1.5 mbar |
| Rotation Speed | 5–120 rpm |
| Bath Temperature Range | 20–180 °C |
| Temperature Control Accuracy | ±1 °C |
| Cooling Surface Area | 5000 cm² |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | R-300 |
| Evaporation Flask Capacity | 5 L |
| Ultimate Vacuum | 2 mbar |
| Rotation Speed Range | 20–280 rpm |
| Heating Bath Temperature Range | 20–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Surface Area | 1700 cm² |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | R-80 |
| Capacity | 1 L |
| Ultimate Vacuum | 10 mbar |
| Rotation Speed | 0–330 rpm |
| Temperature Range | 20–95 °C |
| Cooling Surface Area | 1300 cm² |
| Width | 345 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | R-210 / R-215 |
| Rotation Speed | 20–280 rpm |
| Bath Temperature Range | +20°C to +180°C (B-491) or +20°C to +95°C (B-495) |
| Evaporation Flask Capacity | 50–4000 mL |
| Max. Flask Weight | 3 kg |
| Display | Basic (R-210) / Steam Temperature & Rotation Speed (R-215) |
| Vacuum Pump | V-700 (1.8 m³/h, <10 mbar final vacuum) or V-710 |
| Vacuum Controller | V-850 (standard) / V-855 (advanced, with pressure gradient programming & EasyVac) |
| IP Rating | IP21 |
| Power Supply | 100–240 V, 50/60 Hz |
| Dimensions (L×H×D) | 550 × 575 × 415 mm |
| Weight | 16–18 kg (without bath) |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | Sepacore |
| Pressure Range | Up to 50 bar (725 psi) |
| Flow Rate | 2.5–250 mL/min |
| Column ID Range | 15–100 mm |
| Max Sample Load | 100 g (glass columns) |
| Detector Wavelength | 190–745 nm |
| Gradient Capability | Binary to Quaternary, 0–100% B, linearity ±2% |
| Software | SepacoreControl (PC-based, optional 21 CFR Part 11 compliance) |
| Pump Type | Tri-piston, pulse-free, solvent-compatible with acids/bases/organics |
| Column Options | Glass (coated), polypropylene flash columns, cartridge-based packing systems |
| Fraction Collection Modes | Time-, volume-, or UV peak-triggered |
| Safety Features | Grounded metal fraction collector arm, transparent pressure-rated glass columns, integrated pressure sensors and level monitoring |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Preparative SFC System |
| Model | SFC-250 |
| Flow Rate Range | 0–250 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar (CO₂ and modifier pumps) |
| Detector Options | Diode Array Detector (DAD), Mass Spectrometer (MS), Evaporative Light Scattering Detector (ELSD) |
| Modifier Channels | 4 |
| Injection Loop Volume | 2.5 mL |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 15–30 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| Gradient Capability | Isocratic, binary linear, or step gradients |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Preparative SFC System |
| Model | SFC-50 |
| Flow Rate Range | 1–50 mL/min (including up to 40% modifier) |
| Maximum Pressure | 400 bar |
| Detector Options | DAD, ELSD, Mass Spectrometer (MS) |
| Column Capacity | Up to 10 columns (2 mounted simultaneously) |
| Column Dimensions | ID 4–16 mm, max. length 250 mm |
| Column Oven Temperature Range | Ambient to 70 °C |
| UV Wavelength Range (DAD) | 190–720 nm |
| Power Supply | 230 V ±10%, 50/60 Hz |
| Operating Environment | 15–25 °C, 45–75% RH |
| Dimensions (W×D×H) | 560 × 600 × 880 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SFC-660 |
| Instrument Type | Preparative |
| Flow Rate Range | 0–660 mL/min (including up to 40% modifier) |
| Maximum Operating Pressure | 400 bar |
| Detector Options | Diode Array Detector (DAD), Electrospray Light Scattering Detector (ELSD), Mass Spectrometer (MS) |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | SpeedExtractor E-916 |
| Temperature Range | 50–200 °C (±3 °C) |
| Pressure Range | 50–150 bar (±5 bar) |
| Extraction Cell Volumes | 10, 20, 40 mL |
| Solvent Consumption per Sample | 5–200 mL |
| Solvent Delivery Flow Rate | 0.01–50 mL/min (±2 %) |
| Integrated Solvent Mixer | 2-port or 4-port |
| Power Consumption | 1750 W |
| Electrical Supply | 100–240 VAC ±10 %, 50–60 Hz |
| Nitrogen Supply Requirement | 5–10 bar, purity 4.5–5.0 |
| Wetted Materials | FEP, FFPM, PEEK, PTFE, stainless steel, ceramic, borosilicate glass |
| Interface | USB 2.0 |
| Dimensions (W×H×D) | 670 × 725 × 500 mm |
| Weight | 90 kg |
| Ingress Protection | IP21 |
| Certifications | CE, CSA |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SyncorePlus R-12 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 20–100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume Capacity per Vial | 0.5–500 mL |
| Vacuum Range | 1 mbar to atmospheric pressure |
| Rotational Speed | 60–400 rpm |
| Final Vacuum (Absolute) | 8 mbar |
| Pump Flow Rate | 1.8 m³/h |
| Cooling Unit Temp. Range | −10 to +25 °C |
| Cooling Capacity @ 15 °C | 800 W |
| Power Supply | 220–240 V, 50/60 Hz, Max 1400 W |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Laboratory Diaphragm Vacuum Pump |
| Model | V-300 |
| Dimensions (W × D × H) | 200 × 321 × 291 mm |
| Weight | 7.6 kg |
| Motor Power | 180 W |
| Ultimate Vacuum | 5 mbar |
| Pumping Speed | 1.8 m³/h |
| Construction | PTFE Diaphragm, PEEK/Glass Transparent View Window, Oil-Free Design |
| ECO Mode | Yes (80% → 50% power reduction after 1 h / 2 h idle) |
| Safety | Interlocked Housing Switch, Resettable Thermal Protection, Built-in Timer |
| Optional Modules | I-300/I-300 Pro Interface, Level Sensor, Secondary Condenser |